*NOSEQ CMRINST INSTRUCTIONS FOR INITIAL SETUP OF THE OPERATING SYSTEM. USE + KEY TO SEE NEXT PAGE. NEXT. WILL CAUSE THE LOAD TO CONTINUE. IPR. WILL CONTINUE THE LOAD TO THE *IPRDECK* DISPLAY. GO. WILL CONTINUE THE LOAD WITHOUT FURTHER DISPLAYS. THE RIGHT BLANK KEY ADVANCES THE DISPLAY. BSP=X. BUILD *SCI* PARAMETER TABLE IF X=Y, OR DO NOT BUILD IF X=N. IT IS BUILT BY DEFAULT. CLT=N. SET CLT LENGTH = N OCTAL ENTRIES. N=0-7777B. DEFAULT IS 0. DFT=X. SET *DFT* TO DEDICATED MODE, IF X=D, OR TO NON-DEDICATED MODE, IF X=N. (THE *VE* ENTRY WILL ALSO FORCE DEDICATED MODE). DUALCPU=X. SET THE DUAL CPU MODE FOR DUAL STATE (960 ONLY). X = N, TO DEDICATE SECOND CPU TO NOS. X = V, TO DEDICATE SECOND CPU TO NOS/VE. DEFAULT IS DUALCPU=V. EJT=N. SET EJT LENGTH = N OCTAL ENTRIES. N=3-7777B. DEFAULT IS 620B. EMB=N. SET ERROR MESSAGE BUFFER LENGTH = N OCTAL WORDS. N=200B-7777B. DEFAULT IS 200B. EQP=NN. ASSEMBLE EQUIPMENT PARAMETER DECK EQPDNN. NN=00-77B. DEFAULT IS SAME NUMBER AS CMRDECK. FNT=N. SET FNT LENGTH = N OCTAL ENTRIES. N=3-7777B. DEFAULT IS 23B. FOT=N. SET FOT LENGTH = N OCTAL ENTRIES. N=3-100B. DEFAULT IS 10B. INB=N. SET INSTALLATION BLOCK LENGTH = N OCTAL WORDS. N=0-7777B. DEFAULT IS 0. IPD=NN. ASSEMBLE INSTALLATION PARAMETER DECK IPRDNN. NN=00-77B. DEFAULT IS FIRST IPRDECK FOUND. LIB=NN. BUILD SYSTEM USING LIBDECK LIBDNN. NN=00-77B. DEFAULT IS LIBD00. LDT=N. SET NUMBER OF WORDS TO BE RESERVED FOR THE LID TABLE. N=0-1100B. DEFAULT IS 1. MID=MM. SET MACHINE IDENTIFIER = MM. MM=TWO ALPHANUMERIC CHARACTERS. DEFAULT IS AA. MINCM=N. SET THE MINIMUM AMOUNT OF NOS CENTRAL MEMORY = N HUNDRED OCTAL WORDS. THE ACTUAL AMOUNT OF MEMORY USED AS NOS CENTRAL MEMORY WILL BE (PHYSICAL SIZE) - (UEM SIZE) - (NOS/VE SIZE). N=ONE TO FOUR DIGIT OCTAL VALUE. N=ONE TO FIVE DIGIT OCTAL VALUE FOR 865, 875 AND 180 CLASS MODELS. DEFAULT AND MINIMUM IS 1400B (49K). MLST=NN. SET THE SIZE OF THE MESSAGE LINK STATUS TABLE. NN=0-77B WORDS. DEFAULT=17B. DUAL STATE ONLY. NAME=CC-CC. SET THE SYSTEM NAME = CC-CC. CC-CC IS .LE. 38 ALPHANUMERIC CHARACTERS. NCP=N. SET THE NUMBER OF CONTROL POINTS = N. N=2-34B. DEFAULT IS 12B. OPSECM=N. SET THE SECURITY MODE OF THE SYSTEM. N =0-3 (SECURITY MODE). DEFAULT IS 0 (UNSECURED MODE). ORT=N. SET ORT LENGTH = N OCTAL ENTRIES. N=0-7777B. DEFAULT IS 100B. PCP=N. SET THE NUMBER OF PSEUDO-CONTROL POINTS = N. N=0-34B. DEFAULT IS 0. QFT=N. SET QFT LENGTH = N OCTAL ENTRIES. N=3-7777B. DEFAULT IS 620B. VE=N. SET SIZE OF RESERVED NOS/VE MEMORY TO N THOUSAND OCTAL WORDS. REQUIRED TO RUN DUAL STATE. N=0 WILL CAUSE DYNAMIC MEMORY ALLOCATION. N=* WILL CLEAR ENTRY (NO DUAL STATE POSSIBLE). DEFAULT = *. VERSION=CC-CC. SET VERSION NAME = CC-CC. CC-CC IS .LE. 18 ALPHANUMERIC CHARACTERS. *WEOR *WEOR