cdc:nos2.source:opl.opl871:deck:6dx
Deck 6DX
Library Member Format: MODIFY
Source
Seq # *Modification Id* Act ----------------------------+ 00001 M00S00001.6dx +++| IDENT 6DX,MSFW 00002 M00S00002.6dx +++| PERIPH 00003 M00S00003.6dx +++| BASE MIXED 00004 M00S00004.6dx +++| SST 00005 M00S00005.6dx +++| TITLE 6DX - UEM DRIVER. 00006 M00S00006.6dx +++|*COMMENT 6DX - UEM DRIVER.
Line S00007 Modification History | |
---|---|
M01 (Removed by) | 281l803 |
Seq # *Modification Id* Act ----------------------------+ 00007 M01S00007.281l803 ---| COMMENT COPYRIGHT CONTROL DATA CORPORATION. 1981.
Line S00001 Modification History | |
---|---|
M01 (Added by) | 281l803 |
Seq # *Modification Id* Act ----------------------------+ 00008 M01S00001.281l803 +++| COMMENT COPYRIGHT CONTROL DATA SYSTEMS INC. 1992. 00009 M00S00008.6dx +++| SPACE 4,10 00010 M00S00009.6dx +++|***** 6DX - UEM DRIVER. 00011 M00S00010.6dx +++|* C. B. LOSCHEIDER. 81/03/04. 00012 M00S00011.6dx +++| SPACE 4,10 00013 M00S00012.6dx +++|*** 6DX PROVIDES THE CAPABILITY TO ACCESS UEM. 00014 M00S00013.6dx +++| SPACE 4,10 00015 M00S00014.6dx +++|*** ORGANIZATION OF UEM. 00016 M00S00015.6dx +++|* UEM IS TREATED AS A SINGLE DEVICE. 00017 M00S00016.6dx +++|* 00018 M00S00017.6dx +++|* EQUIPMENT TYPE IS *DE*. 00019 M00S00018.6dx +++|*
Line S00019 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00020 M01S00019.252l678 ---|* SECTORS/TRACK = 16D.
Line S00001 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00021 M01S00001.252l678 +++|* SECTORS/TRACK = SLDE (20B, 40B, 100B, OR 200B). 00022 M00S00020.6dx +++|*
Line S00021 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00023 M01S00021.252l678 ---|* WORDS/TRACK = 2020B.
Line S00002 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00024 M01S00002.252l678 +++|* WORDS/TRACK = 101B*SLDE. 00025 M00S00022.6dx +++| SPACE 4,10 00026 M00S00023.6dx +++|** ENTRY CONDITIONS. 00027 M00S00024.6dx +++|* 00028 M00S00025.6dx +++|* 00029 M00S00026.6dx +++|* (T5) = EST ORDINAL. 00030 M00S00027.6dx +++|* (T6) = TRACK. 00031 M00S00028.6dx +++|* (T7) = SECTOR. 00032 M00S00029.6dx +++| SPACE 4,10 00033 M00S00030.6dx +++|*CALL COMPMAC 00034 M00S00031.6dx +++|*CALL COMSDFS 00035 M00S00032.6dx +++|*CALL COMSMSP 00036 M00S00033.6dx +++|*CALL COMSPIM 00037 M00S00034.6dx +++| SPACE 4,10 00038 M00S00035.6dx +++|* ASSEMBLY CONSTANTS. 00039 M00S00036.6dx +++| 00040 M00S00037.6dx +++| 00041 M00S00038.6dx +++| DEC MICRO 1,, 6DX DECK NAME 00042 M00S00039.6dx +++| EJECT 00043 M00S00040.6dx +++|** ENTRY POINT TRANSFERS. 00044 M00S00041.6dx +++| 00045 M00S00042.6dx +++| 00046 M00S00043.6dx +++| ORG MSFW 00047 M00S00044.6dx +++| 00048 M00S00045.6dx +++| CON PRS PRESET ADDRESS 00049 M00S00046.6dx +++| 00050 M00S00047.6dx +++| 00051 M00S00048.6dx +++| RDS CON 0 ENTRY 00052 M00S00049.6dx +++| UJN RDS. ENTER DRIVER 00053 M00S00050.6dx +++| 00054 M00S00051.6dx +++| 00055 M00S00052.6dx +++| WDS CON 0 ENTRY 00056 M00S00053.6dx +++| UJN WDS. ENTER DRIVER 00057 M00S00054.6dx +++| EMS SPACE 4,10 00058 M00S00055.6dx +++|** EMS - END MASS STORAGE OPERATION. 00059 M00S00056.6dx +++|* 00060 M00S00057.6dx +++|* EXIT (A) = 0.
Line S00003 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00061 M01S00003.252l678 +++|* (UEMG) = EM SHIFT FOR CALCULATING HEADER ADDRESS. 00062 M01S00004.252l678 +++|* (UEMH) = EM SHIFT FOR CALCULATING EM ADDRESS. 00063 M00S00058.6dx +++| 00064 M00S00059.6dx +++| 00065 M00S00060.6dx +++| .EMS SUBR ENTRY/EXIT 00066 M00S00061.6dx +++| LDN 0 00067 M00S00062.6dx +++| STM CHRV 00068 M00S00063.6dx +++| UJN .EMSX RETURN 00069 M00S00064.6dx +++| RDS SPACE 4,10 00070 M00S00065.6dx +++|** RDS - READ SECTOR. 00071 M00S00066.6dx +++|* 00072 M00S00067.6dx +++|* ENTRY (A) = BUFFER ADDRESS FOR SECTOR. 00073 M00S00068.6dx +++|* 00074 M00S00069.6dx +++|* EXIT (A) = 0 IF TRANSFER COMPLETE. 00075 M00S00070.6dx +++|* = ERROR CODE IF ERROR OCCURRED. 00076 M00S00071.6dx +++|* 00077 M00S00072.6dx +++|* CALLS UEM. 00078 M00S00073.6dx +++| 00079 M00S00074.6dx +++| 00080 M00S00075.6dx +++| RDS. LPC 7777 00081 M00S00076.6dx +++| UJN UEM SET BUFFER ADDRESSES 00082 M00S00077.6dx +++| WDS SPACE 4,10 00083 M00S00078.6dx +++|** WDS - WRITE SECTOR. 00084 M00S00079.6dx +++|* 00085 M00S00080.6dx +++|* ENTRY (A) = BUFFER ADDRESS FOR SECTOR. 00086 M00S00081.6dx +++|* 00087 M00S00082.6dx +++|* EXIT (A) = 0 IF TRANSFER COMPLETE. 00088 M00S00083.6dx +++|* = ERROR CODE IF ERROR OCCURRED. 00089 M00S00084.6dx +++|* 00090 M00S00085.6dx +++|* CALLS UEM. 00091 M00S00086.6dx +++| 00092 M00S00087.6dx +++| 00093 M00S00088.6dx +++| WDS. LPC 7777 00094 M00S00089.6dx +++| LMC 1S15 00095 M00S00090.6dx +++|* UJN UEM SET BUFFER ADDRESSES 00096 M00S00091.6dx +++| UEM SPACE 4,15 00097 M00S00092.6dx +++|** UEM - UEM TRANSFER. 00098 M00S00093.6dx +++|* 00099 M00S00094.6dx +++|* ENTRY (A) = 3/ O,3/,12/ BUFFER ADDRESS. 00100 M00S00095.6dx +++|* O = 0 FOR READ REQUEST. 00101 M00S00096.6dx +++|* = 1 FOR WRITE REQUEST.
Line S00005 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00102 M01S00005.252l678 +++|* (UEMG) = EM SHIFT FOR CALCULATING HEADER ADDRESS. 00103 M01S00006.252l678 +++|* (UEMH) = EM SHIFT FOR CALCULATING EM ADDRESS. 00104 M00S00097.6dx +++|* 00105 M00S00098.6dx +++|* EXIT (A) .LT. 0, IF UNRECOVERED ERROR. 00106 M00S00099.6dx +++|* 00107 M00S00100.6dx +++|* MACROS MSERR. 00108 M00S00101.6dx +++| 00109 M00S00102.6dx +++| 00110 M00S00103.6dx +++| UEM STM UEMD SET BUFFER ADDRESS FOR HEADER 00111 M00S00104.6dx +++| ADN 2 00112 M00S00105.6dx +++| STM UEME 00113 M00S00106.6dx +++| SHN -17 SAVE READ/WRITE FLAG FOR *7DX* 00114 M00S00107.6dx +++| STI D1 00115 M00S00108.6dx +++| SHN 1 SET RETURN INDEX 00116 M00S00109.6dx +++| STD CM 00117 M00S00110.6dx +++| ERRNZ RDS+2-WDS CODE DEPENDS ON VALUE 00118 M00S00111.6dx +++| SHN 7-1 SET READ / WRITE INSTRUCTIONS 00119 M00S00112.6dx +++| LMC CRMI+ON 00120 M00S00113.6dx +++| STM UEMD-1 00121 M00S00114.6dx +++| LMN HN&ON 00122 M00S00115.6dx +++| STM UEME-1 00123 M00S00116.6dx +++| LDM RDS,CM SET RETURN ADDRESS 00124 M00S00117.6dx +++| STM UEMF
Line S00118 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00125 M01S00118.252l678 ---| LDD T6 HEADER ADDRESS = TRACK * 2020 + SECTOR 00126 M01S00119.252l678 ---| LPC 3777 00127 M01S00120.252l678 ---| SHN 4 00128 M01S00121.252l678 ---| STD CM+1 00129 M01S00122.252l678 ---| SHN -6 00130 M01S00123.252l678 ---| STD CM 00131 M01S00124.252l678 ---| SHN -6 00132 M01S00125.252l678 ---| RAD CM 00133 M00S00126.6dx +++| LDC ** LARGEST TRACK VALUE 00134 M00S00127.6dx +++| UEMA EQU *-1 00135 M00S00128.6dx +++| SBD T6 00136 M00S00129.6dx +++| MJN UEM1 IF TRACK TOO LARGE
Line S00130 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00137 M01S00130.252l678 ---| LDN SLDP 00138 M01S00131.252l678 ---| SBD T7 00139 M01S00132.252l678 ---| PJN UEM2 IF SECTOR OK
Line S00007 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00140 M01S00007.252l678 +++| LDD T7 00141 M01S00008.252l678 +++| SBM SLM 00142 M01S00009.252l678 +++| MJN UEM2 IF SECTOR OKAY 00143 M00S00133.6dx +++| 00144 M00S00134.6dx +++|* INVALID MASS STORAGE ADDRESS. 00145 M00S00135.6dx +++| 00146 M00S00136.6dx +++| UEM1 LDN ADDE SET ADDRESS ERROR 00147 M00S00137.6dx +++| STM ERRA 00148 M00S00138.6dx +++| MSERR 7DX CALL *7DX* ERROR PROCESSOR 00149 M00S00139.6dx +++| 00150 M00S00140.6dx +++|* VALID MASS STORAGE ADDRESS. 00151 M00S00141.6dx +++|
Line S00142 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00152 M01S00142.252l678 ---| UEM2 LDD CM+1 00153 M01S00143.252l678 ---| LPN 77 00154 M01S00144.252l678 ---| SHN 6 00155 M01S00145.252l678 ---| ADD T7 00156 M01S00146.252l678 ---| RAD CM+1 00157 M01S00147.252l678 ---| SHN -14 00158 M01S00148.252l678 ---| RAD CM
Line S00010 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00159 M01S00010.252l678 +++| UEM2 LDD T6 HEADER ADDRESS = TRACK*101B*SLDE+SECTOR 00160 M01S00011.252l678 +++| LPC 3777 00161 M01S00012.252l678 +++| SHN 1 00162 M01S00013.252l678 +++| STD CM+1 00163 M01S00014.252l678 +++| SHN 6 00164 M01S00015.252l678 +++| RAD CM+1 00165 M01S00016.252l678 +++| SHN -14 00166 M01S00017.252l678 +++| UEMG SHN 4-1 00167 M01S00018.252l678 +++|* SHN 4-1+EMTS (EMTS = TRACK SHIFT) 00168 M01S00019.252l678 +++| STD CM 00169 M01S00020.252l678 +++| LDD CM+1 00170 M01S00021.252l678 +++| UEMH SHN 4-1 00171 M01S00022.252l678 +++|* SHN 4-1+EMTS (EMTS = TRACK SHIFT) 00172 M01S00023.252l678 +++| LMD T7 ADD SECTOR NUMBER 00173 M01S00024.252l678 +++| STD CM+1 00174 M01S00025.252l678 +++| SHN -14 00175 M01S00026.252l678 +++| RAD CM 00176 M00S00149.6dx +++| LDC 0 CM ADDR = HEADER ADDR + UEM BASE ADDR 00177 M00S00150.6dx +++| UEMB EQU *-1 00178 M00S00151.6dx +++| RAD CM+1 00179 M00S00152.6dx +++| SHN -14 00180 M00S00153.6dx +++| ADC 0 00181 M00S00154.6dx +++| UEMC EQU *-1 00182 M00S00155.6dx +++| RAD CM 00183 M00S00156.6dx +++| SRD CM+2 SAVE R-REGISTER
Line S00157 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00184 M01S00157.252l678 ---| LDD CM+1 PUT UPPER 15 ADDR BITS IN R-REGISTER
Line S00027 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00185 M01S00027.252l678 +++| LDD CM+1 PUT UPPER 18 ADDR BITS IN R-REGISTER 00186 M00S00158.6dx +++| SCN 77 00187 M00S00159.6dx +++| SHN 6 00188 M00S00160.6dx +++| LMD CM 00189 M00S00161.6dx +++| SHN 6 00190 M00S00162.6dx +++| STD T2 00191 M00S00163.6dx +++| SHN -14 00192 M00S00164.6dx +++| STD T1 00193 M00S00165.6dx +++| LRD T1 00194 M00S00166.6dx +++| LDD CM+1 PUT LOWER 6 ADDR BITS IN A-REGISTER 00195 M00S00167.6dx +++| LPN 77 00196 M00S00168.6dx +++| STD CM+1 00197 M00S00169.6dx +++| LMC 400000 00198 M00S00170.6dx +++| CRM *,ON READ/WRITE HEADER 00199 M00S00171.6dx +++| UEMD EQU *-1
Line S00172 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00200 M01S00172.252l678 ---| LDD T7 DATA ADDRESS = HEADER + 20 + 77 * SECTOR
Line S00028 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00201 M01S00028.252l678 +++| LDD T7 DATA ADDRESS = HEADER + SLDE +77 * SECTOR 00202 M00S00173.6dx +++| SHN 6 00203 M00S00174.6dx +++| SBD T7
Line S00175 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00204 M01S00175.252l678 ---| ADN SLDP
Line S00029 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00205 M01S00029.252l678 +++| ADM SLM 00206 M00S00176.6dx +++| ADD CM+1 00207 M00S00177.6dx +++| LMC 400000 00208 M00S00178.6dx +++| CRM *,HN READ/WRITE DATA 00209 M00S00179.6dx +++| UEME EQU *-1 00210 M00S00180.6dx +++| LRD CM+2 RESTORE R-REGISTER 00211 M00S00181.6dx +++| LDN 0 INDICATE NO ERRORS 00212 M00S00182.6dx +++| STM CHRV 00213 M00S00183.6dx +++| UEM3 LJM * RETURN 00214 M00S00184.6dx +++| UEMF EQU *-1 00215 M00S00185.6dx +++| PRS SPACE 4,10 00216 M00S00186.6dx +++|** PRS - PRESET. 00217 M00S00187.6dx +++|* 00218 M00S00188.6dx +++|* ENTRY (CM - CM+4) = EST ENTRY. 00219 M00S00189.6dx +++| 00220 M00S00190.6dx +++|
Line S00191 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00221 M01S00191.252l678 ---| PRS LDC UEML GET UEM BASE ADDRESS
Line S00030 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00222 M01S00030.252l678 +++| PRS LDK MEFL SET EM SHIFT 00223 M01S00031.252l678 +++| CRM PRSA,ON 00224 M01S00032.252l678 +++| LDM PRSA+2 00225 M01S00033.252l678 +++| SHN -5 00226 M01S00034.252l678 +++| LPN 3 00227 M01S00035.252l678 +++| ADC SHNI+4-1 00228 M01S00036.252l678 +++| STM UEMG UPDATE SHIFT INSTRUCTIONS 00229 M01S00037.252l678 +++| STM UEMH 00230 M01S00038.252l678 +++| LDC UEML GET UEM BASE ADDRESS 00231 M00S00192.6dx +++| CRM PRSA,ON 00232 M00S00193.6dx +++| LDM PRSA
Line S00194 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00233 M01S00194.252l678 ---| SHN 21-2+UESF
Line S00039 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00234 M01S00039.252l678 +++| SHN 21-2 00235 M00S00195.6dx +++| STM UEMC 00236 M00S00196.6dx +++| SHN 13-21 00237 M00S00197.6dx +++| SCN 77 00238 M00S00198.6dx +++| STM UEMB 00239 M00S00199.6dx +++| LDD CM+4 SET LARGEST TRACK 00240 M00S00200.6dx +++| SHN 3 00241 M00S00201.6dx +++| ADK TDGL 00242 M00S00202.6dx +++| CRM PRSA,ON 00243 M00S00203.6dx +++| SOM PRSA 00244 M00S00204.6dx +++| ADC 4000 00245 M00S00205.6dx +++| STM UEMA 00246 M00S00206.6dx +++| LJM SMSX RETURN 00247 M00S00207.6dx +++| 00248 M00S00208.6dx +++| PRSA BSS 0 FIVE BYTES FOR READING LARGEST TRACK
Line S00209 Modification History | |
---|---|
M01 (Removed by) | ns2352 |
Seq # *Modification Id* Act ----------------------------+ 00249 M01S00209.ns2352 ---| ERRNG PPFW-5-*-5 OVERFLOW OF PRSA
Line S00001 Modification History | |
---|---|
M01 (Added by) | ns2352 |
Seq # *Modification Id* Act ----------------------------+ 00250 M01S00001.ns2352 +++| .1 SET *+5+4-MSFW CHECK FOR OVERFLOW 00251 M01S00002.ns2352 +++| .1 SET .1/5 00252 M01S00003.ns2352 +++| .1 SET MSFW+.1*5 00253 M01S00004.ns2352 +++| .2 SET PPFW-5-*-5 BYTES AVAILABLE BEFORE OVERFLOW 00254 M01S00005.ns2352 +++| ERRNG PPFW-5-.1 DRIVER OVERFLOWS INTO *PPFW*-5
Line S00210 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00255 M01S00210.252l678 ---| 7DX MSOVL 7714,T2,EPFW-1,(UEM ERROR PROCESSOR.)
Line S00040 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00256 M01S00040.252l678 +++| 7DX MSOVL 7702,T2,EPFW-1,(UEM ERROR PROCESSOR.) 00257 M00S00211.6dx +++| SPACE 4,10 00258 M00S00212.6dx +++|***** 7DX - UEM ERROR PROCESSOR. 00259 M00S00213.6dx +++|* C. B. LOSCHEIDER. 81/03/04. 00260 M00S00214.6dx +++| SPACE 4,10 00261 M00S00215.6dx +++|*** *7DX* IS CALLED WHEN AN UNRECOVERABLE UEM ABORT 00262 M00S00216.6dx +++|* HAS OCCURRED. THE ONLY ERROR WHICH MAY OCCUR 00263 M00S00217.6dx +++|* IS AN ADDRESSING ERROR. 00264 M00S00218.6dx +++| SPACE 4,10 00265 M00S00219.6dx +++| QUAL 00266 M00S00220.6dx +++| BEGIN BSSN PRS 00267 M00S00221.6dx +++| ERRA BSSN 1 ERROR FLAG WORD 00268 M00S00222.6dx +++| ERRNG DEFW-* *7DX*/COMMON ERROR PROCESSOR CONFLICT 00269 M00S00223.6dx +++| END BSSN 00270 M00S00224.6dx +++| QUAL * 00271 M00S00225.6dx +++| MSE SPACE 4,25 00272 M00S00226.6dx +++|** MSE - MASS STORAGE ERROR PROCESSOR. 00273 M00S00227.6dx +++|* 00274 M00S00228.6dx +++|* ENTRY ((D1)) = 0 IF READ, 1 IF WRITE. 00275 M00S00229.6dx +++|* (UEMD) = PP BUFFER ADDRESS OF HEADER. 00276 M00S00230.6dx +++|* (ERRA) = ERROR CODE AS DEFINED IN *COMSMSP*. 00277 M00S00231.6dx +++|* (T1) = UEMD. 00278 M00S00232.6dx +++|* (T2) = ERRA. 00279 M00S00233.6dx +++|* (T5) = EQUIPMENT. 00280 M00S00234.6dx +++|* (T6) = LOGICAL TRACK. 00281 M00S00235.6dx +++|* (T7) = LOGICAL SECTOR. 00282 M00S00236.6dx +++|*
Line S00237 Modification History | |
---|---|
M01 (Removed by) | ns2741 |
Seq # *Modification Id* Act ----------------------------+ 00283 M01S00237.ns2741 ---|* EXIT (T2) = READ BUFFER ADDRESS FOR *7EL*.
Line S00001 Modification History | |
---|---|
M01 (Added by) | ns2741 |
Seq # *Modification Id* Act ----------------------------+ 00284 M01S00001.ns2741 +++|* EXIT (T2) = READ BUFFER ADDRESS FOR *7EK*. 00285 M00S00238.6dx +++|* (DEDT) = 8/0, 4/*6DX* DRIVER TYPE. 00286 M00S00239.6dx +++|* (DEEC) = ERROR CODE. 00287 M00S00240.6dx +++|* (DENR) = 0. 00288 M00S00241.6dx +++|* (DERC) = 0. 00289 M00S00242.6dx +++|* (DERW) = 1 IF WRITE REQUEST, 0 IF READ REQUEST. 00290 M00S00243.6dx +++|* (DEST) = 0. 00291 M00S00244.6dx +++|* (DEWR) = 0.
Line S00245 Modification History | |
---|---|
M01 (Removed by) | 253l688 |
Seq # *Modification Id* Act ----------------------------+ 00292 M01S00245.253l688 ---|* (RDCT) = 7/0, 1/1, 4/0.
Line S00001 Modification History | |
---|---|
M01 (Added by) | 253l688 |
Seq # *Modification Id* Act ----------------------------+ 00293 M01S00001.253l688 +++|* (RDCT) = 5/0, 1/1, 6/0. 00294 M00S00246.6dx +++|* (MB+2) = DRIVER DEPENDENT PART OF BML MESSAGE. 00295 M00S00247.6dx +++|* 24/0, 12/W, 24/A. 00296 M00S00248.6dx +++|* W = WORD COUNT. 00297 M00S00249.6dx +++|* A = EXTENDED MEMORY ERROR ADDRESS. 00298 M00S00250.6dx +++|* 00299 M00S00251.6dx +++|* USES T2, CM - CM+4. 00300 M00S00252.6dx +++|* 00301 M00S00253.6dx +++|* MACROS MSERR. 00302 M00S00254.6dx +++| 00303 M00S00255.6dx +++| 00304 M00S00256.6dx +++| DDX ENTRY *7DX* ENTRY 00305 M00S00257.6dx +++| 00306 M00S00258.6dx +++| LDI D1 SET READ/WRITE FLAG 00307 M00S00259.6dx +++| STM DERW 00308 M00S00260.6dx +++| LDK /COMSDFS/D6DX SAVE DRIVER TYPE 00309 M00S00261.6dx +++| STM DEDT
Line S00262 Modification History | |
---|---|
M01 (Removed by) | 253l688 |
Seq # *Modification Id* Act ----------------------------+ 00310 M01S00262.253l688 ---| LDN 20 SET *RECOVERY IN PROGRESS* FLAG
Line S00002 Modification History | |
---|---|
M01 (Added by) | 253l688 |
Seq # *Modification Id* Act ----------------------------+ 00311 M01S00002.253l688 +++| LDD HN SET RECOVERY IN PROGRESS FLAG 00312 M00S00263.6dx +++| STM RDCT 00313 M00S00264.6dx +++| LDI T2 SET ERROR CODE 00314 M00S00265.6dx +++| STM DEEC
Line S00266 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00315 M01S00266.252l678 ---| LDD T6 HEADER ADDRESS = TRACK * 2020B + SECTOR
Line S00041 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00316 M01S00041.252l678 +++| LDK MEFL 00317 M01S00042.252l678 +++| CRD CM 00318 M01S00043.252l678 +++| LDD CM+2 00319 M01S00044.252l678 +++| SHN -5 00320 M01S00045.252l678 +++| LPN 3 00321 M01S00046.252l678 +++| RAM DDXA 00322 M01S00047.252l678 +++| LDD T6 HEADER ADDRESS = TRACK*101B*SLDE+SECTOR 00323 M00S00267.6dx +++| LPC 3777
Line S00268 Modification History | |
---|---|
M01 (Removed by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00324 M01S00268.252l678 ---| SHN 4
Line S00048 Modification History | |
---|---|
M01 (Added by) | 252l678 |
Seq # *Modification Id* Act ----------------------------+ 00325 M01S00048.252l678 +++| DDXA SHN 4 00326 M01S00049.252l678 +++|* SHN 4+EMTS (EMTS = TRACK SHIFT) 00327 M00S00269.6dx +++| STD CM+4 00328 M00S00270.6dx +++| SHN -6 00329 M00S00271.6dx +++| STD CM+3 00330 M00S00272.6dx +++| SHN -6 00331 M00S00273.6dx +++| RAD CM+3 00332 M00S00274.6dx +++| LDD CM+4 00333 M00S00275.6dx +++| LPN 77 00334 M00S00276.6dx +++| SHN 6 00335 M00S00277.6dx +++| ADD T7 00336 M00S00278.6dx +++| RAD CM+4 00337 M00S00279.6dx +++| SHN -14 00338 M00S00280.6dx +++| RAD CM+3 00339 M00S00281.6dx +++| LDN 1 SAVE WORD COUNT FOR BML MESSAGE 00340 M00S00282.6dx +++| STD CM+2 00341 M00S00283.6dx +++| LDN 0 CLEAR UNUSED FIELDS IN BML MESSAGE 00342 M00S00284.6dx +++| STD CM+1 00343 M00S00285.6dx +++| STD CM 00344 M00S00286.6dx +++| STM DENR INITIALIZE *NON-RECOVERABLE ERROR* FLAG 00345 M00S00287.6dx +++| STM DERC INITIALIZE RETRY COUNT 00346 M00S00288.6dx +++| STM DEST INITIALIZE ERROR PROCESSING CONTROL WORD 00347 M00S00289.6dx +++| ERRNZ RTC.AD *7DX* ASSUMES NO RETRY WILL BE ATTEMPTED 00348 M00S00290.6dx +++| STM DEWR INITIALIZE *DATA WRITTEN/READ* FLAG 00349 M00S00291.6dx +++| LDI T1 SET ADDRESS OF BUFFER HEADER 00350 M00S00292.6dx +++| STD T2 00351 M00S00293.6dx +++| LDD MA SAVE DEPENDENT PART OF BML MESSAGE 00352 M00S00294.6dx +++| ADN 2 00353 M00S00295.6dx +++| CWD CM
Line S00296 Modification History | |
---|---|
M01 (Removed by) | ns2741 |
Seq # *Modification Id* Act ----------------------------+ 00354 M01S00296.ns2741 ---| MSERR 7EL EXECUTE *7EL*
Line S00002 Modification History | |
---|---|
M01 (Added by) | ns2741 |
Seq # *Modification Id* Act ----------------------------+ 00355 M01S00002.ns2741 +++| MSERR 7EK EXECUTE *7EK* 00356 M00S00297.6dx +++| 00357 M00S00298.6dx +++| 00358 M00S00299.6dx +++| ERRNG 10000-* *7DX* HAS OVERFLOWED 00359 M00S00300.6dx +++| BSS 10000-* SPARES (ADJUST ORIGIN BY 5 AS REQUIRED) 00360 M00S00301.6dx +++| CON DDX-1 (T0) = ENTRY ADDRESS - 1 00361 M00S00302.6dx +++| CON UEMD (T1) = BUFFER HEADER ADDRESS 00362 M00S00303.6dx +++| CON ERRA (T2) = ADDRESS OF WORD CONTAINING 00363 M00S00304.6dx +++| ERROR FLAG 00364 M00S00305.6dx +++| ERRNZ LN-* ILLEGAL PROGRAM LENGTH 00365 M00S00306.6dx +++| QUAL * 00366 M00S00307.6dx +++| END
cdc/nos2.source/opl.opl871/deck/6dx.txt ยท Last modified: by 127.0.0.1