User Tools

Site Tools


cdc:nos2:installed.users

Installed Users

Courtesy: William Schaub

After a successful installation of all optional software, it's useful to have a list of the default configuration of users as a result:

Username User Index octal Password Created By Interactive Facility Allowed? Batch Submissions Allowed?

Purpose / Description

APL0 3 APL0 SYSGEN RDF only yes

CDC APL 2 product installation files

APL1 4 APL1 SYSGEN RDF only yes

CDC APL 2 product installation files

APLLIB 377774 SYSGEN no no

CDC APL 2 product installation files

A0126 may vary A0126 NCC yes yes

Provides Sample content for the Query Update 3 Users guide
It’s installed as part of query update 3

CDCCE 6 CDCCE SYSGEN RDF only yes

Concurrent Maintenance Library

CDCCE2 7 CDCCE2 SYSGEN RDF only yes

Concurrent Maintenance Library.

CDCS may vary CDCS NCC yes yes

CDCS 2 product installation from the NCC automation framework.
We create a working base config for CDCS to build future examples ontop of.
This is created by cdcs2-users.job

CYBIS 33 CYBIS SYSGEN RDF only yes

added by the CDC default install but we use PLATO
Instead.

CYBISMF 377773 CYBISMF SYSGEN no no

added by CDC default install, we use PLATOMF
Instead.

DBCNTLX may vary DBCNTLX NCC yes yes

CDCS 2 product installation from the NCC automation framework.
We create a working base config for CDCS to build future examples ontop of.
This is created by cdcs2-users.job

FLAWPF 377775 unknown SYSGEN no no

PF utilities use this account to catalog
Indirect access file chains that contain sections with
Mass storage errors in them to prevent them from
Being re-cataloged someplace else. See deck
PFLOAD

GUEST may vary GUEST NCC yes yes

guest user account added by automation framework

INSTALL 1 INSTALL SYSGEN yes yes

user that owns the NOS build/source files
For both NOS and the common product set.

KB100DC 16 TAFPASS SYSGEN RDF only yes

TAF subsystem user (transaction facility, think
CICS for NOS)

LIBRARY 377776 LIBRARY SYSGEN no no

user for cataloging files under an easily known UN

MANUALS 2 MANUALS SYSGEN yes yes

Online manuals maintenance account
EXPLAIN and REVIEW find online manuals
In this account, it’s a lot like GNU info
This account has a procedure for loading online manuals
And it set to allow interactive login to facilitate editing
And loading manuals onto the system, etc.

NETADMN 25 NETADMN SYSGEN yes yes

NDL and TCPHOST live here, network administrator
Most CDCNET config lives here too but we don’t
Emulate the stuff that uses it, NPU load file lives here
But we don’t really use that either in dtcyber.

NETOPS 377772 NETOPSX SYSGEN no no

NAM subsystem files live here, most well known being
NAMSTRT. The rest are things like trace files,
Accounting, etc used exclusively by NAM and friends.

NVE 26 NVEX SYSGEN yes yes

NOS/VE user account, I think it has something to
Do with maintaining the NOS/VE sources and/or a
Way to gain access to VEIAF to access NOS/VE from
Inside NOS. Hopefully one day it will have a use.
It is validated to use VEIAF so I assume that’s
Its main purpose.

PLATO 33 PLATO NCC yes yes

contains PLATO development system source files.

PLATOMF 377773 PLATOMF NCC no no

contains PLATO master files.

PRINTS 30 PRINTS NCC yes yes

PLATO account for handling lesson prints
All print jobs are submitted to this user
I’m unsure if the password being changed will break it

PRINT01 10 PRINT01 SYSGEN can login, forced into
PSU.
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT02 11 PRINT02 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT03 12 PRINT03 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT04 13 PRINT04 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT05 14 PRINT05 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT06 15 PRINT06 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT07 17 PRINT07 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT08 20 PRINT08 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT09 21 PRINT09 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT10 22 PRINT10 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT11 23 PRINT11 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

PRINT12 24 PRINT12 SYSGEN can login, forced into
PSU
yes

Printer Support Utility user for remote printer
See installation handbook for details

RJE1 may vary RJE1 NCC RDF: yes, RBF forced on other ports. yes

Installed as part of the remote batch facility. (HASP RJE station support)
This user is forced to automatically be associated with the HASP port when a connection comes in.
It should be safe to change this password without breaking things.

RJE2 may vary RJE2 NCC RDF: yes, RBF forced on other ports. yes

Installed as part of the remote batch facility. (HASP RJE station support)
This user is forced to automatically be associated with the HASP port when a connection comes in.
It should be safe to change this password without breaking things.

SES 32 SESX NCC yes yes

SES Tools permanent files/management.

SSPOT 5 STATION SYSGEN RDF only yes

NOS2 SCOPE Station facility user

SUBFAM0 377760 SUBFAM0 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM1 377761 SUBFAM1 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM2 377762 SUBFAM2 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM3 377763 SUBFAM3 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM4 377764 SUBFAM4 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM5 377765 SUBFAM5 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM6 377766 SUBFAM6 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SUBFAM7 377767 SUBFAM7 SYSGEN no no

NOS Mass Storage Extended subsystem user.
See installation handbook and analysis handbook
We don’t emulate the necessary bits for MSE but this
User account is reserved for it’s use, these accounts
Are used to stage files from IBM 3850 cartridges.

SYS 31 NCC yes yes

PLATO user used to submit batch jobs, see the PLATO
Manuals/source code for more details, I’m not sure the
Password matters, it seems to work fine with the
Password changed, on the original CYBIS kit it was
Passme.

This account probably has more priviliges than it needs, and
Likely ended up that way due to frustration trying to make PLATO
Happy.

SYSTEMX 377777 SYSTEMX SYSGEN no no

/etc equivalent for NOS.

WWW 100 WWWX NCC yes yes

web root for the HTTP daemon installed as part of the ncctcp product.

cdc/nos2/installed.users.txt · Last modified: 2023/08/05 15:34 by Site Administrator