Seq # *Modification Id* Act
----------------------------+
00001 M00S00001.1lc +++| IDENT 1LC,LCW
00002 M00S00002.1lc +++| PERIPH
00003 M00S00003.1lc +++| BASE MIXED
00004 M00S00004.1lc +++| SST
00005 M00S00005.1lc +++| TITLE 1LC - LOAD BUFFER CONTROLWARE.
00006 M00S00006.1lc +++|*COMMENT 1LC - LOAD BUFFER CONTROLWARE ROUTINE.
Line S00007 Modification History
M01
(Removed by) 281l803
Seq # *Modification Id* Act
----------------------------+
00007 M01S00007.281l803 ---| COMMENT COPYRIGHT CONTROL DATA CORPORATION. 1983.
Line S00001 Modification History
M01
(Added by) 281l803
Seq # *Modification Id* Act
----------------------------+
00008 M01S00001.281l803 +++| COMMENT COPYRIGHT CONTROL DATA SYSTEMS INC. 1992.
00009 M00S00008.1lc +++| 1LC SPACE 4,10
00010 M00S00009.1lc +++|***** 1LC - LOAD BUFFER CONTROLWARE.
00011 M00S00010.1lc +++|*
00012 M00S00011.1lc +++|* W. J. SMITH. 79/07/21.
00013 M00S00012.1lc +++|* J. L. LARSON. 83/06/14.
00014 M00S00013.1lc +++|*
00015 M00S00014.1lc +++|* DOWNLOAD DISK CONTROLWARE ON SPECIFIED CHANNEL.
00016 M00S00015.1lc +++| 1LC SPACE 4,10
00017 M00S00016.1lc +++|*** *1LC*, IN CONJUNCTION WITH THE CPU PROGRAM *LOADBC, WILL
00018 M00S00017.1lc +++|* DOWNLOAD CONTROLWARE TO THE REQUESTED CHANNEL AND
00019 M00S00018.1lc +++|* CONTROLLER.
00020 M00S00019.1lc +++|*
00021 M00S00020.1lc +++|* CALL -
00022 M00S00021.1lc +++|*
00023 M00S00022.1lc +++|*T,IR 18/ *1LC*,6/ 0,18/ DADDR,18/ LADDR
Figure
IR
0 17 18 29 LADDR DADDR 30 35 36 41 42 59 DADDR 0 *1LC*
00024 M00S00023.1lc +++|* DADDR FET ADDRESS FOR CONTROLWARE DUMP.
00025 M00S00024.1lc +++|* = 0 IF CONTROLWARE NOT TO BE DUMPED BEFORE RELOAD.
00026 M00S00025.1lc +++|* LADDR FET ADDRESS OF CONTROLWARE TO LOAD.
00027 M00S00026.1lc +++|*
00028 M00S00027.1lc +++|* *LOADBC* USES RECALL MACRO WHEN CALLING *1LC*.
00029 M00S00028.1lc +++| 1LC SPACE 4,20
00030 M00S00029.1lc +++|*** *1LC* IS A PP PROGRAM CALLED BY THE CPU PROGRAM *LOADBC*
00031 M00S00030.1lc +++|* TO DOWNLOAD DISK CONTROLWARE ON A SPECIFIED CHANNEL OR TO
00032 M00S00031.1lc +++|* DOWNLOAD CONTROL MODULE CONTROLWARE TO A SPECIFIED CONTROL
00033 M00S00032.1lc +++|* MODULE. THE CONTROLWORD AT FET+8 IN *LOADBC* FL CONTAINS
00034 M00S00033.1lc +++|* EITHER THE CHANNEL NUMBER OR THE CONTROL MODULE EST ORDINAL
00035 M00S00034.1lc +++|* (IN WHICH CASE BIT 2**11 IS SET).
00036 M00S00035.1lc +++|* THE CONTROLWARE IS CHECKED FOR ITS VALIDITY, READ FROM FIELD
00037 M00S00036.1lc +++|* LENGTH OF *LOADBC* IN SEGMENTS AND DOWNLOADED. CONTROLLER
00038 M00S00037.1lc +++|* IS STATUSED FOR ITS FUNCTIONALITY (GENERAL STATUS OF ZERO
00039 M00S00038.1lc +++|* INDICATES CORRECT CHECKSUM) AND A RESPONSE CODE OF ZERO IS
00040 M00S00039.1lc +++|* RETURNED IN FET+0 ON A SUCCESSFUL LOAD. A NON-ZERO RESPONSE
00041 M00S00040.1lc +++|* CODE IS RETURNED FOR UNSUCCESSFUL LOADS.
00042 M00S00041.1lc +++|* IF A NONZERO DUMP CONTROLWARE FET ADDRESS IS ALSO SPECIFIED,
00043 M00S00042.1lc +++|* THE CONTENTS OF THE 7255 ADAPTOR, THE 7155 CONTROLLER (FMD OR
00044 M00S00043.1lc +++|* DEMA) OR THE 7165 CONTROLLER WILL BE DUMPED TO THE BUFFER
00045 M00S00044.1lc +++|* BEFORE THE RELOAD IS ATTEMPTED. A ZERO RESPONSE CODE IS
00046 M00S00045.1lc +++|* RETURNED TO THE DUMP FET+0 ON A SUCCESSFUL DUMP.
00047 M00S00046.1lc +++|* A NON-ZERO RESPONSE CODE IS RETURNED FOR BUFFER ERROR
00048 M00S00047.1lc +++|* CONDITIONS, UNSUCCESSFUL DUMPS, AND FOR DUMP REQUESTS OF
00049 M00S00048.1lc +++|* CONTROLLERS/ADAPTORS NOT LISTED ABOVE. THE NUMBER OF THE
00050 M00S00049.1lc +++|* CHANNEL THAT WAS USED TO LOAD CONTROLWARE IS RETURNED IN
00051 M00S00050.1lc +++|* FET+8, BYTE 0.
00052 M00S00051.1lc +++| 1LC SPACE 4,10
00053 M00S00052.1lc +++|*** DAYFILE MESSAGES.
00054 M00S00053.1lc +++|*
00055 M00S00054.1lc +++|* * FET ADDRESS OUT OF RANGE.* - THE CONTROLWARE DUMP OR
00056 M00S00055.1lc +++|* LOAD FET ADDRESS IS .LE. 1 OR EXTENDS PAST FL.
00057 M00S00056.1lc +++| SPACE 4,10
00058 M00S00057.1lc +++|* MACROS.
00059 M00S00058.1lc +++|
00060 M00S00059.1lc +++|
00061 M00S00060.1lc +++|*CALL COMPMAC
00062 M00S00061.1lc +++|*CALL COMSCPS
00063 M00S00062.1lc +++|*CALL COMPCHM
00064 M00S00063.1lc +++|*CALL COMSDSL
00065 M00S00064.1lc +++|*CALL COMSPIM
00066 M00S00065.1lc +++|*CALL COMSSSD
00067 M00S00066.1lc +++| SPACE 4,10
00068 M00S00067.1lc +++|* ASSEMBLY CONSTANTS.
00069 M00S00068.1lc +++|
00070 M00S00069.1lc +++|
00071 M00S00070.1lc +++| BUFL EQU 1000 LENGTH OF CONTROLWARE BLOCK
00072 M00S00071.1lc +++| FCDC EQU 701 DUMP 7165 CONTROLLER MEMORY
00073 M00S00072.1lc +++| FCLA EQU 500 LOAD ADDRESS AND LENGTH (7165 DUMP)
00074 M00S00073.1lc +++| FCAL EQU 414 AUTOLOAD FUNCTION CODE
00075 M00S00074.1lc +++| FCLC EQU 71 CONTROL MODULE LOAD FROM PP FUNCTION
00076 M00S00075.1lc +++| FCAR EQU 67 AUTOLOAD WITH NO DROP OF DRIVE RESERVES
00077 M00S00076.1lc +++| FCDM EQU 63 DUMP CONTROLLER MEMORY FUNCTION CODE
00078 M00S00077.1lc +++| FCMP EQU 62 MANIPULATE PROCESSOR FUNCTION CODE
00079 M00S00078.1lc +++| FCST EQU 12 GENERAL STATUS FUNCTION CODE
00080 M00S00079.1lc +++| FCOC EQU 10 OPERATION COMPLETE CODE
00081 M00S00080.1lc +++| FCCN EQU 0 CONNECT FUNCTION CODE
00082 M00S00081.1lc +++| SPACE 4,10
00083 M00S00082.1lc +++|* 7155 CONTROLLER DUMP ASSEMBLY CONSTANTS.
00084 M00S00083.1lc +++|
00085 M00S00084.1lc +++|
00086 M00S00085.1lc +++| CTSZ EQU 8192D 7155 CONTROLLER MEMORY SIZE (16 BIT WORDS)
00087 M00S00086.1lc +++| CWDB EQU 32D CONTROLLER WORDS PER MEMORY DUMP BLOCK
00088 M00S00087.1lc +++| PBDB EQU CWDB*2 PP BYTES PER DUMP BLOCK
00089 M00S00088.1lc +++| NCBD EQU CTSZ/CWDB NUMBER OF CONTROLLER BLOCKS TO DUMP
00090 M00S00089.1lc +++| SPACE 4,10
00091 M00S00090.1lc +++|* RESPONSE CODES RETURNED TO LOAD FET+0.
00092 M00S00091.1lc +++|
00093 M00S00092.1lc +++|
00094 M00S00093.1lc +++| RC0 EQU 0 CONTROLWARE LOAD COMPLETE
00095 M00S00094.1lc +++| RC1 EQU 1 * USER NOT SYSTEM ORIGIN.*
00096 M00S00095.1lc +++| RC2 EQU 2 * SPECIFIED CHANNEL IS IN USE.*
00097 M00S00096.1lc +++| RC3 EQU 3 RESERVED BY CPU ROUTINE *LOADBC*
00098 M00S00097.1lc +++| RC4 EQU 4 RESERVED BY CPU ROUTINE *LOADBC*
00099 M00S00098.1lc +++| RC5 EQU 5 RESERVED BY CPU ROUTINE *LOADBC*
00100 M00S00099.1lc +++| RC6 EQU 6 RESERVED BY CPU ROUTINE *LOADBC*
00101 M00S00100.1lc +++| RC7 EQU 7 RESERVED BY CPU ROUTINE *LOADBC*
00102 M00S00101.1lc +++| RC10 EQU 10 RESERVED BY CPU ROUTINE *LOADBC*
00103 M00S00102.1lc +++| RC11 EQU 11 * SYSTEM NOT IN ENGR MODE.*
00104 M00S00103.1lc +++| RC12 EQU 12 * BUFFER ARGUMENT ERROR.*
00105 M00S00104.1lc +++| RC13 EQU 13 CDC RESERVED
00106 M00S00105.1lc +++| RC14 EQU 14 * CONTROLWARE LOAD ALREADY IN PROGRESS.*
00107 M00S00106.1lc +++| RC15 EQU 15 * NO 77 TABLE IN CONTROLWARE RECORD.*
00108 M00S00107.1lc +++| RC16 EQU 16 * NO 52 TABLE IN CONTROLWARE RECORD.*
00109 M00S00108.1lc +++| RC17 EQU 17 * LENGTH IN 52 TABLE .NE. FET.*
00110 M00S00109.1lc +++| RC20 EQU 20 RESERVED BY CPU ROUTINE *LOADBC*
00111 M00S00110.1lc +++| RC21 EQU 21 * NOT CONTROL MODULE EST ORDINAL.*
00112 M00S00111.1lc +++| RC22 EQU 22 CDC RESERVED
00113 M00S00112.1lc +++| RC23 EQU 23 CDC RESERVED
00114 M00S00113.1lc +++| RC24 EQU 24 CDC RESERVED
00115 M00S00114.1lc +++| RC25 EQU 25 CDC RESERVED
00116 M00S00115.1lc +++| RC26 EQU 26 CDC RESERVED
00117 M00S00116.1lc +++| RC27 EQU 27 CDC RESERVED
00118 M00S00117.1lc +++| RC30 EQU 30 * CONTROLLER DID NOT TAKE ALL CONTROLWARE*
00119 M00S00118.1lc +++| RC31 EQU 31 * GENERAL STATUS = NNNN.*
00120 M00S00119.1lc +++| RC32 EQU 32 * FUNCTION TIMED OUT=NNNN.*
00121 M00S00120.1lc +++| RC33 EQU 33 * NO GENERAL STATUS RECEIVED.*
00122 M00S00121.1lc +++| RC34 EQU 34 * CHXX, CONTROLLER RESERVED.*
00123 M00S00122.1lc +++| SPACE 4,10
00124 M00S00123.1lc +++|* DUMP CONTROLWARE RESPONSE CODES RETURNED TO DUMP FET+0.
00125 M00S00124.1lc +++|
00126 M00S00125.1lc +++|
00127 M00S00126.1lc +++| DR0 EQU 0 * CONTROLLER DUMP COMPLETE.*
00128 M00S00127.1lc +++| DR1 EQU 1 * DUMP BUFFER ARGUMENT ERROR.*
00129 M00S00128.1lc +++| DR2 EQU 2 * INSUFFICIENT DUMP BUFFER SPACE.*
00130 M00S00129.1lc +++| DR3 EQU 3 * NOT CORRECT CONTROLLER TYPE FOR DUMP.*
00131 M00S00130.1lc +++| DR4 EQU 4 * CONTROLLER DUMP UNSUCCESSFUL.*
00132 M00S00131.1lc +++| SPACE 4,10
00133 M00S00132.1lc +++|* DIRECT CORE ASSIGNMENTS.
00134 M00S00133.1lc +++|
00135 M00S00134.1lc +++|
00136 M00S00135.1lc +++| BC EQU 20 BUFFER CONTROLLER CHANNEL NUMBER
00137 M00S00136.1lc +++| ST EQU 21 CONTROLLER GENERAL STATUS
00138 M00S00137.1lc +++| WC EQU 22 CONTROLWARE CM WORD COUNT
00139 M00S00138.1lc +++| FN EQU 23 LAST FUNCTION ISSUED TO CONTROLLER
Line S00001 Modification History
M01
(Added by) ns2604
Seq # *Modification Id* Act
----------------------------+
00140 M01S00001.ns2604 +++| RC EQU 26 RESPONSE CODE
00141 M01S00002.ns2604 +++| DR EQU 27 DUMP FET RESPONSE CODE
00142 M00S00139.1lc +++| DP EQU 30 - 34 DATA POINTERS (5 LOCATIONS)
00143 M00S00140.1lc +++| CT EQU 35 CONTROLWARE TYPE
00144 M00S00141.1lc +++| CE EQU 36 - 37 CHANNEL CONTROLWARE ENTRY
00145 M00S00142.1lc +++| DB EQU 40 - 44 DUMP FET BUFFER POINTERS
Line S00143 Modification History
M01
(Removed by) ns2604
Seq # *Modification Id* Act
----------------------------+
00146 M01S00143.ns2604 ---| RC EQU 45 RESPONSE CODE
00147 M01S00144.ns2604 ---| DR EQU 46 DUMP FET RESPONSE CODE
00148 M00S00145.1lc +++| CS EQU 47 CHANNEL SPECIFIED ON CALL STATUS
00149 M00S00146.1lc +++| CN EQU 60 - 64 CM WORD BUFFER
00150 M00S00147.1lc +++| CO EQU 65 CONTROL MODULE EST ORDINAL
00151 M00S00148.1lc +++| EQ EQU 66 CONTROL MODULE EQUIPMENT NUMBER
00152 M00S00149.1lc +++| CF EQU 67 CHANNEL RESERVED BY *1LC* FLAG
00153 M00S00150.1lc +++| TITLE MAIN PROGRAM.
00154 M00S00151.1lc +++| ORG PPFW
00155 M00S00152.1lc +++| LCW SPACE 4,10
00156 M00S00153.1lc +++|** LCW - LOAD BUFFER CONTROLWARE MAIN PROGRAM.
00157 M00S00154.1lc +++|
00158 M00S00155.1lc +++|
00159 M00S00156.1lc +++| LCW BSS 0 ENTRY
00160 M00S00157.1lc +++| RJM PRS PRESET LOAD CONTROLWARE
00161 M00S00158.1lc +++| STD RC
Line S00159 Modification History
M01
(Removed by) 1lc7
Seq # *Modification Id* Act
----------------------------+
00162 M01S00159.1lc7 ---| NJP LCW5 IF ERROR RESPONSE
Line S00001 Modification History
M01
(Added by) 1lc7
Seq # *Modification Id* Act
----------------------------+
00163 M01S00001.1lc7 +++| LMK RC14
00164 M01S00002.1lc7 +++| ZJP LCW5 IF RELOAD ALREADY IN PROGRESS
00165 M01S00003.1lc7 +++| LMK RC14
00166 M01S00004.1lc7 +++| NJN LCW2.1 IF OTHER ERROR
00167 M00S00160.1lc +++| LDD CO
00168 M00S00161.1lc +++| NJN LCW0 IF CONTROL MODULE SPECIFIED
Line S00162 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00169 M01S00162.1lc5 ---| RJM RSC RESERVE AND STATUS CHANNEL
00170 M01S00163.1lc5 ---| NJN LCW2 IF ERROR RESPONSE
00171 M00S00164.1lc +++| RJM DCT DUMP CONTROLLER
00172 M00S00165.1lc +++| LCW0 RJM LCT LOAD CONTROLWARE
00173 M00S00166.1lc +++| NJN LCW2 IF ERROR RESPONSE
00174 M00S00167.1lc +++| LDD CS
00175 M00S00168.1lc +++| ZJN LCW1 IF DRIVER CALL
00176 M00S00169.1lc +++| LDN FCOC
00177 M00S00170.1lc +++| RJM FNC
00178 M00S00171.1lc +++| NJN LCW2 IF FUNCTION TIMEOUT
00179 M00S00172.1lc +++| LCW1 LDD ST CHECK STATUS
00180 M00S00173.1lc +++| ERRNZ RC0 CODE DEPENDS ON VALUE
00181 M00S00174.1lc +++| ZJN LCW2 IF NO ERROR
00182 M00S00175.1lc +++| LDN RC31 * GENERAL STATUS = NNNN.*
00183 M00S00176.1lc +++| LCW2 STD RC
Line S00177 Modification History
M01
(Removed by) 1lc7
Seq # *Modification Id* Act
----------------------------+
00184 M01S00177.1lc7 ---| LDD CS
Line S00005 Modification History
M01
(Added by) 1lc7
Seq # *Modification Id* Act
----------------------------+
00185 M01S00005.1lc7 +++| LCW2.1 LDD CS
00186 M00S00178.1lc +++| ZJN LCW3 IF DRIVER CALL
00187 M00S00179.1lc +++| RJM DCH DROP CHANNEL ASSIGNMENT
00188 M00S00180.1lc +++| UJN LCW4 CLEAR CHANNEL ENTRY INTERLOCK
00189 M00S00181.1lc +++|
Line S00182 Modification History
M01
(Removed by) 1lc4
Seq # *Modification Id* Act
----------------------------+
00190 M01S00182.1lc4 ---| LCW3 LDD RC
00191 M01S00183.1lc4 ---| NJN LCW4 IF ERROR
00192 M01S00184.1lc4 ---| AOM CHTI+1*5 CLEAR SYSTEM REQUEST FLAG
Line S00001 Modification History
M01
(Added by) 1lc4
Seq # *Modification Id* Act
----------------------------+
00193 M01S00001.1lc4 +++| LCW3 AOM CHTI+1*5 CLEAR SYSTEM REQUEST FLAG
00194 M00S00185.1lc +++| AOM LCWA INCREMENT CONTROLLER LOADED COUNT
00195 M00S00186.1lc +++| LCW4 LDM CHTI+4
00196 M00S00187.1lc +++| LCWA ADN 0
Line S00188 Modification History
M01
(Removed by) 1lc4
Seq # *Modification Id* Act
----------------------------+
00197 M01S00188.1lc4 ---|* ADN 1 (SYSTEM REQUEST AND CONTROLWARE LOADED)
Line S00002 Modification History
M01
(Added by) 1lc4
Seq # *Modification Id* Act
----------------------------+
00198 M01S00002.1lc4 +++|* ADN 1 (DRIVER CALL)
00199 M00S00189.1lc +++| STM CHTI+1*5+4
00200 M00S00190.1lc +++| RJM ICE CLEAR CHANNEL ENTRY INTERLOCK
00201 M00S00191.1lc +++| LDD CM+1
00202 M00S00192.1lc +++| NJN LCW4 IF VERIFY OF LOAD COUNT FAILED
00203 M00S00193.1lc +++| LCW5 RJM SDR SET DUMP FET RESPONSE
00204 M00S00194.1lc +++| RJM GLA FET LOAD FET ADDRESS
00205 M00S00195.1lc +++| CRD CM READ LOAD FET+0
00206 M00S00196.1lc +++| LDN ZERL
00207 M00S00197.1lc +++| CRD CN
00208 M00S00198.1lc +++| LDD RC GET REPLY CODE
00209 M00S00199.1lc +++| SHN 1
00210 M00S00200.1lc +++| LMN 1 SET COMPLETE BIT
00211 M00S00201.1lc +++| STD CM+4
00212 M00S00202.1lc +++| LMN RC32*2+1
00213 M00S00203.1lc +++| NJN LCW6 IF NOT FUNCTION TIME OUT ERROR
00214 M00S00204.1lc +++| LDD FN
00215 M00S00205.1lc +++| UJN LCW7 RETURN LAST FUNCTION TO FET
00216 M00S00206.1lc +++|
00217 M00S00207.1lc +++| LCW6 LDD ST RETURN GENERAL STATUS TO FET
00218 M00S00208.1lc +++| LCW7 STD CN+4
00219 M00S00209.1lc +++| LDD BC RETURN CHANNEL NUMBER
00220 M00S00210.1lc +++| STD CN
00221 M00S00211.1lc +++| RJM GLA GET LOAD FET ADDRESS
00222 M00S00212.1lc +++| ADN 8D
00223 M00S00213.1lc +++| CWD CN WRITE FET+8 RESPONSE DATA
00224 M00S00214.1lc +++| SBN 8D
00225 M00S00215.1lc +++| CWD CM WRITE FET+0 COMPLETION STATUS
00226 M00S00216.1lc +++| MONITOR DPPM DROP PP
00227 M00S00217.1lc +++| LJM PPR EXIT TO PP RESIDENT
00228 M00S00218.1lc +++| TITLE SUBROUTINES.
00229 M00S00219.1lc +++| CCS SPACE 4,10
00230 M00S00220.1lc +++|** CCS - CHECK CONTROLLER STATUS.
00231 M00S00221.1lc +++|*
00232 M00S00222.1lc +++|* EXIT (A) = 0 IF STATUS RECEIVED.
00233 M00S00223.1lc +++|* (A) = *RC22* IF STATUS FUNCTION TIMEOUT.
00234 M00S00224.1lc +++|* (A) = *RC23* IF STATUS NOT RECEIVED.
00235 M00S00225.1lc +++|* (ST) = STATUS.
00236 M00S00226.1lc +++|*
00237 M00S00227.1lc +++|* CALLS FNC.
00238 M00S00228.1lc +++|
00239 M00S00229.1lc +++|
Line S00001 Modification History
M01
(Added by) ns2776
Seq # *Modification Id* Act
----------------------------+
00240 M01S00001.ns2776 +++| CSS3 EJM CSS1,CH IF DATA NOT PRESENT
00241 M01S00002.ns2776 +++| LDN 1
00242 M01S00003.ns2776 +++| IAM ST,CH
00243 M01S00004.ns2776 +++| DCN CH
00244 M01S00005.ns2776 +++| NJN CSS2 IF NO STATUS RECEIVED
00245 M01S00006.ns2776 +++|
00246 M00S00230.1lc +++| CCS SUBR ENTRY/EXIT
00247 M00S00231.1lc +++| LDN FCST CHECK STATUS
00248 M00S00232.1lc +++| RJM FNC
00249 M00S00233.1lc +++| NJN CCSX IF FUNCTION TIMEOUT
00250 M00S00234.1lc +++| ACN CH
Line S00001 Modification History
M01
(Added by) 1lc6
M02
(Removed by) ns2776
Seq # *Modification Id* Act
----------------------------+
00251 M02S00001.ns2776 ---| CSS1 SBN 1
00252 M02S00002.ns2776 ---| ZJN CSS2 IF TIMEOUT WAITING FOR DATA
00253 M02S00003.ns2776 ---| EJM CSS1,CH IF DATA NOT PRESENT
Line S00235 Modification History
M01
(Removed by) ns2776
Seq # *Modification Id* Act
----------------------------+
00254 M01S00235.ns2776 ---| LDN 1
00255 M01S00236.ns2776 ---| IAM ST,CH
00256 M01S00237.ns2776 ---| DCN CH
00257 M01S00238.ns2776 ---| ZJN CCSX IF STATUS RECEIVED
Line S00007 Modification History
M01
(Added by) ns2776
Seq # *Modification Id* Act
----------------------------+
00258 M01S00007.ns2776 +++| LDD HN
00259 M01S00008.ns2776 +++| STD T0
00260 M01S00009.ns2776 +++| CSS1 ADN 1
00261 M01S00010.ns2776 +++| NJN CSS3 IF NOT TIMEOUT
00262 M01S00011.ns2776 +++| SOD T0
00263 M01S00012.ns2776 +++| NJN CSS3 IF NOT TIMEOUT
Line S00004 Modification History
M01
(Added by) 1lc6
Seq # *Modification Id* Act
----------------------------+
00264 M01S00004.1lc6 +++| CSS2 DCN CH
00265 M00S00239.1lc +++| LDN RC33 * NO GENERAL STATUS RECEIVED.*
00266 M00S00240.1lc +++| UJN CCSX RETURN
00267 M00S00241.1lc +++| DCH SPACE 4,10
00268 M00S00242.1lc +++|** DCH - DROP CHANNEL ASSIGNMENT.
00269 M00S00243.1lc +++|*
00270 M00S00244.1lc +++|* ENTRY (BC) = CHANNEL NUMBER.
00271 M00S00245.1lc +++|* (CF) = 0 IF CHANNEL NOT RESERVED BY *1LC*.
00272 M00S00246.1lc +++|*
00273 M00S00247.1lc +++|* EXIT (CF) = 0.
00274 M00S00248.1lc +++|*
00275 M00S00249.1lc +++|* MACROS DCHAN.
00276 M00S00250.1lc +++|
00277 M00S00251.1lc +++|
00278 M00S00252.1lc +++| DCH SUBR ENTRY/EXIT
00279 M00S00253.1lc +++| LDD CF
00280 M00S00254.1lc +++| ZJN DCHX IF CHANNEL NOT RESERVED BY *1LC*
00281 M00S00255.1lc +++| LDD BC
00282 M00S00256.1lc +++| DCHAN
00283 M00S00257.1lc +++|* LDN 0
00284 M00S00258.1lc +++| STD CF
00285 M00S00259.1lc +++| UJN DCHX RETURN
00286 M00S00260.1lc +++| DCT SPACE 4,15
00287 M00S00261.1lc +++|** DCT - DUMP CONTROLLER MEMORY.
00288 M00S00262.1lc +++|*
00289 M00S00263.1lc +++|* ENTRY (CT) = CHANNEL CONTROLWARE ENTRY.
00290 M00S00264.1lc +++|* (DB - DB+4) = DUMP FET *IN* POINTER (SET TO *FIRST*).
00291 M00S00265.1lc +++|* (DR) = *DR4* (CONTROLLER DUMP UNSUCCESSFUL) STATUS.
00292 M00S00266.1lc +++|*
00293 M00S00267.1lc +++|* EXIT (DR) = DUMP FET RESPONSE CODE.
00294 M00S00268.1lc +++|*
00295 M00S00269.1lc +++|* USES T1, T2, T3, T4, CM - CM+4.
00296 M00S00270.1lc +++|*
00297 M00S00271.1lc +++|* CALLS D7C, FNC, GDA, SDR, WBC.
00298 M00S00272.1lc +++|
00299 M00S00273.1lc +++|
00300 M00S00274.1lc +++| DCT8 RJM D7C DUMP 7165 CONTROLLER MEMORY
00301 M00S00275.1lc +++| NJN DCTX IF DUMP NOT SUCCESSFUL
00302 M00S00276.1lc +++| DCT9 RJM GDA GET DUMP FET ADDRESS
00303 M00S00277.1lc +++| ADN 2 UPDATE DUMP FET *IN* POINTER
00304 M00S00278.1lc +++| CWD DB
00305 M00S00279.1lc +++| LDN DR0
00306 M00S00280.1lc +++| DCT10 STD DR SAVE DUMP FET RESPONSE CODE
00307 M00S00281.1lc +++|
00308 M00S00282.1lc +++| DCT SUBR ENTRY/EXIT
00309 M00S00283.1lc +++| RJM GDA GET DUMP FET ADDRESS
00310 M00S00284.1lc +++| ZJN DCTX IF NO DUMP REQUESTED
00311 M00S00285.1lc +++| LDN ZERL CLEAR MANIPULATE PROCESSOR PARAMETERS
00312 M00S00286.1lc +++| CRD CM
00313 M00S00287.1lc +++| LDN 2 SET TO DUMP CONTROLLER MEMORY
00314 M00S00288.1lc +++| STD CM
00315 M00S00289.1lc +++| STD T4 PRESET 8K CONTROLLER TYPE INDEX
00316 M00S00290.1lc +++| LDD CT CHECK CONTROLWARE TYPE
00317 M00S00291.1lc +++| LPN 37
00318 M00S00292.1lc +++| LMN FMCW
00319 M00S00293.1lc +++| ZJN DCT1 IF MA721 CONTROLWARE FOR 7155 FMD
00320 M00S00294.1lc +++| LMN PHCW&FMCW
00321 M00S00295.1lc +++| ZJN DCT1 IF MA722 CONTROLWARE FOR 7155 DEMA
00322 M00S00296.1lc +++| LMN CCCW&PHCW
00323 M00S00297.1lc +++| ZJN DCT8 IF 7165 CONTROLLER
00324 M00S00298.1lc +++| LMN IDCW&CCCW
00325 M00S00299.1lc +++| ZJN DCT0 IF 7255 ADAPTOR
00326 M00S00300.1lc +++| LDN DR3 * NOT CORRECT CONTROLLER TYPE FOR DUMP.*
00327 M00S00301.1lc +++| UJN DCT10 SAVE RESPONSE CODE
00328 M00S00302.1lc +++|
00329 M00S00303.1lc +++| DCT0 LDN 40 SET 7255 ADAPTOR MEMORY ADDRESS
00330 M00S00304.1lc +++| STD CM+1
00331 M00S00305.1lc +++| SHN 1 SET MEMORY ADDRESS INCREMENT
00332 M00S00306.1lc +++| STM DCTB
00333 M00S00307.1lc +++| LDN 1 SET 7255 CONTROLLER TYPE INDEX
00334 M00S00308.1lc +++| STD T4
00335 M00S00309.1lc +++| DCT1 LDK NFBT SET NUMBER OF FULL BUFFERS
00336 M00S00310.1lc +++| STD T2
00337 M00S00311.1lc +++| LDK CWFB SET CM WORDS IN FULL BUFFER
00338 M00S00312.1lc +++| STD T3
00339 M00S00313.1lc +++| DCT2 LDK MXDB SET NUMBER OF BLOCKS IN FULL BUFFER
00340 M00S00314.1lc +++| STD T1
00341 M00S00315.1lc +++| DCT3 LDC DBUF RESET PP DUMP BUFFER ADDRESS
00342 M00S00316.1lc +++| STM DCTA
00343 M00S00317.1lc +++| DCT4 LDN FCMP INITIATE MANIPULATE PROCESSOR FUNCTION
00344 M00S00318.1lc +++| RJM FNC
00345 M00S00319.1lc +++| DCT5 NJP DCTX IF FUNCTION TIMEOUT
00346 M00S00320.1lc +++| ACN CH
00347 M00S00321.1lc +++| LDN 5 TRANSFER PARAMETERS
00348 M00S00322.1lc +++| OAM CM,CH
00349 M00S00323.1lc +++| FJM *,CH IF CHANNEL FULL
00350 M00S00324.1lc +++| DCN CH
00351 M00S00325.1lc +++| NJN DCT5 IF NOT ALL PARAMETERS TAKEN
00352 M00S00326.1lc +++| LDN FCDM DUMP CONTROLLER MEMORY
00353 M00S00327.1lc +++| RJM FNC
00354 M00S00328.1lc +++| NJN DCT5 IF FUNCTION TIMEOUT
00355 M00S00329.1lc +++| ACN CH
00356 M00S00330.1lc +++| LDD HN
00357 M00S00331.1lc +++| ERRNZ PBDB-100B CODE DEPENDS ON VALUE
00358 M00S00332.1lc +++| IAM DBUF,CH READ CONTROLLER MEMORY DUMP BLOCK
00359 M00S00333.1lc +++| DCTA EQU *-1
00360 M00S00334.1lc +++| NJN DCT5 IF NOT ALL DATA TRANSFERRED
00361 M00S00335.1lc +++| LDD HN ADVANCE PP DUMP BUFFER ADDRESS
00362 M00S00336.1lc +++| RAM DCTA
00363 M00S00337.1lc +++| LDC CWDB ADVANCE CONTROLLER MEMORY ADDRESS
00364 M00S00338.1lc +++| DCTB EQU *-1
00365 M00S00339.1lc +++|* LDC 100 (ADVANCE 7255 ADAPTOR ADDRESS)
00366 M00S00340.1lc +++| RAD CM+2
00367 M00S00341.1lc +++| SHN 21-10
00368 M00S00342.1lc +++| PJN DCT6 IF NOT 8 BIT OVERFLOW
00369 M00S00343.1lc +++| STD CM+2 CLEAR LOWER 8 BITS OF CONTROLLER ADDRESS
00370 M00S00344.1lc +++| AOD CM+1 INCREMENT UPPER 8 BITS OF ADDRESS
00371 M00S00345.1lc +++| DCT6 SOD T1
00372 M00S00346.1lc +++| NJP DCT4 IF MORE BLOCKS TO TRANSFER TO BUFFER
00373 M00S00347.1lc +++| RJM WBC WRITE BUFFER TO CM
00374 M00S00348.1lc +++| SOD T2
00375 M00S00349.1lc +++| MJN DCT7 IF DUMP COMPLETE
00376 M00S00350.1lc +++| NJP DCT2 IF MORE FULL BUFFERS TO DUMP
00377 M00S00351.1lc +++| LDK RPBB SET REMAINING PARTIAL BUFFER BLOCKS
00378 M00S00352.1lc +++| ZJN DCT7 IF NO PARTIAL BUFFER
00379 M00S00353.1lc +++| STD T1
00380 M00S00354.1lc +++| LDK CWPB SET CM WORDS IN LAST PARTIAL BUFFER
00381 M00S00355.1lc +++| STD T3
00382 M00S00356.1lc +++| LDN ZERL CLEAR LAST CM WORD
00383 M00S00357.1lc +++| CRM DBUF+RPBB*PBDB,ON
00384 M00S00358.1lc +++| LJM DCT3 TRANSFER LAST PARTIAL BUFFER
00385 M00S00359.1lc +++|
00386 M00S00360.1lc +++| DCT7 LJM DCT9 UPDATE FET
00387 M00S00361.1lc +++| D7C SPACE 4,10
00388 M00S00362.1lc +++|** D7C - DUMP 7165 CONTROLLER MEMORY.
00389 M00S00363.1lc +++|*
00390 M00S00364.1lc +++|* ENTRY (CM+1) = 0.
00391 M00S00365.1lc +++|*
00392 M00S00366.1lc +++|* EXIT (A) = 0 IF DUMP SUCCESSFUL.
00393 M00S00367.1lc +++|*
00394 M00S00368.1lc +++|* USES CM+1, T1, T2, T3, T4.
00395 M00S00369.1lc +++|*
00396 M00S00370.1lc +++|* CALLS FNC, WBC.
00397 M00S00371.1lc +++|
00398 M00S00372.1lc +++|
00399 M00S00373.1lc +++| D7C SUBR ENTRY/EXIT
00400 M00S00374.1lc +++| LDN 4 SET 7165 CONTROLLER TYPE INDEX
00401 M00S00375.1lc +++| STD T4
00402 M00S00376.1lc +++| LDN NBBD SET NUMBER OF CONTROLLER BLOCKS TO DUMP
00403 M00S00377.1lc +++| STD T2
00404 M00S00378.1lc +++| LDK CMWF SET NUMBER OF CM WORDS IN FULL BUFFER
00405 M00S00379.1lc +++| STD T3
00406 M00S00380.1lc +++| LDK CTDB SET NUMBER OF CONTROLLER WORDS IN BLOCK
00407 M00S00381.1lc +++| STD T1
00408 M00S00382.1lc +++| D7C1 LDC FCLA LOAD ADDRESS AND LENGTH
00409 M00S00383.1lc +++| D7CA EQU *-1
00410 M00S00384.1lc +++| RJM FNC
00411 M00S00385.1lc +++| D7C2 NJN D7CX IF FUNCTION TIMEOUT
00412 M00S00386.1lc +++| ACN CH
00413 M00S00387.1lc +++| LDD CM+1 SEND BOTTOM 12 BITS OF ADDRESS
00414 M00S00388.1lc +++| OAN CH
00415 M00S00389.1lc +++| LDD T1 SEND LENGTH
00416 M00S00390.1lc +++| OAN CH
00417 M00S00391.1lc +++| FJM *,CH
00418 M00S00392.1lc +++| DCN CH
00419 M00S00393.1lc +++| LDC FCDC ISSUE DIAGNOSTIC READ
00420 M00S00394.1lc +++| RJM FNC
00421 M00S00395.1lc +++| NJN D7CX IF FUNCTION TIMEOUT
00422 M00S00396.1lc +++| ACN CH
00423 M00S00397.1lc +++| LDD T1
00424 M00S00398.1lc +++| SHN 1
00425 M00S00399.1lc +++| IAM DBUF,CH READ CONTROLLER MEMORY BLOCK
00426 M00S00400.1lc +++| NJN D7C2 IF NOT ALL DATA TRANSFERRED
00427 M00S00401.1lc +++| RJM WBC WRITE BUFFER TO CM
00428 M00S00402.1lc +++| SOD T2
00429 M00S00403.1lc +++| PJN D7C3 IF DUMP NOT COMPLETE
00430 M00S00404.1lc +++| LDN 0
00431 M00S00405.1lc +++| LJM D7CX RETURN
00432 M00S00406.1lc +++|
00433 M00S00407.1lc +++| D7C3 LDC CTDB UPDATE CONTROLLER MEMORY ADDRESS
00434 M00S00408.1lc +++| RAD CM+1
00435 M00S00409.1lc +++| SHN -14
00436 M00S00410.1lc +++| RAM D7CA
00437 M00S00411.1lc +++| LDD T2
00438 M00S00412.1lc +++| NJN D7C4 IF MORE FULL BLOCKS TO DUMP
00439 M00S00413.1lc +++| LDK CMWP SET NUMBER OF CM WORDS IN PARTIAL BLOCK
00440 M00S00414.1lc +++| STD T3
00441 M00S00415.1lc +++| LDK CTPB SET NUMBER OF PP BYTES IN PARTIAL BLOCK
00442 M00S00416.1lc +++| STD T1
00443 M00S00417.1lc +++| D7C4 LJM D7C1 DUMP PARTIAL BLOCK
00444 M00S00418.1lc +++| FNC SPACE 4,10
00445 M00S00419.1lc +++|** FNC - ISSUE FUNCTION.
00446 M00S00420.1lc +++|*
00447 M00S00421.1lc +++|* ENTRY (A) = FUNCTION CODE.
00448 M00S00422.1lc +++|*
00449 M00S00423.1lc +++|* EXIT (A) = 0 IF FUNCTION ACCEPTED.
00450 M00S00424.1lc +++|* (A) = *RC22* IF FUNCTION TIMEOUT.
00451 M00S00425.1lc +++|
00452 M00S00426.1lc +++|
00453 M00S00427.1lc +++| FNC3 LDN 0
00454 M00S00428.1lc +++|
00455 M00S00429.1lc +++| FNC SUBR ENTRY/EXIT
00456 M00S00430.1lc +++| STD FN SAVE FUNCTION ISSUED
00457 M00S00431.1lc +++| IJM FNC1,CH IF CONTROLLER READY
00458 M00S00432.1lc +++| DCN CH
00459 M00S00433.1lc +++| FNC1 FAN CH
Line S00013 Modification History
M01
(Added by) ns2776
Seq # *Modification Id* Act
----------------------------+
00460 M01S00013.ns2776 +++| LDD HN FUNCTION TIMEOUT OUTER DELAY
00461 M01S00014.ns2776 +++| STD T0
00462 M00S00434.1lc +++| FNC2 ADD ON
00463 M00S00435.1lc +++| IJM FNC3,CH IF FUNCTION ACCEPTED
Line S00436 Modification History
M01
(Removed by) ns2776
Seq # *Modification Id* Act
----------------------------+
00464 M01S00436.ns2776 ---| NJN FNC2 IF NOT END OF DELAY
Line S00015 Modification History
M01
(Added by) ns2776
Seq # *Modification Id* Act
----------------------------+
00465 M01S00015.ns2776 +++| NJN FNC2 IF NOT FUNCTION TIMEOUT
00466 M01S00016.ns2776 +++| SOD T0
00467 M01S00017.ns2776 +++| NJN FNC2 IF NOT FUNCTION TIMEOUT
00468 M00S00437.1lc +++| DCN CH
00469 M00S00438.1lc +++| LDN RC32 * FUNCTION TIMED OUT=NNNN.*
00470 M00S00439.1lc +++| UJN FNCX EXIT
00471 M00S00440.1lc +++| GDA SPACE 4,10
00472 M00S00441.1lc +++|** GDA - GET DUMP FET ADDRESS.
00473 M00S00442.1lc +++|*
00474 M00S00443.1lc +++|* ENTRY (IR+2 - IR+3) = DUMP FET ADDRESS.
00475 M00S00444.1lc +++|*
00476 M00S00445.1lc +++|* EXIT (A) = ABSOLUTE DUMP FET ADDRESS.
00477 M00S00446.1lc +++|* (A) = 0 IF NO DUMP REQUESTED.
00478 M00S00447.1lc +++|
00479 M00S00448.1lc +++|
00480 M00S00449.1lc +++| GDA SUBR ENTRY/EXIT
00481 M00S00450.1lc +++| LDD IR+3 GET DUMP FET ADDRESS
00482 M00S00451.1lc +++| SCN 77
00483 M00S00452.1lc +++| SHN 6
00484 M00S00453.1lc +++| ADD IR+2
00485 M00S00454.1lc +++| ZJN GDAX IF NO DUMP REQUESTED
00486 M00S00455.1lc +++| ADD RA
00487 M00S00456.1lc +++| SHN 6
00488 M00S00457.1lc +++| UJN GDAX RETURN
00489 M00S00458.1lc +++| GLA SPACE 4,10
00490 M00S00459.1lc +++|** GLA - GET LOAD FET ADDRESS.
00491 M00S00460.1lc +++|*
00492 M00S00461.1lc +++|* ENTRY (IR+3 - IR+4) = LOAD FET ADDRESS.
00493 M00S00462.1lc +++|*
00494 M00S00463.1lc +++|* EXIT (A) = ABSOLUTE LOAD FET ADDRESS.
00495 M00S00464.1lc +++|
00496 M00S00465.1lc +++|
00497 M00S00466.1lc +++| GLA SUBR ENTRY/EXIT
00498 M00S00467.1lc +++| LDD IR+3 GET LOAD FET ADDRESS
00499 M00S00468.1lc +++| LPN 37
00500 M00S00469.1lc +++| SHN 6
00501 M00S00470.1lc +++| ADD RA
00502 M00S00471.1lc +++| SHN 6
00503 M00S00472.1lc +++| ADD IR+4
00504 M00S00473.1lc +++| UJN GLAX RETURN
00505 M00S00474.1lc +++| ICE SPACE 4,10
00506 M00S00475.1lc +++|** ICE - INTERLOCK CONTROLWARE LOAD BITS.
00507 M00S00476.1lc +++|*
00508 M00S00477.1lc +++|* ENTRY (CE - CE+1) = CONTROLWARE LOAD BIT ADDRESS.
00509 M00S00478.1lc +++|* (CHTI) = CONTROLWARE INTERLOCK *UTEM* PARAMETERS.
00510 M00S00479.1lc +++|*
00511 M00S00480.1lc +++|* EXIT (CM+1) = *UTEM* RETURN STATUS.
00512 M00S00481.1lc +++|*
00513 M00S00482.1lc +++|* USES CM+1, CM+3, CM+4, T1.
00514 M00S00483.1lc +++|*
00515 M00S00484.1lc +++|* MACROS MONITOR.
00516 M00S00485.1lc +++|
00517 M00S00486.1lc +++|
00518 M00S00487.1lc +++| ICE SUBR ENTRY/EXIT
00519 M00S00488.1lc +++| LDN 2
00520 M00S00489.1lc +++| STD CM+1 SET NUMBER OF *UTEM* PARAMETER WORDS
00521 M00S00490.1lc +++| STD T1
00522 M00S00491.1lc +++| LDD CE SET CONROLWARE LOAD BIT ADDRESS
00523 M00S00492.1lc +++| STD CM+3
00524 M00S00493.1lc +++| LDD CE+1
00525 M00S00494.1lc +++| STD CM+4
00526 M00S00495.1lc +++| LDD MA
00527 M00S00496.1lc +++| CWM CHTI,T1 SET/CLEAR CONTROLWARE LOAD INTERLOCK
00528 M00S00497.1lc +++| MONITOR UTEM
00529 M00S00498.1lc +++| LDD MA GET NEW VALUES
00530 M00S00499.1lc +++| CRM CHTI,T1
00531 M00S00500.1lc +++| UJN ICEX RETURN
00532 M00S00501.1lc +++|
00533 M00S00502.1lc +++|
00534 M00S00503.1lc +++| CHTI VFD 1/1,5/0,6/2,6/34D,42/0 VERIFY INTERLOCKS
Line S00504 Modification History
M01
(Removed by) 1lc2
Seq # *Modification Id* Act
----------------------------+
00535 M01S00504.1lc2 ---|* VFD 1/1,5/0,6/3,6/30D,42/0 VERIFY RELOAD COUNT
Line S00001 Modification History
M01
(Added by) 1lc2
Seq # *Modification Id* Act
----------------------------+
00536 M01S00001.1lc2 +++|* VFD 1/1,5/0,6/4,6/30D,42/0 VERIFY RELOAD COUNT/DRIVER BIT
00537 M00S00505.1lc +++|
00538 M00S00506.1lc +++| VFD 1/0,5/0,6/1,6/34D,42/1 SET LOAD IN PROGRESS
00539 M00S00507.1lc +++|* VFD 1/0,5/0,6/5,6/30D,42/0 CLEAR INTERLOCK/SET LOAD COUNT
00540 M00S00508.1lc +++| ILF SPACE 4,10
00541 M00S00509.1lc +++|** ILF - ISSUE LOAD FUNCTION.
00542 M00S00510.1lc +++|*
00543 M00S00511.1lc +++|* ENTRY (CO) = 0 IF NOT CONTROL MODULE RELOAD.
00544 M00S00512.1lc +++|* (CS) = 0 IF DRIVER CALL.
00545 M00S00513.1lc +++|* (EQ) = CONTROL MODULE EQUIPMENT NUMBER.
00546 M00S00514.1lc +++|*
00547 M00S00515.1lc +++|* CALLS CCS, FNC.
00548 M00S00516.1lc +++|
00549 M00S00517.1lc +++|
00550 M00S00518.1lc +++| ILF2 LDD CS
00551 M00S00519.1lc +++| ILFA ZJN ILF3 IF DRIVER CALL
00552 M00S00520.1lc +++|* PSN (*FCAR* FUNCTION NOT SUPPORTED)
00553 M00S00521.1lc +++| LDC FCAL&FCAR
00554 M00S00522.1lc +++| ILF3 LMN FCAR
00555 M00S00523.1lc +++| ILF4 RJM FNC ISSUE FUNCTION
00556 M00S00524.1lc +++|
00557 M00S00525.1lc +++| ILF SUBR ENTRY/EXIT
00558 M00S00526.1lc +++| LDD CO
00559 M00S00527.1lc +++| ZJN ILF2 IF NOT CONTROL MODULE RELOAD
00560 M00S00528.1lc +++| ILF1 LDN FCCN
00561 M00S00529.1lc +++| RJM FNC ISSUE CONNECT FUNCTION
00562 M00S00530.1lc +++| NJN ILFX IF FUNCTION TIMEOUT
00563 M00S00531.1lc +++| ACN CH
00564 M00S00532.1lc +++| LDD EQ OUTPUT CONTROL MODULE EQUIPMENT NUMBER
00565 M00S00533.1lc +++| SHN 3
00566 M00S00534.1lc +++| OAN CH
00567 M00S00535.1lc +++| FJM *,CH IF CHANNEL FULL
00568 M00S00536.1lc +++| DCN CH
00569 M00S00537.1lc +++| RJM CCS STATUS CONTROLLER
00570 M00S00538.1lc +++| NJN ILFX IF ERROR
00571 M00S00539.1lc +++| LDD ST
00572 M00S00540.1lc +++| NJN ILF1 IF GENERAL STATUS NOT ZERO
00573 M00S00541.1lc +++| LDN FCLC
00574 M00S00542.1lc +++| UJN ILF4 ISSUE CONTROLWARE LOAD FROM PP FUNCTION
00575 M00S00543.1lc +++| LCT SPACE 4,15
00576 M00S00544.1lc +++|** LCT - LOAD CONTROLWARE TO CONTROLLER.
00577 M00S00545.1lc +++|*
00578 M00S00546.1lc +++|* ENTRY (CS) = CHANNEL SPECIFIED ON CALL STATUS.
00579 M00S00547.1lc +++|* (DP+3 - DP+4) = FWA CONTROLWARE RECORD (77 TABLE).
00580 M00S00548.1lc +++|* (EQ) = CONTROL MODULE EQUIPMENT NUMBER IF SPECIFIED.
00581 M00S00549.1lc +++|* (WC) = CM WORD COUNT OF CONTROLWARE RECORD.
00582 M00S00550.1lc +++|*
00583 M00S00551.1lc +++|* EXIT (A) = 0 IF LOAD COMPLETE.
Line S00552 Modification History
M01
(Removed by) ns2776
Seq # *Modification Id* Act
----------------------------+
00584 M01S00552.ns2776 ---|* (A) = *RC20* IF CONTROLLER DID NOT TAKE ALL
Line S00018 Modification History
M01
(Added by) ns2776
Seq # *Modification Id* Act
----------------------------+
00585 M01S00018.ns2776 +++|* (A) = *RC30* IF CONTROLLER DID NOT TAKE ALL
00586 M00S00553.1lc +++|* CONTROLWARE.
00587 M00S00554.1lc +++|* (A) = *RC22* IF FUNCTION TIMEOUT.
00588 M00S00555.1lc +++|* (A) = *RC23* IF STATUS NOT RECEIVED.
00589 M00S00556.1lc +++|*
00590 M00S00557.1lc +++|* USES T1, WC, DP+3 - DP+4.
00591 M00S00558.1lc +++|*
00592 M00S00559.1lc +++|* CALLS CCS, ILF.
00593 M00S00560.1lc +++|
00594 M00S00561.1lc +++|
00595 M00S00562.1lc +++| LCT4 FJM *,CH IF LAST WORD STILL ON CHANNEL
00596 M00S00563.1lc +++| DCN CH
00597 M00S00564.1lc +++| LCT5 DELAY
00598 M00S00565.1lc +++| RJM CCS CHECK STATUS
00599 M00S00566.1lc +++| NJN LCTX IF ERROR
00600 M00S00567.1lc +++| LDD ST
00601 M00S00568.1lc +++| SBN 2
00602 M00S00569.1lc +++| ZJN LCT5 IF CONTROLLER BUSY
00603 M00S00570.1lc +++| LDN 0
00604 M00S00571.1lc +++|
00605 M00S00572.1lc +++| LCT SUBR ENTRY/EXIT
00606 M00S00573.1lc +++| RJM ILF ISSUE LOAD FUNCTION
00607 M00S00574.1lc +++| NJN LCTX IF FUNCTION TIMEOUT
00608 M00S00575.1lc +++| LDD RA
00609 M00S00576.1lc +++| SHN 6
00610 M00S00577.1lc +++| RAD DP+4
00611 M00S00578.1lc +++| SHN -14
00612 M00S00579.1lc +++| RAD DP+3
00613 M00S00580.1lc +++| LDD TH
00614 M00S00581.1lc +++| ERRNZ BUFL-1000 CODE DEPENDS ON VALUE
00615 M00S00582.1lc +++| STD T1
00616 M00S00583.1lc +++| ACN CH ACTIVATE CHANNEL FOR OUTPUT
00617 M00S00584.1lc +++| LCT2 LDD WC SET BLOCK WORD COUNT
00618 M00S00585.1lc +++| ZJN LCT4 IF END OF CONTROLWARE
00619 M00S00586.1lc +++| SBD T1
00620 M00S00587.1lc +++| PJN LCT3 IF DATA OVERFLOWS BUFFER
00621 M00S00588.1lc +++| LDD WC
00622 M00S00589.1lc +++| STD T1
00623 M00S00590.1lc +++| LDN 0
00624 M00S00591.1lc +++| LCT3 STD WC
00625 M00S00592.1lc +++| LDD DP+3 SET CONTROLWARE DATA ADDRESS
00626 M00S00593.1lc +++| SHN 14
00627 M00S00594.1lc +++| ADD DP+4
00628 M00S00595.1lc +++| CRM BUF,T1 READ BLOCK OF CONTROLWARE
00629 M00S00596.1lc +++| STD DP+4 SAVE NEXT CM ADDRESS FOR CONTROLWARE READ
00630 M00S00597.1lc +++| SHN -14
00631 M00S00598.1lc +++| STD DP+3
00632 M00S00599.1lc +++| LDD T1 OUTPUT BLOCK TO CONTROLLER
00633 M00S00600.1lc +++| SHN 2
00634 M00S00601.1lc +++| ADD T1
00635 M00S00602.1lc +++| OAM BUF,CH
00636 M00S00603.1lc +++| FJM *,CH IF CHANNEL FULL
00637 M00S00604.1lc +++| ZJN LCT2 IF ALL DATA TAKEN
00638 M00S00605.1lc +++| LDN RC30 * CONTROLLER DID NOT TAKE ALL CONTROLWARE*
00639 M00S00606.1lc +++| LJM LCTX RETURN
00640 M00S00607.1lc +++| RCT SPACE 4,10
00641 M00S00608.1lc +++|** RCT - READ CHANNEL TABLE.
00642 M00S00609.1lc +++|*
00643 M00S00610.1lc +++|* ENTRY (A) = CHANNEL NUMBER.
00644 M00S00611.1lc +++|*
00645 M00S00612.1lc +++|* EXIT (A) = ADDRESS OF CHANNEL RESERVATION TABLE WORD.
00646 M00S00613.1lc +++|* (BC) = CHANNEL NUMBER.
00647 M00S00614.1lc +++|* (T6) = BYTE ADDRESS OF CHANNEL RESERVATION STATUS.
00648 M00S00615.1lc +++|* (CM - CM+4) = CHANNEL RESERVATION TABLE WORD.
00649 M00S00616.1lc +++|*
00650 M00S00617.1lc +++|* USES T0.
00651 M00S00618.1lc +++|
00652 M00S00619.1lc +++|
00653 M00S00620.1lc +++| RCT SUBR ENTRY/EXIT
Line S00621 Modification History
M01
(Removed by) 252l678
Seq # *Modification Id* Act
----------------------------+
00654 M01S00621.252l678 ---| LPN 37
Line S00001 Modification History
M01
(Added by) 252l678
Seq # *Modification Id* Act
----------------------------+
00655 M01S00001.252l678 +++| LPN 77
00656 M00S00622.1lc +++| STD BC
00657 M00S00623.1lc +++| STD T6
00658 M00S00624.1lc +++| LCN 0
00659 M00S00625.1lc +++| STD T0
00660 M00S00626.1lc +++| LDK CHTP GET CHANNEL TABLE ADDRESS
00661 M00S00627.1lc +++| CRD CM
00662 M00S00628.1lc +++| RCT1 AOD T0
00663 M00S00629.1lc +++| LCN 5
00664 M00S00630.1lc +++| RAD T6
00665 M00S00631.1lc +++| PJN RCT1 IF CHANNEL WORD NOT REACHED
00666 M00S00632.1lc +++| ADN CM+5
00667 M00S00633.1lc +++| STD T6
00668 M00S00634.1lc +++| LDD CM+2 READ CHANNEL RESERVATION TABLE
00669 M00S00635.1lc +++| SHN 14
00670 M00S00636.1lc +++| LMD CM+3
00671 M00S00637.1lc +++| ADD T0
00672 M00S00638.1lc +++| CRD CM
00673 M00S00639.1lc +++| UJN RCTX RETURN
Line S00640 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00674 M01S00640.1lc5 ---| RSC SPACE 4,15
00675 M01S00641.1lc5 ---|** RSC - RESERVE AND STATUS CHANNEL.
00676 M01S00642.1lc5 ---|*
00677 M01S00643.1lc5 ---|* ENTRY (BC) = CHANNEL NUMBER.
00678 M01S00644.1lc5 ---|* = *RC2* IF DOWN CHANNEL IN USE.
00679 M01S00645.1lc5 ---|* = *RC34* IF CONTROLLER RESERVED.
00680 M01S00646.1lc5 ---|* (CS) = CHANNEL SPECIFIED ON CALL STATUS.
00681 M01S00647.1lc5 ---|*
00682 M01S00648.1lc5 ---|* EXIT (A) = 0.
00683 M01S00649.1lc5 ---|* (A) = *RC24* IF CONTROLLER RESERVED THROUGH
Line S00650 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00684 M02S00650.1lc5 ---|* ALTERNATE ACCESS.
Line S00002 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00685 M02S00002.1lc5 ---|* ALTERNATE ACCESS OR *RC22* IF FUNCTION
00686 M02S00003.1lc5 ---|* TIMEOUT OCCURED.
Line S00651 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00687 M01S00651.1lc5 ---|* CHANNEL RESERVED IF NOT SYSTEM REQUEST.
Line S00652 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00688 M02S00652.1lc5 ---|*
00689 M02S00653.1lc5 ---|* ERROR EXIT TO *LCW4* IF DOWN CHANNEL ALREADY IN USE.
00690 M02S00654.1lc5 ---|* (RC) = *RC2*.
00691 M02S00655.1lc5 ---|* CHANNEL NOT RESERVED.
Line S00656 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00692 M01S00656.1lc5 ---|*
00693 M01S00657.1lc5 ---|* USES CM - CM+4.
00694 M01S00658.1lc5 ---|*
Line S00659 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00695 M02S00659.1lc5 ---|* CALLS CCS, RCT.
Line S00004 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00696 M02S00004.1lc5 ---|* CALLS CCS, FNC, RCT.
Line S00660 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00697 M01S00660.1lc5 ---|*
00698 M01S00661.1lc5 ---|* MACROS MONITOR, RCHAN.
00699 M01S00662.1lc5 ---|
00700 M01S00663.1lc5 ---|
00701 M01S00664.1lc5 ---| RSC2 LDD BC
00702 M01S00665.1lc5 ---| RCHAN RESERVE CHANNEL
00703 M01S00666.1lc5 ---| RSC3 AOD CF SET CHANNEL RESERVED BY *1LC* FLAG
Line S00667 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00704 M02S00667.1lc5 ---| RSC4 RJM CCS CHECK CONTROLLER STATUS
Line S00005 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00705 M02S00005.1lc5 ---| RSC4 LDD BC
00706 M02S00006.1lc5 ---| LPN 40
00707 M02S00007.1lc5 ---| ZJN RSC4.1 IF NOT A CIO CHANNEL
00708 M02S00008.1lc5 ---| LDC 100000 MASTER CLEAR THE CHANNEL
00709 M02S00009.1lc5 ---| RJM FNC
00710 M02S00010.1lc5 ---| NJN RSCX IF ERROR OCCURRED
00711 M02S00011.1lc5 ---| RSC4.1 RJM CCS CHECK CONTROLLER STATUS
Line S00668 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00712 M01S00668.1lc5 ---| NJN RSC5 IF STATUS TIMEOUT OR STATUS NOT RECEIVED
00713 M01S00669.1lc5 ---| LDD ST
00714 M01S00670.1lc5 ---| RSC5 LPC 2000
00715 M01S00671.1lc5 ---| ZJN RSCX IF CONTROLLER NOT ALREADY RESERVED
00716 M01S00672.1lc5 ---| LDN RC34 * CHXX, CONTROLLER RESERVED.*
00717 M01S00673.1lc5 ---|
00718 M01S00674.1lc5 ---| RSC SUBR ENTRY/EXIT
00719 M01S00675.1lc5 ---| LDD CS
00720 M01S00676.1lc5 ---| ZJN RSC4 IF DRIVER CALL
00721 M01S00677.1lc5 ---| LDD BC
00722 M01S00678.1lc5 ---| RJM RCT READ CHANNEL TABLE
00723 M01S00679.1lc5 ---| LDI T6
00724 M01S00680.1lc5 ---| LPN 40
Line S00681 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00725 M02S00681.1lc5 ---| ZJN RSC2 IF CHANNEL UP
Line S00012 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00726 M02S00012.1lc5 ---| ZJP RSC2 IF CHANNEL UP
Line S00682 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00727 M01S00682.1lc5 ---| LDN 0
00728 M01S00683.1lc5 ---| STD CM+2
00729 M01S00684.1lc5 ---| LDD BC ASSIGN DOWNED CHANNEL
00730 M01S00685.1lc5 ---| STD CM+1
00731 M01S00686.1lc5 ---| MONITOR CCHM
00732 M01S00687.1lc5 ---| LDD CM+2
Line S00688 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00733 M02S00688.1lc5 ---| NJN RSC3 IF CHANNEL ASSIGNED
Line S00013 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00734 M02S00013.1lc5 ---| NJP RSC3 IF CHANNEL ASSIGNED
Line S00689 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00735 M01S00689.1lc5 ---| LDN RC2 * SPECIFIED CHANNEL IS IN USE.*
00736 M01S00690.1lc5 ---| UJN RSCX RETURN
00737 M00S00691.1lc +++| SDR SPACE 4,10
00738 M00S00692.1lc +++|** SDR - SET DUMP FET RESPONSE.
00739 M00S00693.1lc +++|*
00740 M00S00694.1lc +++|* ENTRY (DR) = DUMP FET RESPONSE CODE.
00741 M00S00695.1lc +++|* (IR+2 - IR+3) = DUMP FET ADDRESS.
00742 M00S00696.1lc +++|*
00743 M00S00697.1lc +++|* EXIT (IR+2 - IR+3) = DUMP FET ADDRESS CLEARED.
00744 M00S00698.1lc +++|*
00745 M00S00699.1lc +++|* USES CM - CM+4.
00746 M00S00700.1lc +++|*
00747 M00S00701.1lc +++|* CALLS GDA.
00748 M00S00702.1lc +++|
00749 M00S00703.1lc +++|
00750 M00S00704.1lc +++| SDR SUBR ENTRY/EXIT
00751 M00S00705.1lc +++| RJM GDA GET DUMP FET ADDRESS
00752 M00S00706.1lc +++| ZJN SDRX IF NO DUMP REQUESTED
00753 M00S00707.1lc +++| CRD CM
00754 M00S00708.1lc +++| LDD DR RETURN RESPONSE CODE
00755 M00S00709.1lc +++| SHN 1
00756 M00S00710.1lc +++| LMN 1 SET COMPLETE BIT
00757 M00S00711.1lc +++| STD CM+4
00758 M00S00712.1lc +++| RJM GDA
00759 M00S00713.1lc +++| CWD CM
00760 M00S00714.1lc +++| LDN 0 CLEAR DUMP FET ADDRESS
00761 M00S00715.1lc +++| STD IR+2
00762 M00S00716.1lc +++| LDD IR+3
00763 M00S00717.1lc +++| LPN 77
00764 M00S00718.1lc +++| STD IR+3
00765 M00S00719.1lc +++| UJN SDRX RETURN
00766 M00S00720.1lc +++| WBC SPACE 4,10
00767 M00S00721.1lc +++|** WBC - WRITE DUMP BUFFER TO CM.
00768 M00S00722.1lc +++|*
00769 M00S00723.1lc +++|* ENTRY (T3) = NUMBER OF CM WORDS IN BUFFER BLOCK.
00770 M00S00724.1lc +++|* (T4) = CONTROLLER TYPE INDEX IF FIRST BLOCK.
00771 M00S00725.1lc +++|* = 0 IF FIRST BLOCK ALREADY WRITTEN.
00772 M00S00726.1lc +++|* (DB+3 - DB+4) = DUMP FET *IN* POINTER.
00773 M00S00727.1lc +++|*
00774 M00S00728.1lc +++|* EXIT BUFFER BLOCK WRITTEN TO CM.
00775 M00S00729.1lc +++|* DUMP FET *IN* POINTER UPDATED.
00776 M00S00730.1lc +++|
00777 M00S00731.1lc +++|
00778 M00S00732.1lc +++| WBC SUBR ENTRY/EXIT
00779 M00S00733.1lc +++| LDD T4 SET CONTROLLER TYPE INDEX IN BYTE 0
00780 M00S00734.1lc +++| ZJN WBC1 IF NOT FIRST BLOCK
00781 M00S00735.1lc +++| STM BUF
00782 M00S00736.1lc +++| LDN 0 SET FIRST BLOCK WRITTEN
00783 M00S00737.1lc +++| STD T4
00784 M00S00738.1lc +++| WBC1 LDD DB+3 WRITE BUFFER TO CM
00785 M00S00739.1lc +++| SHN 6
00786 M00S00740.1lc +++| ADD RA
00787 M00S00741.1lc +++| SHN 6
00788 M00S00742.1lc +++| ADD DB+4
00789 M00S00743.1lc +++| CWM DBUF,T3
00790 M00S00744.1lc +++| LDD T3 ADVANCE DUMP FET *IN* POINTER
00791 M00S00745.1lc +++| RAD DB+4
00792 M00S00746.1lc +++| SHN -14
00793 M00S00747.1lc +++| RAD DB+3
00794 M00S00748.1lc +++| UJN WBCX RETURN
00795 M00S00749.1lc +++| TITLE BUFFERS.
00796 M00S00750.1lc +++| USE BUFFERS
00797 M00S00751.1lc +++| USE *
00798 M00S00752.1lc +++|
00799 M00S00753.1lc +++|
00800 M00S00754.1lc +++| BUF EQU * CONTROLWARE LOAD BUFFER
00801 M00S00755.1lc +++|
00802 M00S00756.1lc +++| ERRNG EPFW-BUF-BUFL PPU MEMORY OVERFLOW
00803 M00S00757.1lc +++|
00804 M00S00758.1lc +++|
00805 M00S00759.1lc +++| DBUF EQU * CONTROLLER DUMP BUFFER
00806 M00S00760.1lc +++| DBUFL EQU EPFW-DBUF-5 MAXIMUM BUFFER SIZE
00807 M00S00761.1lc +++|
00808 M00S00762.1lc +++|* 7155 DUMP BUFFER ASSEMBLY CONSTANTS.
00809 M00S00763.1lc +++|
00810 M00S00764.1lc +++| MXDB EQU DBUFL/PBDB/5*5 MAXIMUM 7155 DUMP BLOCKS IN PP BUFFER
00811 M00S00765.1lc +++| NFBT EQU NCBD/MXDB NUMBER OF FULL BUFFERS TO TRANSFER
00812 M00S00766.1lc +++| RPBB EQU NCBD-NFBT*MXDB REMAINING PARTIAL BUFFER BLOCKS
00813 M00S00767.1lc +++| CWFB EQU MXDB*PBDB/5 CM WORDS IN FULL BUFFER
00814 M00S00768.1lc +++| PBPB EQU RPBB*PBDB+4 PP BYTES IN LAST PARTIAL BUFFER (ROUNDED)
00815 M00S00769.1lc +++| CWPB EQU PBPB/5 CM WORDS IN LAST PARTIAL BUFFER
00816 M00S00770.1lc +++|
00817 M00S00771.1lc +++|* 7165 DUMP BUFFER ASSEMBLY CONSTANTS.
00818 M00S00772.1lc +++|
00819 M00S00773.1lc +++| PPDB EQU DBUFL/12*12 PP BYTES PER FULL DUMP BLOCK
00820 M00S00774.1lc +++| CCSZ EQU 40000 7165 CONTROLLER MEMORY SIZE (16 BIT WORDS)
00821 M00S00775.1lc +++| CTDB EQU PPDB/2 CONTROLLER WORDS PER FULL DUMP BLOCK
00822 M00S00776.1lc +++| NBBD EQU CCSZ/CTDB NUMBER OF CONTROLLER BLOCKS TO DUMP
00823 M00S00777.1lc +++| CTPB EQU CCSZ-NBBD*CTDB CONTROLLER WORDS IN PARTIAL DUMP BLOCK
00824 M00S00778.1lc +++| CMWF EQU PPDB/5 NUMBER OF CM WORDS PER FULL BLOCK
00825 M00S00779.1lc +++| CPPB EQU CTPB*2+4 PP BYTES PER PARTIAL BLOCK (ROUNDED)
00826 M00S00780.1lc +++| CMWP EQU CPPB/5 NUMBER OF CM WORDS PER PARTIAL BLOCK
00827 M00S00781.1lc +++| DBSZ EQU CMWF*NBBD+CMWP CM DUMP BUFFER SIZE
00828 M00S00782.1lc +++|
00829 M00S00783.1lc +++|
00830 M00S00784.1lc +++| OVERFLOW
00831 M00S00785.1lc +++| TITLE PRESET.
00832 M00S00786.1lc +++| PRS SPACE 4,20
00833 M00S00787.1lc +++|** PRS - PRESET LOAD CONTROLWARE.
00834 M00S00788.1lc +++|*
00835 M00S00789.1lc +++|* ENTRY (IR+2 - IR+3) = DUMP FET ADDRESS.
00836 M00S00790.1lc +++|* (IR+3 - IR+4) = LOAD FET ADDRESS.
00837 M00S00791.1lc +++|* (LOAD FET+8) BIT 2**11 = 1 IF BOTTOM 9 BITS =
00838 M00S00792.1lc +++|* CONTROL MODULE EST ORDINAL.
00839 M00S00793.1lc +++|* BIT 2**10 = 0 IF DRIVER CALL.
00840 M00S00794.1lc +++|*
00841 M00S00795.1lc +++|* EXIT (A) = ERROR RESPONSE.
00842 M00S00796.1lc +++|* (BC) = CHANNEL NUMBER.
00843 M00S00797.1lc +++|* (CS) = 0 IF DRIVER CALL.
00844 M00S00798.1lc +++|* (CT) = CHANNEL CONTROLWARE TYPE.
00845 M00S00799.1lc +++|* (CE - CE+1) = CONTROLWARE LOAD BITS POINTER.
00846 M00S00800.1lc +++|* (CHTI) SET FOR CLEAR OF CONTROLWARE TABLE INTERLOCK.
00847 M00S00801.1lc +++|* (DB - DB+4) = *IN* POINTER FOR DUMP FET.
00848 M00S00802.1lc +++|* (DP+3 - DP+4) = FWA OF CONTROLWARE RECORD (77 TABLE).
00849 M00S00803.1lc +++|* (DR) = INITIAL DUMP FET RESPONSE.
00850 M00S00804.1lc +++|* (WC) = CM WORD COUNT OF CONTROLWARE RECORD.
00851 M00S00805.1lc +++|* IF A CHANNEL WAS SPECIFIED ON THE CALL -
00852 M00S00806.1lc +++|* (CF) = 0.
00853 M00S00807.1lc +++|* (CO) = 0.
00854 M00S00808.1lc +++|* IF A CONTROL MODULE WAS SPECIFIED ON THE CALL -
00855 M00S00809.1lc +++|* (CO) = CONTROL MODULE EST ORDINAL.
00856 M00S00810.1lc +++|* (CF) = 1 (CHANNEL RESERVED).
00857 M00S00811.1lc +++|* (EQ) = CONTROL MODULE EQUIPMENT NUMBER.
00858 M00S00812.1lc +++|*
Line S00813 Modification History
M01
(Removed by) ns2604
Seq # *Modification Id* Act
----------------------------+
00859 M01S00813.ns2604 ---|* USES T6, T7, CM - CM+4, CN - CN+4, T0 - T4.
Line S00003 Modification History
M01
(Added by) ns2604
Seq # *Modification Id* Act
----------------------------+
00860 M01S00003.ns2604 +++|* USES T6, T7, CM - CM+4, CN - CN+4, DB-2 - DB+7, T0 - T4.
00861 M00S00814.1lc +++|*
Line S00815 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00862 M01S00815.1lc5 ---|* CALLS DCH, GDA, GLA, ICE, RCT, SCC, SDR, VFP.
Line S00001 Modification History
M01
(Added by) 1lc5
Seq # *Modification Id* Act
----------------------------+
00863 M01S00001.1lc5 +++|* CALLS DCH, GDA, GLA, ICE, RCT, RSC, SCC, SDR, VFP.
00864 M00S00816.1lc +++|
00865 M00S00817.1lc +++|
00866 M00S00818.1lc +++| PRS18 LDN RC1 * USER NOT SYSTEM ORIGIN.*
00867 M00S00819.1lc +++|
00868 M00S00820.1lc +++| PRS SUBR ENTRY/EXIT
00869 M00S00821.1lc +++| LDN DR4 PRESET CONTROLLER DUMP UNSUCCESSFUL STATUS
00870 M00S00822.1lc +++| STD DR
00871 M00S00823.1lc +++| LDN 0 INITIALIZE NO CONTROL MODULE EST ORDINAL
00872 M00S00824.1lc +++| STD CO
00873 M00S00825.1lc +++| STD CF INITIALIZE NO CHANNEL RESERVED
00874 M00S00826.1lc +++| LDD IR+3 VALIDATE CONTROLWARE LOAD FET
00875 M00S00827.1lc +++| LPN 77
00876 M00S00828.1lc +++| SHN 14
00877 M00S00829.1lc +++| ADD IR+4
00878 M00S00830.1lc +++| RJM VFP
00879 M00S00831.1lc +++| NJN PRS1 IF INVALID BUFFER PARAMETERS
00880 M00S00832.1lc +++| LDD CP
00881 M00S00833.1lc +++| ADK JOTW
00882 M00S00834.1lc +++| CRD CM
00883 M00S00835.1lc +++| LDD CM+3
00884 M00S00836.1lc +++| LMK SYOT
00885 M00S00837.1lc +++| NJN PRS18 IF NOT SYSTEM ORIGIN
00886 M00S00838.1lc +++| LDD MA GET LOAD FET PARAMETERS
00887 M00S00839.1lc +++| ADN 2
00888 M00S00840.1lc +++| CRD DP *IN* AND *OUT* POINTERS
00889 M00S00841.1lc +++| ADN 1
00890 M00S00842.1lc +++| CRD CM GET FET LENGTH
00891 M00S00843.1lc +++| LDD CM
00892 M00S00844.1lc +++| LPN 77
00893 M00S00845.1lc +++| SBN 4
00894 M00S00846.1lc +++| PJN PRS2 IF LOAD FET LONG ENOUGH
00895 M00S00847.1lc +++| PRS1 LDN RC12 * BUFFER ARGUMENT ERROR.*
00896 M00S00848.1lc +++| UJN PRSX RETURN
00897 M00S00849.1lc +++|
00898 M00S00850.1lc +++| PRS2 LDD IR+3 VALIDATE CONTROLWARE DUMP FET
00899 M00S00851.1lc +++| SCN 77
00900 M00S00852.1lc +++| SHN 6
00901 M00S00853.1lc +++| LMD IR+2
00902 M00S00854.1lc +++| SHN 6
00903 M00S00855.1lc +++| ZJN PRS4 IF NO CONTROLLER DUMP REQUESTED
00904 M00S00856.1lc +++| RJM VFP
00905 M00S00857.1lc +++| NJN PRS3 IF INVALID BUFFER PARAMETERS
00906 M00S00858.1lc +++| LDD MA GET DUMP FET PARAMETERS
00907 M00S00859.1lc +++| ADN 3
00908 M00S00860.1lc +++| CRD DB+2 *FIRST* AND *LIMIT* POINTERS
00909 M00S00861.1lc +++| LDN ZERL
00910 M00S00862.1lc +++| CRD DB-2
00911 M00S00863.1lc +++| RJM GDA GET DUMP FET ADDRESS
00912 M00S00864.1lc +++| ADN 2 REWIND FET (SET *IN* = *OUT* = *FIRST*)
00913 M00S00865.1lc +++| CWD DB
00914 M00S00866.1lc +++| ADN 1
00915 M00S00867.1lc +++| CWD DB
00916 M00S00868.1lc +++| LDD DB+2+3 VERIFY DUMP BUFFER SIZE
00917 M00S00869.1lc +++| SBD DB+2+1
00918 M00S00870.1lc +++| SHN 14
00919 M00S00871.1lc +++| ADD DB+2+4
00920 M00S00872.1lc +++| SBD DB+2+2
00921 M00S00873.1lc +++| SBK DBSZ+1 REQUIRED CM DUMP BUFFER SIZE
00922 M00S00874.1lc +++| PJN PRS4 IF DUMP BUFFER LARGE ENOUGH
00923 M00S00875.1lc +++| LDN DR2 * INSUFFICIENT DUMP BUFFER SPACE.*
00924 M00S00876.1lc +++| PRS3 STD DR
00925 M00S00877.1lc +++| RJM SDR SET DUMP FET RESPONSE
00926 M00S00878.1lc +++| PRS4 LDD DP+3 LOAD FET *OUT* POINTER
00927 M00S00879.1lc +++| SHN 6
00928 M00S00880.1lc +++| ADD RA
00929 M00S00881.1lc +++| SHN 6
00930 M00S00882.1lc +++| ADD DP+4
00931 M00S00883.1lc +++| CRD CM
00932 M00S00884.1lc +++| LDD CM
00933 M00S00885.1lc +++| LMC 7700
00934 M00S00886.1lc +++| ZJN PRS5 IF 77 TABLE PRESENT
00935 M00S00887.1lc +++| LDN RC15 * NO 77 TABLE IN CONTROLWARE RECORD.*
00936 M00S00888.1lc +++| UJN PRS6 RETURN
00937 M00S00889.1lc +++|
00938 M00S00890.1lc +++| PRS5 LDD DP+3
00939 M00S00891.1lc +++| SHN 6
00940 M00S00892.1lc +++| ADD RA
00941 M00S00893.1lc +++| SHN 6
00942 M00S00894.1lc +++| ADD DP+4
00943 M00S00895.1lc +++| ADD CM+1 ADD 77 TABLE LENGTH
00944 M00S00896.1lc +++| ADN 1
00945 M00S00897.1lc +++| CRD CN READ EXPECTED 52 TABLE
00946 M00S00898.1lc +++| LDD CN
00947 M00S00899.1lc +++| LMC 5200
00948 M00S00900.1lc +++| ZJN PRS7 IF 52 TABLE PRESENT
00949 M00S00901.1lc +++| LDN RC16 * NO 52 TABLE IN CONTROLWARE RECORD.*
00950 M00S00902.1lc +++| PRS6 LJM PRSX RETURN
00951 M00S00903.1lc +++|
00952 M00S00904.1lc +++| PRS7 STD CE+1 CLEAR CHANNEL ENTRY POINTER
00953 M00S00905.1lc +++| LDD DP+3
00954 M00S00906.1lc +++| SHN 14
00955 M00S00907.1lc +++| ADD DP+4
00956 M00S00908.1lc +++| ADD CM+1 ADD 77 TABLE LENGTH - 1
00957 M00S00909.1lc +++| ADN 2 52 TABLE ADDRESS + LENGTH
00958 M00S00910.1lc +++| STD DP+4 RESET *OUT* POINTER TO FWA CONTROLWARE
00959 M00S00911.1lc +++| SHN -14
00960 M00S00912.1lc +++| STD DP+3
00961 M00S00913.1lc +++| LDD CN+4 LENGTH OF CONTROLWARE
00962 M00S00914.1lc +++| SBN 1 ADJUST FOR 52 TABLE
00963 M00S00915.1lc +++| STD WC CM WORD COUNT OF CONTROLWARE
00964 M00S00916.1lc +++| LDD DP+1 CHECK *IN* - *OUT*
00965 M00S00917.1lc +++| SBD DP+3
00966 M00S00918.1lc +++| SHN 14
00967 M00S00919.1lc +++| ADD DP+2
00968 M00S00920.1lc +++| SBD DP+4
00969 M00S00921.1lc +++| SBD WC
00970 M00S00922.1lc +++| ZJN PRS8 IF CORRECT CONTROLWARE LENGTH
00971 M00S00923.1lc +++| LDN RC17 * LENGTH IN 52 TABLE .NE. FET.*
00972 M00S00924.1lc +++| UJN PRS6 RETURN
00973 M00S00925.1lc +++|
Line S00926 Modification History
M01
(Removed by) 1lc7
Seq # *Modification Id* Act
----------------------------+
00974 M01S00926.1lc7 ---| PRS8 RJM GLA GET LOAD FET ADDRESS
Line S00006 Modification History
M01
(Added by) 1lc7
Seq # *Modification Id* Act
----------------------------+
00975 M01S00006.1lc7 +++| PRS8 STD CO INITIALIZE CONTROL MODULE INDICATOR
00976 M01S00007.1lc7 +++| RJM GLA GET LOAD FET ADDRESS
00977 M00S00927.1lc +++| ADN 10 READ FET+8
00978 M00S00928.1lc +++| CRD CM
00979 M00S00929.1lc +++| LDD CM+4 SET CALL STATUS
00980 M00S00930.1lc +++| SHN 0-12
00981 M00S00931.1lc +++| LPN 1
00982 M00S00932.1lc +++| STD CS
00983 M00S00933.1lc +++| ZJN PRS9 IF DRIVER CALL
00984 M00S00934.1lc +++| LDN SSTL
00985 M00S00935.1lc +++| CRD T0
00986 M00S00936.1lc +++| LDD T0+3
00987 M00S00937.1lc +++| LPN 4
00988 M00S00938.1lc +++| ZJN PRS9 IF ENGINEERING MODE ENABLED
00989 M00S00939.1lc +++| LDD CP
00990 M00S00940.1lc +++| ADN JCIW
Line S00941 Modification History
M01
(Removed by) 242l642
Seq # *Modification Id* Act
----------------------------+
00991 M01S00941.242l642 ---| CRD T0 CHECK FOR *MAS* SUBSYSTEM
Line S00001 Modification History
M01
(Added by) 242l642
Seq # *Modification Id* Act
----------------------------+
00992 M01S00001.242l642 +++| CRD T0 CHECK FOR *MSE* SUBSYSTEM
00993 M00S00942.1lc +++| LDD T0+2 GET SUBSYSTEM ID
00994 M00S00943.1lc +++| LMC ASSI
Line S00944 Modification History
M01
(Removed by) 242l642
Seq # *Modification Id* Act
----------------------------+
00995 M01S00944.242l642 ---| ZJN PRS9 IF CALLER IS *MAS* SUBSYSTEM
Line S00002 Modification History
M01
(Added by) 242l642
Seq # *Modification Id* Act
----------------------------+
00996 M01S00002.242l642 +++| ZJN PRS9 IF CALLER IS *MSE* SUBSYSTEM
00997 M00S00945.1lc +++| LDN RC11 * SYSTEM NOT IN ENGR MODE.*
00998 M00S00946.1lc +++| UJN PRS10 RETURN
00999 M00S00947.1lc +++|
01000 M00S00948.1lc +++| PRS9 LDD CM+4
01001 M00S00949.1lc +++| SHN 21-13
01002 M00S00950.1lc +++| PJN PRS11 IF CHANNEL SPECIFIED
01003 M00S00951.1lc +++| SHN 13-21
01004 M00S00952.1lc +++| LPC 777
01005 M00S00953.1lc +++| STD CO SET CONTROL MODULE EST ORDINAL
01006 M00S00954.1lc +++| RJM SCC SET CONTROL MODULE CHANNEL
01007 M00S00955.1lc +++| ZJN PRS12 IF NO ERROR
01008 M00S00956.1lc +++| PRS10 LJM PRSX RETURN
01009 M00S00957.1lc +++|
01010 M00S00958.1lc +++| PRS11 SHN 13-21
01011 M00S00959.1lc +++| RJM RCT READ CHANNEL TABLE
01012 M00S00960.1lc +++| ADN 2*CTALL READ CHANNEL CONTROLWARE TABLE
01013 M00S00961.1lc +++| CRD CM
01014 M00S00962.1lc +++| STD CE+1 SAVE CONTROLWARE ENTRY ADDRESS
01015 M00S00963.1lc +++| SHN -14
01016 M00S00964.1lc +++| STD CE
01017 M00S00965.1lc +++| LDI T6
01018 M00S00966.1lc +++| STD CT SAVE CHANNEL CONTROLWARE ENTRY
01019 M00S00967.1lc +++| LDM PRSA-CM,T6 SET *UTEM* PARAMETERS FOR CHANNEL TABLE
01020 M00S00968.1lc +++| STM CHTI+1
01021 M00S00969.1lc +++| STM CHTI+1*5+1
Line S00002 Modification History
M01
(Added by) 1lc5
M02
(Removed by) 1lc7
Seq # *Modification Id* Act
----------------------------+
01022 M02S00002.1lc7 ---| RJM RSC RESERVE AND STATUS CHANNEL
01023 M02S00003.1lc7 ---| NJN PRS10 IF ERROR RESPONSE
01024 M00S00970.1lc +++| PRS12 LDD CT
01025 M00S00971.1lc +++| SHN 0-12
01026 M00S00972.1lc +++| STM CHTI+4
01027 M00S00973.1lc +++| SHN 21-0
01028 M00S00974.1lc +++| MJN PRS13 IF LOAD ALREADY IN PROGRESS
01029 M00S00975.1lc +++| RJM ICE INTERLOCK CONTROLWARE LOAD BITS
01030 M00S00976.1lc +++| LDD CM+1
01031 M00S00977.1lc +++| ZJN PRS14 IF INTERLOCK SET CORRECTLY
01032 M00S00978.1lc +++| PRS13 RJM DCH DROP CHANNEL ASSIGNMENT
01033 M00S00979.1lc +++| LDN RC14 * CONTROLWARE LOAD ALREADY IN PROGRESS.*
01034 M00S00980.1lc +++| LJM PRSX RETURN
01035 M00S00981.1lc +++|
01036 M00S00982.1lc +++| PRS14 LDD CT SET PARAMETERS TO CLEAR CHANNEL INTERLOCK
01037 M00S00983.1lc +++| SHN -6
Line S00984 Modification History
M01
(Removed by) 1lc2
Seq # *Modification Id* Act
----------------------------+
01038 M01S00984.1lc2 ---| LPN 7
Line S00002 Modification History
M01
(Added by) 1lc2
Seq # *Modification Id* Act
----------------------------+
01039 M01S00002.1lc2 +++| LPN 17
01040 M00S00985.1lc +++| STM CHTI+4
Line S00986 Modification History
M01
(Removed by) 1lc2
Seq # *Modification Id* Act
----------------------------+
01041 M01S00986.1lc2 ---| LDC 4003
Line S00003 Modification History
M01
(Added by) 1lc2
Seq # *Modification Id* Act
----------------------------+
01042 M01S00003.1lc2 +++| LDC 4004
01043 M00S00987.1lc +++| STM CHTI
01044 M00S00988.1lc +++| LDN 5
01045 M00S00989.1lc +++| STM CHTI+1*5
01046 M00S00990.1lc +++| LDC -400
01047 M00S00991.1lc +++| RAM CHTI+1
01048 M00S00992.1lc +++| STM CHTI+1*5+1
Line S00993 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01049 M01S00993.1lc5 ---| LDC CTCH INITIALIZE CHANNEL TABLE ADDRESS
01050 M01S00994.1lc5 ---| STD T1
Line S00014 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01051 M02S00014.1lc5 ---| LDD BC CLEAR POSSIBLE CCH FLAG
01052 M02S00015.1lc5 ---| LPN 37
01053 M02S00016.1lc5 ---| STD T3
Line S00995 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01054 M01S00995.1lc5 ---| PRS15 LDI T1
01055 M01S00996.1lc5 ---| ZJN PRS16 IF END OF CHANNEL INSTRUCTIONS
01056 M01S00997.1lc5 ---| STD T2
01057 M01S00998.1lc5 ---| LDI T2 GET NEXT CHANNEL INSTRUCTION
01058 M01S00999.1lc5 ---| SCN 37
Line S01000 Modification History
M01
(Removed by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01059 M02S01000.1lc5 ---| LMD BC
Line S00017 Modification History
M01
(Added by) 252l678
M02
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01060 M02S00017.1lc5 ---| LMD T3
Line S01001 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01061 M01S01001.1lc5 ---| STI T2 INITIALIZE CHANNEL INSTRUCTION
01062 M01S01002.1lc5 ---| AOD T1
01063 M01S01003.1lc5 ---| UJN PRS15 LOOP TO CHECK FOR NEXT INSTRUCTION
01064 M01S01004.1lc5 ---|
01065 M01S01005.1lc5 ---| PRS16 LDD CT CHECK CONTROLWARE TYPE
Line S00004 Modification History
M01
(Added by) 1lc5
M02
(Removed by) 1lc7
Seq # *Modification Id* Act
----------------------------+
01066 M02S00004.1lc7 ---| LDD CT CHECK CONTROLWARE TYPE
Line S00008 Modification History
M01
(Added by) 1lc7
Seq # *Modification Id* Act
----------------------------+
01067 M01S00008.1lc7 +++| LDD CO
01068 M01S00009.1lc7 +++| NJN PRS15 IF CONTROL MODULE RELOAD
01069 M01S00010.1lc7 +++| RJM RSC RESERVE AND STATUS CHANNEL
01070 M01S00011.1lc7 +++| NJN PRS17 IF ERROR
01071 M01S00012.1lc7 +++| PRS15 LDD CT CHECK CONTROLWARE TYPE
01072 M00S01006.1lc +++| LPN 37
01073 M00S01007.1lc +++| SBN FMCW
01074 M00S01008.1lc +++| ZJN PRS17 IF MA721 (SUPPORTS *FCAR* FUNCTION)
01075 M00S01009.1lc +++| SBN PHCW-FMCW
01076 M00S01010.1lc +++| ZJN PRS17 IF MA722 (SUPPORTS *FCAR* FUNCTION)
Line S00001 Modification History
M01
(Added by) ns2454
Seq # *Modification Id* Act
----------------------------+
01077 M01S00001.ns2454 +++| SBN IDCW-PHCW
01078 M01S00002.ns2454 +++| ZJN PRS17 IF MA462 (SUPPORTS *FCAR* FUNCTION)
01079 M00S01011.1lc +++| LDN PSNI
01080 M00S01012.1lc +++| STM ILFA
01081 M00S01013.1lc +++| LDN 0
01082 M00S01014.1lc +++| PRS17 LJM PRSX RETURN
01083 M00S01015.1lc +++|
01084 M00S01016.1lc +++|
01085 M00S01017.1lc +++| PRSA BSS 0 TABLE OF RELOAD FLAG BIT POSITIONS
01086 M00S01018.1lc +++| CON 58DS6
01087 M00S01019.1lc +++| CON 46DS6
01088 M00S01020.1lc +++| CON 34DS6
01089 M00S01021.1lc +++| CON 22DS6
01090 M00S01022.1lc +++| CON 10DS6
01091 M00S01023.1lc +++| SPACE 4,10
01092 M00S01024.1lc +++|* CHANNEL TABLE.
01093 M00S01025.1lc +++|
01094 M00S01026.1lc +++|
01095 M00S01027.1lc +++| CHTB CH
Line S00005 Modification History
M01
(Added by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01096 M01S00005.1lc5 +++| SCI SPACE 4,10
01097 M01S00006.1lc5 +++|** SCI - SET CHANNEL INSTRUCTIONS.
01098 M01S00007.1lc5 +++|*
01099 M01S00008.1lc5 +++|* USES T1, T2, T3.
01100 M01S00009.1lc5 +++|
01101 M01S00010.1lc5 +++|
01102 M01S00011.1lc5 +++| SCI SUBR ENTRY/EXIT
01103 M01S00012.1lc5 +++| LDC CTCH INITIALIZE CHANNEL TABLE ADDRESS
01104 M01S00013.1lc5 +++| STD T1
01105 M01S00014.1lc5 +++| LDD BC CLEAR POSSIBLE CCH FLAG
01106 M01S00015.1lc5 +++| LPN 37
01107 M01S00016.1lc5 +++| STD T3
01108 M01S00017.1lc5 +++| SCI1 LDI T1
01109 M01S00018.1lc5 +++| ZJN SCIX IF END OF CHANNEL INSTRUCTIONS
01110 M01S00019.1lc5 +++| STD T2
01111 M01S00020.1lc5 +++| LDI T2 GET NEXT CHANNEL INSTRUCTION
01112 M01S00021.1lc5 +++| SCN 37
01113 M01S00022.1lc5 +++| LMD T3
01114 M01S00023.1lc5 +++| STI T2 INITIALIZE CHANNEL INSTRUCTION
01115 M01S00024.1lc5 +++| AOD T1
01116 M01S00025.1lc5 +++| UJN SCI1 LOOP TO CHECK FOR NEXT INSTRUCTION
01117 M01S00026.1lc5 +++| RSC SPACE 4,15
01118 M01S00027.1lc5 +++|** RSC - RESERVE AND STATUS CHANNEL.
01119 M01S00028.1lc5 +++|*
01120 M01S00029.1lc5 +++|* ENTRY (BC) = CHANNEL NUMBER.
01121 M01S00030.1lc5 +++|* = *RC2* IF DOWN CHANNEL IN USE.
01122 M01S00031.1lc5 +++|* = *RC34* IF CONTROLLER RESERVED.
01123 M01S00032.1lc5 +++|* (CS) = CHANNEL SPECIFIED ON CALL STATUS.
01124 M01S00033.1lc5 +++|*
01125 M01S00034.1lc5 +++|* EXIT (A) = 0.
01126 M01S00035.1lc5 +++|* (A) = *RC24* IF CONTROLLER RESERVED THROUGH
01127 M01S00036.1lc5 +++|* ALTERNATE ACCESS OR *RC22* IF FUNCTION
01128 M01S00037.1lc5 +++|* TIMEOUT OCCURED.
01129 M01S00038.1lc5 +++|* CHANNEL RESERVED IF NOT SYSTEM REQUEST.
01130 M01S00039.1lc5 +++|*
01131 M01S00040.1lc5 +++|* USES CM - CM+4.
01132 M01S00041.1lc5 +++|*
01133 M01S00042.1lc5 +++|* CALLS CCS, FNC, RCT, SCI.
01134 M01S00043.1lc5 +++|*
01135 M01S00044.1lc5 +++|* MACROS MONITOR, RCHAN.
01136 M01S00045.1lc5 +++|
01137 M01S00046.1lc5 +++|
01138 M01S00047.1lc5 +++| RSC2 LDD BC
01139 M01S00048.1lc5 +++| RCHAN RESERVE CHANNEL
01140 M01S00049.1lc5 +++| RSC3 AOD CF SET CHANNEL RESERVED BY *1LC* FLAG
01141 M01S00050.1lc5 +++| RSC4 RJM SCI SET CHANNEL INSTRUCTIONS
01142 M01S00051.1lc5 +++| LDD BC
01143 M01S00052.1lc5 +++| LPN 40
01144 M01S00053.1lc5 +++| ZJN RSC5 IF NOT A CIO CHANNEL
01145 M01S00054.1lc5 +++| LDC 100000 MASTER CLEAR THE CHANNEL
01146 M01S00055.1lc5 +++| RJM FNC
01147 M01S00056.1lc5 +++| NJN RSCX IF ERROR OCCURRED
01148 M01S00057.1lc5 +++| RSC5 RJM CCS CHECK CONTROLLER STATUS
01149 M01S00058.1lc5 +++| NJN RSC6 IF STATUS TIMEOUT OR STATUS NOT RECEIVED
01150 M01S00059.1lc5 +++| LDD ST
01151 M01S00060.1lc5 +++| RSC6 LPC 2000
01152 M01S00061.1lc5 +++| ZJN RSCX IF CONTROLLER NOT ALREADY RESERVED
01153 M01S00062.1lc5 +++| LDN RC34 * CHXX, CONTROLLER RESERVED.*
01154 M01S00063.1lc5 +++|
01155 M01S00064.1lc5 +++| RSC SUBR ENTRY/EXIT
01156 M01S00065.1lc5 +++| LDD CS
01157 M01S00066.1lc5 +++| ZJN RSC4 IF DRIVER CALL
01158 M01S00067.1lc5 +++| LDD BC
01159 M01S00068.1lc5 +++| RJM RCT READ CHANNEL TABLE
01160 M01S00069.1lc5 +++| LDI T6
01161 M01S00070.1lc5 +++| LPN 40
01162 M01S00071.1lc5 +++| ZJP RSC2 IF CHANNEL UP
01163 M01S00072.1lc5 +++| LDN 0
01164 M01S00073.1lc5 +++| STD CM+2
01165 M01S00074.1lc5 +++| LDD BC ASSIGN DOWNED CHANNEL
01166 M01S00075.1lc5 +++| STD CM+1
01167 M01S00076.1lc5 +++| MONITOR CCHM
01168 M01S00077.1lc5 +++| LDD CM+2
01169 M01S00078.1lc5 +++| NJP RSC3 IF CHANNEL ASSIGNED
01170 M01S00079.1lc5 +++| LDN RC2 * SPECIFIED CHANNEL IS IN USE.*
01171 M01S00080.1lc5 +++| UJN RSCX RETURN
01172 M00S01028.1lc +++| SCC SPACE 4,15
01173 M00S01029.1lc +++|** SCC - SET CONTROL MODULE CHANNEL.
01174 M00S01030.1lc +++|*
01175 M00S01031.1lc +++|* ENTRY (CO) = CONTROL MODULE EST ORDINAL.
01176 M00S01032.1lc +++|* (CS) = 0 IF DRIVER CALL.
01177 M00S01033.1lc +++|*
01178 M00S01034.1lc +++|* EXIT (A) = ERROR RESPONSE (0 IF NO ERROR).
01179 M00S01035.1lc +++|* (BC) = CHANNEL NUMBER.
01180 M00S01036.1lc +++|* (CF) .NE. 0 IF CHANNEL RESERVED.
01181 M00S01037.1lc +++|* (CT) = CONTROLWARE TYPE.
01182 M00S01038.1lc +++|* (EQ) = CONTROL MODULE EQUIPMENT NUMBER.
01183 M00S01039.1lc +++|* (CE - CE+1) = ABSOLUTE ADDRESS OF *CM* EST ENTRY.
01184 M00S01040.1lc +++|*
Line S01041 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01185 M01S01041.1lc3 ---|* USES CE+1, T5, T6, T7, CM - CM+4, CN - CN+4.
Line S00001 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01186 M01S00001.1lc3 +++|* USES BC, CF, CT, EQ, T1, CE - CE+1, CM - CM+4, CN - CN+4.
01187 M00S01042.1lc +++|*
Line S00081 Modification History
M01
(Added by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01188 M01S00081.1lc5 +++|* CALLS SCI.
01189 M01S00082.1lc5 +++|*
01190 M00S01043.1lc +++|* MACROS MONITOR, RCHAN, SFA.
01191 M00S01044.1lc +++|
01192 M00S01045.1lc +++|
Line S01046 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01193 M01S01046.1lc3 ---| SCC9 LDN RC21 * NOT CONTROL MODULE EST ORDINAL.*
Line S00002 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01194 M01S00002.1lc3 +++| SCC10 LDN RC21 * NOT CONTROL MODULE EST ORDINAL.*
01195 M00S01047.1lc +++|
01196 M00S01048.1lc +++| SCC SUBR ENTRY/EXIT
01197 M00S01049.1lc +++| SFA EST,CO GET EST ENTRY
01198 M00S01050.1lc +++| ADK EQDE
01199 M00S01051.1lc +++| CRD CN
Line S00003 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01200 M01S00003.1lc3 +++| ADN EQAE-EQDE
01201 M01S00004.1lc3 +++| CRD CM
01202 M00S01052.1lc +++| STD CE+1
01203 M00S01053.1lc +++| SHN -14
01204 M00S01054.1lc +++| STD CE
01205 M00S01055.1lc +++| LDD CN+3
Line S01056 Modification History
M01
(Removed by) 252l678
Seq # *Modification Id* Act
----------------------------+
01206 M01S01056.252l678 ---| LPC 3777
01207 M00S01057.1lc +++| LMC 2RCM
Line S01058 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01208 M01S01058.1lc3 ---| NJN SCC9 IF NOT *CM*
Line S00005 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01209 M01S00005.1lc3 +++| NJN SCC10 IF NOT CONTROL MODULE
01210 M00S01059.1lc +++| LDD CN+4 SAVE CONTROL MODULE EQUIPMENT NUMBER
01211 M00S01060.1lc +++| SHN -11
01212 M00S01061.1lc +++| STD EQ
Line S01062 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01213 M01S01062.1lc3 ---| LDD CN+2 SAVE CONTROLWARE TYPE
Line S00006 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01214 M01S00006.1lc3 +++| LDD CM+2
01215 M00S01063.1lc +++| STD CT
Line S01064 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01216 M01S01064.1lc3 ---| SHN 21-11
01217 M01S01065.1lc3 ---| MJN SCC1 IF CHANNEL ACCESS BIT SET (USE CHANNEL 1)
01218 M01S01066.1lc3 ---| LDN 14 SET SHIFT TO CHANNEL 2
Line S00007 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01219 M01S00007.1lc3 +++| SHN 0-11
01220 M01S00008.1lc3 +++| LPN 1
01221 M01S00009.1lc3 +++| LMN 1
01222 M00S01067.1lc +++| RAM SCCA
Line S01068 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01223 M01S01068.1lc3 ---| SCC1 LDD CS
Line S00010 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01224 M01S00010.1lc3 +++| LDD CS
01225 M00S01069.1lc +++| NJN SCC6 IF NOT DRIVER CALL
01226 M00S01070.1lc +++| LDD CN+1 SET CHANNEL NUMBER
Line S01071 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01227 M01S01071.1lc3 ---| SCCA SHN 0
Line S00011 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01228 M01S00011.1lc3 +++|* LDD CN+2 (CHANNEL ACCESS BIT CLEAR)
01229 M01S00012.1lc3 +++| SCCA EQU *-1
01230 M00S01072.1lc +++| LPN 37
01231 M00S01073.1lc +++| SCC2 STD BC
01232 M00S01074.1lc +++| LDN 0
01233 M00S01075.1lc +++| SCC3 LJM SCCX RETURN
01234 M00S01076.1lc +++|
Line S01077 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01235 M01S01077.1lc3 ---| SCC4 SHN 5-21
Line S00013 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01236 M01S00013.1lc3 +++| SCC4 LDI T1
01237 M00S01078.1lc +++| RCHAN RESERVE CHANNEL
Line S01079 Modification History
M01
(Removed by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01238 M01S01079.1lc5 ---| SCC5 AOD CF SET CHANNEL RESERVED BY *1LC* FLAG
Line S00083 Modification History
M01
(Added by) 1lc5
Seq # *Modification Id* Act
----------------------------+
01239 M01S00083.1lc5 +++| SCC5 RJM SCI SET CHANNEL INSTRUCTIONS
01240 M01S00084.1lc5 +++| AOD CF SET CHANNEL RESERVED BY *1LC* FLAG
01241 M00S01080.1lc +++| LDD CM+1
01242 M00S01081.1lc +++| UJN SCC2 SET CHANNEL NUMBER
01243 M00S01082.1lc +++|
Line S01083 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01244 M01S01083.1lc3 ---| SCC6 LDD CN+1
01245 M01S01084.1lc3 ---| SCC7 SHN 21-5
01246 M01S01085.1lc3 ---| PJN SCC4 IF CHANNEL NOT DOWN
01247 M01S01086.1lc3 ---| LPN 77
01248 M01S01087.1lc3 ---| NJN SCC7 IF ANOTHER CHANNEL EXISTS
01249 M01S01088.1lc3 ---| STD CM+2
01250 M01S01089.1lc3 ---| LDD CN+1
01251 M01S01090.1lc3 ---| SCC8 SHN 14
01252 M01S01091.1lc3 ---| STD CN+1
01253 M01S01092.1lc3 ---| SHN -14
01254 M01S01093.1lc3 ---| LPN 37 SET DOWNED CHANNEL NUMBER
01255 M01S01094.1lc3 ---| STD CM+1
Line S00014 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01256 M01S00014.1lc3 +++| SCC6 LDN CN+1
01257 M01S00015.1lc3 +++| STD T1
01258 M01S00016.1lc3 +++| SCC7 LDI T1
01259 M01S00017.1lc3 +++| SHN 0-12
01260 M01S00018.1lc3 +++| LMN 2
01261 M01S00019.1lc3 +++| ZJN SCC4 IF CHANNEL ENABLED AND UP
01262 M01S00020.1lc3 +++| AOD T1
01263 M01S00021.1lc3 +++| LMN CN+3
01264 M01S00022.1lc3 +++| NJN SCC7 IF ANOTHER CHANNEL BYTE TO CHECK
01265 M01S00023.1lc3 +++| SCC8 SOD T1
01266 M01S00024.1lc3 +++| LMN CN
01267 M01S00025.1lc3 +++| NJN SCC9 IF ANOTHER CHANNEL TO CHECK
01268 M01S00026.1lc3 +++| LDN RC2 * SPECIFIED CHANNEL IS IN USE.*
01269 M01S00027.1lc3 +++| UJN SCC3 RETURN
01270 M01S00028.1lc3 +++|
01271 M01S00029.1lc3 +++| SCC9 LDI T1
01272 M01S00030.1lc3 +++| STD CM+1
01273 M01S00031.1lc3 +++| SHN 21-13
01274 M01S00032.1lc3 +++| PJN SCC8 IF CHANNEL NOT ENABLED
01275 M00S01095.1lc +++| MONITOR CCHM ASSIGN DOWNED CHANNEL
01276 M00S01096.1lc +++| LDD CM+2
Line S01097 Modification History
M01
(Removed by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01277 M01S01097.1lc3 ---| NJN SCC5 IF CHANNEL ASSIGNED
01278 M01S01098.1lc3 ---| LDD CN+1
01279 M01S01099.1lc3 ---| NJN SCC8 IF ANOTHER CHANNEL
01280 M01S01100.1lc3 ---| LDN RC2 * SPECIFIED CHANNEL IS IN USE.*
01281 M01S01101.1lc3 ---| UJN SCC3 RETURN
Line S00033 Modification History
M01
(Added by) 1lc3
Seq # *Modification Id* Act
----------------------------+
01282 M01S00033.1lc3 +++| ZJN SCC8 IF CHANNEL NOT ASSIGNED
01283 M01S00034.1lc3 +++| UJP SCC5 SET CHANNEL ASSIGNED AND RETURN
01284 M00S01102.1lc +++| VFP SPACE 4,20
01285 M00S01103.1lc +++|** VFP - VALIDATE FET PARAMETERS.
01286 M00S01104.1lc +++|*
01287 M00S01105.1lc +++|* ENTRY (A) = FET ADDRESS.
01288 M00S01106.1lc +++|*
01289 M00S01107.1lc +++|* EXIT (A) = 0 IF FET ADDRESS AND BUFFER PARAMETERS VALID.
01290 M00S01108.1lc +++|* (A) = *DR1* IF BUFFER PARAMETERS INVALID.
01291 M00S01109.1lc +++|* (MB+2) = 12/0, 24/*IN*, 24/*OUT*.
01292 M00S01110.1lc +++|* (MB+3) = 1/RANDOM FILE FLAG, 5/0, 6/FET LENGTH,
01293 M00S01111.1lc +++|* 24/*FIRST*, 24/*LIMIT*.
01294 M00S01112.1lc +++|*
01295 M00S01113.1lc +++|* ERROR TO *PPR* AFTER JOB ABORT IF FET ADDRESS INVALID.
01296 M00S01114.1lc +++|*
01297 M00S01115.1lc +++|* USES CM+1, CM+3, CM+4.
01298 M00S01116.1lc +++|*
01299 M00S01117.1lc +++|* CALLS DFM.
01300 M00S01118.1lc +++|*
01301 M00S01119.1lc +++|* MACROS MONITOR.
01302 M00S01120.1lc +++|
01303 M00S01121.1lc +++|
01304 M00S01122.1lc +++| VFP1 LDN DR1 * DUMP BUFFER ARGUMENT ERROR.*
01305 M00S01123.1lc +++|
01306 M00S01124.1lc +++| VFP SUBR ENTRY/EXIT
Line S01125 Modification History
M01
(Removed by) 271l716
Seq # *Modification Id* Act
----------------------------+
01307 M01S01125.271l716 ---| STD CM+2
Line S00001 Modification History
M01
(Added by) 271l716
Seq # *Modification Id* Act
----------------------------+
01308 M01S00001.271l716 +++| STD CM+4
01309 M00S01126.1lc +++| SHN -14
Line S01127 Modification History
M01
(Removed by) 271l716
Seq # *Modification Id* Act
----------------------------+
01310 M01S01127.271l716 ---| STD CM+1
Line S00002 Modification History
M01
(Added by) 271l716
Seq # *Modification Id* Act
----------------------------+
01311 M01S00002.271l716 +++| STD CM+3
01312 M00S01128.1lc +++| LDN 3 VALIDATE *FIRST*, *IN*, *OUT*, AND *LIMIT*
Line S01129 Modification History
M01
(Removed by) 271l716
Seq # *Modification Id* Act
----------------------------+
01313 M01S01129.271l716 ---| STD CM+4
Line S00003 Modification History
M01
(Added by) 271l716
Seq # *Modification Id* Act
----------------------------+
01314 M01S00003.271l716 +++| STD CM+1
01315 M00S01130.1lc +++| MONITOR VFPM
01316 M00S01131.1lc +++| LDD CM+1
01317 M00S01132.1lc +++| ZJN VFPX IF FET ADDRESS AND BUFFER PATAMETERS VALID
01318 M00S01133.1lc +++| SBN 1
01319 M00S01134.1lc +++| NJN VFP1 IF NOT INVALID FET ADDRESS
01320 M00S01135.1lc +++| LDC VFPA * FET ADDRESS OUT OF RANGE.*
01321 M00S01136.1lc +++| RJM DFM
01322 M00S01137.1lc +++| MONITOR ABTM ABORT CONTROL POINT
01323 M00S01138.1lc +++| LJM PPR EXIT TO PP RESIDENT
01324 M00S01139.1lc +++|
01325 M00S01140.1lc +++|
01326 M00S01141.1lc +++| VFPA DATA C* FET ADDRESS OUT OF RANGE.*
01327 M00S01142.1lc +++| SPACE 4,10
01328 M00S01143.1lc +++| END