Type ASSEMBLE
Source Lines : 172
Fixes Applied : 0
Most Recent Version : Tuesday, December 12, 1978
Last Fix ID : [Unmodified]
Module
DMSBAB * *
Function
DMSBAB GIVES CONTROL TO AN ABNORMAL * TERMINATION ROUTINE IF LINKAGE HAS BEEN * ESTABLISHED VIA A STXIT AB MACRO. * *
Attributes
DISCONTIGUOUS SHARED SEGMENT * REENTRANT * *
Operation
DMSBAB FIRST DETERMINES IF LINKAGE HAS BEEN * ESTABLISHED TO AN ABNORMAL TERMINATION ROUTINE * VIA THE STXIT AB MACRO. IF NO LINKAGE HAS BEEN * ESTABLISHED, DMSBAB ISSUES AN SVC 6 TO CANCEL * THE ROUTINE. IF LINKAGE HAS BEEN ESTABLISHED, THE AB * OPTION TABLE ENTRY IS ZEROED, THE PC OPTION * TABLE ENTRY IS ZEROED AND CONTROL IS PASSED * TO THE AB ROUTINE ESTABLISHED BY THE STXIT AB MACRO. *
Calls to Other Routines
NONE OTHER THAN THE NORMAL/ABNORMAL EXITS. * *