Date Tuesday Feb 16, 2016 04:17:00 PM
Loaded from MAINT(094)
HRC106DK: ./ R 00352000 00353000 $ 00352090 90
HRC106DK: LA R1,2(,R1) Point to 3375 cylinder limit HRC106DK
HRC106DK: LA R2,1(,R2) Point to 3375 page limit HRC106DK
HRC106DK: CLI RDEVTYPE,TYP3375 3375 ?? HRC106DK
HRC106DK: BE CHKVALID Validate page and cylinder HRC106DK
HRC106DK: CLI RDEVTYPE,TYP3380 3380 ?? HRC106DK
HRC106DK: BNE CK2314 Skip to next type HRC106DK
HRC106DK: LA R1,2(,R1) Point to 3380 K cylinder limit HRC106DK
HRC106DK: LA R2,1(,R2) Point to 3380 page limit HRC106DK
HRC106DK: TM RDEVMDL,RDEVMD83 Triple density 3380? HRC106DK
HRC106DK: BO CHKVALID Validate page and cylinder HRC106DK
HRC106DK: LA R1,2(,R1) Point to 3380 E cylinder limit HRC106DK
HRC106DK: TM RDEVMDL,RDEVMD82 Double density 3380? HRC106DK
HRC106DK: BO CHKVALID Validate page and cylinder HRC106DK
HRC106DK: LA R1,2(,R1) Point to 3380 A/D/J cyl. limit HRC106DK
HRC106DK: B CHKVALID Validate page and cylinder HRC106DK
HRC106DK: CK2314 LA R1,8(,R1) Skip 3375/3380 cylinder limits HRC106DK
HRC106DK: LA R2,2(,R2) Skip 3375/3380 page limits HRC106DK
HRC106DK: ./ I 00465000 $ 00465100 100
HRC106DK: DC H'958' Cylinder limit for a 3375 HRC106DK
HRC106DK: DC H'2654' Cylinder limit for a 3380 (K) HRC106DK
HRC106DK: DC H'1769' Cylinder limit for a 3380 (E) HRC106DK
HRC106DK: DC H'884' Cylinder limit for a 3380 (A/D/J)HRC106DK
HRC106DK: ./ I 00476000 $ 00476100 100
HRC106DK: DC AL1(96) Page limit for 3375 HRC106DK
HRC106DK: DC AL1(150) Page limit for 3380 HRC106DK
BEGIN APPLY >>> ./ R 00352000 00353000 $ 00352090 90
END APPLY >>> ./ R 00352000 00353000 $ 00352090 90
BEGIN APPLY >>> ./ I 00465000 $ 00465100 100
END APPLY >>> ./ I 00465000 $ 00465100 100
BEGIN APPLY >>> ./ I 00476000 $ 00476100 100
END APPLY >>> ./ I 00476000 $ 00476100 100
Update Succeeded
Update Execution Time 16 milliseconds.
Date Sunday Feb 25, 2018 10:19:00 AM
Loaded from MAINT(094)
HRC075DK: ./ R 00274000 00274000 $ 00274000 200
HRC075DK: ERRSTART EQU * HRC075DK
HRC075DK: L R1,=A(DMKSYSER) -> ERR area cyls info HRC075DK
HRC075DK: LH R1,4(,R1) Get CUU of ERR area HRC075DK
HRC075DK: ./ R 00325000 00325000 $ 00325000 500
HRC075DK: L R1,=A(DMKSYSER) -> ERR area cyls info HRC075DK
HRC075DK: LH R1,4(,R1) Get CUU of ERR area HRC075DK
BEGIN APPLY >>> ./ R 00274000 00274000 $ 00274000 200
END APPLY >>> ./ R 00274000 00274000 $ 00274000 200
BEGIN APPLY >>> ./ R 00325000 00325000 $ 00325000 500
END APPLY >>> ./ R 00325000 00325000 $ 00325000 500
Update Succeeded
Update Execution Time 16 milliseconds.