Seq # *Modification Id* Act
----------------------------+
02077 M01S00058.ns2748 +++| PIR$ EQU 1 SELECT ASSEMBLY OF *PIR* FOR IAF R-REG
02078 M01S00059.ns2748 +++|*CALL,COMPSRR
02079 M00S02011.1mi +++|*CALL,COMPCRS
02080 M00S02012.1mi +++|*CALL,COMPRBB
02081 M00S02013.1mi +++|*CALL,COMPSPA
02082 M00S02014.1mi +++|*CALL,COMPSTA
02083 M00S02015.1mi +++|*CALL,COMPUPP
02084 M00S02016.1mi +++|*CALL,COMPWBB
02085 M00S02017.1mi +++| HST TITLE FUNCTION REQUEST AND BUFFER STORAGE.
02086 M00S02018.1mi +++|** PREVIOUS PP RECALL PARAMETER WORD.
02087 M00S02019.1mi +++|* IF *1MI* IS STARTED FROM THE RECALL STACK, THIS WORD WILL
02088 M00S02020.1mi +++|* CONTAIN INFORMATION SAVED BY THE PREVIOUS COPY OF *1MI*
02089 M00S02021.1mi +++|* IN THE FOLLOWING FORMAT -
02090 M00S02022.1mi +++|*
02091 M00S02023.1mi +++|* 1/S, 5/, 6/CP, 6/RC, 18/, 12/FP, 1/A, 1/, 4/IF, 3/, 3/RT
02092 M00S02024.1mi +++|*
02093 M00S02025.1mi +++|* S SET BY *CPUMTR* TO SHOW *1MI* STARTED FROM RECALL.
02094 M00S02026.1mi +++|* CP UNUSED (WARNING - SOMETIMES SET BY *CPUMTR*).
02095 M00S02027.1mi +++|* RC REASON CODE WHY *1MI* ENTERED RECALL.
02096 M00S02028.1mi +++|* FP FIRST POT IN CHAIN PRIOR TO RECALL.
02097 M00S02029.1mi +++|* A SET IF MONITOR FUNCTION REJECTED BECAUSE IAF ABORTED.
02098 M00S02030.1mi +++|* IF *CIO* INTERNAL FUNCTION CODE (SEE *COMSCIO*).
02099 M00S02031.1mi +++|* RT MONITOR FUNCTION REJECTION COUNT.
02100 M00S02032.1mi +++|
02101 M00S02033.1mi +++|
02102 M00S02034.1mi +++| RCRF CON 0,0,0,0,0
02103 M00S02035.1mi +++|
02104 M00S02036.1mi +++|
02105 M00S02037.1mi +++|
02106 M00S02038.1mi +++|** NEW PP RECALL PARAMETER WORD.
02107 M00S02039.1mi +++|* USED IF *1MI* MUST ENTER RECALL. IT HAS THE SAME FORMAT AS
02108 M00S02040.1mi +++|* THE PREVIOUS PP RECALL PARAMETER WORD.
02109 M00S02041.1mi +++|
02110 M00S02042.1mi +++|
02111 M00S02043.1mi +++| RCPW CON 0,0,0,0,0
02112 M00S02044.1mi +++| HST SPACE 4,10
02113 M00S02045.1mi +++|** TIAF - TABLE OF *TSEM* FUNCTION REQUEST DEFINITIONS.
02114 M00S02046.1mi +++|*
02115 M00S02047.1mi +++|* ENTRY FIVE WORDS. CONTENTS VARY PER *TSEM* REQUEST.
02116 M00S02048.1mi +++|*
02117 M00S02049.1mi +++|* WADO - ASSIGN DIRECT OUTPUT TO IAF.
02118 M00S02050.1mi +++|*
02119 M00S02051.1mi +++|*T 12//REM/VADO, 6/0, 6/PC, 12/LP, 12/FP, 12/TN
02128 M00S02060.1mi +++|*
02129 M00S02061.1mi +++|* PC = POT MEMORY CHAIN COUNT PER CURRENT REQUEST.
02130 M00S02062.1mi +++|* FP = FIRST POT MEMORY POINTER PER CURRENT REQUEST.
02131 M00S02063.1mi +++|* LP = LAST POT MEMORY POINTER PER CURRENT REQUEST.
02132 M00S02064.1mi +++|* TN = TERMINAL CONNECTION NUMBER.
02133 M00S02065.1mi +++|
02134 M00S02066.1mi +++|
02135 M00S02067.1mi +++| TIAF BSS 0
02136 M00S02068.1mi +++|
02137 M00S02069.1mi +++| WADO BSS 0 ASSIGN DIRECT OUTPUT
02138 M00S02070.1mi +++| WADI BSS 0 ASSIGN DIRECT INPUT
02139 M00S02071.1mi +++| WDPO BSS 0 DROP POT MEMORY REQUEST
02140 M00S02072.1mi +++| WIAF CON 0,0,0,0,0 *TSEM* FUNCTION REQUEST PARMAETERS
02141 M00S02073.1mi +++|
02142 M00S02074.1mi +++|
02143 M00S02075.1mi +++|
02144 M00S02076.1mi +++|
02145 M00S02077.1mi +++|* DATA TRANSFER BUFFER OVERLAYS PRESET.
02146 M00S02078.1mi +++|
02147 M00S02079.1mi +++|
02148 M00S02080.1mi +++| USE BUFFERS
02149 M00S02081.1mi +++|
02150 M00S02082.1mi +++|
02151 M00S02083.1mi +++|
02152 M00S02084.1mi +++| BUFF EQU *
02153 M00S02085.1mi +++|
02154 M00S02086.1mi +++| BUFFL EQU /REM/VCPC*2*5
02155 M00S02087.1mi +++| ERRNG 100000-BUFF-BUFFL
02156 M00S02088.1mi +++|
02157 M00S02089.1mi +++|
02158 M00S02090.1mi +++|
02159 M00S02091.1mi +++|
02160 M00S02092.1mi +++|
02161 M00S02093.1mi +++| PRS TITLE *1MI* INITIALIZATION.
02162 M00S02094.1mi +++|** PRS - PRESET *1MI*.
02163 M00S02095.1mi +++|*
02164 M00S02096.1mi +++|* ENTRY (IR - IR+4) = *1MI* CALL.
02165 M00S02097.1mi +++|* (MB - MB+4) = *1MI* MESSAGE BUFFER PARAMETERS (*PPR*)
02166 M00S02098.1mi +++|* (MB1 - MB1+4) = MESSAGE BUFFER + 1 PARAMETERS.
02167 M00S02099.1mi +++|* (MB2 - MB2+4) = MESSAGE BUFFER + 2 PARAMETERS.
02168 M00S02100.1mi +++|*
02169 M00S02101.1mi +++|* EXIT (FC) = INTERNAL *CIO* FUNCTION CODE.
02170 M00S02102.1mi +++|* (BS - BS+4) = BUFFER STATUS = (FET+0)
02171 M00S02103.1mi +++|* (FT - FT+1) = BUFFER FIRST WORD ADDRESS.
02172 M00S02104.1mi +++|* (IN - IN+1) = BUFFER IN POINTER.
02173 M00S02105.1mi +++|* (OT - OT+1) = BUFFER OUT POINTER.
02174 M00S02106.1mi +++|* (LM - LM+1) = BUFFER LAST WORD ADDRESS.
02175 M00S02107.1mi +++|* (TT - TT+1) = TERMINAL TABLE ADDRESS.
02176 M00S02108.1mi +++|* (RCRF - RCRF+4) = PARAMETER WORD FROM PREVIOUS IAF.
02177 M00S02109.1mi +++|* TO *DPP* IF USER BREAK PROCESS WITH EXTENDED REPRIEVE.
02178 M00S02110.1mi +++|* TO *ERS* IF IAF INACCESSIBLE TO ALLOW USER RECOVERY.
02179 M00S02111.1mi +++|*
02180 M00S02112.1mi +++|* USES CM - CM+4, CN - CN+4, FT-1 - FT+3, IN-1 - IN+3,
02181 M00S02113.1mi +++|* BS - BS+4, FC, NF, TN, T0.
02182 M00S02114.1mi +++|*
02183 M00S02115.1mi +++|* CALLS CFN, CJA, CTT, ITA, REC, ROJ, STA.
02184 M00S02116.1mi +++|*
02185 M00S02117.1mi +++|* MACROS CFET, ERROR, SFA.
02186 M00S02118.1mi +++|
02187 M00S02119.1mi +++|
02188 M00S02120.1mi +++| PRS SUBR ENTRY/EXIT
02189 M00S02121.1mi +++|
02190 M00S02122.1mi +++|* MOVE PP RECALL PARAMETER WORDS TO LOCATIONS WHICH ARE NOT
02191 M00S02123.1mi +++|* DESTROYED BY COMMON DECKS.
02192 M00S02124.1mi +++|
02193 M00S02125.1mi +++| LDD MA RESET FET PARAMETERS IN MESSAGE BUFFER
02194 M00S02126.1mi +++| CWD MB
02195 M00S02127.1mi +++| ADN 1 PRESET BUFFER POINTERS
02196 M00S02128.1mi +++| CWD MB1
02197 M00S02129.1mi +++| CRD IN-1 *IN* AND *OUT*
02198 M00S02130.1mi +++| ADN 1
02199 M00S02131.1mi +++| CWD MB2
02200 M00S02132.1mi +++| CRD FT-1 *FIRST* AND *LIMIT*
02201 M00S02133.1mi +++| LDD MB+4 INTERNAL *CIO* FUNCTION CODE
02202 M00S02134.1mi +++| LPC 1700
02203 M00S02135.1mi +++| STM RCPW+4 SAVE IN CASE *1MI* GOES INTO RECALL
02204 M00S02136.1mi +++| SHN -6
02205 M00S02137.1mi +++| STD FC
02206 M00S02138.1mi +++| CFET READ FET+0
02207 M00S02139.1mi +++| CRD BS
02208 M00S02140.1mi +++| LDD MB
02209 M00S02141.1mi +++| SHN 21-13
02210 M00S02142.1mi +++| PJN PRS1 IF INITIAL *1MI* CALL
02211 M00S02143.1mi +++| LDD MA
02212 M00S02144.1mi +++| CRM RCRF,ON READ IN PREVIOUS RECALL PARAMETER WORD
02213 M00S02145.1mi +++| RJM REC RECOVER *TSEM* REJECT
02214 M00S02146.1mi +++| PRS1 RJM CTT CHECK TERMINAL I/O INTERLOCK
02215 M00S02147.1mi +++| LDD CP
02216 M00S02148.1mi +++| ADK TFSW
02217 M00S02149.1mi +++| CRD CM
02218 M00S02150.1mi +++| LDD CM
02219 M00S02151.1mi +++| ZJN PRS2 IF NO EJT ORDINAL
02220 M00S02152.1mi +++| SFA EJT
02221 M00S02153.1mi +++| ADK JSNE CHECK JOB CONNECTION STATUS
02222 M00S02154.1mi +++| CRD CM
02223 M00S02155.1mi +++| LDD CM+4
02224 M00S02156.1mi +++| SHN -7
02225 M00S02157.1mi +++| LPN 17
02226 M00S02158.1mi +++| STM PRSA
02227 M00S02159.1mi +++| LMK NICS
02228 M00S02160.1mi +++| ZJN PRS2 IF NON-INTERACTIVE
02229 M00S02161.1mi +++| RJM CEF
02230 M00S02162.1mi +++| ZJN PRS6 IF NO ERROR FLAG ON JOB
02231 M00S02163.1mi +++| LDD FC *1MI* FUNCTION CODE
02232 M00S02164.1mi +++| LMK /CIO/WTF
Line S02165 Modification History
M01(Removed by)
1mi5
Seq # *Modification Id* Act
----------------------------+
02233 M01S02165.1mi5 ---| ZJN PRS2 IF ERROR FLAG ON WRITE FUNCTION
Line S00001 Modification History
M01(Added by)
1mi5
Seq # *Modification Id* Act
----------------------------+
02234 M01S00001.1mi5 +++| ZJN PRS6 IF A WRITE FUNCTION
02235 M00S02166.1mi +++| LDD CM+2
02236 M00S02167.1mi +++| NJN PRS3 IF USER BREAK AND EXTENDED REPRIEVE
02237 M00S02168.1mi +++| LDD BS+4 SET EOR STATUS
02238 M00S02169.1mi +++| LPC 6002
02239 M00S02170.1mi +++| LMN 20
02240 M00S02171.1mi +++| STD BS+4
02241 M00S02172.1mi +++| PRS2 RJM CFN COMPLETE FUNCTION
02242 M00S02173.1mi +++| PRS3 LJM DPP DROP PP
02243 M00S02174.1mi +++|
02244 M00S02175.1mi +++| PRS6 RJM ITA
02245 M00S02176.1mi +++| ZJN PRS7 IF IAF NOT AVAILABLE
02246 M00S02177.1mi +++| LDC 0 CHECK CONNECTION STATUS
02247 M00S02178.1mi +++| PRSA EQU *-1
02248 M00S02179.1mi +++| LMK DTCS
02249 M00S02180.1mi +++| NJN PRS9 IF NOT DETACHED
02250 M00S02181.1mi +++|
02251 M00S02182.1mi +++|* A DETACHED JOB IS EITHER SUSPENDED OR TERMINATED BASED ON ITS
02252 M00S02183.1mi +++|* END-OF-JOB OPTIONS.
02253 M00S02184.1mi +++|
02254 M00S02185.1mi +++| LDD CP CHECK END-OF-JOB TERMINATION OPTIONS
02255 M00S02186.1mi +++| ADN EOJW
02256 M00S02187.1mi +++| CRD CM
02257 M00S02188.1mi +++| LDD CM
02258 M00S02189.1mi +++| SHN 0-11 ISOLATE JOB TERMINATION OPTION
02259 M00S02190.1mi +++| LMN SUJT
02260 M00S02191.1mi +++| ZJN PRS7 IF DETACHED JOB IS TO BE SUSPENDED
02261 M00S02192.1mi +++| ERROR IRQ *INCORRECT I/O REQUEST ON FILE*
02262 M00S02193.1mi +++|
02263 M00S02194.1mi +++| PRS7 LDK IAFF
02264 M00S02195.1mi +++| RAM RCPW+4
02265 M00S02196.1mi +++| LDK ROSU SUSPEND USER JOB
02266 M00S02197.1mi +++| PRS8 STD T0
02267 M00S02198.1mi +++| RJM ROJ ROLL USER JOB
02268 M00S02199.1mi +++| LDK TALR TERMINAL I/O BUSY RECALL CODE
02269 M00S02200.1mi +++| LJM ERS ENTER RECALL STACK
02270 M00S02201.1mi +++|
02271 M00S02202.1mi +++|* CONTINUE PROCESS FOR ONLINE CONNECTIONS ONLY.
02272 M00S02203.1mi +++|
02273 M00S02204.1mi +++| PRS9 LDD CP
02274 M00S02205.1mi +++| ADN TTNW TERMINAL TABLE POINTER
02275 M00S02206.1mi +++| CRD CM
02276 M00S02207.1mi +++| LDD CM+1
02277 M00S02208.1mi +++| STD TN
Line S00060 Modification History
M01(Added by)
ns2748
Seq # *Modification Id* Act
----------------------------+
02278 M01S00060.ns2748 +++| RJM SRR SET R-REGISTER TO IAF RA
02279 M00S02209.1mi +++| RJM STA SET TERMINAL TABLE ADDRESS (TT - TT+1)
02280 M00S02210.1mi +++|
02281 M00S02211.1mi +++|* ROLL A USER OUT DURING LOGIN PROCESSING AND DURING DETACH
02282 M00S02212.1mi +++|* PROCESSING IF THE TERMINAL TABLE IS NOT COMPLETELY SET UP.
02283 M00S02213.1mi +++|* THIS AVOIDS *VADO* AND *VADI* *TSEM* REQUESTS BEING SENT TO
02284 M00S02214.1mi +++|* *IAF* BEFORE THE USER IS COMPLETELY LOGGED IN.
02285 M00S02215.1mi +++|
02286 M00S02216.1mi +++| ADK /REM/VDCT CHECK IF USER FINISHED LOGGING IN
02287 M00S02217.1mi +++| CRD CM
02288 M00S02218.1mi +++| ADK /REM/VSTT-/REM/VDCT
02289 M00S02219.1mi +++| CRD CN READ *VSTT*
Line S00061 Modification History
M01(Added by)
ns2748
Seq # *Modification Id* Act
----------------------------+
02290 M01S00061.ns2748 +++| RJM RRR RESTORE R-REGISTER
02291 M00S02220.1mi +++| LDD CM
02292 M00S02221.1mi +++| SHN 21-11
02293 M00S02222.1mi +++| PJN PRS9.1 IF USER NOT COMPLETELY LOGGED IN
02294 M00S02223.1mi +++| LDD CN CHECK FOR DETACH IN PROGRESS
02295 M00S02224.1mi +++| SHN 21-10
02296 M00S02225.1mi +++| PJN PRS10 IF DETACH NOT IN PROGRESS
02297 M00S02226.1mi +++| PRS9.1 LDK ROSR
02298 M00S02227.1mi +++| UJP PRS8 ROLLOUT USER JOB UNTIL COMPLETE RECOVERY
02299 M00S02228.1mi +++|
02300 M00S02229.1mi +++| PRS10 LDD CP GET NEGATIVE FIELD LENGTH
02301 M00S02230.1mi +++| ADN FLSW
02302 M00S02231.1mi +++| CRD CM
02303 M00S02232.1mi +++| LDD CM
02304 M00S02233.1mi +++| STD NF NFL/100B
02305 M00S02234.1mi +++| UJP PRSX RETURN
02306 M00S02235.1mi +++| CTT SPACE 4,10
02307 M00S02236.1mi +++|** CTT - CHECK TIOW/TINW BUSY.
02308 M00S02237.1mi +++|*
02309 M00S02238.1mi +++|* *CTT* CHECKS THE *TINW/TIOW* INTERLOCK FLAG FROM *CPUMTR* TO
02310 M00S02239.1mi +++|* DETERMINE WHETHER OR NOT THIS COPY OF *1MI* HAS THE TERMINAL
02311 M00S02240.1mi +++|* I/O INTERLOCK. IF NOT, *CTT* ATTEMPTS TO GET THE INTERLOCK
02312 M00S02241.1mi +++|* VIA A *UTEM* FUNCTION. IF UNSUCCESSFUL, *1MI* MUST GO INTO
02313 M00S02242.1mi +++|* RECALL AND TRY TO OBTAIN THE INTERLOCK AT A LATER TIME.
02314 M00S02243.1mi +++|*
02315 M00S02244.1mi +++|* ENTRY (IR+2) = TIOW/TINW BUSY FLAG FROM *CPUMTR*.
02316 M00S02245.1mi +++|*
02317 M00S02246.1mi +++|* EXIT IF RECALL NECESSARY, TO *ERS*.
02318 M00S02247.1mi +++|*
02319 M00S02248.1mi +++|* USES CM - CM+4, IR+2.
02320 M00S02249.1mi +++|*
02321 M00S02250.1mi +++|* MACROS MONITOR.
02322 M00S02251.1mi +++|
02323 M00S02252.1mi +++|
02324 M00S02253.1mi +++| CTT4 LDD IR+2 CLEAR FLAG FROM INPUT REGISTER
02325 M00S02254.1mi +++| LMK TTB
02326 M00S02255.1mi +++| STD IR+2
02327 M00S02256.1mi +++| LDD IA REWRITE INPUT REGISTER
02328 M00S02257.1mi +++| CWD IR
02329 M00S02258.1mi +++|
02330 M00S02259.1mi +++| CTT SUBR ENTRY/EXIT
02331 M00S02260.1mi +++| LDD IR+2 CHECK FLAG FROM *CPUMTR*
02332 M00S02261.1mi +++| LPK TTB
02333 M00S02262.1mi +++| ZJN CTTX IF TIOW/TINW GOES WITH THIS PP
02334 M00S02263.1mi +++| LDK ZERL TEST AND SET TIOW/TINW
02335 M00S02264.1mi +++| CRD CM
02336 M00S02265.1mi +++| LDD CP SET WORD ADDRESS
02337 M00S02266.1mi +++| ADK TIOW
02338 M00S02267.1mi +++| STD CM+4
02339 M00S02268.1mi +++| ERRNG TINW-TIOW CODE DEPENDS ON ORDER OF WORDS
02340 M00S02269.1mi +++| LDN 3 TEST TWO FIELDS, SET ONE
02341 M00S02270.1mi +++| STD CM+1
02342 M00S02271.1mi +++| LDD FC
02343 M00S02272.1mi +++| LMK /CIO/WTF
02344 M00S02273.1mi +++| ZJN CTT1 IF WRITE FUNCTION
02345 M00S02274.1mi +++| LDC 18D*100B SET TINW ADDRESS OFFSET AND FIELD
02346 M00S02275.1mi +++| RAM CTTB+1
02347 M00S02276.1mi +++| LDK TINW-TIOW SET TINW FIELD
02348 M00S02277.1mi +++| SHN 6
02349 M00S02278.1mi +++| RAM CTTB
02350 M00S02279.1mi +++| CTT1 LDD IR+4 MOVE FET ADDRESS
02351 M00S02280.1mi +++| STM CTTB+4
02352 M00S02281.1mi +++| LDD IR+3
02353 M00S02282.1mi +++| LPN 77
02354 M00S02283.1mi +++| STM CTTB+3
02355 M00S02284.1mi +++| LDD MA
02356 M00S02285.1mi +++| CWM CTTA,TR
02357 M00S02286.1mi +++| MONITOR UTEM
02358 M00S02287.1mi +++| LDD CM+1
02359 M00S02288.1mi +++| ZJP CTT4 IF TEST AND SET SUCCESSFUL
02360 M00S02289.1mi +++| RJM CEF
02361 M00S02290.1mi +++| LDD CM+2
02362 M00S02291.1mi +++| NJN CTT2 IF USER BREAK WITH EXTENDED REPRIEVE
02363 M00S02292.1mi +++|
02364 M00S02293.1mi +++|* ENTER RECALL WITH TIOW/TINW BUSY FLAG STILL SET IN THE INPUT
02365 M00S02294.1mi +++|* REGISTER, SO THAT WHEN *1MI* IS RESTARTED IT WILL
02366 M00S02295.1mi +++|* AGAIN ATTEMPT TO GET THE *TIOW/TINW* INTERLOCK.
02367 M00S02296.1mi +++|
02368 M00S02297.1mi +++| LDK TALR
02369 M00S02298.1mi +++| LJM ERS ENTER RECALL STACK
02370 M00S02299.1mi +++|
02371 M00S02300.1mi +++|* IF BOTH A USER BREAK ERROR FLAG IS PRESENT AND EXTENDED
02372 M00S02301.1mi +++|* REPRIEVE HAS BEEN SELECTED BY THE JOB, *1MI* CANNOT WAIT
02373 M00S02302.1mi +++|* FOR THE TERMINAL I/O INTERLOCK TO BECOME AVAILABLE. THIS IS
02374 M00S02303.1mi +++|* BECAUSE THE PP WITH THE INTERLOCK MAY BE A READ REQUEST, IN
02375 M00S02304.1mi +++|* WHICH CASE IT WILL DROP WITHOUT CLEARING *TINW*.
02376 M00S02305.1mi +++|* IF A WRITE REQUEST, *1MI* WILL COMPLETE THE FET AND DROP.
02377 M00S02306.1mi +++|* IF A READ REQUEST, *1MI* WILL ATTEMPT TO SET *TINW* BEFORE
02378 M00S02307.1mi +++|* DROPPING SO THAT *1AJ* KNOWS THAT AN INPUT REQUEST IS
02379 M00S02308.1mi +++|* OUTSTANDING.
02380 M00S02309.1mi +++|
02381 M00S02310.1mi +++| CTT2 LDD FC
02382 M00S02311.1mi +++| LMK /CIO/WTF
02383 M00S02312.1mi +++| ZJN CTT3 IF WRITE FUNCTION
02384 M00S02313.1mi +++| LDK ZERL
02385 M00S02314.1mi +++| CRD CM
02386 M00S02315.1mi +++| LDD CP
02387 M00S02316.1mi +++| ADK TIOW
02388 M00S02317.1mi +++| STD CM+4
02389 M00S02318.1mi +++| LDN 2
02390 M00S02319.1mi +++| STD CM+1
02391 M00S02320.1mi +++| LDD MA
02392 M00S02321.1mi +++| CWM CTTA+5,CM+1
02393 M00S02322.1mi +++| MONITOR UTEM
02394 M00S02323.1mi +++| LJM DPP DROP PP
02395 M00S02324.1mi +++|
02396 M00S02325.1mi +++| CTT3 LDD BS+4 COMPLETE FET
02397 M00S02326.1mi +++| SCN 1
02398 M00S02327.1mi +++| LMN 1
02399 M00S02328.1mi +++| STD BS+4
02400 M00S02329.1mi +++| CFET REWRITE FIRST WORD OF FET
02401 M00S02330.1mi +++| CWD BS
02402 M00S02331.1mi +++| LJM DPP DROP PP
02403 M00S02332.1mi +++|
02404 M00S02333.1mi +++|
02405 M00S02334.1mi +++| CTTA VFD 1/1,5/0,6/18D,6/0,42/0 VERIFY 0 CLEAR
02406 M00S02335.1mi +++| VFD 1/1,5/TINW-TIOW,6/18D,6/18D,42/0 VERIFY TINW CLEAR
02407 M00S02336.1mi +++| CTTB VFD 1/0,5/0,6/18D,6/0,42/0 SET NEW FET ADDRESS
02408 M00S02337.1mi +++| REC SPACE 4,10
02409 M00S02338.1mi +++|** REC - RECOVER FROM MONITOR REJECTION.
02410 M00S02339.1mi +++|*
02411 M00S02340.1mi +++|* ENTRY (RCRF+1) = RECALL REASON CODE.
02412 M00S02341.1mi +++|* (RCRF+3) = FIRST POT CHAIN POINTER.
02413 M00S02342.1mi +++|* (FC) = INITIAL *1MI* FUNCTION CODE.
02414 M00S02343.1mi +++|*
02415 M00S02344.1mi +++|* EXIT TO *DPP* IF *TINW/TIOW* INTERLOCK NO LONGER HELD.
02416 M00S02345.1mi +++|* ANY POTS FROM A PREVIOUSLY REJECTED MONITOR FUNCTION
02417 M00S02346.1mi +++|* ARE DROPPED.
02418 M00S02347.1mi +++|*
02419 M00S02348.1mi +++|* USES CM - CM+4, CN - CN+4.
02420 M00S02349.1mi +++|*
02421 M00S02350.1mi +++|* CALLS MRJ.
02422 M00S02351.1mi +++|*
02423 M00S02352.1mi +++|* MACROS MONITOR.
02424 M00S02353.1mi +++|
02425 M00S02354.1mi +++|
02426 M00S02355.1mi +++| REC SUBR ENTRY/EXIT
02427 M00S02356.1mi +++| LDM RCRF+1 GET REJECTED FUNCTION
02428 M00S02357.1mi +++| SHN -6
02429 M00S02358.1mi +++| LMK TDOR
02430 M00S02359.1mi +++| ZJN REC2 IF *VADO* REJECTION
02431 M00S02360.1mi +++| LMK TPOR&TDOR
02432 M00S02361.1mi +++| NJP RECX IF NOT *VDPO* REJECTION
02433 M00S02362.1mi +++| AOM RECA
02434 M00S02363.1mi +++|
02435 M00S02364.1mi +++|* DROP PREVIOUS FUNCTION-S POTS UNLESS THE FUNCTION WAS
02436 M00S02365.1mi +++|* REJECTED BECAUSE IAF WAS NOT AVAILABLE.
02437 M00S02366.1mi +++|
02438 M00S02367.1mi +++| REC2 LDM RCRF+4
02439 M00S02368.1mi +++| LPK IAFF
02440 M00S02369.1mi +++| NJN REC3 IF NEW COPY OF IAF
02441 M00S02370.1mi +++| LDK ZERL BUILD *VDPO* *TSEM* REQUEST
02442 M00S02371.1mi +++| CRD CN
02443 M00S02372.1mi +++| LDK /REM/VDPO
02444 M00S02373.1mi +++| STD CN
02445 M00S02374.1mi +++| LDM RCRF+3 SET POT NUMBER OF FIRST POT IN CHAIN
02446 M00S02375.1mi +++| STD CN+3
02447 M00S02376.1mi +++| LDD CP SET TERMINAL NUMBER
02448 M00S02377.1mi +++| ADK TTNW
02449 M00S02378.1mi +++| CRD CM
02450 M00S02379.1mi +++| LDD CM+1
02451 M00S02380.1mi +++| STD CN+4
02452 M00S02381.1mi +++| LDN ZERL
02453 M00S02382.1mi +++| CRD CM
02454 M00S02383.1mi +++| LDD MA
02455 M00S02384.1mi +++| CWD CN REWRITE REJECTED REQUEST
02456 M00S02385.1mi +++| CRM WIAF,ON PRESET POSSIBLE FUNCTION REJECTION
02457 M00S02386.1mi +++| MONITOR TSEM
02458 M00S02387.1mi +++| LDM RCRF+1
02459 M00S02388.1mi +++| SHN -6
02460 M00S02389.1mi +++| RJM MRJ
02461 M00S02390.1mi +++| REC3 LDN 0
02462 M00S02391.1mi +++|* LDN 1
02463 M00S02392.1mi +++| RECA EQU *-1
02464 M00S02393.1mi +++| ZJP RECX IF INTERLOCK STILL HELD
02465 M00S02394.1mi +++| LJM DPP DROP PP
02466 M00S02395.1mi +++|
02467 M00S02396.1mi +++|
02468 M00S02397.1mi +++|
02469 M00S02398.1mi +++|** COMMON DECKS NECESSARY FOR PRESET.
02470 M00S02399.1mi +++|
02471 M00S02400.1mi +++|*CALL,COMPGFP
02472 M00S02401.1mi +++|
02473 M00S02402.1mi +++|
02474 M00S02403.1mi +++|
02475 M00S02404.1mi +++|
02476 M00S02405.1mi +++|
02477 M00S02406.1mi +++| ERRNG 7777-*+1 AVOID PPU MEMORY WRAP
02478 M00S02407.1mi +++| END