Seq # *Modification Id* Act
----------------------------+
00001 M01S00001.compflf +++| CTEXT COMPFLF - FLUSH LOCAL FILES.
00002 M01S00002.compflf +++| SPACE 4
00003 M01S00003.compflf +++| IF -DEF,QUAL$,1
00004 M01S00004.compflf +++| QUAL COMPFLF
Line S00005 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 281l803 |
Seq # *Modification Id* Act
----------------------------+
00005 M02S00005.281l803 ---|* COMMENT COPYRIGHT CONTROL DATA CORP. 1979.
00006 M01S00001.281l803 +++|* COMMENT COPYRIGHT CONTROL DATA SYSTEMS INC. 1992.
00007 M01S00006.compflf +++| FLF SPACE 4,10
00008 M01S00007.compflf +++|*** FLF - FLUSH LOCAL FILES.
00009 M01S00008.compflf +++|* S. L. BETH. 79/10/22.
00010 M01S00009.compflf +++|* P. T. BARNETT. 82/10/07.
00011 M01S00010.compflf +++| FLF SPACE 4,10
00012 M01S00011.compflf +++|*** *FLF* WILL INSURE THAT ALL FILES LOCAL TO A JOB THAT ARE
00013 M01S00012.compflf +++|* RESIDING ON A BUFFERED DEVICE ARE FLUSHED TO THE DISK.
00014 M01S00001.271l716 +++|*
Line S00002 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00015 M02S00002.273l780 ---|* IF SYMBOL *PCP$* IS DEFINED, *FLF* MAY BE CALLED TO PROCESS
Line S00003 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00016 M02S00003.273l780 ---|* THE FILES OF A PCP JOB. IN THIS CASE, *FLF* USES MACRO
Line S00004 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00017 M02S00004.273l780 ---|* *LCPA* TO COMPUTE THE CPA/PCPA ADDRESS. THIS REQUIRES THAT
Line S00005 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00018 M02S00005.273l780 ---|* COMMON DECK *COMSPCP* BE CALLED PRIOR TO THIS POINT, WITH
Line S00006 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00019 M02S00006.273l780 ---|* SYMBOLS *LCP$* AND *PLC$* DEFINED.
00020 M01S00001.273l780 +++|* ENTRY (A) = NFL SIZE OF CONTROL POINT OR PSEUDO-CONTROL
00021 M01S00002.273l780 +++|* POINT TO PROCESS.
00022 M01S00013.compflf +++|*
Line S00014 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00023 M02S00014.273l780 ---|* USES T3 - T7, CM - CM+5, CN.- CN+4.
Line S00015 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00024 M02S00015.273l780 ---|*
Line S00007 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00025 M02S00007.273l780 ---|* MACROS LCPA.
00026 M01S00003.273l780 +++|* USES T3 - T7, CM - CM+5, CN - CN+4.
00027 M01S00008.271l716 +++|*
00028 M01S00016.compflf +++|* MACROS MONITOR, NFA, SFA.
00029 M01S00017.compflf +++|
00030 M01S00018.compflf +++|
00031 M01S00019.compflf +++| FLF SUBR ENTRY/EXIT
00032 M01S00004.273l780 +++| ADN 1 SET LIMIT FOR FILE SEARCH
00033 M01S00005.273l780 +++| STD T3
00034 M01S00020.compflf +++| LDK BIOL CHECK PRESENCE OF BUFFERED I/O
00035 M01S00021.compflf +++| CRD CM
00036 M01S00022.compflf +++| LDD CM+1
00037 M01S00023.compflf +++| SHN 14
00038 M01S00024.compflf +++| ADD CM+2
00039 M01S00025.compflf +++| ZJN FLFX IF BUFFERED I/O NOT IN USE
00040 M01S00026.compflf +++| ADN /COMSHIO/CBTP READ CONTROL BUFFER ADDRESS
00041 M01S00027.compflf +++| CRD CM
00042 M01S00028.compflf +++| LDD CM+4
00043 M01S00029.compflf +++| RAM FLFA+1
00044 M01S00030.compflf +++| SHN -14
00045 M01S00031.compflf +++| ADD CM+3
00046 M01S00032.compflf +++| RAM FLFA
Line S00033 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 271l716 |
Seq # *Modification Id* Act
----------------------------+
00047 M02S00033.271l716 ---| LDD CP INITIALIZE SEARCH
Line S00034 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 271l716 |
Seq # *Modification Id* Act
----------------------------+
00048 M02S00034.271l716 ---| ADN FLSW
Line S00009 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00049 M02S00009.273l780 ---| PCP$ IF DEF,PCP$
Line S00010 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00050 M02S00010.273l780 ---| IF -DEF,PLC$,1
Line S00011 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00051 M02S00011.273l780 ---| ERR ACCUMULATOR MUST CONTAIN CP/PCP NUMBER
Line S00012 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00052 M02S00012.273l780 ---| LCPA FLSW COMPUTE CPA/PCPA ADDRESS
Line S00013 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00053 M02S00013.273l780 ---| PCP$ ELSE
Line S00014 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00054 M02S00014.273l780 ---| LDD CP
Line S00015 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00055 M02S00015.273l780 ---| ADN FLSW
Line S00016 Modification History |
M01 (Added by) | 271l716 |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00056 M02S00016.273l780 ---| PCP$ ENDIF
Line S00035 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00057 M02S00035.273l780 ---| CRD CM
Line S00036 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00058 M02S00036.273l780 ---| LDD CM SET NFL OFFSET FOR THE LOCAL FNT
Line S00037 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00059 M02S00037.273l780 ---| SHN 6
Line S00038 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00060 M02S00038.273l780 ---| ADN 1
Line S00039 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 273l780 |
Seq # *Modification Id* Act
----------------------------+
00061 M02S00039.273l780 ---| STD T3
00062 M01S00040.compflf +++| LDC FNTN SET FIRST ENTRY
00063 M01S00041.compflf +++| STD T4
00064 M01S00042.compflf +++| FLF1 NFA T4,R READ NFL ENTRY
00065 M01S00043.compflf +++| ADN FSTL
00066 M01S00044.compflf +++| CRD T5
00067 M01S00045.compflf +++| LDD T5
00068 M01S00046.compflf +++| LPC 777
00069 M01S00047.compflf +++| ZJN FLF2 IF EMPTY ENTRY
00070 M01S00048.compflf +++| SFA EST CHECK FOR BUFFERED DEVICE
00071 M01S00049.compflf +++| ADK EQDE
00072 M01S00050.compflf +++| CRD CM
00073 M01S00001.pflf1 +++| LDD CM
00074 M01S00002.pflf1 +++| SHN 21-13
00075 M01S00003.pflf1 +++| PJN FLF2 IF NOT MASS STORAGE
00076 M01S00051.compflf +++| LDD CM+4 MST ADDRESS / 10B
00077 M01S00052.compflf +++| SHN 3
00078 M01S00053.compflf +++| ADK DILL
00079 M01S00054.compflf +++| CRD CM
00080 M01S00055.compflf +++| LDD CM+3
00081 M01S00056.compflf +++| SHN 21-12
00082 M01S00057.compflf +++| FLF2 PJP FLF5 IF NOT BUFFERED DEVICE
00083 M01S00058.compflf +++| NFA T4,R READ FNT
00084 M01S00059.compflf +++| ADK FUTL
00085 M01S00060.compflf +++| CRD CN
00086 M01S00061.compflf +++| LDD CN+4
00087 M01S00062.compflf +++| SHN /COMSHIO/CBTLS
Line S00063 Modification History |
M01 (Added by) | compflf |
M02 (Updated by) | 271l716 |
Seq # *Modification Id* Act
----------------------------+
00088 M02S00063.271l716 ---| ZJN FLF5 IF NO CONTROL BUFFER INDEX
00089 M01S00017.271l716 +++| ZJN FLF2 IF NO CONTROL BUFFER INDEX
00090 M01S00064.compflf +++| FLFA ADC /COMSHIO/LSLK READ CONTROL BUFFER
00091 M01S00065.compflf +++| CRD T7
00092 M01S00066.compflf +++| SBN -/COMSHIO/IOLK+/COMSHIO/LSLK
00093 M01S00067.compflf +++| CRD CM
00094 M01S00068.compflf +++| SBN -/COMSHIO/FSTC+/COMSHIO/IOLK
00095 M01S00069.compflf +++| CRD CM+1
00096 M01S00070.compflf +++| LDD T7
00097 M01S00071.compflf +++| NJN FLF4 IF BUFFER BEING ACCESSED
00098 M01S00072.compflf +++| LDD CM+1 COMPARE FST INFORMATION
00099 M01S00073.compflf +++| LMD T5
00100 M01S00074.compflf +++| LPC 777
00101 M01S00075.compflf +++| NJN FLF4 IF BUFFER NOT FOR SAME EQUIPMENT
00102 M01S00076.compflf +++| LDD CM+2
00103 M01S00077.compflf +++| ZJN FLF3 IF NO FIRST TRACK (*PIOM* READ BUFFER)
00104 M01S00078.compflf +++| LMD T6
00105 M01S00079.compflf +++| NJN FLF4 IF NOT SAME TRACK
00106 M01S00080.compflf +++| FLF3 LDD CM
00107 M01S00081.compflf +++| LPC 5000
00108 M01S00082.compflf +++| LMD TH
00109 M01S00083.compflf +++| ZJN FLF6 IF WRITE DATA
00110 M01S00084.compflf +++| FLF4 LDN 0 CLEAR BUFFER INDEX
00111 M01S00085.compflf +++| STD CN+4
00112 M01S00086.compflf +++| NFA T4,R
00113 M01S00087.compflf +++| ADK FUTL
00114 M01S00088.compflf +++| CWD CN
00115 M01S00089.compflf +++| FLF5 LDN LENF ADVANCE TO NEXT ENTRY
00116 M01S00090.compflf +++| RAD T4
00117 M01S00091.compflf +++| SBD T3
00118 M01S00092.compflf +++| MJP FLF1 IF NOT END OF LOCAL FNT
00119 M01S00093.compflf +++| LJM FLFX RETURN
00120 M01S00094.compflf +++|
00121 M01S00095.compflf +++| FLF6 LDD T4 SET FNT ORDINAL
00122 M01S00096.compflf +++| STD CM+4
00123 M01S00097.compflf +++| LDC FLBS*100 REQUEST BUFFER FLUSH
00124 M01S00098.compflf +++| STD CM+1
00125 M01S00099.compflf +++| MONITOR PIOM
00126 M01S00100.compflf +++| UJN FLF5 CONTINUE SCAN
00127 M01S00101.compflf +++|
00128 M01S00102.compflf +++|
00129 M01S00103.compflf +++| QUAL$ IF -DEF,QUAL$
00130 M01S00104.compflf +++| QUAL *
00131 M01S00105.compflf +++| FLF EQU /COMPFLF/FLF
00132 M01S00106.compflf +++| QUAL$ ENDIF
00133 M01S00107.compflf +++| ENDX