DMKIOT History
References
-
-
Fixes Applied : 24
-
Last Fix ID : [R14597DK]
Update History
CMS File Input : DMKIOT ASSEMBLE
Date : 4/17/1979 4:17:00 AM
VM Context : MAINT(394)
File Name : DMKIOT.ASSEMBLE.Z1.txt
Modified : 1/16/2021 7:31:46 AM
Created : 1/16/2021 7:31:46 AM
Update Order
R09589DK 602 TURN OFF RDEVBUSY ON MSS CYLINDER FAULT
R09957DK - CORRECT IOBLOK CONFLICT IN MSS SUPPORT
R09137DK 606 MISSING LINE ON 3203 MOD 4
R08652DK 606 USER HUNG AFTER RESET AND DIAG 20
R09164DK 606 FRE001 DIAL BUG
R09738DK 609 PTF V09242 NOT ALLOWING FOR TIO IOB ON CU
R10398DK 609 CORRECTLY REFLECT IOERLEN WHEN SENSE FAILS
R09274DK 611 ABENDPRG005 IOBLOK FRETTED TWICE WHILE ERP HAS CONTROL
R09500DK 612 INCREASE RETRY COUNT
R11437DK 612 UV00936 CORRECTLY CHECK FOR DASD WHEN CHECK FOR D/T3330
R11460DK 614 UV01407 IMPROPER FAILING CCW USED IF USER CCW BEFORE PREFIX CCWS
R11455DK 615 UV01415 SPLIT OF DMKSSS INTO DMKSSS AND DMKSSU
R10176DK 615 UV01595 DMKIOS LOOP UNIT CHECK NOT SENSED AFTER HDV
R11340DK 616 ABENDFRE013 AFTER INSTALLATION OF VM08652
R12571DK 618 UV03178 REMOVE EXTRANEOUS EXTRNS
R12629DK 619 UV03782 LOOP TRYING TO ISSUE A SENSE TO A BUSY DEVICE
R13092DK 620 UV04054 ALLOW FOR STANDALONE INCORRECT LENGTH AFTER HIO
R12941DK 622 UV04884 SYNC ERROR RECOV FOR INTERVENTION REQUIRED COND.
R13728DK 623 UV05070 ALLOW I/O TO COMPLETE BEFORE GOING TO ERROR PROCESS
R14143DK 623 UV05163 RESET FLAGS (INCLUDING RDEVSCED)
R14003DK 624 UV05350 ISSUE SENSE FOR UNSOLICITED UNIT CHECK
R09325DK 625 UV02733 ALTERNATE PATH & MULT. CPU WAITS WITH VDEVCHBS.
R14489DK 625 UV05653 D/T3203 SINGLE CYCLE BUG WITH NO SILI IN CCW.
R14597DK 629 UV06302 PRESENT COMMAND REJECT IF WRITE TO R/O DASD
R09589DK
Date Wednesday Apr 18, 1979 04:03:00 AM
Loaded from MAINT(294)
R09589DK: ./ I 749000 $ 749100 100 00001000
R09589DK: NI RDEVSTAT,X'FF'-RDEVBUSY TURN OFF BUSY BIT @VA09589 00002000
BEGIN APPLY >>> ./ I 749000 $ 749100 100 00001000
END APPLY >>> ./ I 749000 $ 749100 100 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R09957DK
Date Thursday Jul 12, 1979 09:52:00 AM
Loaded from MAINT(294)
R09957DK: ./ * FORCE RE-ASSEMBLY FOR APAR VM09957
BEGIN APPLY >>> ./ * FORCE RE-ASSEMBLY FOR APAR VM09957
Comment >>> ./ * FORCE RE-ASSEMBLY FOR APAR VM09957
END APPLY >>> ./ * FORCE RE-ASSEMBLY FOR APAR VM09957
Update Succeeded
Update Execution Time 8 milliseconds.
R09137DK
Date Wednesday Oct 31, 1979 10:31:00 AM
Loaded from MAINT(294)
R09137DK: ./ R 999000 1015000 $ 999100 1000 00001000
R09137DK: IOTENSE EQU * HERE TO SENSE ALL UNITS @VA09137 00002000
R09137DK: TM IOBSPEC2,IOBSNSIO UC WHILE ATTEMPTING SENSE @VA09137 00003000
R09137DK: ./ I 1034000 $ 1034100 50 00004000
R09137DK: LM R0,R1,IOTSNCCW GET MODEL SENSE CCW @VA09137 00005000
R09137DK: ALR R0,R4 ADJUST DATA ADDRESS @VA09137 00006000
R09137DK: STM R0,R1,IOERCCW SAVE IN IOERBLOK @VA09137 00007000
R09137DK: OI IOBSPEC2,IOBUC FLAG ERROR TASK @VA09137 00008000
R09137DK: ./ R 1039000 $ 1039050 50 00009000
R09137DK: BNZ NOT3203 YES, GO AROUND 3203 CODE @VA09137 00010000
R09137DK: TM RDEVSTAT,RDEVDED DEVICE DEDICATED ? @VA09137 00011000
R09137DK: BNO IOTPERP NO,NO CHECK FOR 3203 @VA09137 00012000
R09137DK: CLC RDEVTYPC(2),=AL1(CLASURO,TYP3203) 3203 PRINTER? @VA09137 00013000
R09137DK: BNE IOTPERP NO, GET SENSE CCW @VA09137 00014000
R09137DK: CLC CSW+4(2),=AL1(CE+UC,0) SPECIAL 3203 INTERRUPT? @VA09137 00015000
R09137DK: BNE IOTPERP NO, GET SENSE CCW @VA09137 00016000
R09137DK: OI IOBSPEC3,IOBPST TELL VIO TO POST @VA09137 00017000
R09137DK: LR R3,R5 SAVE R5 IN R3 ACROSS BAL @VA09137 00018000
R09137DK: BAL R5,COPYIOB REFLECT THIS INTERRUPT @VA09137 00019000
R09137DK: LR R5,R3 RESTORE R5 @VA09137 00020000
R09137DK: NI IOBSPEC3,255-IOBPST TURN OFF POST @VA09137 00021000
R09137DK: B SNS3203 DO TIO @VA09137 00022000
R09137DK: NOT3203 EQU * @VA09137 00023000
R09137DK: ./ D 1042000 1045000 $ 00024000
R09137DK: ./ I 1063000 $ 1063100 50 00025000
R09137DK: SPACE 00026000
R09137DK: SNS3203 EQU * 3203 TIO CODE FOR 0A STATUS @VA09137 00027000
R09137DK: LH R1,IOBRADD GET REAL DEVICE ADDRESS @VA09137 00028000
R09137DK: XC CSW(8),CSW CLEAR CSW @VA09137 00029000
R09137DK: TIO 0(R1) IS IT BUSY ? @VA09137 00030000
R09137DK: BC 8+1,IOTETCAW GO AHEAD WITH SENSE @VA09137 00031000
R09137DK: BCR 2,R5 WAIT FOR DEVICE END @VA09137 00032000
R09137DK: TM CSW+4,DE DEVICE END ? @VA09137 00033000
R09137DK: BZR R5 NO, WAIT FOR IT @VA09137 00034000
R09137DK: OI IOBCSW+4,DE SET DE FOR REFLECTION @VA09137 00035000
R09137DK: B IOTETCAW GO DO SENSE @VA09137 00036000
BEGIN APPLY >>> ./ R 999000 1015000 $ 999100 1000 00001000
END APPLY >>> ./ R 999000 1015000 $ 999100 1000 00001000
BEGIN APPLY >>> ./ I 1034000 $ 1034100 50 00004000
END APPLY >>> ./ I 1034000 $ 1034100 50 00004000
BEGIN APPLY >>> ./ R 1039000 $ 1039050 50 00009000
END APPLY >>> ./ R 1039000 $ 1039050 50 00009000
BEGIN APPLY >>> ./ D 1042000 1045000 $ 00024000
END APPLY >>> ./ D 1042000 1045000 $ 00024000
BEGIN APPLY >>> ./ I 1063000 $ 1063100 50 00025000
END APPLY >>> ./ I 1063000 $ 1063100 50 00025000
Update Succeeded
Update Execution Time 16 milliseconds.
R08652DK
Date Wednesday Oct 31, 1979 08:29:00 AM
Loaded from MAINT(294)
R08652DK: ./ R 295000 302000 $ 294600 500 00001000
R08652DK: TM RDEVSTA2,RDEVRACT DEVICE RESET ? @VA08652 00002000
R08652DK: BZ IOTNODEV NO @VA08652 00003000
R08652DK: L R10,RDEVAIOB LOAD ACTIVE IOB @VA08652 00004000
R08652DK: LTR R10,R10 ACTIVE IOB ? @VA08652 00005000
R08652DK: BZ RSRESET NO, RESTART RESET @VA08652 00006000
R08652DK: L R1,IOBIOER MUST GET RID OF BLOCKS @VA08652 00007000
R08652DK: LTR R1,R1 IOERBLOK EXIST ? @VA08652 00008000
R08652DK: BZ NOIOER NO @VA08652 00009000
R08652DK: LA R0,IOERSIZE @VA08652 00010000
R08652DK: CALL DMKFRET @VA08652 00011000
R08652DK: NOIOER EQU * @VA08652 00012000
R08652DK: LR R1,R10 IOBLOK IN R1 @VA08652 00013000
R08652DK: LA R0,IOBSIZE @VA08652 00014000
R08652DK: CALL DMKFRET @VA08652 00015000
R08652DK: RSRESET EQU * @VA08652 00016000
BEGIN APPLY >>> ./ R 295000 302000 $ 294600 500 00001000
END APPLY >>> ./ R 295000 302000 $ 294600 500 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R09164DK
Date Monday Nov 12, 1979 11:12:00 AM
Loaded from MAINT(294)
R09164DK: ./ I 492000 $ 492150 150
R09164DK: TM RDEVSTA3,RDEVDIIP DIAL IN PROGRESS ? @VA09164 00002000
R09164DK: BNO NODIAL NO @VA09164 00003000
R09164DK: TM CSW+4,ATTN UNSOLICITED ATTENTION ? @VA09164 00004000
R09164DK: BO IOTGDISP YES, IGNORE @VA09164 00005000
R09164DK: NODIAL EQU * @VA09164 00006000
BEGIN APPLY >>> ./ I 492000 $ 492150 150
END APPLY >>> ./ I 492000 $ 492150 150
Update Succeeded
Update Execution Time 8 milliseconds.
R09738DK
Date Saturday Feb 09, 1980 07:26:00 AM
Loaded from MAINT(294)
R09738DK: ./ R 505000 $ 504300 300 00001000
R09738DK: BNZ ACTIOB YES, SEE IF TIO @VA09738 00002000
R09738DK: TM CSW+4,CUE CONTROL UNIT END ? @VA09738 00003000
R09738DK: BO IOTRSTCU START CONTROL UNIT @VA09738 00004000
R09738DK: B OFFLINE NO, FORGET IT @VA09738 00005000
R09738DK: ACTIOB EQU * @VA09738 00006000
BEGIN APPLY >>> ./ R 505000 $ 504300 300 00001000
END APPLY >>> ./ R 505000 $ 504300 300 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R10398DK
Date Saturday Feb 09, 1980 12:27:00 PM
Loaded from MAINT(294)
R10398DK: ./ R 1016000 $ 1016010 10 00001000
R10398DK: BO IOTENBAD TROUBLE -INTERRUPT TIME - SENSE @VA10398 00002000
R10398DK: ./ I 1104000 $ 1104010 10 00003000
R10398DK: MVC IOERLEN,ZEROES SENSE NOT AVAILABLE @VA10398 00004000
R10398DK: IOTENBAD DS 0H @VA10398 00005000
BEGIN APPLY >>> ./ R 1016000 $ 1016010 10 00001000
END APPLY >>> ./ R 1016000 $ 1016010 10 00001000
BEGIN APPLY >>> ./ I 1104000 $ 1104010 10 00003000
END APPLY >>> ./ I 1104000 $ 1104010 10 00003000
Update Succeeded
Update Execution Time 16 milliseconds.
R09274DK
Date Saturday Mar 29, 1980 12:13:00 PM
Loaded from MAINT(294)
R09274DK: ./ R 434000 442000 $ 434500 500 00001000
R09274DK: TM IOBFLAG,IOBERP ERP IN CONTROL ? @VA09274 00002000
R09274DK: BO CKSENS YES, CHECK NEXT @VA09274 00003000
R09274DK: TM IOBSPEC,IOBUNSL IF UNSOL-INT ? @VA09274 00004000
R09274DK: BZ IOTCKIOB NO, -- IOB IN CONTROL IOS -- @VA09274 00005000
R09274DK: CKSENS EQU * @VA09274 00006000
R09274DK: TM IOBSPEC2,IOBSNSIO DOING A SENSE ? @VA09274 00007000
R09274DK: BO IOTCKIOB YES, PROCESS INT @VA09274 00008000
R09274DK: TM RDEVSTAT,RDEVBUSY IS DEV BUSY ? @VA09274 00009000
R09274DK: BO IOTCKIOB YES, CHECK IOB @VA09274 00010000
R09274DK: TM IOBFLAG,IOBERP ERP IN CONTROL ? @VA09274 00011000
R09274DK: BO IOTGDISP YES, IGNORE THIS INT @VA09274 00012000
R09274DK: B IOTCKIOB GO TO CHECK IOB STATUS @VA09274 00013000
BEGIN APPLY >>> ./ R 434000 442000 $ 434500 500 00001000
END APPLY >>> ./ R 434000 442000 $ 434500 500 00001000
Update Succeeded
Update Execution Time 8 milliseconds.
R09500DK
Date Monday May 05, 1980 04:11:00 AM
Loaded from MAINT(294)
R09500DK: ./ R 411000 $ 411100 00001000
R09500DK: CLI RDEVTYPC,CLASGRAF GRAF DEVICE? @VA09500 00002000
R09500DK: ./ I 412000 $ 412100 10 00003000
R09500DK: TM RDEVTYPE,TYP3277+TYP3284 3277 OR 3284? @VA09500 00004000
R09500DK: BZ NO3270 NO - BRANCH @VA09500 00005000
R09500DK: ./ R 1073000 $ 1073100 00006000
R09500DK: CLI RDEVTYPC,CLASGRAF GRAF DEVICE? @VA09500 00007000
R09500DK: ./ I 1074000 $ 1074100 10 00008000
R09500DK: TM RDEVTYPE,TYP3277+TYP3284 3277 OR 3284? @VA09500 00009000
R09500DK: BZ IOTNSIO1 NO - BRANCH @VA09500 00010000
R09500DK: ./ I 1076000 $ 1076100 00011000
R09500DK: RETYCNT DC F'40000' RETRY COUNT @VA09500 00012000
R09500DK: ./ R 1078000 $ 1078100 00013000
R09500DK: L R15,RETYCNT LOAD RETRY COUNT @VA09500 00014000
R09500DK: ./ R 1085000 1086000 $ 1085100 100 00015000
R09500DK: CLI RDEVTYPC,CLASGRAF GRAF DEVICE @VA09500 00016000
R09500DK: BNE NOTGRAF1 NO-BRANCH @VA09500 00017000
R09500DK: TM RDEVTYPE,TYP3277+TYP3284 @VA09500 00018000
R09500DK: BM IOTINBAD IF EITHER LIMITED RETRY @VA09500 00019000
R09500DK: NOTGRAF1 DS 0H @VA09500 00020000
R09500DK: ./ R 1091000 1092000 $ 1091100 100 00021000
R09500DK: CLI RDEVTYPC,CLASGRAF GRAF DEVICE @VA09500 00022000
R09500DK: BNE NOTGRAF2 NO-BRANCH @VA09500 00023000
R09500DK: TM RDEVTYPE,TYP3277+TYP3284 @VA09500 00024000
R09500DK: BM ROUT3277 @VA09500 00025000
R09500DK: NOTGRAF2 DS 0H @VA09500 00026000
BEGIN APPLY >>> ./ R 411000 $ 411100 00001000
END APPLY >>> ./ R 411000 $ 411100 00001000
BEGIN APPLY >>> ./ I 412000 $ 412100 10 00003000
END APPLY >>> ./ I 412000 $ 412100 10 00003000
BEGIN APPLY >>> ./ R 1073000 $ 1073100 00006000
END APPLY >>> ./ R 1073000 $ 1073100 00006000
BEGIN APPLY >>> ./ I 1074000 $ 1074100 10 00008000
END APPLY >>> ./ I 1074000 $ 1074100 10 00008000
BEGIN APPLY >>> ./ I 1076000 $ 1076100 00011000
END APPLY >>> ./ I 1076000 $ 1076100 00011000
BEGIN APPLY >>> ./ R 1078000 $ 1078100 00013000
END APPLY >>> ./ R 1078000 $ 1078100 00013000
BEGIN APPLY >>> ./ R 1085000 1086000 $ 1085100 100 00015000
END APPLY >>> ./ R 1085000 1086000 $ 1085100 100 00015000
BEGIN APPLY >>> ./ R 1091000 1092000 $ 1091100 100 00021000
END APPLY >>> ./ R 1091000 1092000 $ 1091100 100 00021000
Update Succeeded
Update Execution Time 23 milliseconds.
R11437DK
Date Monday May 05, 1980 04:21:00 AM
Loaded from MAINT(294)
R11437DK: ./ R 574000 $ 574010 00001000
R11437DK: CLC RDEVTYPC(2),=AL1(CLASDASD,TYP3330) IS IT A 3330 @VA11437 00002000
R11437DK: ./ R 734000 $ 734010 00003000
R11437DK: CLC RDEVTYPC(2),=AL1(CLASDASD,TYP3330) IS IT A 3330 @VA11437 00004000
BEGIN APPLY >>> ./ R 574000 $ 574010 00001000
END APPLY >>> ./ R 574000 $ 574010 00001000
BEGIN APPLY >>> ./ R 734000 $ 734010 00003000
END APPLY >>> ./ R 734000 $ 734010 00003000
Update Succeeded
Update Execution Time 16 milliseconds.
R11460DK
Date Monday Jun 30, 1980 05:30:00 AM
Loaded from MAINT(294)
R11460DK: ./ R 00617000 00618000 $ 00617100 100 00001000
R11460DK: L R15,IOERCSW ADDRESS OF FAILING CSW +8 @VA11460 00002000
R11460DK: CR R15,R14 SEE IF UC IN THE PREFIX @VA11460 00003000
R11460DK: BL IOTCHKUC NO, MUST BE USER CCW @VA11460 00004000
R11460DK: LA R14,PREL(R14) FIRST CCW PAST THE PREFIX @VA11460 00005000
BEGIN APPLY >>> ./ R 00617000 00618000 $ 00617100 100 00001000
END APPLY >>> ./ R 00617000 00618000 $ 00617100 100 00001000
Update Succeeded
Update Execution Time 8 milliseconds.
R11455DK
Date Friday Jul 25, 1980 06:04:00 AM
Loaded from MAINT(294)
R11455DK: ./ R 177000 $ 177010 00001000
R11455DK: EXTRN DMKSSUI1,DMKSSUI2 @VA11455 00002000
R11455DK: ./ R 1150000 1151000 $ 1150010 10 00003000
R11455DK: SSSI1ADD DC V(DMKSSUI1) @VA11455 00004000
R11455DK: SSSI2ADD DC V(DMKSSUI2) @VA11455 00005000
BEGIN APPLY >>> ./ R 177000 $ 177010 00001000
END APPLY >>> ./ R 177000 $ 177010 00001000
BEGIN APPLY >>> ./ R 1150000 1151000 $ 1150010 10 00003000
END APPLY >>> ./ R 1150000 1151000 $ 1150010 10 00003000
Update Succeeded
Update Execution Time 16 milliseconds.
R10176DK
Date Friday Jul 25, 1980 06:20:00 AM
Loaded from MAINT(294)
R10176DK: ./ I 304000 $ 304020 20 RELEASE 6 FIX 00001000
R10176DK: TM RDEVSTAT,RDEVSCED I/O Q'D FROM C.U. OR CHAN? @VA10176 00002000
R10176DK: BNO NONEQUED NO, FORGET THE SEARCH @VA10176 00003000
R10176DK: L R10,RCUFIOB CHECK IF IOB OFF CTLUNIT @VA10176 00004000
R10176DK: CUCKLOOP EQU * @VA10176 00005000
R10176DK: CR R7,R10 IS THIS THE LAST ONE? @VA10176 00006000
R10176DK: BE CHKCHAN YES, CHECK IF IOB OFF CHANNEL @VA10176 00007000
R10176DK: CLC IOBRADD(2),INTTIO IS THIS FOR US? @VA10176 00008000
R10176DK: BE CUCKOUT YES, GO DEQUEUE IT @VA10176 00009000
R10176DK: L R10,IOBFPNT-IOBLOK(R10) NO, CHECK NEXT IOBLOK @VA10176 00010000
R10176DK: B CUCKLOOP ... @VA10176 00011000
R10176DK: CUCKOUT EQU * @VA10176 00012000
R10176DK: LH R1,RCUQCNT DECREASE QUEUED COUNT @VA10176 00013000
R10176DK: BCTR R1,0 ... @VA10176 00014000
R10176DK: STH R1,RCUQCNT ... @VA10176 00015000
R10176DK: B FNDIOB CONTINUE @VA10176 00016000
R10176DK: CHKCHAN EQU * @VA10176 00017000
R10176DK: L R10,RCHFIOB FIRST IOB ON CHANNEL @VA10176 00018000
R10176DK: CHKCHAN1 EQU * @VA10176 00019000
R10176DK: CR R6,R10 IS THIS THE END OF CHAIN? @VA10176 00020000
R10176DK: BE NONEQUED YES, NORMAL PROCESSING @VA10176 00021000
R10176DK: CLC IOBRADD(2),INTTIO IS THIS ONE FOR US? @VA10176 00022000
R10176DK: BE CHCLOOP1 YES, GO DEQUEQE IT @VA10176 00023000
R10176DK: L R10,IOBFPNT-IOBLOK(R10) NO, CHECK NEXT ONE @VA10176 00024000
R10176DK: B CHKCHAN1 CONTINUE @VA10176 00025000
R10176DK: CHCLOOP1 EQU * @VA10176 00026000
R10176DK: LH R1,RCHQCNT DECREASE QUEUED COUNT @VA10176 00027000
R10176DK: BCTR R1,0 ... @VA10176 00028000
R10176DK: STH R1,RCHQCNT ... @VA10176 00029000
R10176DK: FNDIOB EQU * @VA10176 00030000
R10176DK: LM R4,R5,IOBFPNT-IOBLOK(R10) DEQUEUE IOBLOK @VA10176 00031000
R10176DK: ST R4,IOBFPNT-IOBLOK(R5) ... @VA10176 00032000
R10176DK: ST R5,IOBBPNT-IOBLOK(R4) ... @VA10176 00033000
R10176DK: NI RDEVSTAT,X'FF'-RDEVBUSY+RDEVSCED RESET FLAGS @VA10176 00034000
R10176DK: B IOTTART @VA10176 00035000
R10176DK: NONEQUED EQU * @VA10176 00036000
BEGIN APPLY >>> ./ I 304000 $ 304020 20 RELEASE 6 FIX 00001000
END APPLY >>> ./ I 304000 $ 304020 20 RELEASE 6 FIX 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R11340DK
Date Friday Sep 26, 1980 09:04:00 AM
Loaded from MAINT(294)
R11340DK: ./ R 294600 301600 $ 295000 00001000
R11340DK: TM RDEVTYPC,CLASTAPE TAPE DEVICE?? @VA11340 00002000
R11340DK: BZ NOTTAPES NO SKIP @VA11340 00003000
R11340DK: L R4,RDEVAIOB IS IT UNSOLICITED?? @VA11340 00004000
R11340DK: LTR R4,R4 INTERRUPT @VA11340 00005000
R11340DK: BZ IOTNODEV YES, INVESTIGATE @VA11340 00006000
R11340DK: NOTTAPES EQU * @VA11340 00007000
R11340DK: TM RDEVSTA2,RDEVRACT IS THIS DEVICE BEING RESET? @VA11340 00008000
R11340DK: BZ IOTNODEV NOPE, BR. @VA11340 00009000
BEGIN APPLY >>> ./ R 294600 301600 $ 295000 00001000
END APPLY >>> ./ R 294600 301600 $ 295000 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R12571DK
Date Friday Jan 09, 1981 12:04:00 PM
Loaded from MAINT(294)
R12571DK: ./ D 142000 145000 $
R12571DK: ./ D 171000 $
BEGIN APPLY >>> ./ D 142000 145000 $
END APPLY >>> ./ D 142000 145000 $
BEGIN APPLY >>> ./ D 171000 $
END APPLY >>> ./ D 171000 $
Update Succeeded
Update Execution Time 16 milliseconds.
R12629DK
Date Thursday Feb 12, 1981 02:12:00 AM
Loaded from MAINT(294)
R12629DK: ./ R 1093000 $ 1093100 100 00001000
R12629DK: CLI CSW+4,BUSY IS IT JUST A DEVICE BUSY @VA12629 00002000
R12629DK: BE IOTINBAD YES USE LIMITED RETRY @VA12629 00003000
R12629DK: TM CSW+4,SM+CUE+BUSY CUE OR CU PENDING @VA12629 00004000
BEGIN APPLY >>> ./ R 1093000 $ 1093100 100 00001000
END APPLY >>> ./ R 1093000 $ 1093100 100 00001000
Update Succeeded
Update Execution Time 8 milliseconds.
R13092DK
Date Tuesday Apr 07, 1981 03:30:00 AM
Loaded from MAINT(294)
R13092DK: ./ R 452000 $ 452100 100 00001000
R13092DK: TM CSW+5,PCI+IL @VA13092 00002000
BEGIN APPLY >>> ./ R 452000 $ 452100 100 00001000
END APPLY >>> ./ R 452000 $ 452100 100 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R12941DK
Date Tuesday Jul 07, 1981 01:33:00 PM
Loaded from MAINT(294)
R12941DK: ./ R 711000 712000 $ 711000 100
R12941DK: BZ IOTER ERROR RECOVERY NOT IN PROCESS @VA12941
R12941DK: TM RDEVSTAT,RDEVNRDY INTERVENTION REQUIRED PENDING @VA12941
R12941DK: BZ IOTRSTCU NO, IGNORE THIS INTERRUPT @VA12941
R12941DK: TM CSW+4,DE+ATTN NOT-READY TO READY SEQUENCE @VA12941
R12941DK: BZ IOTRSTCU NO, IGNORE THIS INTERRUPT @VA12941
R12941DK: IOTER OI IOBSPEC2,IOBRETRY CONTINUE WITH ERROR RECOVERY @VA12941
BEGIN APPLY >>> ./ R 711000 712000 $ 711000 100
END APPLY >>> ./ R 711000 712000 $ 711000 100
Update Succeeded
Update Execution Time 16 milliseconds.
R13728DK
Date Friday Aug 07, 1981 07:30:00 AM
Loaded from MAINT(294)
R13728DK: ./ R 667000 $ 667100 100 00001000
R13728DK: BZ IOTCKBSY NO, SEE IF DEVICE IS STILL BUSY @VA13728 00002000
R13728DK: CLI IOBCSW+4,CE CE ALONE ON CH PGM RESTART ? @VA13728 00003000
R13728DK: BE IOTRSTCU WAIT FOR I/O BEFORE RETURN TO @VA13728 00004000
R13728DK: B IOTCPERR RETURN CONTROL TO ERP NOW @VA13728 00005000
BEGIN APPLY >>> ./ R 667000 $ 667100 100 00001000
END APPLY >>> ./ R 667000 $ 667100 100 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R14143DK
Date Friday Aug 14, 1981 08:12:00 AM
Loaded from MAINT(294)
R14143DK: ./ R 304660 $ 304661 00001000
R14143DK: NI RDEVSTAT,X'FF'-(RDEVBUSY+RDEVSCED) RESET FLAGS @VA14143 00002000
BEGIN APPLY >>> ./ R 304660 $ 304661 00001000
END APPLY >>> ./ R 304660 $ 304661 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R14003DK
Date Friday Sep 11, 1981 02:20:00 PM
Loaded from MAINT(294)
R14003DK: ./ R 439500 440000 $ 439600 100 00001000
R14003DK: BZ IOTCKIOB NO; GO CHECK IOB STATUS @VA14003 00002000
R14003DK: TM CSW+4,UC YES; IS THERE ANOTHER UNIT CHECK? @VA14003 00004000
R14003DK: BO CNTNGNCY YES; GO CLEAR CONTINGENCY @VA14003 00005000
R14003DK: B IOTGDISP NO; IGNORE THIS INTERRUPT @VA14003 00007000
BEGIN APPLY >>> ./ R 439500 440000 $ 439600 100 00001000
END APPLY >>> ./ R 439500 440000 $ 439600 100 00001000
Update Succeeded
Update Execution Time 8 milliseconds.
R09325DK
Date Wednesday Oct 21, 1981 11:48:00 AM
Loaded from MAINT(294)
R09325DK: ./ I 410000 $ 410100 100 00001000
R09325DK: CLC INTTIO(2),IOBRADD @VA09325 00002000
R09325DK: BNE IOTGDISP @VA09325 00003000
BEGIN APPLY >>> ./ I 410000 $ 410100 100 00001000
END APPLY >>> ./ I 410000 $ 410100 100 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R14489DK
Date Tuesday Oct 27, 1981 01:53:00 PM
Loaded from MAINT(294)
R14489DK: ./ R 1039350 $ 1039360 5 00001000
R14489DK: BE SPECINT SPECIAL 3203 INTERRUPT @VA14489 00002000
R14489DK: CLC CSW+4(2),=AL1(CE+UC+IL,0) SPECIAL 3203 @VA14489 00003000
R14489DK: * INTERRUPT? 00004000
R14489DK: BNE IOTPERP NO, GET SENSE CCW @VA14489 00005000
R14489DK: SPECINT EQU * @VA14489 00006000
BEGIN APPLY >>> ./ R 1039350 $ 1039360 5 00001000
END APPLY >>> ./ R 1039350 $ 1039360 5 00001000
Update Succeeded
Update Execution Time 16 milliseconds.
R14597DK
Date Thursday Apr 01, 1982 02:48:00 PM
Loaded from MAINT(294)
R14597DK: ./ I 570000 $ 570100 50 00001000
R14597DK: CLI RDEVTYPC,CLASDASD IS THIS A DASD DEVICE @VA14597 00002000
R14597DK: BNE NORDOCK NO-GET OUT @VA14597 00003000
R14597DK: SR R15,R15 CLEAR OUT REG 15 @VA14597 00004000
R14597DK: ICM R15,B'0111',IOERCSW+1 FAILING CSW+8 @VA14597 00005000
R14597DK: BZ NORDOCK NO IOERCSW-THEN GET OUT @VA14597 00006000
R14597DK: S R15,F8 SUB 8 FAILING CCW @VA14597 00007000
R14597DK: CLI 0(R15),X'FE' WRITE TO READ ONLY DISK @VA14597 00008000
R14597DK: BNE NORDOCK NO-GET OUT @VA14597 00009000
R14597DK: CLI IOERDATA,CMDREJ IS IT A COMMAND REJECT @VA14597 00010000
R14597DK: BNE NORDOCK NO-GET OUT @VA14597 00011000
R14597DK: MVI IOERDATA+1,X'02' TURN ON WRITE INHIBIT SW. @VA14597 00012000
R14597DK: NORDOCK EQU * @VA14597 00013000
BEGIN APPLY >>> ./ I 570000 $ 570100 50 00001000
END APPLY >>> ./ I 570000 $ 570100 50 00001000
Update Succeeded
Update Execution Time 8 milliseconds.