User Tools

Site Tools


Action unknown: copypageplugin__copy
cdc:nos2.source:opl.opl871:deck:1tm.003

Deck 1TM Part 003

22 Modifications

Listing Sections

Source

Seq #  *Modification Id* Act 
----------------------------+
05332  M01S04806.242l642 ---| ERR      BSS    0           ENTRY
05333  M01S04807.242l642 ---|          ZJN    ERR2        IF NO DAYFILE MESSAGE
05334  M01S04808.242l642 ---| ERR1     RJM    DFM         ISSUE DAYFILE MESSAGE
05335  M01S04809.242l642 ---| ERR2     JMP    DPP         DROP PPU
05336  M01S04810.242l642 ---|
Line S04811 Modification History
M01 (Removed by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05337  M02S04811.242l642 ---|*         ERR - SECONDARY ENTRY POINTS.
Line S00097 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05338  M02S00097.242l642 ---|*         ENTER HERE ON MULTIPLEXER RESERVATION ERROR.
Line S04812 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05339  M01S04812.242l642 ---|
Line S04813 Modification History
M01 (Removed by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05340  M02S04813.242l642 ---| ERR=1    LDC    =C* 1TM - NO TPM AVAILABLE.*
Line S00098 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05341  M02S00098.242l642 ---| MRER     BSS    0           MULTIPLEXER RESERVATION ERROR
05342  M02S00099.242l642 ---|          LDC    =C* 1TM - NO TPM AVAILABLE.*
Line S04814 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05343  M01S04814.242l642 ---|          UJN    ERR1        ISSUE DAYFILE MESSAGE
Line S00031 Modification History
M01 (Added by) v23l617
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05344  M02S00031.242l642 ---|
05345  M02S00032.242l642 ---|*         ENTER HERE ON PORT USAGE ERROR.
05346  M02S00033.242l642 ---|
05347  M02S00034.242l642 ---| PUER     BSS    0           PORT USAGE ERROR
05348  M02S00035.242l642 ---|          LDC    =C* 1TM - RDF ATTEMPT TO USE CONSOLE PORT.*
05349  M02S00036.242l642 ---|          UJN    ERR1        ISSUE DAYFILE MESSAGE
05350  M02S00037.242l642 ---|
Line S00100 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05351  M02S00100.242l642 ---|
05352  M02S00101.242l642 ---|
05353  M02S00102.242l642 ---| ERRB     DATA   C* 1TM - RMEEE CXX PYY FNNNN REJECT.*
Line S04815 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05354  M01S04815.242l642 ---| O2D      SPACE  4,15
05355  M01S04816.242l642 ---|**        O2D - CONVERT TWO DIGITS TO OCTAL DISPLAY CODE.
05356  M01S04817.242l642 ---|*
05357  M01S04818.242l642 ---|*         ENTRY  (A) = TWO OCTAL DIGITS TO BE CONVERTED.
05358  M01S04819.242l642 ---|*
05359  M01S04820.242l642 ---|*         EXIT   (A) = DISPLAY CODE CONVERSION.
05360  M01S04821.242l642 ---|
05361  M01S04822.242l642 ---|
05362  M01S04823.242l642 ---| O2D      SUBR               ENTRY/EXIT
05363  M01S04824.242l642 ---|          LPN    77          MASK EXTRANEOUS BITS
05364  M01S04825.242l642 ---|          STD    T0          SAVE OCTAL VALUE
05365  M01S04826.242l642 ---|          SHN    3           SPLIT UPPER AND LOWER 3-BIT VALUES
05366  M01S04827.242l642 ---|          LMD    T0
05367  M01S04828.242l642 ---|          SCN    70
05368  M01S04829.242l642 ---|          ADC    2R00        CONVERT DIGITS
05369  M01S04830.242l642 ---|          UJN    O2DX        RETURN
Line S00324 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05370  M01S00324.242l642 +++| FTER     SPACE  4,10
05371  M01S00325.242l642 +++|**        FTER - FUNCTION TIME-OUT ERROR PROCESSOR.
05372  M01S00326.242l642 +++|*
05373  M01S00327.242l642 +++|*         ENTRY  (A) = FUNCTION CODE.
05374  M01S00328.242l642 +++|*
05375  M01S00329.242l642 +++|*         EXIT   (A) = 1/ERROR LOG FLAG, 5/MESSAGE NUMBER.
05376  M01S00330.242l642 +++|
05377  M01S00331.242l642 +++|
05378  M01S00332.242l642 +++| FTER     BSS    0           ENTRY
05379  M01S00333.242l642 +++|          STM    IMTB        SAVE FUNCTION CODE
05380  M01S00334.242l642 +++|          LDN    MFTO+40     * RMEEE CXX PYY FNNNN REJECT.*
05381  M01S00335.242l642 +++|*         JMP    IMT         ISSUE MESSAGE AND TERMINATE
05382  M01S00336.242l642 +++| IMT      SPACE  4,10
05383  M01S00337.242l642 +++|**        IMT - ISSUE MESSAGE AND TERMINATE.
05384  M01S00338.242l642 +++|*
05385  M01S00339.242l642 +++|*         ENTRY  (A) = 1/ERROR LOG FLAG, 5/MESSAGE NUMBER.
05386  M01S00340.242l642 +++|*
05387  M01S00341.242l642 +++|*         EXIT   TO *4TM*.
05388  M01S00342.242l642 +++|*
05389  M01S00343.242l642 +++|*         MACROS EXECUTE.
05390  M01S00344.242l642 +++|
05391  M01S00345.242l642 +++|
05392  M01S00346.242l642 +++| IMT      BSS    0           ENTRY
05393  M01S00347.242l642 +++|          STM    IMTA        SAVE MESSAGE REQUEST
05394  M01S00348.242l642 +++|          EXECUTE  4TM
05395  M01S00349.242l642 +++|          LJM    DPP         DROP PP
05396  M01S00350.242l642 +++|
05397  M01S00351.242l642 +++|
05398  M01S00352.242l642 +++| IMTA     BSS    1           MESSAGE REQUEST
05399  M01S00353.242l642 +++| IMTB     BSS    1           FUNCTION CODE
05400  M01S00354.242l642 +++| MRER     SPACE  4,10
05401  M01S00355.242l642 +++|**        MRER - NORMAL ERROR PROCESSOR FOR *COMPMRA*.
05402  M01S00356.242l642 +++|*
05403  M01S00357.242l642 +++|*         EXIT   (A) = MESSAGE NUMBER.
05404  M01S00358.242l642 +++|
05405  M01S00359.242l642 +++|
05406  M01S00360.242l642 +++| MRER     BSS    0           ENTRY
05407  M01S00361.242l642 +++|          LDN    MNTA        * NO TPM AVAILABLE.*
05408  M01S00362.242l642 +++|          UJN    IMT         ISSUE MESSAGE AND TERMINATE
Line S04831 Modification History
M01 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05409  M01S04831.ns2149  ---| RCE       SPACE 4,15
05410  M01S04832.ns2149  ---|**        RCE - RESERVE CHANNEL AND EQUIPMENT.
05411  M01S04833.ns2149  ---|*
Line S00014 Modification History
M01 (Added by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05412  M02S00014.ns2149  ---|*         ENTRY  (RCEA) = UPPER ACCESS LEVEL LIMIT OF TPM.
05413  M02S00015.ns2149  ---|*
Line S04834 Modification History
M01 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05414  M01S04834.ns2149  ---|*         EXIT   EQUIPMENT AND CHANNEL RESERVED.
05415  M01S04835.ns2149  ---|*                (EQ) = BIT 2**9 SET TO INDICATE THAT CHANNEL
05416  M01S04836.ns2149  ---|*                       AND EQUIPMENT ARE RESERVED.
Line S00016 Modification History
M01 (Added by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05417  M02S00016.ns2149  ---|*                MUX TABLE ENTRY UPDATED WITH CH, PN, AND UAL.
Line S04837 Modification History
M01 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05418  M01S04837.ns2149  ---|*
05419  M01S04838.ns2149  ---|*         ERROR  TO *ERR* IF EQUIPMENT NOT ASSIGNED.
05420  M01S04839.ns2149  ---|*
05421  M01S04840.ns2149  ---|*         USES   CM - CM+4.
05422  M01S04841.ns2149  ---|*
05423  M01S04842.ns2149  ---|*         MACROS CHTE, RCHAN, MONITOR.
05424  M01S04843.ns2149  ---|
05425  M01S04844.ns2149  ---|
05426  M01S04845.ns2149  ---| RCE      SUBR               ENTRY/EXIT
05427  M01S04846.ns2149  ---|          LDD    EQ          CHECK EQUIPMENT
05428  M01S04847.ns2149  ---|          STD    CM+1
05429  M01S04848.ns2149  ---|          SBD    TH
05430  M01S04849.ns2149  ---|          PJN    RCEX        IF ALREADY RESERVED
05431  M01S04850.ns2149  ---|          MONITOR REQM       REQUEST EQUIPMENT
05432  M01S04851.ns2149  ---|          LDD    CM+1
05433  M01S04852.ns2149  ---|          ZJP    ERR=1       * 1TM - NO TPM AVAILABLE.*
05434  M01S04853.ns2149  ---|          LDN    MC          REQUEST CHANNEL
05435  M01S04854.ns2149  ---|          CHTE   *-1
05436  M01S04855.ns2149  ---|          RCHAN
Line S04856 Modification History
M01 (Removed by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05437  M02S04856.ns2149  ---|          LDD    TH          SET BIT 2**9 ON EQUIPMENT NUMBER
Line S00017 Modification History
M01 (Added by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05438  M02S00017.ns2149  ---|          LDD    TH          SET BIT 2**9 ON EST ORDINAL
Line S04857 Modification History
M01 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05439  M01S04857.ns2149  ---|          RAD    EQ
Line S00018 Modification History
M01 (Added by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05440  M02S00018.ns2149  ---|          LDD    RA          READ MUX TABLE ENTRY
05441  M02S00019.ns2149  ---|          SHN    6
05442  M02S00020.ns2149  ---|          ADC    MUXP+VMTM
05443  M02S00021.ns2149  ---|          CRD    CM
05444  M02S00022.ns2149  ---|          LDN    MC          SET CHANNEL
05445  M02S00023.ns2149  ---|          CHTE   *-1
05446  M02S00024.ns2149  ---|          SHN    6
05447  M02S00025.ns2149  ---|          LMD    PN          SET PORT NUMBER
05448  M02S00026.ns2149  ---|          STD    CM
05449  M02S00027.ns2149  ---|          LDC    *           SET UPPER ACCESS LEVEL LIMIT FOR MUX
05450  M02S00028.ns2149  ---| RCEA     EQU    *-1
05451  M02S00029.ns2149  ---|          STD    CM+2
05452  M02S00030.ns2149  ---|          LDD    RA          REWRITE MUX TABLE ENTRY
05453  M02S00031.ns2149  ---|          SHN    6
05454  M02S00032.ns2149  ---|          ADC    MUXP+VMTM
05455  M02S00033.ns2149  ---|          CWD    CM
Line S04858 Modification History
M01 (Removed by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05456  M02S04858.ns2149  ---|          UJN    RCEX        RETURN
Line S00034 Modification History
M01 (Added by) ns22000
M02 (Removed by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05457  M02S00034.ns2149  ---|          UJP    RCEX        RETURN
05458  M00S04859.1tm     +++| RCL      SPACE  4,15
05459  M00S04860.1tm     +++|**        RCL - RECALL PPU.
05460  M00S04861.1tm     +++|*
05461  M00S04862.1tm     +++|*         REQUESTS PPU RECALL AFTER DEFINED DELAY PERIOD,
05462  M00S04863.1tm     +++|*         THEN EXITS TO PPU RESIDENT.
05463  M00S04864.1tm     +++|*
05464  M00S04865.1tm     +++|*         ENTRY  (IR - IR+4) = PPU INPUT REGISTER.
05465  M00S04866.1tm     +++|*
05466  M00S04867.1tm     +++|*         EXIT   TO *PPR*.
Line S00363 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05467  M01S00363.242l642 +++|*                (IR+2) = 10/EQ, 1/S, 1/P.
05468  M01S00364.242l642 +++|*                         EQ = RESERVED EQUIPMENT NUMBER.
05469  M01S00365.242l642 +++|*                         S = 1, IF PORT CURRENTLY IS RESERVED FOR
05470  M01S00366.242l642 +++|*                             *1TM*.
05471  M01S00367.242l642 +++|*                         P = PORT NUMBER.
05472  M00S04868.1tm     +++|*
05473  M00S04869.1tm     +++|*         USES   CM - CM+4.
Line S04870 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05474  M01S04870.242l642 ---|*
05475  M01S04871.242l642 ---|*         CALLS  DCE.
05476  M00S04872.1tm     +++|*
Line S04873 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05477  M01S04873.242l642 ---|*         MACROS MONITOR.
Line S00368 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05478  M01S00368.242l642 +++|*         MACROS DCHAN, MONITOR.
05479  M00S04874.1tm     +++|
05480  M00S04875.1tm     +++|
05481  M00S04876.1tm     +++| RCL      BSS    0           ENTRY
Line S04877 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05482  M01S04877.242l642 ---|          RJM    DCE         DROP CHANNEL AND EQUIPMENT
05483  M01S04878.242l642 ---|          LDD    MA          WRITE INPUT REGISTER TO MESSAGE BUFFER
Line S00369 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05484  M01S00369.242l642 +++|          LDN    MX          DROP CHANNEL
05485  M01S00370.242l642 +++|          DCHAN
05486  M01S00371.242l642 +++|          LDD    EQ          SAVE RECALL STATUS INFORMATION
05487  M01S00372.242l642 +++|          SHN    2
05488  M01S00373.242l642 +++|          LMD    PN
05489  M01S00374.242l642 +++|          STD    IR+2
05490  M01S00375.242l642 +++|          LDM    SFMX
05491  M01S00376.242l642 +++|          ZJN    RCL1        IF PORT NOT ATTACHED
05492  M01S00377.242l642 +++|          LDD    IR+2
05493  M01S00378.242l642 +++|          LMN    2
05494  M01S00379.242l642 +++|          STD    IR+2
05495  M01S00380.242l642 +++| RCL1     LDD    MA          WRITE INPUT REGISTER TO MESSAGE BUFFER
05496  M00S04879.1tm     +++|          CWD    IR
05497  M00S04880.1tm     +++|          LDN    ZERL        CLEAR REQUEST PARAMETERS
05498  M00S04881.1tm     +++|          CRD    CM
Line S04882 Modification History
M01 (Removed by) 1tm2
Seq #  *Modification Id* Act 
----------------------------+
05499  M01S04882.1tm2    ---|          LDK    PTRF        SET TIMED RECALL REQUEST
Line S00001 Modification History
M01 (Added by) 1tm2
Seq #  *Modification Id* Act 
----------------------------+
05500  M01S00001.1tm2    +++|          LDK    PTMF        SET TIMED RECALL REQUEST
05501  M00S04883.1tm     +++|          STD    CM+1
05502  M00S04884.1tm     +++|          LDC    RCLDLY*1000D  SET RECALL DELAY (MILLISECONDS)
05503  M00S04885.1tm     +++|          STD    CM+4
05504  M00S04886.1tm     +++|          SHN    -14
05505  M00S04887.1tm     +++|          STD    CM+3
05506  M00S04888.1tm     +++|          MONITOR RECM       REQUEST PPU RECALL
05507  M00S04889.1tm     +++|          JMP    PPR         EXIT TO PPU RESIDENT
05508  M00S04890.1tm     +++| RLT      SPACE  4,15
05509  M00S04891.1tm     +++|**        RLT - READ LINK TABLE.
05510  M00S04892.1tm     +++|*
05511  M00S04893.1tm     +++|*         READS THE POT LINK TABLE.
05512  M00S04894.1tm     +++|*
05513  M00S04895.1tm     +++|*         ENTRY  (DP+1) = POT POINTER IN LINK TABLE.
05514  M00S04896.1tm     +++|*
05515  M00S04897.1tm     +++|*         EXIT   (A) = NEXT POT.
05516  M00S04898.1tm     +++|*
05517  M00S04899.1tm     +++|*         USES   T0 - T5.
05518  M00S04900.1tm     +++|*
05519  M00S04901.1tm     +++|*         MACROS ADCPL.
05520  M00S04902.1tm     +++|
05521  M00S04903.1tm     +++|
05522  M00S04904.1tm     +++| RLT      SUBR               ENTRY/EXIT
05523  M00S04905.1tm     +++|          LDD    DP+1        SET BYTE NUMBER
05524  M00S04906.1tm     +++|          LPN    3
05525  M00S04907.1tm     +++|          STD    T5
05526  M00S04908.1tm     +++|          LDD    DP+1        READ LINK WORD
05527  M00S04909.1tm     +++|          SHN    -2
05528  M00S04910.1tm     +++|          ADCPL
05529  M00S04911.1tm     +++|          CRD    T0
05530  M00S04912.1tm     +++|          LDI    T5          RETURN WITH NEXT LINK
05531  M00S04913.1tm     +++|          UJN    RLTX
05532  M00S04914.1tm     +++| SAT      SPACE  4,15
05533  M00S04915.1tm     +++|**        SAT - SET ACTIVITY TIME.
05534  M00S04916.1tm     +++|*
05535  M00S04917.1tm     +++|*         SETS THE LOWER 12 BITS OF THE REAL-TIME SECONDS
05536  M00S04918.1tm     +++|*         CLOCK INTO (IR+3).
05537  M00S04919.1tm     +++|*
05538  M00S04920.1tm     +++|*         EXIT   (IR+3) = CURRENT REAL-TIME SECONDS.
05539  M00S04921.1tm     +++|*
05540  M00S04922.1tm     +++|*         USES   CM - CM+4.
05541  M00S04923.1tm     +++|
05542  M00S04924.1tm     +++|
05543  M00S04925.1tm     +++| SAT      SUBR               ENTRY/EXIT
05544  M00S04926.1tm     +++|          LDK    RTCL        READ REAL-TIME CLOCK
05545  M00S04927.1tm     +++|          CRD    CM
05546  M00S04928.1tm     +++|          LDD    CM+1        SET SECONDS
05547  M00S04929.1tm     +++|          STD    IR+3
05548  M00S04930.1tm     +++|          UJN    SATX        RETURN
05549  M00S04931.1tm     +++| SDS      SPACE  4,15
05550  M00S04932.1tm     +++|**        SDS - SIGNAL DRIVER SHUTDOWN.
05551  M00S04933.1tm     +++|*
05552  M00S04934.1tm     +++|*         SIGNALS DRIVER SHUTDOWN BY SETTING THE DRIVER
05553  M00S04935.1tm     +++|*         SHUTDOWN FLAG IN THE DRIVER CONTROL WORD.
05554  M00S04936.1tm     +++|*
05555  M00S04937.1tm     +++|*         EXIT   DRIVER SHUTDOWN FLAG SET IN DRIVER
05556  M00S04938.1tm     +++|*                CONTROL WORD.
05557  M00S04939.1tm     +++|*
05558  M00S04940.1tm     +++|*         USES   CM - CM+4.
05559  M00S04941.1tm     +++|*
05560  M00S04942.1tm     +++|*         CALLS  CWA.
05561  M00S04943.1tm     +++|
05562  M00S04944.1tm     +++|
05563  M00S04945.1tm     +++| SDS      SUBR               ENTRY/EXIT
05564  M00S04946.1tm     +++|          RJM    CWA         SET DRIVER CONTROL WORD ADDRESS
05565  M00S04947.1tm     +++|          CRD    CM          READ DRIVER CONTROL WORD
05566  M00S04948.1tm     +++|          LDD    CM          CHECK SHUTDOWN FLAG
05567  M00S04949.1tm     +++|          NJN    SDSX        IF DRIVER SHUTDOWN ALREADY SET, RETURN
05568  M00S04950.1tm     +++|          LDN    1           SET DRIVER SHUTDOWN FLAG
05569  M00S04951.1tm     +++|          STD    CM
05570  M00S04952.1tm     +++|          RJM    CWA         REWRITE DRIVER CONTROL WORD
05571  M00S04953.1tm     +++|          CWD    CM
05572  M00S04954.1tm     +++|          UJN    SDSX        RETURN
05573  M00S04955.1tm     +++| SEM      SPACE  4,15
05574  M00S04956.1tm     +++|**        SEM - SET EXTENDED MODE.
05575  M00S04957.1tm     +++|*
05576  M00S04958.1tm     +++|*         SETS THE EXTENDED *ASCII* MODE BIT IN DP+3.
05577  M00S04959.1tm     +++|*
05578  M00S04960.1tm     +++|*         EXIT   (DP+3) = EXTENDED (*ASCII*) MODE SET.
05579  M00S04961.1tm     +++|
05580  M00S04962.1tm     +++|
05581  M00S04963.1tm     +++| SEM      SUBR               ENTRY/EXIT
05582  M00S04964.1tm     +++|          LDD    DP+3        SET *ASCII* MODE
05583  M00S04965.1tm     +++|          SCN    2
05584  M00S04966.1tm     +++|          LMN    2
05585  M00S04967.1tm     +++|          STD    DP+3
05586  M00S04968.1tm     +++|          UJN    SEMX        RETURN
05587  M00S04969.1tm     +++| STA      SPACE  4,15
05588  M00S04970.1tm     +++|**        STA - SET TERMINAL TABLE ADDRESS.
05589  M00S04971.1tm     +++|*
05590  M00S04972.1tm     +++|*         SETS THE ABSOLUTE CM FWA OF TERMINAL TABLE.
05591  M00S04973.1tm     +++|*
05592  M00S04974.1tm     +++|*         ENTRY  (TN) = TERMINAL NUMBER.
05593  M00S04975.1tm     +++|*
05594  M00S04976.1tm     +++|*         EXIT   (A) = ABSOLUTE FWA OF TERMINAL TABLE.
05595  M00S04977.1tm     +++|*
05596  M00S04978.1tm     +++|*         MACROS TTADD.
05597  M00S04979.1tm     +++|
05598  M00S04980.1tm     +++|
05599  M00S04981.1tm     +++| STA      SUBR               ENTRY/EXIT
05600  M00S04982.1tm     +++|          TTADD  0           SET FWA OF TERMINAL TABLE
05601  M00S04983.1tm     +++|          UJN    STAX        RETURN
Line S00103 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05602  M01S00103.ns2149  +++| SVM      SPACE  4,15
05603  M01S00104.ns2149  +++|**        SVM - SERVICE MULTIPLEXER.
05604  M01S00105.ns2149  +++|*
05605  M01S00106.ns2149  +++|*         PERFORMS DATA OUTPUT AND INPUT OPERATIONS ON THE
05606  M01S00107.ns2149  +++|*         TWO-PORT MULTIPLEXER.
05607  M01S00108.ns2149  +++|*
05608  M01S00109.ns2149  +++|*         ENTRY  (DO) = OUTPUT DATA IF BIT 2**11 SET.
05609  M01S00110.ns2149  +++|*
05610  M01S00111.ns2149  +++|*         EXIT   (DO) = ZERO IF DATA SENT.
05611  M01S00112.ns2149  +++|*                     = OUTPUT DATA IF OUTPUT BUFFER FULL.
05612  M01S00113.ns2149  +++|*                (DI) = INPUT DATA.
05613  M01S00114.ns2149  +++|*                     = ZERO IF NO INPUT DATA.
05614  M01S00115.ns2149  +++|*
05615  M01S00116.ns2149  +++|*         CALLS  IFN, RMA, SPA.
05616  M01S00117.ns2149  +++|
05617  M01S00118.ns2149  +++|
Line S00119 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05618  M02S00119.242l642 ---| SVM3     RJM    RMA         RELEASE MULTIPLEXER ACCESS
Line S00381 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05619  M01S00381.242l642 +++| SVM4     LDN    0
05620  M01S00382.242l642 +++|          STM    SVMA
05621  M01S00383.242l642 +++| SVM5     RJM    RMA         RELEASE MULTIPLEXER ACCESS
Line S00120 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05622  M01S00120.ns2149  +++|
05623  M01S00121.ns2149  +++| SVM      SUBR               ENTRY/EXIT
05624  M01S00122.ns2149  +++|          LDN    0           CLEAR INPUT DATA
05625  M01S00123.ns2149  +++|          STD    DI
Line S00384 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05626  M01S00384.242l642 +++|          LDM    SFMX
05627  M01S00385.242l642 +++|          ZJN    SVMX        IF PORT NOT SELECTED
Line S00124 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05628  M01S00124.ns2149  +++|          RJM    SPA         START PORT ACCESS
05629  M01S00125.ns2149  +++|          LPN    6           CHECK *CARRIER ON* AND *DATA SET READY*
05630  M01S00126.ns2149  +++|          LMN    6
Line S00127 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05631  M02S00127.242l642 ---|          NJN    SVM3        IF NOT *CARRIER ON* AND *DATA SET READY*
Line S00386 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05632  M01S00386.242l642 +++|          NJN    SVM5        IF NOT *CARRIER ON* AND *DATA SET READY*
Line S00128 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05633  M01S00128.ns2149  +++|
05634  M01S00129.ns2149  +++|*         WRITE OUTPUT DATA TO MULTIPLEXER PORT.
05635  M01S00130.ns2149  +++|
05636  M01S00131.ns2149  +++|          LDM    SSMX        GET PORT STATUS
05637  M01S00132.ns2149  +++|          LPN    20
05638  M01S00133.ns2149  +++|          ZJN    SVM1        IF NOT *OUTPUT BUFFER READY*
05639  M01S00134.ns2149  +++|          LDD    DO          CHECK OUTPUT DATA
05640  M01S00135.ns2149  +++|          SHN    21-13
05641  M01S00136.ns2149  +++|          PJN    SVM1        IF NO OUTPUT DATA
05642  M01S00137.ns2149  +++|          LDC    MXWT        SELECT *WRITE* FUNCTION
05643  M01S00138.ns2149  +++|          RJM    IFN
05644  M01S00139.ns2149  +++|          LDD    DO          TRANSMIT DATA TO PORT
05645  M01S00140.ns2149  +++|          LPC    377
05646  M01S00141.ns2149  +++|          ACN    MX
05647  M01S00142.ns2149  +++|          OAN    MX
05648  M01S00143.ns2149  +++|          DCN    MX+40
05649  M01S00144.ns2149  +++|          LDN    0           CLEAR OUTPUT DATA POINTER
05650  M01S00145.ns2149  +++|          STD    DO
05651  M01S00146.ns2149  +++|
05652  M01S00147.ns2149  +++|*         READ INPUT DATA FROM MULTIPLEXER PORT.
05653  M01S00148.ns2149  +++|
Line S00149 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05654  M02S00149.242l642 ---| SVM1     LDM    SSMX        CHECK PORT STATUS
Line S00387 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05655  M01S00387.242l642 +++| SVM1     LDC    **
05656  M01S00388.242l642 +++| SVMA     EQU    *-1
05657  M01S00389.242l642 +++|          ZJN    SVM2        IF NO PREVIOUS CHARACTER
05658  M01S00390.242l642 +++|          STD    DI          RETURN PREVIOUS CHARACTER
05659  M01S00391.242l642 +++|          UJP    SVM4        RELEASE MULTIPLEXER ACCESS
05660  M01S00392.242l642 +++|
05661  M01S00393.242l642 +++| SVM2     LDM    SSMX        CHECK PORT STATUS
Line S00150 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05662  M01S00150.ns2149  +++|          LPN    10
Line S00151 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05663  M02S00151.242l642 ---|          ZJN    SVM2        IF NOT *INPUT DATA READY*
05664  M02S00152.242l642 ---|          LDC    MXRD        SELECT *READ* FUNCTION
Line S00394 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05665  M01S00394.242l642 +++|          ZJN    SVM3        IF NOT *INPUT DATA READY*
05666  M01S00395.242l642 +++|          LDD    HN          SELECT *READ* FUNCTION
05667  M01S00396.242l642 +++|          ERRNZ  MXRD-100    *MXRD* CHANGED
Line S00153 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05668  M01S00153.ns2149  +++|          RJM    IFN
05669  M01S00154.ns2149  +++|          ACN    MX
05670  M01S00155.ns2149  +++|          IAN    MX          INPUT DATA FROM PORT
05671  M01S00156.ns2149  +++|          DCN    MX+40
Line S00157 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05672  M02S00157.242l642 ---| SVM2     STD    DI          STORE INPUT DATA
05673  M02S00158.242l642 ---|          UJP    SVM3        RELEASE MULTIPLEXER ACCESS
Line S00397 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05674  M01S00397.242l642 +++| SVM3     STD    DI          STORE INPUT DATA
05675  M01S00398.242l642 +++|          UJP    SVM5        RELEASE MULTIPLEXER ACCESS
05676  M00S04984.1tm     +++| SWA      SPACE  4,15
05677  M00S04985.1tm     +++|**        SWA - SET WORD ADDRESS.
05678  M00S04986.1tm     +++|*
05679  M00S04987.1tm     +++|*         SET ADDRESS OF CURRENT WORD OF CURRENT POT.
05680  M00S04988.1tm     +++|*
05681  M00S04989.1tm     +++|*         ENTRY  (DP+1) = CURRENT POT.
05682  M00S04990.1tm     +++|*                (DP+2) = WORD POINTER.
05683  M00S04991.1tm     +++|*
05684  M00S04992.1tm     +++|*         EXIT   (A) = CM ADDRESS OF CURRENT WORD (ABSOLUTE).
05685  M00S04993.1tm     +++|*
05686  M00S04994.1tm     +++|*         MACROS ADCBM.
05687  M00S04995.1tm     +++|
05688  M00S04996.1tm     +++|
05689  M00S04997.1tm     +++| SWA      SUBR               ENTRY/EXIT
05690  M00S04998.1tm     +++|          LDD    DP+2        SET WORD
05691  M00S04999.1tm     +++|          LPC    160
05692  M00S05000.1tm     +++|          SHN    21-6
05693  M00S05001.1tm     +++|          LMD    DP+1        SET POT POINTER
05694  M00S05002.1tm     +++|          SHN    3           TIMES 10B
05695  M00S05003.1tm     +++|          ADCBM              ADD POT BUFFER ADDRESS
05696  M00S05004.1tm     +++|          UJN    SWAX
05697  M00S05005.1tm     +++| WDC      SPACE  4,15
05698  M00S05006.1tm     +++|**        WDC - WRITE TERMINAL TABLE WORD *VDCT*.
05699  M00S05007.1tm     +++|*
05700  M00S05008.1tm     +++|*         WRITES TERMINAL TABLE WORD *VDCT* TO CENTRAL MEMORY.
05701  M00S05009.1tm     +++|*
05702  M00S05010.1tm     +++|*         ENTRY  (DC - DC+4) = TERMINAL TABLE WORD *VDCT*.
Line S00038 Modification History
M01 (Added by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
05703  M01S00038.v23l617 +++|*
05704  M01S00039.v23l617 +++|*         EXIT   (A) = ADDRESS OF *VDCT* WORD.
05705  M00S05011.1tm     +++|*
05706  M00S05012.1tm     +++|*         CALLS  STA.
05707  M00S05013.1tm     +++|
05708  M00S05014.1tm     +++|
05709  M00S05015.1tm     +++| WDC      SUBR               ENTRY/EXIT
05710  M00S05016.1tm     +++|          RJM    STA         SET FWA OF TERMINAL TABLE
05711  M00S05017.1tm     +++|          ADN    VDCT        WRITE *VDCT* TO CM
05712  M00S05018.1tm     +++|          CWD    DC
05713  M00S05019.1tm     +++|          UJN    WDCX        RETURN
Line S00159 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05714  M01S00159.ns2149  +++|          SPACE  4,10
05715  M01S00160.ns2149  +++|**        COMMON DECKS
05716  M01S00161.ns2149  +++|
Line S00399 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05717  M01S00399.242l642 +++| MRA$     EQU    0
Line S00162 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05718  M01S00162.ns2149  +++|          LIST   X
05719  M01S00163.ns2149  +++| QUAL$    EQU    0
05720  M01S00164.ns2149  +++|*CALL     COMPMRA
05721  M01S00165.ns2149  +++|
05722  M01S00166.ns2149  +++| APA$     EQU    0
05723  M01S00167.ns2149  +++| PMA$     EQU    0
05724  M01S00168.ns2149  +++|*CALL     COMPTMA
05725  M01S00169.ns2149  +++|          LIST   -X
05726  M01S00170.ns2149  +++| OMBUF    SPACE  4,15
05727  M01S00171.ns2149  +++|**        OMBUF - OPERATOR MESSAGE BUFFER.
05728  M01S00172.ns2149  +++|
05729  M01S00173.ns2149  +++|
05730  M01S00174.ns2149  +++| OMBUF    BSS    0           OPERATOR MESSAGE BUFFER
05731  M01S00175.ns2149  +++|
05732  M01S00176.ns2149  +++| OVLA     EQU    OMBUF+OMBUFL+5  OVERLAY LOAD ADDRESS
05733  M01S00177.ns2149  +++| PRS      TITLE  DRIVER PRESET.
05734  M01S00178.ns2149  +++|          USE    PRESET
05735  M01S00179.ns2149  +++| PRS      SPACE  4,30
05736  M01S00180.ns2149  +++|**        PRS - PRESET DRIVER.
05737  M01S00181.ns2149  +++|*
Line S00182 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05738  M02S00182.242l642 ---|*         ENTRY  (IR+3) = REAL-TIME CLOCK (SECONDS) AT START
Line S00400 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05739  M01S00400.242l642 +++|*         ENTRY  (IR+2) = 0, IF NOT PP RECALL AND NOT *2TM* CALL.
05740  M01S00401.242l642 +++|*                       = 10/EQ, 1/S, 1/P, IF PP RECALL OR *2TM* CALL.
05741  M01S00402.242l642 +++|*                         EQ = RESERVED EQUIPMENT NUMBER.
05742  M01S00403.242l642 +++|*                         S = 1, IF PORT CURRENTLY IS RESERVED FOR
05743  M01S00404.242l642 +++|*                             *1TM*.
05744  M01S00405.242l642 +++|*                         P = PORT NUMBER.
05745  M01S00406.242l642 +++|*                (IR+3) = REAL-TIME CLOCK (SECONDS) AT START
Line S00183 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05746  M01S00183.ns2149  +++|*                         OF DRIVER INACTIVITY TIME-OUT.
05747  M01S00184.ns2149  +++|*                       = ZERO ON INITIAL CALL OR EXECUTIVE RECALL.
05748  M01S00185.ns2149  +++|*                (IR+4) = DRIVER CONTROL WORD POINTER.
05749  M01S00186.ns2149  +++|*                (DRIVER CONTROL WORD) INITIAL CALL =
05750  M01S00187.ns2149  +++|*                     12/0, 6/0, 18/DRN, 24/0
05751  M01S00188.ns2149  +++|*                        DRN = DRIVER NAME.
05752  M01S00189.ns2149  +++|*                (DRIVER CONTROL WORD) PP OR EXECUTIVE RECALL =
05753  M01S00190.ns2149  +++|*                     12/3, 24/CSA, 12/TC, 12/TN
05754  M01S00191.ns2149  +++|*                        CSA = CIRCULAR STACK ADDRESS.
05755  M01S00192.ns2149  +++|*                        TC  = TERMINAL COUNT.
05756  M01S00193.ns2149  +++|*                        TN  = DRIVER TERMINAL NUMBER.
05757  M01S00194.ns2149  +++|*
05758  M01S00195.ns2149  +++|*         EXIT   TO *ITM*, DRIVER CONTROL LOOP -
05759  M01S00196.ns2149  +++|*                  CHANNEL AND EQUIPMENT RESERVED.
Line S00197 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05760  M02S00197.242l642 ---|*                  MULTIPLEXER AND PORT SELECTED.
Line S00198 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05761  M01S00198.ns2149  +++|*                  (EQ) = EST ORDINAL + 2**9.
05762  M01S00199.ns2149  +++|*                  (LF) = NONZERO FOR INITIAL CONNECTION ATTEMPT.
05763  M01S00200.ns2149  +++|*                  (PN) = MULTIPLEXER PORT NUMBER - 0 OR 1.
05764  M01S00201.ns2149  +++|*                  (IR+3) = CURRENT REAL-TIME CLOCK (SECONDS)
05765  M01S00202.ns2149  +++|*                           IF INITIAL CALL OR EXECUTIVE RECALL.
05766  M01S00203.ns2149  +++|*                         = INPUT REGISTER CONTENTS IF PP RECALL.
05767  M01S00204.ns2149  +++|*                  (OMCC) = 0.
Line S00407 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05768  M01S00407.242l642 +++|*                  (SF7D) = 0.
Line S00205 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05769  M01S00205.ns2149  +++|*                  TRANSLATION TABLES MODIFIED IF SYSTEM IS IN
05770  M01S00206.ns2149  +++|*                  63 CHARACTER SET MODE.
Line S00207 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05771  M02S00207.242l642 ---|*                TO *MRER* IF NO TPM AVAILABLE.
Line S00040 Modification History
M01 (Added by) v23l617
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05772  M02S00040.242l642 ---|*                TO *PUER* IF ON SAME PORT AS *SCD*.
Line S00208 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05773  M01S00208.ns2149  +++|*
Line S00209 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05774  M02S00209.242l642 ---|*         CALLS  CEF, CEQ, CWA, INI, RCE, SAD, SAT, SEL, STA.
Line S00408 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05775  M01S00408.242l642 +++|*         CALLS  CEF, CWA, PMA, SAD, SAT, SPN, STA.
Line S00210 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05776  M01S00210.ns2149  +++|*
Line S00211 Modification History
M01 (Added by) ns2149
M02 (Removed by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
05777  M02S00211.v23l617 ---|*         MACROS LDCDQ.
Line S00041 Modification History
M01 (Added by) v23l617
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05778  M02S00041.242l642 ---|*         MACROS LDCDQ, SFA.
Line S00409 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05779  M01S00409.242l642 +++|*         MACROS EXECUTE, LDCDQ, RCHAN.
Line S00212 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
05780  M01S00212.ns2149  +++|
05781  M01S00213.ns2149  +++|
05782  M01S00214.ns2149  +++| PRS      BSS    0           ENTRY
Line S00410 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05783  M01S00410.242l642 +++|          RJM    PMA         PRESET MULTIPLEXER ACCESS
05784  M01S00411.242l642 +++|          LDD    IR+2
05785  M01S00412.242l642 +++|          NJN    PRS1        IF RECALL
05786  M01S00413.242l642 +++|          EXECUTE  2TM       PRESET NON-RECALL LOAD
Line S00215 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05787  M02S00215.242l642 ---|          LDN    0           CLEAR EQUIPMENT ASSIGNMENT
05788  M02S00216.242l642 ---|          STD    EQ
05789  M02S00217.242l642 ---|          RJM    CEF         CHECK ERROR FLAG
Line S00414 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05790  M01S00414.242l642 +++|
05791  M01S00415.242l642 +++|*         PRESET VALUES FROM RECALL.
05792  M01S00416.242l642 +++|
05793  M01S00417.242l642 +++| PRS1     LPN    1
05794  M01S00418.242l642 +++|          STD    PN          SET PORT NUMBER
05795  M01S00419.242l642 +++|          RJM    SPN
05796  M01S00420.242l642 +++|          STD    IT          CLEAR INTERVAL TIMER
05797  M01S00421.242l642 +++|          LDD    IR+2
05798  M01S00422.242l642 +++|          LPN    2
05799  M01S00423.242l642 +++|          ZJN    PRS2        IF PORT WAS NOT SELECTED
05800  M01S00424.242l642 +++|          LDD    PN
05801  M01S00425.242l642 +++|          ADC    MXPT
05802  M01S00426.242l642 +++|          STM    SFMX
05803  M01S00427.242l642 +++| PRS2     LDD    IR+2        RESTORE EQUIPMENT NUMBER
05804  M01S00428.242l642 +++|          SHN    -2
05805  M01S00429.242l642 +++|          STD    EQ
05806  M01S00430.242l642 +++|          LDN    MX          REQUEST CHANNEL
05807  M01S00431.242l642 +++|          RCHAN
05808  M01S00432.242l642 +++|          LDN    2           SET PORT ACQUIRED BEFORE FLAG
05809  M01S00433.242l642 +++|          STM    STMC
05810  M01S00434.242l642 +++|          RJM    CEF         CHECK ERROR FLAG
05811  M01S00435.242l642 +++|          LDM    SFMX
05812  M01S00436.242l642 +++|          NJN    PRS3        IF PORT SELECTED
05813  M01S00437.242l642 +++|          LDC    /CTL/RPA    SET REENTRY ADDRESS TO REGAIN PORT
05814  M01S00438.242l642 +++|          STM    PRSA
05815  M01S00439.242l642 +++|          LDN    RPATIO      SET TIME-OUT
05816  M01S00440.242l642 +++|          STD    IT
05817  M01S00441.242l642 +++|
05818  M01S00442.242l642 +++|*         SET ABSOLUTE ADDRESSES AND SIGNAL INITIALIZATION COMPLETE.
05819  M01S00443.242l642 +++|
05820  M01S00444.242l642 +++| PRS3     RJM    SAD         SET ABSOLUTE CM ADDRESSES
05821  M01S00445.242l642 +++|          RJM    CWA         READ DRIVER CONTROL WORD
05822  M01S00446.242l642 +++|          CRD    DC
05823  M01S00447.242l642 +++|          LDD    DC+4
05824  M01S00448.242l642 +++|          STD    TN
05825  M01S00449.242l642 +++|          LDN    0           CLEAR INTERLOCK
05826  M01S00450.242l642 +++|          STD    DC
05827  M01S00451.242l642 +++|          RJM    CWA         REWRITE DRIVER CONTROL WORD
05828  M01S00452.242l642 +++|          CWD    DC
05829  M01S00453.242l642 +++|
05830  M01S00454.242l642 +++|*         PRESET TERMINAL ROUTINE ADDRESS.
05831  M01S00455.242l642 +++|
05832  M01S00456.242l642 +++|          LDN    ZERL        CLEAR *VDPT* IMAGE
05833  M01S00457.242l642 +++|          CRD    DP
05834  M01S00458.242l642 +++|          CRD    CH          CLEAR *VCHT* IMAGE
05835  M01S00459.242l642 +++|          LDC    /CTL/ONL    SET STARTING ADDRESS
05836  M01S00460.242l642 +++| PRSA     EQU    *-1
05837  M01S00461.242l642 +++|*         LDC    /CTL/RPA    (PP RECALL AND PORT NOT SELECTED)
05838  M01S00462.242l642 +++|          STD    DP+4
05839  M01S00463.242l642 +++|          RJM    STA         SET FWA OF TERMINAL TABLE
05840  M01S00464.242l642 +++|          ADN    VDPT        WRITE *VDPT*
05841  M01S00465.242l642 +++|          CWD    DP
05842  M01S00466.242l642 +++|          ADN    VCHT-VDPT   WRITE *VCHT*
05843  M01S00467.242l642 +++|          CWD    CH
05844  M01S00468.242l642 +++|
05845  M01S00469.242l642 +++|*         INITIALIZE MISCELLANEOUS POINTERS.
05846  M01S00470.242l642 +++|
05847  M01S00471.242l642 +++|          LDN    0           CLEAR INPUT AND OUTPUT DATA
05848  M01S00472.242l642 +++|          STD    DI
05849  M01S00473.242l642 +++|          STD    DO
05850  M01S00474.242l642 +++|          STD    F7          CLEAR START OF *F7* SEQUENCE DETECTED
05851  M01S00475.242l642 +++|          STD    HS          CLEAR HALF-SECOND FLAG
05852  M01S00476.242l642 +++|          STD    PY          CLEAR ODD PARITY
05853  M01S00477.242l642 +++|          STM    OMCC        CLEAR OPERATOR MESSAGE CHARACTER COUNT
05854  M01S00478.242l642 +++|          LDN    77
05855  M01S00479.242l642 +++|          STD    LF
05856  M01S00480.242l642 +++|          LDCDQ  2           SET CIRCULAR QUEUE *IN*
05857  M01S00481.242l642 +++|          CRD    IN
05858  M01S00482.242l642 +++|
05859  M01S00483.242l642 +++|*         SET TIME-OUT IF INITIAL CALL OR EXECUTIVE RECALL.
05860  M01S00484.242l642 +++|
05861  M01S00485.242l642 +++|          LDD    IR+3        CHECK TIME-OUT
05862  M01S00486.242l642 +++|          NJN    PRS4        IF DRIVER RECALL
05863  M01S00487.242l642 +++|          RJM    SAT         SET ACTIVITY TIME-OUT
05864  M01S00488.242l642 +++| PRS4     LJM    /CTL/ITM    ENTER DRIVER MAIN LOOP
05865  M01S00489.242l642 +++|          TITLE  DRIVER PRESET SUBROUTINES.
05866  M01S00490.242l642 +++| SAD      SPACE  4,15
05867  M01S00491.242l642 +++|**        SAD - SET ABSOLUTE ADDRESSES.
05868  M01S00492.242l642 +++|*
05869  M01S00493.242l642 +++|*         DETERMINES ABSOLUTE CM ADDRESS AND CALLS *SIA*
05870  M01S00494.242l642 +++|*         TO INSERT THEM INTO PP INSTRUCTIONS.
05871  M01S00495.242l642 +++|*
05872  M01S00496.242l642 +++|*         USES   T1, CM - CM+4.
05873  M01S00497.242l642 +++|*
05874  M01S00498.242l642 +++|*         CALLS  CWA, SIA.
05875  M01S00499.242l642 +++|
05876  M01S00500.242l642 +++|
05877  M01S00501.242l642 +++| SAD      SUBR               ENTRY/EXIT
05878  M01S00502.242l642 +++|
05879  M01S00503.242l642 +++|*         SET BUFFER MEMORY ADDRESS REFERENCES.
05880  M01S00504.242l642 +++|
05881  M01S00505.242l642 +++|          LDC    TBMA        SET INSTRUCTION ADDRESS TABLE POINTER
05882  M01S00506.242l642 +++|          STD    T1
05883  M01S00507.242l642 +++|          LDD    RA          READ BUFFER MEMORY POINTER
05884  M01S00508.242l642 +++|          SHN    6
05885  M01S00509.242l642 +++|          ADK    VBMP
05886  M01S00510.242l642 +++|          CRD    CM
05887  M01S00511.242l642 +++|          LDN    CM+3        SET FWA BUFFER MEMORY
05888  M01S00512.242l642 +++|          RJM    SIA         SET INSTRUCTION ADDRESSES
05889  M01S00513.242l642 +++|
05890  M01S00514.242l642 +++|*         SET DRIVER REQUEST QUEUE REFERENCES.
05891  M01S00515.242l642 +++|
05892  M01S00516.242l642 +++|          LDC    TDQA        SET INSTRUCTION ADDRESS TABLE POINTER
05893  M01S00517.242l642 +++|          STD    T1
05894  M01S00518.242l642 +++|          RJM    CWA         READ DRIVER CONTROL WORD
05895  M01S00519.242l642 +++|          CRD    CM
05896  M01S00520.242l642 +++|          LDN    CM+1        SET FWA DRIVER REQUEST QUEUE
05897  M01S00521.242l642 +++|          RJM    SIA         SET INSTRUCTION ADDRESSES
05898  M01S00522.242l642 +++|
05899  M01S00523.242l642 +++|*         SET POT LINK TABLE REFERENCES.
05900  M01S00524.242l642 +++|
05901  M01S00525.242l642 +++|          LDC    TPLA        SET INSTRUCTION ADDRESS TABLE POINTER
05902  M01S00526.242l642 +++|          STD    T1
05903  M01S00527.242l642 +++|          LDD    RA          READ POT LINK TABLE POINTER
05904  M01S00528.242l642 +++|          SHN    6
05905  M01S00529.242l642 +++|          ADK    VPLP
05906  M01S00530.242l642 +++|          CRD    CM
05907  M01S00531.242l642 +++|          LDN    CM+1        SET FWA POT LINK TABLE
05908  M01S00532.242l642 +++|          RJM    SIA         SET INSTRUCTION ADDRESSES
05909  M01S00533.242l642 +++|
05910  M01S00534.242l642 +++|
05911  M01S00535.242l642 +++|*         SET TERMINAL TABLE REFERENCES.
05912  M01S00536.242l642 +++|
05913  M01S00537.242l642 +++|          LDC    TTTA        SET INSTRUCTION ADDRESS TABLE POINTER
05914  M01S00538.242l642 +++|          STD    T1
05915  M01S00539.242l642 +++|          LDD    RA          READ TERMINAL TABLE ADDRESS POINTER
05916  M01S00540.242l642 +++|          SHN    6
05917  M01S00541.242l642 +++|          ADK    VTTP
05918  M01S00542.242l642 +++|          CRD    CM
05919  M01S00543.242l642 +++|          LDN    CM+1        SET FWA OF TERMINAL TABLES
05920  M01S00544.242l642 +++|          RJM    SIA         SET INSTRUCTION ADDRESSES
05921  M01S00545.242l642 +++|          UJP    SADX        RETURN
05922  M01S00546.242l642 +++| SIA      SPACE  4,15
05923  M01S00547.242l642 +++|**        SIA - SET INSTRUCTION ADDRESSES.
05924  M01S00548.242l642 +++|*
05925  M01S00549.242l642 +++|*         SETS ABSOLUTE ADDRESSES IN INSTRUCTION ADDRESS
05926  M01S00550.242l642 +++|*         FIELDS.
05927  M01S00551.242l642 +++|*
05928  M01S00552.242l642 +++|*         ENTRY  (T1) = ADDRESS OF TABLE OF INSTRUCTION
05929  M01S00553.242l642 +++|*                       ADDRESSES.
05930  M01S00554.242l642 +++|*                (A) = ADDRESS IN PP OF CM ADDRESS.
05931  M01S00555.242l642 +++|*
05932  M01S00556.242l642 +++|*         USES   T2, T6, T7.
05933  M01S00557.242l642 +++|
05934  M01S00558.242l642 +++|
05935  M01S00559.242l642 +++| SIA      SUBR               ENTRY/EXIT
05936  M01S00560.242l642 +++|          STD    T2          SAVE ADDRESS POINTER
05937  M01S00561.242l642 +++|          LDI    T2          GET ABSOLUTE ADDRESS
05938  M01S00562.242l642 +++|          SHN    6           ABSOLUTE RELATIVE ADDRESS
05939  M01S00563.242l642 +++|          ADD    RA
05940  M01S00564.242l642 +++|          SHN    6
05941  M01S00565.242l642 +++|          ADM    1,T2
05942  M01S00566.242l642 +++|          STD    T7          SAVE LOWER 12 BITS
05943  M01S00567.242l642 +++|          SHN    -14
05944  M01S00568.242l642 +++|          STD    T6
05945  M01S00569.242l642 +++|
05946  M01S00570.242l642 +++| SIA1     LDI    T1          READ INSTRUCTION ADDRESS
05947  M01S00571.242l642 +++|          ZJP    SIAX        IF END OF ADDRESS TABLE
05948  M01S00572.242l642 +++|          STD    T2
05949  M01S00573.242l642 +++|          LDD    T7          SET LOWER 12 BITS
05950  M01S00574.242l642 +++|          RAM    1,T2
05951  M01S00575.242l642 +++|          SHN    -14
05952  M01S00576.242l642 +++|          ADD    T6          ADD OVERFLOW
05953  M01S00577.242l642 +++|          RAI    T2          SET UPPER 6 BITS
05954  M01S00578.242l642 +++|          AOD    T1          ADVANCE TABLE INDEX
05955  M01S00579.242l642 +++|          UJN    SIA1        LOOP TO END OF TABLE
05956  M01S00580.242l642 +++|          SPACE  4,10
05957  M01S00581.242l642 +++|          QUAL
05958  M01S00582.242l642 +++| PMA      HERE
05959  M01S00583.242l642 +++| ITM      TITLE  INITIALIZATION TABLES.
05960  M01S00584.242l642 +++| ITM      SPACE  4,15
05961  M01S00585.242l642 +++|**        TABLES OF CENTRAL MEMORY REFERENCE INSTRUCTION
05962  M01S00586.242l642 +++|*         ADDRESSES.
05963  M01S00587.242l642 +++|
05964  M01S00588.242l642 +++|
05965  M01S00589.242l642 +++| TBMA     BSS    0           BUFFER MEMORY REFERENCES
05966  M01S00590.242l642 +++| TBMA     HERE
05967  M01S00591.242l642 +++|          CON    0
05968  M01S00592.242l642 +++|
05969  M01S00593.242l642 +++| TDQA     BSS    0           DRIVER REQUEST QUEUE REFERENCES
05970  M01S00594.242l642 +++| TDQA     HERE
05971  M01S00595.242l642 +++|          CON    0
05972  M01S00596.242l642 +++|
05973  M01S00597.242l642 +++| TPLA     BSS    0           POT LINK TABLE REFERENCES
05974  M01S00598.242l642 +++| TPLA     HERE
05975  M01S00599.242l642 +++|          CON    0
05976  M01S00600.242l642 +++|
05977  M01S00601.242l642 +++| TTTA     BSS    0           TERMINAL TABLE REFERENCES
05978  M01S00602.242l642 +++| TTTA     HERE
05979  M01S00603.242l642 +++|          CON    0
05980  M01S00604.242l642 +++|          SPACE  4,10
05981  M01S00605.242l642 +++|          USE    *
05982  M01S00606.242l642 +++|          QUAL
05983  M01S00607.242l642 +++|
05984  M01S00608.242l642 +++|          OVERFLOW
05985  M01S00609.242l642 +++|          TTL    1TM/2TM - NON-PP RECALL PRESET.
05986  M01S00610.242l642 +++|          TITLE  INITIAL DRIVER PRESET.
05987  M01S00611.242l642 +++|          IDENT  2TM,PREX
05988  M01S00612.242l642 +++|*COMMENT  1TM - PRESET.
Line S00613 Modification History
M01 (Added by) 242l642
M02 (Removed by) 281l803
Seq #  *Modification Id* Act 
----------------------------+
05989  M02S00613.281l803 ---|          COMMENT  COPYRIGHT CONTROL DATA CORPORATION, 1985.
Line S00002 Modification History
M01 (Added by) 281l803
Seq #  *Modification Id* Act 
----------------------------+
05990  M01S00002.281l803 +++|          COMMENT  COPYRIGHT CONTROL DATA SYSTEMS INC.  1992.
Line S00614 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
05991  M01S00614.242l642 +++| 2TM      SPACE  4,10
05992  M01S00615.242l642 +++|***       INITIAL DRIVER PRESET.
05993  M01S00616.242l642 +++|          SPACE  4,10
05994  M01S00617.242l642 +++|          ORG    PPFW
05995  M01S00618.242l642 +++|          QUAL   PRE
05996  M01S00619.242l642 +++| PRE      SPACE  4,30
05997  M01S00620.242l642 +++|**        PRE - PRESET DRIVER.
05998  M01S00621.242l642 +++|*
05999  M01S00622.242l642 +++|*                (IR+3) = REAL-TIME CLOCK (SECONDS) AT START
06000  M01S00623.242l642 +++|*                         OF DRIVER INACTIVITY TIME-OUT.
06001  M01S00624.242l642 +++|*                       = ZERO ON INITIAL CALL OR EXECUTIVE RECALL.
06002  M01S00625.242l642 +++|*                (IR+4) = DRIVER CONTROL WORD POINTER.
06003  M01S00626.242l642 +++|*                (DRIVER CONTROL WORD) INITIAL CALL =
06004  M01S00627.242l642 +++|*                     12/0, 6/0, 18/DRN, 24/0
06005  M01S00628.242l642 +++|*                        DRN = DRIVER NAME.
06006  M01S00629.242l642 +++|*                (DRIVER CONTROL WORD) PP OR EXECUTIVE RECALL =
06007  M01S00630.242l642 +++|*                     12/3, 24/CSA, 12/TC, 12/TN
06008  M01S00631.242l642 +++|*                        CSA = CIRCULAR STACK ADDRESS.
06009  M01S00632.242l642 +++|*                        TC  = TERMINAL COUNT.
06010  M01S00633.242l642 +++|*                        TN  = DRIVER TERMINAL NUMBER.
06011  M01S00634.242l642 +++|*
06012  M01S00635.242l642 +++|*         EXIT   TO *ITM*, PRESET -
06013  M01S00636.242l642 +++|*                  EQUIPMENT RESERVED.
06014  M01S00637.242l642 +++|*                  MULTIPLEXER AND PORT SELECTED.
06015  M01S00638.242l642 +++|*                (IR+2) = 10/EQ, 1/S, 1/P.
06016  M01S00639.242l642 +++|*                         EQ = RESERVED EQUIPMENT NUMBER.
06017  M01S00640.242l642 +++|*                         S = 1, IF PORT CURRENTLY IS RESERVED FOR
06018  M01S00641.242l642 +++|*                             *1TM*.
06019  M01S00642.242l642 +++|*                         P = PORT NUMBER.
06020  M01S00643.242l642 +++|*                  (IR+3) = CURRENT REAL-TIME CLOCK (SECONDS)
06021  M01S00644.242l642 +++|*                           IF INITIAL CALL OR EXECUTIVE RECALL.
06022  M01S00645.242l642 +++|*                         = INPUT REGISTER CONTENTS IF PP RECALL.
06023  M01S00646.242l642 +++|*                TO *MRER* IF NO TPM AVAILABLE.
06024  M01S00647.242l642 +++|*
06025  M01S00648.242l642 +++|*         CALLS  CEF, CEQ, CWA, INI, RCE, SEL.
06026  M01S00649.242l642 +++|*
06027  M01S00650.242l642 +++|*         MACROS EXECUTE, LDCDQ.
06028  M01S00651.242l642 +++|
06029  M01S00652.242l642 +++|
06030  M01S00653.242l642 +++| PRE      SUBR               ENTRY
06031  M01S00654.242l642 +++|          LDN    0
06032  M01S00655.242l642 +++|          STD    EQ
06033  M01S00656.242l642 +++|          RJM    CEF         CHECK ERROR FLAG
Line S00218 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06034  M01S00218.ns2149  +++|          RJM    CWA         SET DRIVER CONTROL WORD ADDRESS
06035  M01S00219.ns2149  +++|          CRD    DC          READ DRIVER CONTROL WORD
06036  M01S00220.ns2149  +++|
06037  M01S00221.ns2149  +++|*         PROCESS INITIAL DRIVER LOAD.
06038  M01S00222.ns2149  +++|
Line S00223 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06039  M02S00223.242l642 ---|          RJM    CEQ         CHECK EQUIPMENT
06040  M02S00224.242l642 ---|          LDD    DC+4        CHECK TERMINAL NUMBER
Line S00657 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06041  M01S00657.242l642 +++|          RJM    CEQ         CHECK EQUIPMENT
06042  M01S00658.242l642 +++|          LDD    DC+4        CHECK TERMINAL NUMBER
Line S00225 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06043  M01S00225.ns2149  +++|          STD    TN
Line S00226 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06044  M02S00226.242l642 ---|          NJN    PRS1        IF DEFINED - DRIVER RECALL
Line S00659 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06045  M01S00659.242l642 +++|          NJN    PRE1        IF DEFINED - DRIVER RECALL
Line S00227 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06046  M01S00227.ns2149  +++|          RJM    INI         PROCESS INITIAL DRIVER LOAD
06047  M01S00228.ns2149  +++|
06048  M01S00229.ns2149  +++|*         RESERVE TWO-PORT MULITPLEXER AND SELECT PORT.
06049  M01S00230.ns2149  +++|
Line S00231 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06050  M02S00231.242l642 ---| PRS1     LDD    EQ          CHECK IF EQUIPMENT AVAILABLE
06051  M02S00232.242l642 ---|          NJN    PRS2        IF EQUIPMENT AVAILABLE
Line S00660 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06052  M01S00660.242l642 +++| PRE1     LDD    EQ          CHECK IF EQUIPMENT AVAILABLE
06053  M01S00661.242l642 +++|          NJN    PRE2        IF EQUIPMENT AVAILABLE
Line S00233 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06054  M01S00233.ns2149  +++|          LJM    MRER        * 1TM - NO TPM AVAILABLE.*
06055  M01S00234.ns2149  +++|
Line S00235 Modification History
M01 (Added by) ns2149
M02 (Removed by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06056  M02S00235.v23l617 ---| PRS2     RJM    RCE         RESERVE CHANNEL AND EQUIPMENT
Line S00042 Modification History
M01 (Added by) v23l617
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06057  M02S00042.242l642 ---| PRS2     LDN    DSEQ        CHECK FOR PRESENCE OF *SCD* ON SAME PORT
06058  M02S00043.242l642 ---|          SFA    EST
06059  M02S00044.242l642 ---|          ADK    EQDE
06060  M02S00045.242l642 ---|          CRD    CM
06061  M02S00046.242l642 ---|          LDD    CM+2
06062  M02S00047.242l642 ---|          ZJN    PRS2.1      IF CC545 CONSOLE
06063  M02S00048.242l642 ---|          LDD    CM+4
06064  M02S00049.242l642 ---|          LMD    PN
06065  M02S00050.242l642 ---|          LPN    7
06066  M02S00051.242l642 ---|          NJN    PRS2.1      IF NOT ON SAME PORT
06067  M02S00052.242l642 ---|          LJM    PUER        PORT USAGE ERROR
06068  M02S00053.242l642 ---|
06069  M02S00054.242l642 ---| PRS2.1   RJM    RCE         RESERVE CHANNEL AND EQUIPMENT
Line S00662 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06070  M01S00662.242l642 +++| PRE2     RJM    CMF         CHECK RDF STATUS
06071  M01S00663.242l642 +++|          RJM    RCE         RESERVE CHANNEL AND EQUIPMENT
Line S00236 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06072  M01S00236.ns2149  +++|          RJM    SEL         SELECT MULTIPLEXER PORT
Line S00664 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06073  M01S00664.242l642 +++|
06074  M01S00665.242l642 +++|*         LOAD MAIN OVERLAY.
06075  M01S00666.242l642 +++|
06076  M01S00667.242l642 +++|          LDN    MX          RELEASE CHANNEL
06077  M01S00668.242l642 +++|          DCHAN
06078  M01S00669.242l642 +++|          LDD    EQ          SAVE RECALL STATUS INFORMATION
06079  M01S00670.242l642 +++|          SHN    2
06080  M01S00671.242l642 +++|          LMD    PN
06081  M01S00672.242l642 +++|          STD    IR+2
06082  M01S00673.242l642 +++|          LDM    SFMX
06083  M01S00674.242l642 +++|          ZJN    PRE3        IF PORT NOT ATTACHED
06084  M01S00675.242l642 +++|          LDD    IR+2
06085  M01S00676.242l642 +++|          LMN    2
06086  M01S00677.242l642 +++|          STD    IR+2
06087  M01S00678.242l642 +++| PRE3     EXECUTE  1TM
06088  M01S00679.242l642 +++|
06089  M01S00680.242l642 +++|
06090  M01S00681.242l642 +++|          QUAL   *
06091  M01S00682.242l642 +++| PREX     EQU    /PRE/PREX
06092  M01S00683.242l642 +++|          QUAL   PRE
06093  M01S00684.242l642 +++|          TITLE  DRIVER PRESET SUBROUTINES.
06094  M01S00685.242l642 +++| CEF      SPACE  4,15
06095  M01S00686.242l642 +++|**        CEF - CHECK ERROR FLAG.
06096  M01S00687.242l642 +++|*
06097  M01S00688.242l642 +++|*         CHECKS CPU ERROR FLAG.  IF SET, DROPS EQUIPMENT
06098  M01S00689.242l642 +++|*         AND CHANNEL AND DROPS THE PPU.
06099  M01S00690.242l642 +++|*
06100  M01S00691.242l642 +++|*         EXIT   TO *DPP* IF ERROR FLAG SET.
06101  M01S00692.242l642 +++|*
06102  M01S00693.242l642 +++|*         USES   CM - CM+4.
Line S00237 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06103  M01S00237.ns2149  +++|
Line S00238 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06104  M02S00238.242l642 ---|*         SET ABSOLUTE ADDRESSES AND SIGNAL INITIALIZATION COMPLETE.
Line S00239 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06105  M01S00239.ns2149  +++|
Line S00240 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06106  M02S00240.242l642 ---|          RJM    SAD         SET ABSOLUTE CM ADDRESSES
06107  M02S00241.242l642 ---|          RJM    CWA         READ DRIVER CONTROL WORD
06108  M02S00242.242l642 ---|          CRD    DC
06109  M02S00243.242l642 ---|          LDN    0           CLEAR INTERLOCK
06110  M02S00244.242l642 ---|          STD    DC
06111  M02S00245.242l642 ---|          RJM    CWA         REWRITE DRIVER CONTROL WORD
06112  M02S00246.242l642 ---|          CWD    DC
06113  M02S00247.242l642 ---|
06114  M02S00248.242l642 ---|*         PRESET TERMINAL ROUTINE ADDRESS.
06115  M02S00249.242l642 ---|
06116  M02S00250.242l642 ---|          LDN    ZERL        CLEAR *VDPT* IMAGE
06117  M02S00251.242l642 ---|          CRD    DP
06118  M02S00252.242l642 ---|          CRD    CH          CLEAR *VCHT* IMAGE
06119  M02S00253.242l642 ---|          LDC    /CTL/ONL    SET STARTING ADDRESS
06120  M02S00254.242l642 ---|          STD    DP+4
06121  M02S00255.242l642 ---|          RJM    STA         SET FWA OF TERMINAL TABLE
06122  M02S00256.242l642 ---|          ADN    VDPT        WRITE *VDPT*
06123  M02S00257.242l642 ---|          CWD    DP
06124  M02S00258.242l642 ---|          ADN    VCHT-VDPT   WRITE *VCHT*
06125  M02S00259.242l642 ---|          CWD    CH
06126  M02S00260.242l642 ---|
06127  M02S00261.242l642 ---|*         INITIALIZE MISCELLANEOUS POINTERS.
06128  M02S00262.242l642 ---|
06129  M02S00263.242l642 ---|          LDN    0           CLEAR INPUT AND OUTPUT DATA
06130  M02S00264.242l642 ---|          STD    DI
06131  M02S00265.242l642 ---|          STD    DO
06132  M02S00266.242l642 ---|          STD    HS          CLEAR HALF-SECOND FLAG
06133  M02S00267.242l642 ---|          STD    IT          CLEAR INTERVAL TIMER
06134  M02S00268.242l642 ---|          STD    PY          CLEAR ODD PARITY
06135  M02S00269.242l642 ---|          STM    OMCC        CLEAR OPERATOR MESSAGE CHARACTER COUNT
06136  M02S00270.242l642 ---|          LDCDQ  2           SET CIRCULAR QUEUE *IN*
06137  M02S00271.242l642 ---|          CRD    IN
06138  M02S00272.242l642 ---|          LDN    77          SET (LF) = *ON*
06139  M02S00273.242l642 ---|          STD    LF
06140  M02S00274.242l642 ---|
06141  M02S00275.242l642 ---|*         SET TIME-OUT IF INITIAL CALL OR EXECUTIVE RECALL.
06142  M02S00276.242l642 ---|
06143  M02S00277.242l642 ---|          LDD    IR+3        CHECK TIME-OUT
06144  M02S00278.242l642 ---|          NJN    PRS3        IF DRIVER RECALL
06145  M02S00279.242l642 ---|          RJM    SAT         SET ACTIVITY TIME-OUT
06146  M02S00280.242l642 ---| PRS3     LJM    /CTL/ITM    ENTER DRIVER MAIN LOOP
06147  M02S00281.242l642 ---|          TITLE  DRIVER PRESET SUBROUTINES.
Line S00694 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06148  M01S00694.242l642 +++| CEF      SUBR               ENTRY/EXIT
06149  M01S00695.242l642 +++|          LDD    CP          READ CP STATUS WORD
06150  M01S00696.242l642 +++|          ADK    STSW
06151  M01S00697.242l642 +++|          CRD    CM
06152  M01S00698.242l642 +++|          LDD    CM+1        CHECK ERROR FLAG
06153  M01S00699.242l642 +++|          ZJN    CEFX        IF NO ERROR FLAG
06154  M01S00700.242l642 +++|          LJM    DPP         DROP PPU
Line S00282 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06155  M01S00282.ns2149  +++| CEQ      SPACE  4,20
06156  M01S00283.ns2149  +++|**        CEQ - CHECK EQUIPMENT.
06157  M01S00284.ns2149  +++|*
06158  M01S00285.ns2149  +++|*         CHECKS FOR EQUIPMENT TYPE *RM* IN THE EST.
06159  M01S00286.ns2149  +++|*         SETS THE EST ORDINAL.
06160  M01S00287.ns2149  +++|*
06161  M01S00288.ns2149  +++|*         EXIT   (A)  = EST ORDINAL IF NONZERO.
06162  M01S00289.ns2149  +++|*                     = ZERO IF EQUIPMENT NOT FOUND.
06163  M01S00290.ns2149  +++|*                (EQ) = EST ORDINAL IF NONZERO.
06164  M01S00291.ns2149  +++|*                     = ZERO IF EQUIPMENT NOT FOUND.
06165  M01S00292.ns2149  +++|*                (PN) = PORT NUMBER IF EQUIPMENT FOUND.
06166  M01S00293.ns2149  +++|*                (RCEA) = UPPER ACCESS LEVEL LIMIT FOR TWO-PORT MUX.
06167  M01S00294.ns2149  +++|*
06168  M01S00295.ns2149  +++|*         USES   CM - CM+4, DP - DP+4, T0 - T0+4.
06169  M01S00296.ns2149  +++|*
06170  M01S00297.ns2149  +++|*         MACROS SFA.
06171  M01S00298.ns2149  +++|
06172  M01S00299.ns2149  +++|
06173  M01S00300.ns2149  +++| CEQ      SUBR               ENTRY/EXIT
06174  M01S00301.ns2149  +++|          LDN    0           PRESET NOT FOUND
06175  M01S00302.ns2149  +++|          STD    EQ
06176  M01S00303.ns2149  +++|          LDK    ESTP        READ EST POINTER
06177  M01S00304.ns2149  +++|          CRD    DP
06178  M01S00305.ns2149  +++|          LDN    NOPE-1      INITIALIZE EST ORDINAL FOR SEARCH
06179  M01S00306.ns2149  +++|          STD    DP
06180  M01S00307.ns2149  +++| CEQ1     AOD    DP          ADVANCE EST ORDINAL
06181  M01S00308.ns2149  +++|          LMD    DP+2
06182  M01S00309.ns2149  +++|          ZJN    CEQX        IF END OF EST
06183  M01S00310.ns2149  +++|          SFA    EST,DP      READ EST ENTRY
06184  M01S00311.ns2149  +++|          ADK    EQDE
06185  M01S00312.ns2149  +++|          CRD    CM
06186  M01S00313.ns2149  +++|          ADK    EQAE-EQDE
06187  M01S00314.ns2149  +++|          CRD    T0
06188  M01S00315.ns2149  +++|          LDD    CM+3        CHECK EQUIPMENT MNEMONIC
06189  M01S00316.ns2149  +++|          LMC    2RRM
06190  M01S00317.ns2149  +++|          NJN    CEQ1        IF NOT EQUIPMENT TYPE *RM*
Line S00001 Modification History
M01 (Added by) 251l664
Seq #  *Modification Id* Act 
----------------------------+
06191  M01S00001.251l664 +++|          LDD    CM
06192  M01S00002.251l664 +++|          LPN    3
06193  M01S00003.251l664 +++|          NJN    CEQ1        IF *RM* EQUIPMENT NOT *ON*
Line S00318 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06194  M01S00318.ns2149  +++|          LDD    T0+3        SAVE UPPER ACCESS LEVEL LIMIT
06195  M01S00319.ns2149  +++|          LPN    7
06196  M01S00320.ns2149  +++|          STM    RCEA
06197  M01S00321.ns2149  +++|          LDD    CM+4        SET PORT NUMBER
06198  M01S00322.ns2149  +++|          LPN    1
06199  M01S00323.ns2149  +++|          STD    PN
06200  M01S00324.ns2149  +++|          LDD    DP          EXIT WITH (A) = (EQ) = EST ORDINAL
06201  M01S00325.ns2149  +++|          STD    EQ
06202  M01S00326.ns2149  +++|          UJP    CEQX        RETURN
Line S00701 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06203  M01S00701.242l642 +++| CMF      SPACE  4,15
06204  M01S00702.242l642 +++|**        CMF - CHECK *RDF* STATUS.
06205  M01S00703.242l642 +++|*
06206  M01S00704.242l642 +++|*         CHECKS TO SEE THAT *RDF* IS ENABLED.  IF NOT,
06207  M01S00705.242l642 +++|*         ISSUE ERROR LOG MESSAGE AND EXIT TO *ERR*.
06208  M01S00706.242l642 +++|*
06209  M01S00707.242l642 +++|*         EXIT   RETURN TO CALLER IF *RDF* ENABLED.
06210  M01S00708.242l642 +++|*                TO *ERR* IF *RDF* DISABLED -
06211  M01S00709.242l642 +++|*                  ERROR LOG MESSAGE ISSUED.
06212  M01S00710.242l642 +++|*                  (A) = ADDRESS OF DAYFILE MESSAGE.
06213  M01S00711.242l642 +++|*
06214  M01S00712.242l642 +++|*         USES   T1, CM - CM+4.
06215  M01S00713.242l642 +++|*
06216  M01S00714.242l642 +++|*         CALLS  DFM.
06217  M01S00715.242l642 +++|
06218  M01S00716.242l642 +++|
06219  M01S00717.242l642 +++| CMF      SUBR               ENTRY/EXIT
06220  M01S00718.242l642 +++|          LDK    SSSL        READ SUBSYSTEM STATUS
06221  M01S00719.242l642 +++|          CRD    CM
06222  M01S00720.242l642 +++|          LDM    CMFB+1      SET MASK
06223  M01S00721.242l642 +++|          STM    CMFC
06224  M01S00722.242l642 +++|          LDM    CMFB        GET *SSSL* BYTE NUMBER
06225  M01S00723.242l642 +++|          STD    T1
06226  M01S00724.242l642 +++|          LDM    CM,T1       READ BYTE
06227  M01S00725.242l642 +++|          LPC    **
06228  M01S00726.242l642 +++| CMFC     EQU    *-1         (*RDF* MASK BIT)
06229  M01S00727.242l642 +++|          ZJN    CMFX        IF *RDF* NOT DISABLED
06230  M01S00728.242l642 +++|          LDN    MTER        * RDF TERMINATED.*
06231  M01S00729.242l642 +++|          LJM    IMT         ISSUE MESSAGE AND TERMINATE
06232  M01S00730.242l642 +++|
06233  M01S00731.242l642 +++|*         CALCULATE *SSSL* BYTE AND MASK FOR *RDF*.
06234  M01S00732.242l642 +++|
06235  M01S00733.242l642 +++| .1       SET    MXSI-RDSI
06236  M01S00734.242l642 +++| .2       SET    .1/12D
06237  M01S00735.242l642 +++| .3       SET    4-.2
06238  M01S00736.242l642 +++| .4       DECMIC .1-12D*.2
06239  M01S00737.242l642 +++| .5       SET    1S".4"
06240  M01S00738.242l642 +++|
06241  M01S00739.242l642 +++| CMFB     CON    .3          *SSSL* BYTE NUMBER
06242  M01S00740.242l642 +++|          CON    .5          *SSSL* MASK
06243  M01S00741.242l642 +++| CWA      SPACE  4,15
06244  M01S00742.242l642 +++|**        CWA - SET DRIVER CONTROL WORD ADDRESS.
06245  M01S00743.242l642 +++|*
06246  M01S00744.242l642 +++|*         RETURNS THE ABSOLUTE CM ADDRESS OF THE DRIVER CONTROL
06247  M01S00745.242l642 +++|*         WORD WITHIN *RDF* FIELD LENGTH.
06248  M01S00746.242l642 +++|*
06249  M01S00747.242l642 +++|*         ENTRY  (IR+4) = DRIVER CONTROL WORD POINTER.
06250  M01S00748.242l642 +++|*
06251  M01S00749.242l642 +++|*         EXIT   (A) = CM ADDRESS OF DRIVER CONTROL WORD.
06252  M01S00750.242l642 +++|
06253  M01S00751.242l642 +++|
06254  M01S00752.242l642 +++| CWA      SUBR               ENTRY/EXIT
06255  M01S00753.242l642 +++|          LDD    RA          SET CM ADDRESS
06256  M01S00754.242l642 +++|          SHN    6
06257  M01S00755.242l642 +++|          ADD    IR+4        ADD DRIVER CONTROL WORD POINTER
06258  M01S00756.242l642 +++|          UJN    CWAX        RETURN
06259  M01S00757.242l642 +++| DCE      SPACE  4,15
06260  M01S00758.242l642 +++|**        DCE - DROP CHANNEL AND EQUIPMENT.
06261  M01S00759.242l642 +++|*
06262  M01S00760.242l642 +++|*         ENTRY  (EQ) = BIT 2**9 SET IF EQUIPMENT RESERVED.
06263  M01S00761.242l642 +++|*
06264  M01S00762.242l642 +++|*         EXIT   CHANNEL AND EQUIPMENT DROPPED.
06265  M01S00763.242l642 +++|*                (EQ) = BIT 2**9 RESET.
06266  M01S00764.242l642 +++|*
06267  M01S00765.242l642 +++|*         USES   CM - CM+4.
06268  M01S00766.242l642 +++|*
06269  M01S00767.242l642 +++|*         CALLS  CLR, RTM.
06270  M01S00768.242l642 +++|*
06271  M01S00769.242l642 +++|*         MACROS DCHAN, MONITOR.
06272  M01S00770.242l642 +++|
06273  M01S00771.242l642 +++|
06274  M01S00772.242l642 +++| DCE      SUBR               ENTRY/EXIT
06275  M01S00773.242l642 +++|          LDD    EQ          CHECK EQUIPMENT
06276  M01S00774.242l642 +++|          SBD    TH
06277  M01S00775.242l642 +++|          MJN    DCEX        IF NOT RESERVED
06278  M01S00776.242l642 +++|          STD    EQ          CLEAR BIT 2**9
06279  M01S00777.242l642 +++|          STD    CM+1        DROP EQUIPMENT
06280  M01S00778.242l642 +++|          MONITOR  DEQM
06281  M01S00779.242l642 +++|          LDN    MX          DROP MULTIPLEXER CHANNEL
06282  M01S00780.242l642 +++|          DCHAN
06283  M01S00781.242l642 +++|          RJM    RTM         RELEASE TERMINAL ON MULTIPLEXER
06284  M01S00782.242l642 +++|          RJM    CLR         CLEAR LAST REQUEST
06285  M01S00783.242l642 +++|          UJN    DCEX        RETURN
06286  M01S00784.242l642 +++| DPP      SPACE  4,15
06287  M01S00785.242l642 +++|**        DPP - DROP PPU.
06288  M01S00786.242l642 +++|*
06289  M01S00787.242l642 +++|*         DROPS CHANNEL AND EQUIPMENT, SIGNALS DRIVER SHUTDOWN
06290  M01S00788.242l642 +++|*         TO *RDF*, AND DROPS THE PPU.
06291  M01S00789.242l642 +++|*
06292  M01S00790.242l642 +++|*         EXIT   TO *PPR*.
06293  M01S00791.242l642 +++|*
06294  M01S00792.242l642 +++|*         CALLS  DCE, SDS.
06295  M01S00793.242l642 +++|*
06296  M01S00794.242l642 +++|*         MACROS MONITOR.
06297  M01S00795.242l642 +++|
06298  M01S00796.242l642 +++|
06299  M01S00797.242l642 +++| DPP      BSS    0           ENTRY
06300  M01S00798.242l642 +++|          RJM    DCE         DISCONNECT CHANNEL AND EQUIPMENT
06301  M01S00799.242l642 +++|          RJM    SDS         SIGNAL DRIVER SHUTDOWN
06302  M01S00800.242l642 +++|          MONITOR  DPPM      DROP PPU
06303  M01S00801.242l642 +++|          LJM    PPR         EXIT TO PPU RESIDENT
Line S00327 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06304  M01S00327.ns2149  +++| INI      SPACE  4,25
06305  M01S00328.ns2149  +++|**        INI - PROCESS INITIAL LOAD.
06306  M01S00329.ns2149  +++|*
06307  M01S00330.ns2149  +++|*         PROCESSES THE INITIAL LOAD OF THE DRIVER DURING
06308  M01S00331.ns2149  +++|*         *RDF* INITIALIZATION.
06309  M01S00332.ns2149  +++|*
06310  M01S00333.ns2149  +++|*         ENTRY  (IR+4) = DRIVER CONTROL WORD POINTER.
06311  M01S00334.ns2149  +++|*                (DC - DC+4) = DRIVER CONTROL WORD.
06312  M01S00335.ns2149  +++|*
06313  M01S00336.ns2149  +++|*         EXIT   *VDRL* DRIVER CONTROL WORD INITIALIZED.
06314  M01S00337.ns2149  +++|*                MUX TABLE ENTRY INITIALIZED.
06315  M01S00338.ns2149  +++|*                (DC - DC+4) = DRIVER CONTROL WORD.
06316  M01S00339.ns2149  +++|*                (TN) = DRIVER TERMINAL NUMBER.
06317  M01S00340.ns2149  +++|*
Line S00341 Modification History
M01 (Added by) ns2149
M02 (Removed by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06318  M02S00341.v23l617 ---|*         ERROR  TO *ERR* IF NOT CYBER 170-8X5.
Line S00055 Modification History
M01 (Added by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06319  M01S00055.v23l617 +++|*         ERROR  TO *ERR* IF NOT CYBER 170-8XX.
Line S00342 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06320  M01S00342.ns2149  +++|*                  (A) = ADDRESS OF ERROR MESSAGE.
06321  M01S00343.ns2149  +++|*
06322  M01S00344.ns2149  +++|*         USES   CM - CM+4, DC - DC+4.
06323  M01S00345.ns2149  +++|*
06324  M01S00346.ns2149  +++|*         CALLS  CEF, CWA, TID.
06325  M01S00347.ns2149  +++|
06326  M01S00348.ns2149  +++|
06327  M01S00349.ns2149  +++| INI      SUBR               ENTRY/EXIT
06328  M01S00350.ns2149  +++|          RJM    STP         SYNCHRONIZE *TSEM* PROCESSING
06329  M01S00351.ns2149  +++|
06330  M01S00352.ns2149  +++|*         TRANSMIT PORT COUNT TO EXECUTIVE INITIALIZATION.
06331  M01S00353.ns2149  +++|
06332  M01S00354.ns2149  +++|          LDN    ZERL
06333  M01S00355.ns2149  +++|          CRD    CM
06334  M01S00356.ns2149  +++|          LDN    1           SET TERMINAL COUNT
06335  M01S00357.ns2149  +++|          STD    CM+3
06336  M01S00358.ns2149  +++|          STD    DC+3
06337  M01S00359.ns2149  +++|          STD    DC          SET REPLY INTERLOCK NON-ZERO
06338  M01S00360.ns2149  +++|          LDN    2           SET TERMINAL ID TABLE LENGTH
06339  M01S00361.ns2149  +++|          STD    DC+4
06340  M01S00362.ns2149  +++|          LDD    RA          WRITE MUX TABLE ENTRY
06341  M01S00363.ns2149  +++|          SHN    6
06342  M01S00364.ns2149  +++|          ADC    MUXP+VMTM
06343  M01S00365.ns2149  +++|          CWD    CM
06344  M01S00366.ns2149  +++|          RJM    CWA         SET DRIVER CONTROL WORD ADDRESS
06345  M01S00367.ns2149  +++|          CWD    DC          WRITE DRIVER CONTROL WORD
06346  M01S00368.ns2149  +++|
06347  M01S00369.ns2149  +++|*         WAIT FOR CP EXECUTIVE INITIALIZATION TO REPLY.
06348  M01S00370.ns2149  +++|
06349  M01S00371.ns2149  +++| INI2     DELAY              PAUSE FOR 128 USECS
06350  M01S00372.ns2149  +++|          RJM    CEF         CHECK ERROR FLAG
06351  M01S00373.ns2149  +++|          RJM    CWA         SET DRIVER CONTROL WORD ADDRESS
06352  M01S00374.ns2149  +++|          CRD    DC          READ DRIVER CONTROL WORD
06353  M01S00375.ns2149  +++|          LDD    DC          CHECK FOR EXECUTIVE RESPONSE
06354  M01S00376.ns2149  +++|          NJN    INI2        IF NO RESPONSE FROM EXECUTIVE
06355  M01S00377.ns2149  +++|
06356  M01S00378.ns2149  +++|*         SET TERMINAL NUMBER AND TERMINAL ID TABLE.
06357  M01S00379.ns2149  +++|
06358  M01S00380.ns2149  +++|          LDD    DC+4        SET ASSIGNED TERMINAL NUMBER
06359  M01S00381.ns2149  +++|          STD    TN
06360  M01S00382.ns2149  +++|          RJM    TID         SET TERMINAL ID TABLE
06361  M01S00383.ns2149  +++|
Line S00384 Modification History
M01 (Added by) ns2149
M02 (Removed by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06362  M02S00384.v23l617 ---|*         DROP PP IF NOT CYBER 170-8X5 MAINFRAME.
Line S00056 Modification History
M01 (Added by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06363  M01S00056.v23l617 +++|*         DROP PP IF NOT CYBER 170-8XX MAINFRAME.
Line S00385 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06364  M01S00385.ns2149  +++|
06365  M01S00386.ns2149  +++|          LDK    MABL        CHECK MAINFRAME TYPE
06366  M01S00387.ns2149  +++|          CRD    CM
06367  M01S00388.ns2149  +++|          LDD    CM+1
06368  M01S00389.ns2149  +++|          SHN    21-13
Line S00390 Modification History
M01 (Added by) ns2149
M02 (Removed by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06369  M02S00390.v23l617 ---|          PJP    INIX        IF CYBER 170-8X5
06370  M02S00391.v23l617 ---|          LDC    =C* 1TM - NOT CYBER 170-8X5.*
Line S00057 Modification History
M01 (Added by) v23l617
Seq #  *Modification Id* Act 
----------------------------+
06371  M01S00057.v23l617 +++|          PJP    INIX        IF CYBER 170-8XX MAINFRAME
Line S00058 Modification History
M01 (Added by) v23l617
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06372  M02S00058.242l642 ---|          LDC    =C* 1TM - NOT CYBER 170-8XX.*
06373  M02S00059.242l642 ---|          LDC    =C* 1TM - RDF CANNOT BE RUN ON MAINFRAME.*
Line S00392 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06374  M02S00392.242l642 ---|          LJM    ERR         PROCESS ERROR
Line S00802 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06375  M01S00802.242l642 +++|          LDN    MCBR        * RDF CANNOT BE RUN ON MAINFRAME.*
06376  M01S00803.242l642 +++|          LJM    IMT         ISSUE MESSAGE AND TERMINATE
Line S00393 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06377  M01S00393.ns2149  +++| RCE      SPACE  4,15
06378  M01S00394.ns2149  +++|**        RCE - RESERVE CHANNEL AND EQUIPMENT.
06379  M01S00395.ns2149  +++|*
06380  M01S00396.ns2149  +++|*         ENTRY  (RCEA) = UPPER ACCESS LEVEL LIMIT OF TPM.
06381  M01S00397.ns2149  +++|*
06382  M01S00398.ns2149  +++|*         EXIT   EQUIPMENT AND CHANNEL RESERVED.
Line S00399 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06383  M02S00399.242l642 ---|*                (EQ) = BIT 2**9 SET TO INDICATE THAT CHANNEL
06384  M02S00400.242l642 ---|*                       AND EQUIPMENT ARE RESERVED.
Line S00804 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06385  M01S00804.242l642 +++|*                (EQ) = BIT 2**49 SET TO INDICATE THAT EQUIPMENT
06386  M01S00805.242l642 +++|*                       IS RESERVED.
Line S00401 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06387  M01S00401.ns2149  +++|*                MUX TABLE ENTRY UPDATED WITH CH, PN, AND UAL.
06388  M01S00402.ns2149  +++|*
06389  M01S00403.ns2149  +++|*         ERROR  TO *MRER* IF EQUIPMENT NOT ASSIGNED.
06390  M01S00404.ns2149  +++|*
06391  M01S00405.ns2149  +++|*         USES   CM - CM+4.
06392  M01S00406.ns2149  +++|*
06393  M01S00407.ns2149  +++|*         MACROS RCHAN, MONITOR.
06394  M01S00408.ns2149  +++|
06395  M01S00409.ns2149  +++|
06396  M01S00410.ns2149  +++| RCE      SUBR               ENTRY/EXIT
06397  M01S00411.ns2149  +++|          LDD    EQ          CHECK EQUIPMENT
06398  M01S00412.ns2149  +++|          STD    CM+1
06399  M01S00413.ns2149  +++|          SBD    TH
06400  M01S00414.ns2149  +++|          PJN    RCEX        IF ALREADY RESERVED
Line S00806 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06401  M01S00806.242l642 +++|          LDK    REQS        REQUEST ACTIVE EQUIPMENT
06402  M01S00807.242l642 +++|          STD    CM+2
Line S00415 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06403  M01S00415.ns2149  +++|          MONITOR REQM       REQUEST EQUIPMENT
06404  M01S00416.ns2149  +++|          LDD    CM+1
06405  M01S00417.ns2149  +++|          NJN    RCE1        IF EQUIPMENT ASSIGNED
06406  M01S00418.ns2149  +++|          LJM    MRER        * 1TM - NO TPM AVAILABLE.*
06407  M01S00419.ns2149  +++|
06408  M01S00420.ns2149  +++| RCE1     LDN    MX          REQUEST CHANNEL
06409  M01S00421.ns2149  +++|          RCHAN
06410  M01S00422.ns2149  +++|          LDD    TH          SET BIT 2**9 ON EST ORDINAL
06411  M01S00423.ns2149  +++|          RAD    EQ
06412  M01S00424.ns2149  +++|          LDD    RA          READ MUX TABLE ENTRY
06413  M01S00425.ns2149  +++|          SHN    6
06414  M01S00426.ns2149  +++|          ADC    MUXP+VMTM
06415  M01S00427.ns2149  +++|          CRD    CM
06416  M01S00428.ns2149  +++|          LDN    MX          SET CHANNEL
06417  M01S00429.ns2149  +++|          SHN    6
06418  M01S00430.ns2149  +++|          LMD    PN          SET PORT NUMBER
06419  M01S00431.ns2149  +++|          STD    CM
06420  M01S00432.ns2149  +++|          LDC    *           SET UPPER ACCESS LEVEL LIMIT FOR MUX
06421  M01S00433.ns2149  +++| RCEA     EQU    *-1
06422  M01S00434.ns2149  +++|          STD    CM+2
06423  M01S00435.ns2149  +++|          LDD    RA          REWRITE MUX TABLE ENTRY
06424  M01S00436.ns2149  +++|          SHN    6
06425  M01S00437.ns2149  +++|          ADC    MUXP+VMTM
06426  M01S00438.ns2149  +++|          CWD    CM
06427  M01S00439.ns2149  +++|          UJP    RCEX        RETURN
Line S00808 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06428  M01S00808.242l642 +++| SDS      SPACE  4,15
06429  M01S00809.242l642 +++|**        SDS - SIGNAL DRIVER SHUTDOWN.
06430  M01S00810.242l642 +++|*
06431  M01S00811.242l642 +++|*         SIGNALS DRIVER SHUTDOWN BY SETTING THE DRIVER
06432  M01S00812.242l642 +++|*         SHUTDOWN FLAG IN THE DRIVER CONTROL WORD.
06433  M01S00813.242l642 +++|*
06434  M01S00814.242l642 +++|*         EXIT   DRIVER SHUTDOWN FLAG SET IN DRIVER
06435  M01S00815.242l642 +++|*                CONTROL WORD.
06436  M01S00816.242l642 +++|*
06437  M01S00817.242l642 +++|*         USES   CM - CM+4.
06438  M01S00818.242l642 +++|*
06439  M01S00819.242l642 +++|*         CALLS  CWA.
06440  M01S00820.242l642 +++|
06441  M01S00821.242l642 +++|
06442  M01S00822.242l642 +++| SDS      SUBR               ENTRY/EXIT
06443  M01S00823.242l642 +++|          RJM    CWA         SET DRIVER CONTROL WORD ADDRESS
06444  M01S00824.242l642 +++|          CRD    CM          READ DRIVER CONTROL WORD
06445  M01S00825.242l642 +++|          LDD    CM          CHECK SHUTDOWN FLAG
06446  M01S00826.242l642 +++|          NJN    SDSX        IF DRIVER SHUTDOWN ALREADY SET, RETURN
06447  M01S00827.242l642 +++|          LDN    1           SET DRIVER SHUTDOWN FLAG
06448  M01S00828.242l642 +++|          STD    CM
06449  M01S00829.242l642 +++|          RJM    CWA         REWRITE DRIVER CONTROL WORD
06450  M01S00830.242l642 +++|          CWD    CM
06451  M01S00831.242l642 +++|          UJN    SDSX        RETURN
Line S00440 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06452  M02S00440.242l642 ---| SAD      SPACE  4,15
06453  M02S00441.242l642 ---|**        SAD - SET ABSOLUTE ADDRESSES.
06454  M02S00442.242l642 ---|*
06455  M02S00443.242l642 ---|*         DETERMINES ABSOLUTE CM ADDRESS AND CALLS *SIA*
06456  M02S00444.242l642 ---|*         TO INSERT THEM INTO PP INSTRUCTIONS.
06457  M02S00445.242l642 ---|*
06458  M02S00446.242l642 ---|*         USES   T1, CM - CM+4.
06459  M02S00447.242l642 ---|*
06460  M02S00448.242l642 ---|*         CALLS  CWA, SIA.
06461  M02S00449.242l642 ---|
06462  M02S00450.242l642 ---|
06463  M02S00451.242l642 ---| SAD      SUBR               ENTRY/EXIT
06464  M02S00452.242l642 ---|
06465  M02S00453.242l642 ---|*         SET BUFFER MEMORY ADDRESS REFERENCES.
06466  M02S00454.242l642 ---|
06467  M02S00455.242l642 ---|          LDC    TBMA        SET INSTRUCTION ADDRESS TABLE POINTER
06468  M02S00456.242l642 ---|          STD    T1
06469  M02S00457.242l642 ---|          LDD    RA          READ BUFFER MEMORY POINTER
06470  M02S00458.242l642 ---|          SHN    6
06471  M02S00459.242l642 ---|          ADK    VBMP
06472  M02S00460.242l642 ---|          CRD    CM
06473  M02S00461.242l642 ---|          LDN    CM+3        SET FWA BUFFER MEMORY
06474  M02S00462.242l642 ---|          RJM    SIA         SET INSTRUCTION ADDRESSES
06475  M02S00463.242l642 ---|
06476  M02S00464.242l642 ---|*         SET DRIVER REQUEST QUEUE REFERENCES.
06477  M02S00465.242l642 ---|
06478  M02S00466.242l642 ---|          LDC    TDQA        SET INSTRUCTION ADDRESS TABLE POINTER
06479  M02S00467.242l642 ---|          STD    T1
06480  M02S00468.242l642 ---|          RJM    CWA         READ DRIVER CONTROL WORD
06481  M02S00469.242l642 ---|          CRD    CM
06482  M02S00470.242l642 ---|          LDN    CM+1        SET FWA DRIVER REQUEST QUEUE
06483  M02S00471.242l642 ---|          RJM    SIA         SET INSTRUCTION ADDRESSES
06484  M02S00472.242l642 ---|
06485  M02S00473.242l642 ---|*         SET POT LINK TABLE REFERENCES.
06486  M02S00474.242l642 ---|
06487  M02S00475.242l642 ---|          LDC    TPLA        SET INSTRUCTION ADDRESS TABLE POINTER
06488  M02S00476.242l642 ---|          STD    T1
06489  M02S00477.242l642 ---|          LDD    RA          READ POT LINK TABLE POINTER
06490  M02S00478.242l642 ---|          SHN    6
06491  M02S00479.242l642 ---|          ADK    VPLP
06492  M02S00480.242l642 ---|          CRD    CM
06493  M02S00481.242l642 ---|          LDN    CM+1        SET FWA POT LINK TABLE
06494  M02S00482.242l642 ---|          RJM    SIA         SET INSTRUCTION ADDRESSES
06495  M02S00483.242l642 ---|
06496  M02S00484.242l642 ---|
06497  M02S00485.242l642 ---|*         SET TERMINAL TABLE REFERENCES.
06498  M02S00486.242l642 ---|
06499  M02S00487.242l642 ---|          LDC    TTTA        SET INSTRUCTION ADDRESS TABLE POINTER
06500  M02S00488.242l642 ---|          STD    T1
06501  M02S00489.242l642 ---|          LDD    RA          READ TERMINAL TABLE ADDRESS POINTER
06502  M02S00490.242l642 ---|          SHN    6
06503  M02S00491.242l642 ---|          ADK    VTTP
06504  M02S00492.242l642 ---|          CRD    CM
06505  M02S00493.242l642 ---|          LDN    CM+1        SET FWA OF TERMINAL TABLES
06506  M02S00494.242l642 ---|          RJM    SIA         SET INSTRUCTION ADDRESSES
06507  M02S00495.242l642 ---|          UJP    SADX        RETURN
Line S00496 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06508  M01S00496.ns2149  +++| SEL      SPACE  4,15
06509  M01S00497.ns2149  +++|**        SEL - SELECT MULTIPLEXER PORT.
06510  M01S00498.ns2149  +++|*
06511  M01S00499.ns2149  +++|*         CALLS *STM* TO SELECT THE TPM PORT, TO GET
06512  M01S00500.ns2149  +++|*         AND STORE THE PORT STATUS AND ISSUES TPM
06513  M01S00501.ns2149  +++|*         FUNCTION CODES TO SET THE PORT OPERATING MODE,
06514  M01S00502.ns2149  +++|*         SET *DATA TERMINAL READY*, AND *REQUEST TO SEND*.
06515  M01S00503.ns2149  +++|*
06516  M01S00504.ns2149  +++|*         ENTRY  (PN) = PORT NUMBER.
06517  M01S00505.ns2149  +++|*
06518  M01S00506.ns2149  +++|*         EXIT   PORT SELECTED.
06519  M01S00507.ns2149  +++|*                (SSMX) = PORT STATUS.
06520  M01S00508.ns2149  +++|*                TO *MRER* IF PORT NOT RESERVED.
06521  M01S00509.ns2149  +++|*
06522  M01S00510.ns2149  +++|*         CALLS  IFN, PMA, RMA, STM.
06523  M01S00511.ns2149  +++|
06524  M01S00512.ns2149  +++|
06525  M01S00513.ns2149  +++| SEL      SUBR               ENTRY/EXIT
06526  M01S00514.ns2149  +++|          RJM    PMA         PRESET MUX ACCESS
06527  M01S00515.ns2149  +++|          LDD    PN          GET PORT NUMBER
Line S00516 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06528  M02S00516.242l642 ---|          RJM    STM         SELECT TERMINAL ON MUX
Line S00832 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06529  M01S00832.242l642 +++|          LDC    PRTO        SET TIME OUT DELAY
06530  M01S00833.242l642 +++|          STD    T2
06531  M01S00834.242l642 +++|          LDD    PN          GET PORT NUMBER
06532  M01S00835.242l642 +++|          RJM    SPN         SET PORT NUMBER
06533  M01S00836.242l642 +++| SEL1     RJM    STM
Line S00517 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06534  M02S00517.242l642 ---|          NJN    SEL1        IF PORT RESERVED
Line S00837 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06535  M01S00837.242l642 +++|          NJN    SEL3        IF PORT RESERVED
06536  M01S00838.242l642 +++|          LDN    100D/4      DELAY 100 MILLISECONDS
06537  M01S00839.242l642 +++|          STD    T0
06538  M01S00840.242l642 +++| SEL2     DELAY
06539  M01S00841.242l642 +++|          RJM    CEF         CHECK ERROR FLAG
06540  M01S00842.242l642 +++|          RJM    CTE
06541  M01S00843.242l642 +++|          PJN    SEL2        IF 100 MILLISECONDS NOT EXPIRED
06542  M01S00844.242l642 +++|          SOD    T2
06543  M01S00845.242l642 +++|          NJN    SEL1        IF TIME OUT NOT EXPIRED
Line S00518 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06544  M01S00518.ns2149  +++|          LJM    MRER        * 1TM - NO TPM AVAILABLE.*
06545  M01S00519.ns2149  +++|
Line S00520 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06546  M02S00520.242l642 ---| SEL1     LDC    MXSM+TPMODE SET PORT OPERATING MODE
Line S00846 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06547  M01S00846.242l642 +++| SEL3     LDC    MXSM+TPMODE SET PORT OPERATING MODE
Line S00521 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06548  M01S00521.ns2149  +++|          RJM    IFN
06549  M01S00522.ns2149  +++|          LDK    MXDR+1      SET *DATA TERMINAL READY*
06550  M01S00523.ns2149  +++|          RJM    IFN
06551  M01S00524.ns2149  +++|          LDK    MXRTS+1     SET *REQUEST TO SEND*
06552  M01S00525.ns2149  +++|          RJM    IFN
06553  M01S00526.ns2149  +++|          LDK    MXMC        CLEAR PORT I/O BUFFERS
06554  M01S00527.ns2149  +++|          RJM    IFN
06555  M01S00528.ns2149  +++|          RJM    RMA         RELEASE MULTIPLEXER ACCESS
Line S00529 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06556  M02S00529.242l642 ---|          UJN    SELX        RETURN
Line S00847 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06557  M01S00847.242l642 +++|          UJP    SELX        RETURN
Line S00530 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06558  M02S00530.242l642 ---| SIA      SPACE  4,15
06559  M02S00531.242l642 ---|**        SIA - SET INSTRUCTION ADDRESSES.
06560  M02S00532.242l642 ---|*
06561  M02S00533.242l642 ---|*         SETS ABSOLUTE ADDRESSES IN INSTRUCTION ADDRESS
06562  M02S00534.242l642 ---|*         FIELDS.
06563  M02S00535.242l642 ---|*
06564  M02S00536.242l642 ---|*         ENTRY  (T1) = ADDRESS OF TABLE OF INSTRUCTION
06565  M02S00537.242l642 ---|*                       ADDRESSES.
06566  M02S00538.242l642 ---|*                (A) = ADDRESS IN PP OF CM ADDRESS.
06567  M02S00539.242l642 ---|*
06568  M02S00540.242l642 ---|*         USES   T2, T6, T7.
06569  M02S00541.242l642 ---|
06570  M02S00542.242l642 ---|
06571  M02S00543.242l642 ---| SIA      SUBR               ENTRY/EXIT
06572  M02S00544.242l642 ---|          STD    T2          SAVE ADDRESS POINTER
06573  M02S00545.242l642 ---|          LDI    T2          GET ABSOLUTE ADDRESS
06574  M02S00546.242l642 ---|          SHN    6           ABSOLUTE RELATIVE ADDRESS
06575  M02S00547.242l642 ---|          ADD    RA
06576  M02S00548.242l642 ---|          SHN    6
06577  M02S00549.242l642 ---|          ADM    1,T2
06578  M02S00550.242l642 ---|          STD    T7          SAVE LOWER 12 BITS
06579  M02S00551.242l642 ---|          SHN    -14
06580  M02S00552.242l642 ---|          STD    T6
06581  M02S00553.242l642 ---|
06582  M02S00554.242l642 ---| SIA1     LDI    T1          READ INSTRUCTION ADDRESS
06583  M02S00555.242l642 ---|          ZJP    SIAX        IF END OF ADDRESS TABLE
06584  M02S00556.242l642 ---|          STD    T2
06585  M02S00557.242l642 ---|          LDD    T7          SET LOWER 12 BITS
06586  M02S00558.242l642 ---|          RAM    1,T2
06587  M02S00559.242l642 ---|          SHN    -14
06588  M02S00560.242l642 ---|          ADD    T6          ADD OVERFLOW
06589  M02S00561.242l642 ---|          RAI    T2          SET UPPER 6 BITS
06590  M02S00562.242l642 ---|          AOD    T1          ADVANCE TABLE INDEX
06591  M02S00563.242l642 ---|          UJN    SIA1        LOOP TO END OF TABLE
Line S00564 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06592  M01S00564.ns2149  +++| STP      SPACE  4,15
06593  M01S00565.ns2149  +++|**        STP - SYNCHRONIZE MONITOR *TSEM* PROCESSING.
06594  M01S00566.ns2149  +++|*
06595  M01S00567.ns2149  +++|*         ISSUE SPECIAL *TSEM* REQUEST TO ENABLE
06596  M01S00568.ns2149  +++|*         *TSEM* REQUEST PROCESSING.
06597  M01S00569.ns2149  +++|*
06598  M01S00570.ns2149  +++|*         ENTRY  (IR+4) = DRIVER CONTROL WORD POINTER.
06599  M01S00571.ns2149  +++|*
06600  M01S00572.ns2149  +++|*         USES   CM - CM+4.
06601  M01S00573.ns2149  +++|*
06602  M01S00574.ns2149  +++|*         MACROS MONITOR.
06603  M01S00575.ns2149  +++|
06604  M01S00576.ns2149  +++|
06605  M01S00577.ns2149  +++| STP      SUBR               ENTRY/EXIT
06606  M01S00578.ns2149  +++|          LDK    ZERL        CLEAR ZERO WORD
06607  M01S00579.ns2149  +++|          CRD    CM
06608  M01S00580.ns2149  +++|          LCN    0           SET *TSEM* REQUEST
06609  M01S00581.ns2149  +++|          STD    CM
06610  M01S00582.ns2149  +++|          LDD    MA          WRITE REQUEST TO MESSAGE BUFFER
06611  M01S00583.ns2149  +++|          CWD    CM
06612  M01S00584.ns2149  +++|          MONITOR TSEM       ISSUE *TSEM* REQUEST
06613  M01S00585.ns2149  +++|          UJN    STPX        RETURN
06614  M01S00586.ns2149  +++| TID      SPACE  4,15
06615  M01S00587.ns2149  +++|**        TID - SET TERMINAL ID TABLE.
06616  M01S00588.ns2149  +++|*
06617  M01S00589.ns2149  +++|*         WRITES DRIVER TERMINAL ID TABLE TO CM.
06618  M01S00590.ns2149  +++|*
06619  M01S00591.ns2149  +++|*         ENTRY  (DC - DC+4) = DRIVER CONTROL WORD.
06620  M01S00592.ns2149  +++|*
06621  M01S00593.ns2149  +++|*         EXIT   DRIVER TERMINAL ID TABLE WRITTEN TO CM.
06622  M01S00594.ns2149  +++|*
06623  M01S00595.ns2149  +++|*         USES   CM - CM+4.
06624  M01S00596.ns2149  +++|
06625  M01S00597.ns2149  +++|
06626  M01S00598.ns2149  +++| TID      SUBR               ENTRY/EXIT
06627  M01S00599.ns2149  +++|          LDD    DC+1        SET DRIVER STACK ADDRESS
06628  M01S00600.ns2149  +++|          SHN    6
06629  M01S00601.ns2149  +++|          ADD    RA
06630  M01S00602.ns2149  +++|          SHN    6
06631  M01S00603.ns2149  +++|          ADD    DC+2
06632  M01S00604.ns2149  +++|          ADN    4           READ *LIMIT* POINTER
06633  M01S00605.ns2149  +++|          CRD    CM
06634  M01S00606.ns2149  +++|          LDD    CM+3        SET ADDRESS FOR ID TABLE
06635  M01S00607.ns2149  +++|          SHN    6
06636  M01S00608.ns2149  +++|          ADD    RA
06637  M01S00609.ns2149  +++|          SHN    6
06638  M01S00610.ns2149  +++|          ADD    CM+4
06639  M01S00611.ns2149  +++|          CWM    TIDA,ON     WRITE ID TABLE TO CM
06640  M01S00612.ns2149  +++|          CWM    TIDB,ON
06641  M01S00613.ns2149  +++|          UJN    TIDX        RETURN
06642  M01S00614.ns2149  +++|
06643  M01S00615.ns2149  +++|
Line S00616 Modification History
M01 (Added by) ns2149
M02 (Removed by) 1tm10
Seq #  *Modification Id* Act 
----------------------------+
06644  M02S00616.1tm10   ---| TIDA     DATA   10LTPM        TPM TERMINAL ID
06645  M02S00617.1tm10   ---| TIDB     DATA   10LBLKTPM     BLKEDIT TPM TERMINAL ID
Line S00001 Modification History
M01 (Added by) 1tm10
Seq #  *Modification Id* Act 
----------------------------+
06646  M01S00001.1tm10   +++| TIDA     VFD    60/3LTPM    TPM TERMINAL ID
06647  M01S00002.1tm10   +++| TIDB     VFD    60/6LBLKTPM  BLKEDIT TPM TERMINAL ID
Line S00848 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06648  M01S00848.242l642 +++|          TITLE  ERROR PROCESSING ROUTINES.
06649  M01S00849.242l642 +++| FTER     SPACE  4,10
06650  M01S00850.242l642 +++|**        FTER - FUNCTION TIME-OUT ERROR PROCESSOR.
06651  M01S00851.242l642 +++|*
06652  M01S00852.242l642 +++|*         ENTRY  (A) = FUNCTION CODE.
06653  M01S00853.242l642 +++|*
06654  M01S00854.242l642 +++|*         EXIT   (A) = 1/ERROR LOG FLAG, 5/MESSAGE NUMBER.
06655  M01S00855.242l642 +++|
06656  M01S00856.242l642 +++|
06657  M01S00857.242l642 +++| FTER     BSS    0           ENTRY
06658  M01S00858.242l642 +++|          STM    //IMTB      SAVE FUNCTION CODE
06659  M01S00859.242l642 +++|          LDN    MFTO+40     * RMEEE CXX PYY FNNNN REJECT.*
06660  M01S00860.242l642 +++|*         JMP    IMT         ISSUE MESSAGE AND TERMINATE
06661  M01S00861.242l642 +++| IMT      SPACE  4,10
06662  M01S00862.242l642 +++|**        IMT - ISSUE MESSAGE AND TERMINATE.
06663  M01S00863.242l642 +++|*
06664  M01S00864.242l642 +++|*         ENTRY  (A) = 1/ERROR LOG FLAG, 5/MESSAGE NUMBER.
06665  M01S00865.242l642 +++|*
06666  M01S00866.242l642 +++|*         EXIT   TO *4TM*.
06667  M01S00867.242l642 +++|*
06668  M01S00868.242l642 +++|*         MACROS EXECUTE.
06669  M01S00869.242l642 +++|
06670  M01S00870.242l642 +++|
06671  M01S00871.242l642 +++| IMT      BSS    0           ENTRY
06672  M01S00872.242l642 +++|          STM    //IMTA      SAVE MESSAGE REQUEST
06673  M01S00873.242l642 +++|          EXECUTE  4TM
06674  M01S00874.242l642 +++|          LJM    DPP         DROP PP
06675  M01S00875.242l642 +++| MRER     SPACE  4,10
06676  M01S00876.242l642 +++|**        MRER - NORMAL ERROR PROCESSOR FOR *COMPMRA*.
06677  M01S00877.242l642 +++|*
06678  M01S00878.242l642 +++|*         EXIT   (A) = MESSAGE NUMBER.
06679  M01S00879.242l642 +++|
06680  M01S00880.242l642 +++|
06681  M01S00881.242l642 +++| MRER     BSS    0           ENTRY
06682  M01S00882.242l642 +++|          LDN    MNTA        * NO TPM AVAILABLE.*
06683  M01S00883.242l642 +++|          UJN    IMT         ISSUE MESSAGE AND TERMINATE
Line S00618 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06684  M01S00618.ns2149  +++|          SPACE  4,10
Line S00884 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06685  M01S00884.242l642 +++|*         COMMON DECKS.
06686  M01S00885.242l642 +++|
06687  M01S00886.242l642 +++|*CALL     COMPMRA
06688  M01S00887.242l642 +++|*CALL     COMPTMA
06689  M01S00888.242l642 +++| PMA      HERE
06690  M01S00889.242l642 +++|          SPACE  4,10
06691  M01S00890.242l642 +++|          QUAL   *
06692  M01S00891.242l642 +++|          SPACE  4,10
Line S00619 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06693  M02S00619.242l642 ---|          QUAL
06694  M02S00620.242l642 ---| PMA      HERE
06695  M02S00621.242l642 ---| ITM      TITLE  INITIALIZATION TABLES.
06696  M02S00622.242l642 ---| ITM      SPACE  4,15
06697  M02S00623.242l642 ---|**        TABLES OF CENTRAL MEMORY REFERENCE INSTRUCTION
06698  M02S00624.242l642 ---|*         ADDRESSES.
06699  M02S00625.242l642 ---|
06700  M02S00626.242l642 ---|
06701  M02S00627.242l642 ---| TBMA     BSS    0           BUFFER MEMORY REFERENCES
06702  M02S00628.242l642 ---| TBMA     HERE
06703  M02S00629.242l642 ---|          CON    0
06704  M02S00630.242l642 ---|
06705  M02S00631.242l642 ---| TDQA     BSS    0           DRIVER REQUEST QUEUE REFERENCES
06706  M02S00632.242l642 ---| TDQA     HERE
06707  M02S00633.242l642 ---|          CON    0
06708  M02S00634.242l642 ---|
06709  M02S00635.242l642 ---| TPLA     BSS    0           POT LINK TABLE REFERENCES
06710  M02S00636.242l642 ---| TPLA     HERE
06711  M02S00637.242l642 ---|          CON    0
06712  M02S00638.242l642 ---|
06713  M02S00639.242l642 ---| TTTA     BSS    0           TERMINAL TABLE REFERENCES
06714  M02S00640.242l642 ---| TTTA     HERE
06715  M02S00641.242l642 ---|          CON    0
06716  M02S00642.242l642 ---|          SPACE  4,10
06717  M02S00643.242l642 ---|          USE    *
06718  M02S00644.242l642 ---|          QUAL
06719  M02S00645.242l642 ---|
06720  M02S00646.242l642 ---|          OVERFLOW
06721  M02S00647.242l642 ---|          TTL    1TM/2TM - MODIFY TRANSLATION TABLES.
Line S00892 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06722  M01S00892.242l642 +++|          OVERFLOW  PPFW,IMTA
Line S00648 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06723  M01S00648.ns2149  +++|          TITLE
Line S00649 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06724  M02S00649.242l642 ---|          IDENT  2TM,MTTX
Line S00893 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06725  M01S00893.242l642 +++|          TTL    1TM/3TM - MODIFY TRANSLATION TABLES.
06726  M01S00894.242l642 +++|          IDENT  3TM,MTTX
Line S00650 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06727  M01S00650.ns2149  +++|*COMMENT  1TM - MODIFY TRANSLATION TABLES.
Line S00651 Modification History
M01 (Added by) ns2149
M02 (Removed by) 281l803
Seq #  *Modification Id* Act 
----------------------------+
06728  M02S00651.281l803 ---|          COMMENT  COPYRIGHT CONTROL DATA CORPORATION, 1983.
Line S00003 Modification History
M01 (Added by) 281l803
Seq #  *Modification Id* Act 
----------------------------+
06729  M01S00003.281l803 +++|          COMMENT  COPYRIGHT CONTROL DATA SYSTEMS INC.  1992.
Line S00652 Modification History
M01 (Added by) ns2149
M02 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06730  M02S00652.242l642 ---| 2TM      SPACE  4,10
06731  M02S00653.242l642 ---|***       2TM - MODIFY TRANSLATION TABLES.
Line S00895 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06732  M01S00895.242l642 +++| 3TM      SPACE  4,10
06733  M01S00896.242l642 +++|***       3TM - MODIFY TRANSLATION TABLES.
Line S00654 Modification History
M01 (Added by) ns2149
Seq #  *Modification Id* Act 
----------------------------+
06734  M01S00654.ns2149  +++|          SPACE  4,10
06735  M01S00655.ns2149  +++|          ORG    OVLA
06736  M01S00656.ns2149  +++| MTT      SPACE  4,15
06737  M01S00657.ns2149  +++|**        MTT - MODIFY TRANSLATION TABLES.
06738  M01S00658.ns2149  +++|*
06739  M01S00659.ns2149  +++|*         MODIFIES TRANSLATION TABLES FOR 63 CHARACTER SET.
06740  M01S00660.ns2149  +++|*
06741  M01S00661.ns2149  +++|*         EXIT   TRANSLATION TABLES MODIFIED IF THE SYSTEM
06742  M01S00662.ns2149  +++|*                IS IN 63 CHARACTER SET MODE.
06743  M01S00663.ns2149  +++|*
06744  M01S00664.ns2149  +++|*         USES   CM - CM+4.
06745  M01S00665.ns2149  +++|
06746  M01S00666.ns2149  +++|
06747  M01S00667.ns2149  +++| MTT      SUBR               ENTRY/EXIT
06748  M01S00668.ns2149  +++|          LDK    IPRL        CHECK SYSTEM CHARACTER SET MODE
06749  M01S00669.ns2149  +++|          CRD    CM
06750  M01S00670.ns2149  +++|          LDD    CM+2
06751  M01S00671.ns2149  +++|          LPN    1
06752  M01S00672.ns2149  +++|          NJN    MTTX        IF SYSTEM IN 64 CHARACTER SET MODE
06753  M01S00673.ns2149  +++|
06754  M01S00674.ns2149  +++|*         MODIFY INPUT CONVERSION TABLE.
06755  M01S00675.ns2149  +++|
06756  M01S00676.ns2149  +++|          LDN    63          SET *COLON*
06757  M01S00677.ns2149  +++|          STM    TINT+.ACLN
06758  M01S00678.ns2149  +++|          LDC    204         SET *PERCENT*
06759  M01S00679.ns2149  +++|          STM    TINT+.APCT
06760  M01S00680.ns2149  +++|
06761  M01S00681.ns2149  +++|*         MODIFY OUTPUT CONVERSION TABLE.
06762  M01S00682.ns2149  +++|
06763  M01S00683.ns2149  +++|          LDC    .CCLN       SET *COLON*
06764  M01S00684.ns2149  +++|          STM    TOTP+63
06765  M01S00685.ns2149  +++|          LDC    .CPCT       SET *PERCENT*
06766  M01S00686.ns2149  +++|          STM    TOTP+204
06767  M01S00687.ns2149  +++|          JMP    MTTX        RETURN
06768  M00S05020.1tm     +++|          TITLE  INPUT TRANSLATION TABLE.
06769  M00S05021.1tm     +++| TTY      SPACE  4,15
06770  M00S05022.1tm     +++|***       TTY - *ASCII* TERMINAL, 64 CHARACTER SET.
06771  M00S05023.1tm     +++|*
06772  M00S05024.1tm     +++|*         USA STANDARD CODE FOR INFORMATION INTERCHANGE.
06773  M00S05025.1tm     +++|*         USAS X3.4-1968 REVISION OF X3.4-1967.
06774  M00S05026.1tm     +++|
06775  M00S05027.1tm     +++|
06776  M00S05028.1tm     +++|**        INPUT CONVERSION.
06777  M00S05029.1tm     +++|*
06778  M00S05030.1tm     +++|*         INDEXED BY *ASCII* CHARACTER VALUE.
06779  M00S05031.1tm     +++|
06780  M00S05032.1tm     +++|
06781  M00S05033.1tm     +++| TINT     BSS    0           FWA OF INPUT TRANSLATION TABLE
06782  M00S05034.1tm     +++|          QUAL   TRN
06783  M00S05035.1tm     +++|          LOC    0
06784  M00S05036.1tm     +++|
06785  M00S05037.1tm     +++| 00       INASC  7640,BRK    NUL  FIRST CHARACTER OF A BREAK
06786  M00S05038.1tm     +++| 01       INASC  7641        SOH  START OF HEADING
06787  M00S05039.1tm     +++| 02       INASC  7642        STX  START OF TEXT
06788  M00S05040.1tm     +++| 03       INASC  7643,ETX    ETX  END OF TEXT
06789  M00S05041.1tm     +++| 04       INASC  7644,EOT    EOT  END OF TRANSMISSION
06790  M00S05042.1tm     +++| 05       INASC  7645        ENQ  ENQUIRY
06791  M00S05043.1tm     +++| 06       INASC  7646        ACK  ACKNOWLEDGE
06792  M00S05044.1tm     +++| 07       INASC  7647        BEL  BELL
06793  M00S05045.1tm     +++| 08       INASC  7650,DPC    BS   BACKSPACE
06794  M00S05046.1tm     +++| 09       INASC  7651        HT   HORIZONTAL TABULATION
06795  M00S05047.1tm     +++| 0A       INASC  7652,NLI    LF   LINE FEED
06796  M00S05048.1tm     +++| 0B       INASC  7653        VT   VERTICAL TABULATION
06797  M00S05049.1tm     +++| 0C       INASC  7654        FF   FORM FEED
06798  M00S05050.1tm     +++| 0D       INASC  7655,CRT    CR   CARRIAGE RETURN
06799  M00S05051.1tm     +++| 0E       INASC  7656        SO   SHIFT OUT
06800  M00S05052.1tm     +++| 0F       INASC  7657        SI   SHIFT IN
06801  M00S05053.1tm     +++|
06802  M00S05054.1tm     +++| 10       INASC  7660        DLE  DATA LINK ESCAPE
06803  M00S05055.1tm     +++| 11       INASC  7661        DC1  DEVICE CONTROL 1 (X-ON)
06804  M00S05056.1tm     +++| 12       INASC  7662        DC2  DEVICE CONTROL 2
06805  M00S05057.1tm     +++| 13       INASC  7663        DC3  DEVICE CONTROL 3 (X-OFF)
06806  M00S05058.1tm     +++| 14       INASC  7664        DC4  DEVICE CONTROL 4 (STOP)
06807  M00S05059.1tm     +++| 15       INASC  7665        NAK  NEGATIVE ACKNOWLEDGE
06808  M00S05060.1tm     +++| 16       INASC  7666        SYN  SYNCHRONOUS IDLE
06809  M00S05061.1tm     +++| 17       INASC  7667        ETB  END OF TRANSMISSION BLOCK
06810  M00S05062.1tm     +++| 18       INASC  7670        CAN  CANCEL
06811  M00S05063.1tm     +++| 19       INASC  7671        EM   END OF MEDIUM
06812  M00S05064.1tm     +++| 1A       INASC  7672        SUB  SUBSTITUTE
06813  M00S05065.1tm     +++| 1B       INASC  7673,DLN    ESC  ESCAPE
06814  M00S05066.1tm     +++| 1C       INASC  7674        FS   FILE SEPARATOR
06815  M00S05067.1tm     +++| 1D       INASC  7675        GS   GROUP SEPARATOR
Line S05068 Modification History
M01 (Removed by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06816  M01S05068.242l642 ---| 1E       INASC  7676        RS   RECORD SEPARATOR
Line S00897 Modification History
M01 (Added by) 242l642
Seq #  *Modification Id* Act 
----------------------------+
06817  M01S00897.242l642 +++| 1E       INASC  7676,CRS    RS   RECORD SEPARATOR
06818  M00S05069.1tm     +++| 1F       INASC  7677        US   UNIT SEPARATOR
06819  M00S05070.1tm     +++|
06820  M00S05071.1tm     +++| 20       INASC  55          SP   SPACE
06821  M00S05072.1tm     +++| 21       INASC  66          EX   EXCLAMATION POINT
06822  M00S05073.1tm     +++| 22       INASC  64          DQ   DOUBLE QUOTE (DIARESIS)
06823  M00S05074.1tm     +++| 23       INASC  60          NM   NUMBER SIGN
06824  M00S05075.1tm     +++| 24       INASC  53          DS   DOLLAR SIGN
06825  M00S05076.1tm     +++| 25       INASC  63          PCT  PERCENT
06826  M00S05077.1tm     +++|* 25      INASC  7404        PCT  PERCENT (63 CHARACTER SET)
06827  M00S05078.1tm     +++| 26       INASC  67          AM   AMPERSAND
06828  M00S05079.1tm     +++| 27       INASC  70          AP   APOSTROPHE
06829  M00S05080.1tm     +++| 28       INASC  51          OP   OPENING PARENTHESIS
06830  M00S05081.1tm     +++| 29       INASC  52          CP   CLOSING PARENTHESIS
06831  M00S05082.1tm     +++| 2A       INASC  47          AS   ASTERISK
06832  M00S05083.1tm     +++| 2B       INASC  45          PL   PLUS
06833  M00S05084.1tm     +++| 2C       INASC  56          CM   COMMA (CEDILLA)
06834  M00S05085.1tm     +++| 2D       INASC  46          MI   MINUS (HYPHEN)
06835  M00S05086.1tm     +++| 2E       INASC  57          PD   PERIOD (DECIMAL POINT)
06836  M00S05087.1tm     +++| 2F       INASC  50          SL   SLANT
06837  M00S05088.1tm     +++|
06838  M00S05089.1tm     +++| 30       INASC  33          0
06839  M00S05090.1tm     +++| 31       INASC  34          1
06840  M00S05091.1tm     +++| 32       INASC  35          2
06841  M00S05092.1tm     +++| 33       INASC  36          3
06842  M00S05093.1tm     +++| 34       INASC  37          4
06843  M00S05094.1tm     +++| 35       INASC  40          5
06844  M00S05095.1tm     +++| 36       INASC  41          6
06845  M00S05096.1tm     +++| 37       INASC  42          7
06846  M00S05097.1tm     +++| 38       INASC  43          8
06847  M00S05098.1tm     +++| 39       INASC  44          9
06848  M00S05099.1tm     +++| 3A       INASC  ,CLN        CL   COLON
06849  M00S05100.1tm     +++|* 3A      INASC  63          CL   COLON (63 CHARACTER SET)
06850  M00S05101.1tm     +++| 3B       INASC  77          SC   SEMICOLON
06851  M00S05102.1tm     +++| 3C       INASC  72          LT   LESS THAN
06852  M00S05103.1tm     +++| 3D       INASC  54          EQ   EQUALS
06853  M00S05104.1tm     +++| 3E       INASC  73          GT   GREATER THAN
06854  M00S05105.1tm     +++| 3F       INASC  71          QM   QUESTION MARK
06855  M00S05106.1tm     +++|
06856  M00S05107.1tm     +++| 40       INASC  7401,ECI    AT   COMMERCIAL AT
06857  M00S05108.1tm     +++| 41       INASC  01          A
06858  M00S05109.1tm     +++| 42       INASC  02          B
06859  M00S05110.1tm     +++| 43       INASC  03          C
06860  M00S05111.1tm     +++| 44       INASC  04          D
06861  M00S05112.1tm     +++| 45       INASC  05          E
06862  M00S05113.1tm     +++| 46       INASC  06          F
06863  M00S05114.1tm     +++| 47       INASC  07          G
06864  M00S05115.1tm     +++| 48       INASC  10          H
06865  M00S05116.1tm     +++| 49       INASC  11          I
06866  M00S05117.1tm     +++| 4A       INASC  12          J
06867  M00S05118.1tm     +++| 4B       INASC  13          K
06868  M00S05119.1tm     +++| 4C       INASC  14          L
06869  M00S05120.1tm     +++| 4D       INASC  15          M
06870  M00S05121.1tm     +++| 4E       INASC  16          N
06871  M00S05122.1tm     +++| 4F       INASC  17          O
06872  M00S05123.1tm     +++|
06873  M00S05124.1tm     +++| 50       INASC  20          P
06874  M00S05125.1tm     +++| 51       INASC  21          Q
06875  M00S05126.1tm     +++| 52       INASC  22          R
06876  M00S05127.1tm     +++| 53       INASC  23          S
06877  M00S05128.1tm     +++| 54       INASC  24          T
06878  M00S05129.1tm     +++| 55       INASC  25          U
06879  M00S05130.1tm     +++| 56       INASC  26          V
06880  M00S05131.1tm     +++| 57       INASC  27          W
06881  M00S05132.1tm     +++| 58       INASC  30          X
06882  M00S05133.1tm     +++| 59       INASC  31          Y
06883  M00S05134.1tm     +++| 5A       INASC  32          Z
06884  M00S05135.1tm     +++| 5B       INASC  61          OB   OPENING BRACKET
06885  M00S05136.1tm     +++| 5C       INASC  75          RVS  REVERSE SLANT
06886  M00S05137.1tm     +++| 5D       INASC  62          CB   CLOSING BRACKET
06887  M00S05138.1tm     +++| 5E       INASC  7402,ECI    CF   CIRCUMFLEX
06888  M00S05139.1tm     +++| 5F       INASC  65          UL   UNDERLINE
06889  M00S05140.1tm     +++|
06890  M00S05141.1tm     +++| 60       INASC  7407        GV   GRAVE ACCENT
06891  M00S05142.1tm     +++| 61       INASC  7601        A    LC
06892  M00S05143.1tm     +++| 62       INASC  7602        B    LC
06893  M00S05144.1tm     +++| 63       INASC  7603        C    LC
06894  M00S05145.1tm     +++| 64       INASC  7604        D    LC
06895  M00S05146.1tm     +++| 65       INASC  7605        E    LC
06896  M00S05147.1tm     +++| 66       INASC  7606        F    LC
06897  M00S05148.1tm     +++| 67       INASC  7607        G    LC
06898  M00S05149.1tm     +++| 68       INASC  7610        H    LC
06899  M00S05150.1tm     +++| 69       INASC  7611        I    LC
06900  M00S05151.1tm     +++| 6A       INASC  7612        J    LC
06901  M00S05152.1tm     +++| 6B       INASC  7613        K    LC
06902  M00S05153.1tm     +++| 6C       INASC  7614        L    LC
06903  M00S05154.1tm     +++| 6D       INASC  7615        M    LC
06904  M00S05155.1tm     +++| 6E       INASC  7616        N    LC
06905  M00S05156.1tm     +++| 6F       INASC  7617        O    LC
06906  M00S05157.1tm     +++|
06907  M00S05158.1tm     +++| 70       INASC  7620        P    LC
06908  M00S05159.1tm     +++| 71       INASC  7621        Q    LC
06909  M00S05160.1tm     +++| 72       INASC  7622        R    LC
06910  M00S05161.1tm     +++| 73       INASC  7623        S    LC
06911  M00S05162.1tm     +++| 74       INASC  7624        T    LC
06912  M00S05163.1tm     +++| 75       INASC  7625        U    LC
06913  M00S05164.1tm     +++| 76       INASC  7626        V    LC
Proceed to Part 4
cdc/nos2.source/opl.opl871/deck/1tm.003.txt ยท Last modified: by 127.0.0.1