- BSC TITLE 'DMKBSC (CP) VM/370 - RELEASE 6' 00001000
- ISEQ 73,80 VALIDATE INPUT SERIALIZATION @V2D3931 00002000
- COPY OPTIONS @V2D3931 00003000
- EJECT 00004000
- ************************************************************** 00005000
- *. 00006000
- * MODULE NAME - 00007000
- * 00008000
- * DMKBSC 00009000
- * 00010000
- * FUNCTION - 00011000
- * 00012000
- * TO EXAMINE THE ERROR CONDITION RESULTING FROM A UNIT CHECK 00013000
- * OR CHANNEL ERROR WHILE EXECUTING A CP GENERATED BISYNC 00014000
- * LINE CHANNEL PROGRAM. IF THE ERROR CONDITION IS 00015000
- * UNCORRECTABLE A CALL WILL BE ISSUED TO THE MESSAGE WRITER 00016000
- * (DMKMSW) FOR OPERATOR AWARENESS. ON REGAINING CONTROL FROM 00017000
- * DMKMSW THE ORIGINAL CHANNEL PROGRAM IS TERMINATED AND THE 00018000
- * FATAL FLAG IS SET IN THE IOBLOK. OTHERWISE, THE CHANNEL 00019000
- * PROGRAM IS RE-EXECUTED AGAIN, UP TO A MAXIMUN OF 7 RETRYS. 00020000
- * ALSO STATISTICAL DATA COUNTERS WILL BE UPDATED. 00020100
- * 00021000
- * ATTRIBUTES - 00022000
- * 00023000
- * SERIALLY REUSEABLE, RESIDENT, ENTERED VIA SVC 00024000
- * 00025000
- * ENTRY CONDITIONS - 00026000
- * 00027000
- * GR 13 = ADDRESS OF SAVE AREA 00028000
- * GR 12 = ADDRESS OF DMKBSCER 00029000
- * GR 11 = ADDRESS OF A VALID VMBLOK 00030000
- * GR 10 = ADDRESS OF IOBLOK 00031000
- * GR 8 = ADDRESS OF THE LINE RDEVBLOK 00032000
- * 00033000
- * EXIT CONDITIONS - 00034000
- * 00035000
- * 1. WHEN RETRY IS POSSIBLE: 00036000
- * IOBFLAG=IOBRSTRT 00037000
- * IOBRCAW=ADDRESS OF RESTART CCW STRING 00038000
- * 2. WHEN RETRY IS NOT POSSIBLE: 00039000
- * IOBFLAG=IOBFATAL 00040000
- * 00041000
- * CALLS TO OTHER ROUTINES - 00042000
- * 00043000
- * DMKMSWR - TO PROVIDE OPERATOR COMMUNICATION 00044000
- * DMKFREE - TO ALLOCATE FREE STORAGE FOR WORK AREA 00045000
- * DMKFRET - TO RELEASE STORAGE USED FOR WORK AREA 00046000
- * DMKIOEST - TO UPDATE STATISTICAL DATA COUNTERS 00046100
- * 00047000
- * EXTERNAL REFERENCES - 00048000
- * 00049000
- * NONE 00050000
- * 00051000
- * TABLES / WORK AREAS - 00052000
- * 00053000
- * NONE 00054000
- * 00055000
- * REGISTER USAGE - 00056000
- * 00057000
- * GR0-6 WORK REGISTERS 00058000
- * GR 7 = IOERBLOK ADDRESS 00059000
- * GR 8 = RDEVBLOK ADDRESS 00060000
- * GR 10 = IOBLOK ADDRESS 00061000
- * GR 11 = VMBLOK ADDRESS 00062000
- * GR 12 = MODULE BASE REGISTER 00063000
- * GR 13 = SAVE AREA ADDRESS 00064000
- * GR14-15 LINKAGE REGISTERS 00065000
- * 00066000
- * NOTES - 00067000
- * 00068000
- * NONE 00069000
- * 00070000
- * OPERATION - 00071000
- * 00072000
- * I. SETUP ADDRESSABILITY FOR THE BISYNC ERP 00073000
- * 00074000
- * 1. DETERMINE IF THIS IS THE FIRST TIME ENTERING BSC ERP 00075000
- * MODULE FOR THIS BISYNC LINE. 00076000
- * 00077000
- * A. IF RDEVIOER FIELD IS ZERO, SAVE THE IOERBLOK ADDRESS IN 00078000
- * RDEVIOER, CLEAR RETRY COUNT AND FLAGS TO ZERO (IOBRCNT) 00079000
- * AND GET STORAGE FOR THE RESTART CCWS USED BY ERP. 00080000
- * 00081000
- * 2. UPDATE THE RETRY COUNT BY ONE AND TEST FOR CHANNEL 00082000
- * ERROR IN THE ORIGINAL IOERBLOK CSW FIELD AND IN THE 00083000
- * CURRENT IOERBLOK CSW FIELD. IF CHANNEL ERROR IS INDICATED, 00084000
- * SEND ERROR MESSAGE TO SYSTEM OPERATOR IF IT'S NOT CHANNEL 00085000
- * DATA CHECK,SET IOBFATAL FLAG AND EXIT TO DMKIOS. IF 00086000
- * CHANNEL DATA CHECK IS INDICATED, RETRY THE OPERATION 00087000
- * SEVEN TIMES BEFORE INDICATING FATAL CONDITION. 00088000
- * 00089000
- * 3. IF THERE IS NOT A CURRENT IOERBLOK POINTER AFTER HANDLING 00090000
- * THE ORIGINAL IOERBLOK, ASSUME THE BISYNC LINE ERROR HAS 00091000
- * BEEN CORECTED AND RETURN TO DMKIOS. 00092000
- * 00093000
- * II. ANALYZE THE CSW FOR A CHANNEL CONDITION (MSG. NO. DMKBSC520) 00094000
- * 00095000
- * 1. FOR CHANNEL INTERFACE AND CONTROL CHECK, SEND ERROR MESSAGE 00096000
- * TO SYSTEM OPERATOR. 00097000
- * 00098000
- * 2. FOR CHANNEL DATA CHECK, RETRY THE OPERATION SEVEN TIMES 00099000
- * BEFORE INDICATING FATAL CONDITION AND SENDING A MESSAGE 00100000
- * TO THE SYSTEM OPERATOR. 00101000
- * 00102000
- * WRITE OPERATION - 00103000
- * . ANY WRITE EXECPT WRITE TEXT, RETRY THE FAILING CCW. 00104000
- * 00105000
- * READ OPERATION - 00106000
- * . FOR READ RESPONSE, GENERATE A CHANNEL PROGRAM TO 00107000
- * WRITE ENQ TO THE STATION AND TRANSFER CONTROL TO THE 00108000
- * FAILING READ CCW. 00109000
- * 00110000
- * . FOR READ TEXT OR DATA, GENERATE A CHANNEL PROGRAM TO 00111000
- * WRITE NAK TO THE STATION AND TRANSFER CONTROL TO THE 00112000
- * FAILING READ CCW. 00113000
- * 00114000
- * III. ANALYZE THE CSW FOR A UNIT CHECK CONDITION 00115000
- * 00116000
- * ACTION 1 00117000
- * 00118000
- * SEND ERROR MESSAGE TO SYSTEM OPERATOR AND INDICATE 00119000
- * FATAL CONDITION ON BISYNC LINE. 00120000
- * 00121000
- * ACTION 2 00122000
- * 00123000
- * HANDLE FAILING READ CCW 00124000
- * . FOR READ RESPONSE, GENERATE A CHANNEL PROGRAM TO WRITE 00125000
- * ENQ TO THE STATION AND TRANSFER CONTROL TO THE FAILING 00126000
- * READ CCW. 00127000
- * 00128000
- * . FOR READ TEXT OR DATA, GENERATE A CHANNEL PROGRAM TO WRITE 00129000
- * NAK TO THE STATION AND TRANSFER CONTROL TO THE FAILING 00130000
- * READ CCW. 00131000
- * 00132000
- * ACTION 3 00133000
- * 00134000
- * . RETRY FAILING CCW UNTIL RETRY COUNT REACHED 7 00135000
- * 00136000
- * . IF 3275 SWITCHED AND A TIMEOUT CONDITION OCCURS: 00136100
- * IF WRITE RESET CCW GO RETRY. 00136200
- * IF WRITE CONTINUE OR READ CONTINUE ISSUE ERROR MSG. 00136300
- * IF READ CCW RETRY THE OPERATION 7 TIMES. 00136400
- * 00136500
- * PRIORITY CONDITION STATUS BIT ACTION 00137000
- * ________ _________ __________ ______ 00138000
- * 00139000
- * 1 EQUIPMENT CHECK 3 ACTION 1 00140000
- * 2 LOST DATA 6 ACTION 2 00141000
- * 3 TIME OUT 7 ACTION 2 & 3 00142000
- * 4 INTERVENTION REQ. 1 ACTION 1 & 2 00143000
- * 5 BUS OUT CHECK 2 ACTION 3 00144000
- * 6 DATA CHECK 4 ACTION 2 00145000
- * 7 OVERRUN 5 ACTION 2 00146000
- * 8 COMMAND REJECT 0 ACTION 2 00147000
- * 00148000
- * IV. ANALYZE THE CSW FOR PROGRAM, PROTECTION & CHAINING CHECK 00149000
- * 00150000
- * . INDICATE FATAL CONDITION, SEND ERROR MESSAGE TO 00151000
- * SYSTEM OPERATOR AND RETURN CONTROL TO DMKIOS. 00152000
- * 00153000
- * V. WHEN THE RETRY PROCEDURE IS FINISHED (EITHER CORRECTED 00153100
- * OR UNCORRECTABLE) CALL DMKIOEST TO CAUSE STATISTICAL 00153200
- * DATA COUNTERS TO BE UPDATED.. 00153300
- SPACE 00153400
- * ERROR MESSAGES - 00154000
- * 00155000
- * DMKBSC500I LINE 'ADDR' CMD REJECT ... 00156000
- * DMKBSC501A LINE 'ADDR' INT REQ 00157000
- * DMKBSC502I LINE 'ADDR' BUSOUT CK ... 00158000
- * DMKBSC503I LINE 'ADDR' EQUIP CK ... 00159000
- * DMKBSC504I LINE 'ADDR' DATA CK ... 00160000
- * DMKBSC505I LINE 'ADDR' OVERRUN CK ... 00161000
- * DMKBSC516I LINE 'ADDR' BAD SENSE ... 00162000
- * DMKBSC517I LINE 'ADDR' NOT/KNOWN ... 00163000
- * DMKBSC520I LINE 'ADDR' CHAN ERROR ... 00164000
- * DMKBSC527I LINE 'ADDR' LOST DATA ... 00165000
- * DMKBSC528I LINE 'ADDR' TIMEOUT ... 00166000
- * 00167000
- ************************************************************** 00168000
- EJECT 00169000
- DMKBSC CSECT @V2D3931 00170000
- EXTRN DMKFREE,DMKFRET,DMKMSWR @V2D3931 00171000
- EXTRN DMKIOEST STATISTICAL COUNTER UPDATE @VA03757 00171100
- SPACE 1 00172000
- USING SAVEAREA,R13 @V2D3931 00173000
- USING PSA,R0 @V2D3931 00174000
- USING BSCBLOK,R2 SET UP ADDRESSABILITY FOR BSCBLOK@V2D3931 00175000
- USING ERPBSC,R6 SET UP ADDRESSABILITY FOR ERP CCW@V2D3931 00176000
- USING RDEVBLOK,R8 SETUP ADDRESSABILITY FOR RDEVBLOK@V2D3931 00177000
- USING IOBLOK,R10 SET UP ADDRESSABILITY FOR IOBLOK @V2D3931 00178000
- DC CL8'DMKBSC' @V2D3931 00179000
- DMKBSCER RELOC @V2D3931 00180000
- SWITCH MAKE SURE WE ARE ON THE IO PROCESSOR @V4075A0 00180100
- ICM R7,15,RDEVIOER GET THE FIRST IOERBLOK, IF ANY. @V2D3931 00181000
- BP NOTFIRST IF NONE THIS IS THE FIRST TIME IN@V2D3931 00182000
- L R7,IOBIOER LOAD IOERBLOK IN REG.7 @V2D3931 00183000
- USING IOERBLOK,R7 ESTABLISH ADDRESSABILTY. @V2D3931 00184000
- ST R7,RDEVIOER STORE ADDRESS IN RDEVBLOK. @V2D3931 00185000
- SR R3,R3 CLEAR REG.3 @V2D3931 00186000
- ST R3,IOBIOER CLEAR POINTER OF IOERBLOK @V2D3931 00187000
- STH R3,IOBRCNT ZERO IOBRCNT FOR FIRST TIME @V2D3931 00188000
- NI IOBSTAT,X'FF'-IOBFATAL INSURE BIT IS OFF. @V2D3931 00189000
- NI IOBFLAG,X'FF'-(IOBRSTRT+IOBERP) CLEAR FLAGS @V2D3931 00190000
- LTR R7,R7 IS THERE AN IOERBLOK POINTER @V2D3931 00191000
- BZ EXIT1 NO, RETURN TO IOS @V2D3931 00192000
- OI IOBFLAG,IOBERP SET ERP IN CONTROL. @V2D3931 00193000
- NI IOERFLG2,X'FF'-IOERMSW CLEAR MESSAGE WRITER FLAG@V2D3931 00194000
- NI IOERFLG3,X'FF'-IOERREAD RESET FLAG @VA03757 00194100
- LA R0,ERPSIZE GET SIZE OF WORK AREA @V2D3931 00195000
- CALL DMKFREE @V2D3931 00196000
- STH R0,IOERDW SAVE NUMBER OF DOUBLEWORDS @V2D3931 00197000
- ST R1,IOERLOC ALSO REMEMBER AT WHAT ADDRESS. @V2D3931 00198000
- LR R6,R1 GET WORK AREA POINTER @V2D3931 00199000
- XC 0(8*ERPSIZE,R1),0(R1) CLEAR THE WORK AREA @V2D3931 00200000
- NOTFIRST EQU * R7 WILL POINT TO FIRST IOERBLOK @V2D3931 00201000
- L R2,RDEVBSC GET ADDRESS OF BSC CONTROL BLOCK @V2D3931 00202000
- L R6,IOERLOC GET POINTER TO ERP CCW AREA @V2D3931 00203000
- SR R4,R4 CLEAR REG.4 @V2D3931 00204000
- LH R4,IOBRCNT LOAD ERROR COUNT. @V2D3931 00205000
- A R4,F1 UPDATE RETRY COUNT BY ONE @V2D3931 00206000
- STH R4,IOBRCNT STORE RESULT IN IOBRCNT. @V2D3931 00207000
- L R3,IOBIOER GET ADDRESS OF SECOND IOERBLOK @V2D3931 00208000
- TM IOERCSW+5,IFCC+CCC IS THIS A CHANNEL ERROR @V2D3931 00209000
- BNZ CHANICC YES, GO HANDLE CHANNEL ERROR @V2D3931 00210000
- LTR R3,R3 IS THERE A SECOND IOERBLOK ? @V2D3931 00211000
- BZ RGACOUNT NO, CONTINUE PROCESSING @V2D3931 00212000
- TM IOERCSW+5-IOERBLOK(R3),IFCC+CCC IS CHANNEL ERROR@V2D3931 00213000
- BNZ CHANICC YES, GO HANDLE CHANNEL ERROR @V2D3931 00214000
- SPACE 1 00215000
- RGACOUNT EQU * PROCESS ERROR CONDITION @V2D3931 00216000
- TM IOERFLG2,IOERMSW IS MESSAGE WRITER IN CONTROL ? @V2D3931 00217000
- BZ CONTIN NO, CONTINUE PROCESSING ERROR @V2D3931 00218000
- BAL R5,FRETIOER RELEASE THE IOERBLOK @V2D3931 00219000
- NI IOBFLAG,X'FF'-IOBRSTRT CLEAR RESTART FLAG @V2D3931 00220000
- EXIT RETURN TO IOS @V2D3931 00221000
- SPACE 1 00222000
- CONTIN EQU * ANALYZE CSW FOR ERROR CONDITION @V2D3931 00223000
- CLC IOBRCNT,F1+2 IS THIS THE FIRST ERROR CONDITION@V2D3931 00224000
- BNE *+6 BYPASS SWITCHING REGISTERS @V2D3931 00225000
- LR R3,R7 GET ADDR. OF IOERBLOK IN REG3 @V2D3931 00226000
- LTR R3,R3 DID OPERATION FINISH CORRECTLY ? @V2D3931 00227000
- BZ CORRECT YES, GO RETURN TO IOS @V2D3931 00228000
- TM IOERCSW+5-IOERBLOK(R3),CDC IS CHAN. DATA CHECK @V2D3931 00229000
- BO BADCHAN YES, CHECK RETRY COUNT @V2D3931 00230000
- TM IOERCSW+4-IOERBLOK(R3),UC IS THIS A UNIT CHECK @V2D3931 00231000
- BO UNITCK YES, GO HANDLE UNIT CHECK @V2D3931 00232000
- CHANPRG EQU * HANDLE MESSAGE FOR CHAN. CHECKS @V2D3931 00233000
- MVI IOERNUM,CHANERR INDICATE CHANNEL ERROR MESSAGE @V2D3931 00234000
- BAL R5,FRETPTR RELEASE WORK AREA @V2D3931 00235000
- TM IOERCSW+5-IOERBLOK(R3),PRGC+PRTC+CHC IS STATUS @V2D3931 00236000
- BNZ CALLWTR1 YES, GO WRITE ERROR MESSAGE @V2D3931 00237000
- MVI IOERNUM,FALSE INDICATE INVALID SENSE MESSAGE @V2D3931 00238000
- B CALLWTR1 GO WRITE ERROR MESSAGE @V2D3931 00239000
- BADCHAN EQU * HANDLE CHANNEL DATA CHECK @V2D3931 00240000
- CLC IOBRCNT,F7+2 IS COUNT GREATER THAN 7 @V2D3931 00241000
- BH CHANICC YES, INDICATE CHANNEL ERROR MSG. @V2D3931 00242000
- BAL R5,GETCUCCW GET FAILING CCW ADDRESS @V2D3931 00243000
- BAL R5,READSUB GO HANDLE FAILING READ CCW @V2D3931 00244000
- B WRITE GO TO WRITE SECTION @V2D3931 00245000
- CHANICC EQU * HANDLE CHANNEL ERROR MESSAGE @V2D3931 00246000
- MVI IOERNUM,CHANERR INDICATE CHANNEL ERROR MESSAGE @V2D3931 00247000
- BAL R5,FRETPTR RELEASE WORK AREA @V2D3931 00248000
- L R3,IOBIOER IS THERE A SECOND IOERBLOK @V2D3931 00249000
- LTR R3,R3 IS THERE ONE ? @V2D3931 00250000
- BZ CALLWTR1 NO, GO WRITE ERROR MESSAGE @V2D3931 00251000
- TM IOERCSW+5,CDC+CCC+IFCC IS THIS A CHANNEL ERROR @V2D3931 00252000
- BNZ CALLWTR1 YES, GO WRITE ERROR MESSAGE @V2D3931 00253000
- ST R3,RDEVIOER SAVE CHANNEL IOERBLOK POINTER @V2D3931 00254000
- ST R7,IOBIOER SAVE ORIGINAL IOERBLOK ADDRESS @V2D3931 00255000
- LR R7,R3 GET CURRENT IOERBLOK @V2D3931 00256000
- MVI IOERNUM,CHANERR INDICATE CHANNEL ERROR MSG. @V2D3931 00257000
- B CALLWTR1 GO WRITE ERROR MESSAGE @V2D3931 00258000
- SPACE 1 00259000
- WRITE EQU * HANDLE WRITE OPERATION @V2D3931 00260000
- CLI 5(R4),X'0A' IS TEXT BEING TRANSFER @V2D3931 00261000
- BNE FAILCCW NO, GO RETRY FAILING CCW @V2D3931 00262000
- BAL R5,RESCOUN CHECK ON RESIDUAL COUNT @V2D3931 00263000
- B CHANICC GO WRITE CHANNEL ERROR MESSAGE @V2D3931 00264000
- SPACE 1 00265000
- UNITCK EQU * @V2D3931 00266000
- MVI IOERNUM,EQUIP INDICATE EQUIPMENT CHECK MSG @V2D3931 00267000
- TM IOERDATA,EQUI1 IS THIS AN EQUIPMENT CHECK @V2D3931 00268000
- BO CALLWTR1 YES, GO WRITE ERROR MESSAGE @V2D3931 00269000
- LOSTDAT EQU * HANDLE LOST DATA CONDITION @V2D3931 00270000
- BAL R5,GETCUCCW GET THE FAILING CCW @V2D3931 00271000
- MVI IOERNUM,LOST INDICATE LOST DATA MESSAGE @V2D3931 00272000
- TM IOERDATA,LDATA IS THIS A LOST DATA CONDITION @V2D3931 00273000
- BZ TIMEOUT NO, GO CHECK FOR TIMEOUT @V2D3931 00274000
- BAL R5,READSUB GO HANDLE FAILING READ CCW @V2D3931 00275000
- B CALLWTR1 IF WRITE CCW, GO WRITE MESSAGE @V2D3931 00276000
- ERPCCW EQU * @V2D3931 00277000
- CLI 5(R4),X'00' IS THIS AN ERP CCW @V2D3931 00278000
- BNE CALLWTR1 NO, GO WRITE ERROR MESSAGE @V2D3931 00279000
- B FAILCCW GO RETRY FAILING CCW @V2D3931 00280000
- TIMEOUT EQU * HANDLE TIMEOUT CONDITION @V2D3931 00281000
- MVI IOERNUM,TIMOUT SET TIMEOUT ERROR MESSAGE FLAG @V2D3931 00282000
- TM IOERDATA,TIMEOT IS THIS A TIMEOUT CONDITION @V2D3931 00283000
- BZ INTREQID NO, CHECK FOR INTERVENTION REQ. @V2D3931 00284000
- TM RDEVFTR,FTRDIAL SWITCHED 3275? @V346931 00284050
- BZ RETDIAL NO, GO CHECK FOR DISABLE @V346931 00284100
- CLI 5(R4),X'0D' WRITE RESET CCW? @V346931 00284150
- BE INITREAD YES, GO RETRY OPERATION @V346931 00284200
- CLI 5(R4),X'0B' WRITE CONTINUE CCW? @V346931 00284250
- BE CALLWTR1 YES, BYPASS RETRY @V346931 00284300
- CLI 5(R4),X'0C' READ REMAINING DATA CCW? @V346931 00284350
- BE CALLWTR1 YES, BYPASS RETRY @V346931 00284400
- CLI 5(R4),X'0A' READ DATA CCW? @V346931 00284450
- BE RESTLINE YES, RESTORE LINE TO CONTROL MODE@V346931 00284500
- RETDIAL EQU * HANDLE NON-SWITCHED RECOVERY @V346931 00284550
- TM BSCFLAG,BSCRVI EXPECT EOT FROM RVI? @VA13084 00284650
- BO NOREST @VA13970 00284850
- BAL R5,READSUB HANDLE READ CCW @V2D3931 00285000
- B WRITE1 GO TO WRITE SECTION @V2D3931 00286000
- B CALLWTR1 GO WRITE ERROR MESSAGE @V2D3931 00287000
- WRITE1 EQU * HANDLE WRITE CCW @V2D3931 00288000
- CLI 0(R4),X'2F' IS THIS A DISABLE CCW @V2D3931 00289000
- BNE CALLWTR1 NO, GO WRITE ERROR MESSAGE @V2D3931 00290000
- FAILCCW EQU * SET UP RETRY FROM THE BEGINNING @V2D3931 00291000
- ST R4,IOBRCAW SAVE FAILING CCW ADDRESS @V2D3931 00292000
- B SETFLAG SET RESTART FLAG @V2D3931 00293000
- INTREQID EQU * @V2D3931 00294000
- MVI IOERNUM,INTREQU SET INTERVENTION REQ MESSAGE @V2D3931 00295000
- TM IOERDATA,INTRV IS THIS AN INTERVENTION CONDITION@V2D3931 00296000
- BZ BUSOCK NO, CHECK FOR BUS OUT CHECK @V2D3931 00297000
- BAL R5,READSUB GO HANDLE FAILING READ CCW @V2D3931 00298000
- B WRITE2 GO TO WRITE SECTION @V2D3931 00299000
- * B *+4 00300000
- POLCMD EQU * @V2D3931 00301000
- CLI 0(R4),X'09' IS THIS A POLL CCW @V2D3931 00302000
- BE SETRET YES, RETRY FROM BEGINNING OF CCWS@V2D3931 00303000
- CLI 5(R4),X'00' IS THIS AN ERP CCW @V2D3931 00304000
- BE FAILCCW YES, GO RETRY FAILING CCW @V2D3931 00305000
- SETRET EQU * SET UP RESTART FIELD @V2D3931 00306000
- CLC RDEVTYPC(2),=AL1(CLASTERM,TYPBSC) 3270 REMOTE? @VA11394 00306100
- BNE SETRETA NO, CONTINUE NORMALLY @VA11394 00306200
- CLI 5(R4),X'0B' READ RESPONSE TO TEXT @VA11394 00306300
- BNE SETRETA NO, CONTINUE NORMALLY @VA11394 00306400
- TM BSCFLAG,BSCRVI IS THIS A RVI CHANNEL PGM? @VA12565 00306410
- BO SETRETA YES, NO NEED TO RESELECT @VA12565 00306420
- TM IOBMISC2,IBBREAD ARE WE DOING A DATA WRITE? @VA13797 00306424
- BO SETRETB YES, SEE IF WE CAN RECOVER @VA13797 00306428
- SETRETC DS 0H @VA13797 00306432
- * THE RESELECT CODE RELIES ON THE FACT THAT THE SETCAW 00306436
- * SUBROUTINE IN DMKRGA HAS SAVED THE ADDRESS OF THE 00306440
- * CHANNEL PROGRAM CONTAINING THE WRITE DATA IN BSCSPTR. 00306444
- * THIS CHANNEL PROGRAM WILL BE USED WHEN THE POLL 00306448
- * SUCCEEDS. 00306452
- LA R5,BSCSCCW1 GET ADDRESSING CCW'S @VA11394 00306500
- ST R5,IOBRCAW RESTART CCW STRING @VA11394 00306600
- B SETFLAG GO SET RESTART FLAG @VA11394 00306700
- SETRETA DS 0H @VA11394 00306800
- MVC IOBRCAW(4),IOBCAW RESTART CCW STRING @V2D3931 00307000
- B SETFLAG GO SET RESTART FLAG @V2D3931 00308000
- SETRETB CLC IOBRCNT,F7+2 RESELECT AFTER SEVEN RETRIES @VA13797 00308070
- BE SETRETA NO, TRY I/O AGAIN @VA13797 00308140
- * CHECK FOR EQUAL IS USED SO THAT ONLY ONE RESELECT 00308210
- * IS ATTEMPTED. 00308280
- TM RDEVFTR,FTRDIAL IS DIAL FEATURE INDICATED? @VA13797 00308350
- BO SETRETC YES, THEN SELECTION DATA VALID. @VA13797 00308420
- L R5,BSCAUSER GET ADDRESS OF CURRENT NICK BLOCK@VA13797 00308490
- ICM R0,10,NICSELT-NICBLOK(R5) GET DOUBLE ADDRESSING @VA13797 00308560
- ICM R0,5,NICSELT-NICBLOK(R5) CHARACTERS @VA13797 00308630
- STCM R0,15,BSCSEL SAVE ADDRESS OF REMOTE STATION @VA13797 00308700
- MVI BSCSEL+4,ENQ SET UP ADDRESSING ENTRY @VA13797 00308770
- B SETRETC TRY TO SELECT TERMINAL @VA13797 00308840
- SPACE 1 00309000
- WRITE2 EQU * HANDLE WRITE CCW @V2D3931 00310000
- CLI 5(R4),X'0A' IS TEXT BEING TRANSFER @V2D3931 00311000
- BE CHKRES YES, CHECK RESIDUAL COUNT @V2D3931 00312000
- B POLCMD GO CHECK FOR POLL COMMAND @V2D3931 00313000
- BUSOCK EQU * HANDLE BUS OUT CHECK @V2D3931 00314000
- MVI IOERNUM,BUSOUTCK SET BUSOUT ERROR MESSAGE FLAG @V2D3931 00315000
- TM IOERDATA,BUSCE IS THIS A BUS OUT CHECK @V2D3931 00316000
- BZ DATCHECK NO, CHECK FOR DATA CHECK @V2D3931 00317000
- CLC IOBRCNT,F15+2 HIT THE LIMIT ? @VA08380 00318100
- BH CALLWTR1 YES, GO WRITE ERROR MESSAGE @V2D3931 00319000
- CLI 0(R4),X'02' IS THIS A READ CCW @V2D3931 00320000
- BE CALLWTR1 YES, GO WRITE ERROR MESSAGE @V2D3931 00321000
- CLI 0(R4),X'09' IS THIS A POLL CCW @V2D3931 00322000
- BE SETRET YES, RETRY FROM THE BEGINNING @V2D3931 00323000
- CLI 0(R4),X'01' IS THIS A WRITE CCW @V2D3931 00324000
- BNE FAILCCW GO RETRY FROM FAILING CCW @V2D3931 00325000
- CLI 5(R4),X'0A' IS ERROR PRIOR TO TEXT @V2D3931 00326000
- BNE FAILCCW YES, GO RETRY FAILING CCW @V2D3931 00327000
- CHKRES EQU * CHECK RESIDUAL COUNT AGAIN CCW @V2D3931 00328000
- BAL R5,RESCOUN GO CHECK RESIDUAL COUNT @V2D3931 00329000
- B CALLWTR1 GO WRITE ERROR MESSAGE @V2D3931 00330000
- DATCHECK EQU * HANDLE DATA CHECK @V2D3931 00331000
- MVI IOERNUM,DATAER INDICATE DATA CHECK MESSAGE @V2D3931 00332000
- TM IOERDATA,DATACK IS THIS A DATA CHECK ERROR @V2D3931 00333000
- BO READHAN YES, GO CHECK FOR READ CCW @V2D3931 00334000
- OVERRUN EQU * HANDLE OVERRUN CONDITION @V2D3931 00335000
- MVI IOERNUM,OVERERR INDICATE OVERRUN MESSAGE @V2D3931 00336000
- TM IOERDATA,OVERN IS THIS A OVERRUN CONDITION @V2D3931 00337000
- BO READHAN YES, GO CHECK FOR READ CCW @V2D3931 00338000
- COMDREJ EQU * HANDLE COMMAND REJECT @V2D3931 00339000
- MVI IOERNUM,BDSNS INDICATE BAD SENSE MESSAGE @V2D3931 00340000
- TM IOERDATA,COMRJ IS THIS A COMMAND REJECT @V2D3931 00341000
- BZ CALLWTR1 NO, GO WRITE ERROR MESSAGE @V2D3931 00342000
- MVI IOERNUM,REJ INDICATE COMMAND REJECT MESSAGE @V2D3931 00343000
- MVC IOBMISC2+3(1),IOERDATA MOVE IN SENSE DATA FOR @VA13518 00343300
- * COMMAND REJECT 00343600
- READHAN EQU * HANDLE READ CCW @V2D3931 00344000
- BAL R5,READSUB HANDLE READ CCW @V2D3931 00345000
- B CALLWTR1 IF NOT READ CCW, GO WRITE MSG. @V2D3931 00346000
- SPACE 1 00348000
- NOCCW EQU * @V2D3931 00349000
- MVI IOERNUM,FALSE INDICATE BAD SENSE MESSAGE @V2D3931 00350000
- CALLWTR1 EQU * @V2D3931 00351000
- OI IOERIND3,IOERCAN+IOERINFO SET ON CANCEL & INFORM@V2D3931 00352000
- BAL R5,FRETIOER RELEASE THE SECOND IOERBLOK @V2D3931 00354000
- L R0,=C'BSC ' IDENTIFICATION OF MODULE @V2D3931 00355000
- OI IOERFLG2,IOERMSW SET MESSAGE WRITER ACTIVE @V2D3931 00356000
- CLI IOERNUM,INTREQU IS IT INTERVENTION REQ. @VA04766 00357100
- BNE CALLMSW NO - LEAVE ACTION CODE INTACT @VA04766 00357200
- MVI IOERIND3,IOERACT MESSAGE IND. TO 'A' @VA04766 00357300
- CALLMSW CALL DMKMSWR ISSUE ERROR MESSAGE @VA04766 00357400
- NI IOERFLG2,X'FF'-IOERMSW CLEAR MESSAGE WRITER FLAG@V2D3931 00358000
- BAL R5,FRETIOER RELEASE THE SECOND IOERBLOK @V2D3931 00359000
- OI IOBSTAT,IOBFATAL SET I/O FATAL FLAG @V2D3931 00360000
- CORRECT EQU * FINISH SUCCESSFULLY @V2D3931 00361000
- L R7,IOBRCAW POINT AT RESTART CCW @VA13970 00361100
- L R7,0(R7) GET RESTART CCW @VA13970 00361150
- CLI 0(R7),ENQ IS IT AN ENQ?? @VA13970 00361200
- BNE NOREST NO, CONTINUE @VA13970 00361250
- CLC BSCRESP(2),BSCRCVD RESPONSE AN ACK0/ACK1? @VA13970 00361300
- BE SETRETA YES, RESTART FAILING CCW'S @VA13970 00361350
- CLC BSCRESP(2),BSCSEND RESPONSE AN ACK1/ACK0? @VA13970 00361400
- BE SETRETA YES, RESTART FAILING CCW'S @VA13970 00361450
- NOREST DS 0H CONTINUE AS BEFORE @VA13970 00361500
- L R7,RDEVIOER GET IOERBLOK BACK IN REG7 @VA13970 00361550
- SLR R1,R1 ZERO PARAMETER REG @VA03757 00362100
- CALL DMKIOEST GO UPDATE STATISTICAL COUNTERS @VA03757 00362200
- INITREAD EQU * @V346931 00362300
- BAL R5,FRETPTR RELEASE THE WORK AREA @V346931 00362400
- EXIT1 EQU * NO IOERBLOK POINTER @V2D3931 00363000
- NI IOBFLAG,X'FF'-(IOBRSTRT+IOBERP) RESET ERP & @V2D3931 00364000
- * RSTRT 00365000
- EXIT RETURN TO IOS @V2D3931 00366000
- EJECT 00367000
- FRETIOER EQU * RELEASE THE SECOND IOERBLOK @V2D3931 00368000
- ICM R1,15,IOBIOER IS THERE A SECOND IOERBLOK @V2D3931 00369000
- BZ NOTUSED NO, RETURN TO IN LINE CODE @V2D3931 00370000
- TM IOERCSW+5-IOERBLOK(R1),IFCC+CCC+CDC IS CHANNEL @V2D3931 00371000
- BZ CKEND NO, GO FRET IOERBLOK @V2D3931 00372000
- LR R3,R1 SAVE SECOND IOERBLOK ADDRESS @V2D3931 00373000
- L R1,IOERCCRA-IOERBLOK(R3) CHANNEL REC ADDR @V508690 00374500
- L R0,IOERCCRL-IOERBLOK(R3) CHANNEL REC LENGTH @V508690 00375500
- CALL DMKFRET RELEASE STORAGE FOR RECORD @V2D3931 00376000
- LR R1,R3 RESTORE SECOND IOERBLOK ADDRESS @V2D3931 00377000
- CKEND EQU * @V2D3931 00378000
- LA R0,IOERSIZE GET SIZE IN DOUBLEWORDS @V2D3931 00379000
- AH R0,IOEREXT-IOERBLOK(,R1) ADD EXTRA LENGTH @V2D3931 00380000
- CALL DMKFRET RELEASE STORAGE FOR IOERBLOK @V2D3931 00381000
- NOTUSED EQU * @V2D3931 00382000
- MVC IOBIOER,ZEROES CLEAR POINTER TO IOERBLOK @V2D3931 00383000
- BR R5 RETURN TO IN LINE CODE @V2D3931 00384000
- SPACE 2 00385000
- FRETPTR EQU * @V2D3931 00386000
- SR R0,R0 CLEAR REGISTER ZERO @V2D3931 00387000
- ICM R0,3,IOERDW GET ALLOCATED SIZE IN DOUBLEWORDS@V2D3931 00388000
- BCR 8,R5 IF ZERO, DON'T FRET STORAGE @V2D3931 00389000
- L R1,IOERLOC GET ADDRESS OF ALLOCATED STORAGE @V2D3931 00390000
- CALL DMKFRET RELEASE STORAGE @V2D3931 00391000
- SR R0,R0 CLEAR REGISTER 0 @V2D3931 00392000
- ST R0,IOERLOC CLEAR ADDR OF ALLOCATED STORAGE @V2D3931 00393000
- STH R0,IOERDW CLEAR SIZE AREA @V2D3931 00394000
- XC IOBRCAW,IOBRCAW CLEAR ADDRESS OF RETRY CCW'S @VA08266 00394100
- LA R1,ERPCCW3-ERPBSC(,R1) 8 BYTES AFTER WRITE @VA08266 00394200
- CL R1,IOBCSW CSW POINT TO THE WRITE ? @VA08266 00394300
- BNER R5 NO,ALL OK - RETURN @VA08266 00394400
- XC IOBCSW,IOBCSW YES, CLEAR OUT THE CSW @VA08266 00394500
- BR R5 RETURN TO IN LINE CODE @V2D3931 00395000
- SPACE 2 00395050
- RESTLINE EQU * RESTORE LINE TO CONTROL MODE @V346931 00395100
- CLC IOBRCNT,F15+2 HIT THE LIMIT ? @VA08380 00395160
- BH CALLWTR1 YES, GO ISSUE ERROR MESSAGE @V346931 00395200
- MVC BSCPCCW1(TWOCCW),WRITEOT WRITE EOT, READ RESPONS@V346931 00395250
- XC BSCRESP(L'BSCRESP),BSCRESP CLEAR INPUT BUFFER @V346931 00395300
- LA R5,BSCRESP GET ADDRESS OF RESPONSE BUFFER @V346931 00395350
- STCM R5,B'0111',BSCPCCW2+1 RESPONSE BUF ADDR TO CCW @V346931 00395400
- LA R1,BSCPCCW1 POINT TO START OF CCW CHAIN @V346931 00395450
- ST R1,IOBRCAW SAVE CCW CHAIN START ADDRESS @V346931 00395500
- B SETFLAG GO SET UP FOR RESTART OPERATION @V346931 00395550
- SPACE 2 00396000
- GETCUCCW EQU * @V2D3931 00397000
- L R4,IOERCSW GET FAILING CCW ADDRESS PLUS 8 @V2D3931 00398000
- LA R4,0(R4) CLEAR HIGH ORDER BYTE @V2D3931 00399000
- S R4,F8 GET FAILING CCW ADDRESS @V2D3931 00400000
- BM NOCCW IF NEGATIVE, WRITE ERROR MESSAGE @V2D3931 00401000
- BR R5 RETURN TO IN LINE CODE @V2D3931 00402000
- SPACE 2 00403000
- NAKSUB EQU * SET UP CCWS FOR NAK RESPONSE @V2D3931 00404000
- MVC ERPCCW2(8),WRITNAK GET WRITE CCW FOR NAK REPLY @V2D3931 00405000
- MVC ERPCCW3(8),TICCCW SET UP TIC CCW @V2D3931 00406000
- STCM R4,7,ERPCCW3+1 SAVE ADDRESS OF FAILING CCW @V2D3931 00407000
- XC BSCREAD(256),BSCREAD CLEAR READ BUFFER @V305798 00408000
- XC BSCREAD+256(L'BSCREAD-256),BSCREAD+256 @V305798 00409000
- BR R5 RETURN TO IN LINE CODE @V2D3931 00410000
- SPACE 2 00411000
- ENQSUB EQU * SET UP TO SEND ENQ RESPONSE @V2D3931 00412000
- MVC ERPCCW2(8),WRITENQ GET WRITE CCW FOR ENQ RESP. @V2D3931 00413000
- MVC ERPCCW3(8),TICCCW SET UP TIC CCW @V2D3931 00414000
- STCM R4,7,ERPCCW3+1 SAVE ADDRESS OF FAILING CCW @V2D3931 00415000
- XC BSCRESP(L'BSCRESP),BSCRESP CLEAR RESPONSE BUFFER@V2D3931 00416000
- BR R5 RETURN TO IN LINE CODE @V2D3931 00417000
- SPACE 2 00418000
- RESCOUN EQU * CHECK THE RESIDUAL COUNT @V2D3931 00419000
- LH R9,IOERCSW+6 GET RESIDUAL COUNT @V2D3931 00420000
- LH R6,6(R4) GET CCW COUNT @V2D3931 00421000
- CR R9,R6 ARE COUNTS EQUAL @V2D3931 00422000
- BE FAILCCW YES, GO RETRY FAILING CCW @V2D3931 00423000
- BR R5 RETURN TO IN LINE CODE @V2D3931 00424000
- SPACE 2 00425000
- READSUB EQU * HANDLE A FAILING READ CCW @V2D3931 00426000
- CLC IOBRCNT,F15+2 HIT THE LIMIT ? @VA08380 00427100
- BH CALLWTR1 YES, GO WRITE ERROR MESSAGE @V2D3931 00428000
- CLI 0(R4),X'02' IS THIS A READ CCW @V2D3931 00429000
- BNER R5 NO, RETURN TO IN LINE CODE @V2D3931 00430000
- CLI 5(R4),X'08' ARE WE CLEARING UNIT EXCEPTION @VA13944 00430100
- BNE READSUB1 NO, USE STANDARD RECOVERY @VA13944 00430200
- MVC IOBCAW+1(3),IOBMISC2+1 ELSE, SETUP TO RETRY @VA13944 00430300
- B SETRETA ORIGINAL FAILING CCWS @VA13944 00430400
- READSUB1 DS 0H RETRY FAILING READ CCW STRINGS @VA13944 00430500
- TM IOERDATA-IOERBLOK(R3),TIMEOT IS THIS A TIMEOUT @VM01049 00431000
- BNO NOTIMOUT NO, GO CHECK FOR FIRST ERROR @VA13970 00432010
- CLI 5(R4),X'0B' READ RESP TO TEXT CCW? @VA13970 00432020
- BE SENDENQ YES, THEN GO SEND AN ENQ @VA13970 00432030
- CLI 5(R4),X'0C' IS IT A BLOCK READ CCW? @VA13970 00432040
- BE SENDENQ YES, THEN GO SEND AN ENQ @VA13970 00432050
- B SETRETA NO, GO RETRY FAILING CCW @VA13970 00432060
- NOTIMOUT DS 0H @VA13970 00432070
- CLC IOBRCNT,F1+2 IS THIS THE FIRST ERROR ?? @VA03757 00432100
- BNE FORGETFG NO, FORGET THE READ FLAG @VA03757 00432200
- OI IOERFLG3,IOERREAD TURN ON READ FLAG FOR SDR @VA03757 00432300
- FORGETFG EQU * @VA03757 00432400
- CLI 5(R4),X'0A' IS TEXT BEING TRANSFER @VM01094 00433000
- BE RETRAN YES, SEND NAK RESPONSE TO DEVICE @VM01094 00434000
- CLI 5(R4),X'0C' IS THIS A BLOCK READ CCW @VM03043 00435000
- BE RETRAN YES, SEND NAK RESPONSE TO DEVICE @VM03043 00436000
- CLI 5(R4),X'04' TEXT BEING TRANSFER (STATION ERR)@VM01094 00437000
- BNE CHKRESP NO, EXPECTED REPLY FROM STATION @VM01094 00438000
- RETRAN EQU * ASK STATION TO RETRANSMIT TEXT @V2D3931 00439000
- BAL R5,NAKSUB SET UP CCWS TO SEND NAK RESPONSE @V2D3931 00440000
- LA R1,ERPCCW2 GET ADDRESS OF CCW STRING @V2D3931 00441000
- ST R1,IOBRCAW SET UP RESTART CAW FIELD @V2D3931 00442000
- B SETFLAG GO SET RESTART FLAG @V2D3931 00443000
- CHKRESP EQU * @V2D3931 00444000
- CLI 5(R4),X'0D' WRITE RESET CCW? @V346931 00444200
- BE SETRET YES, GO RESTART CCW STRING @V346931 00444400
- CLI 5(R4),X'05' IS THIS A READ RESPONSE TO ADDR. @V2D3931 00445000
- BE SETRET YES, GO RESTART CCW STRING @VA13944 00446100
- CLI 5(R4),X'0B' IS THIS A RESPONSE FROM TEXT @V2D3931 00447000
- BNE 4(R5) NO, RETURN TO IN LINE CODE PLUS 4@V2D3931 00448000
- SENDENQ EQU * SET UP CCWS FOR ENQ RESPONSE @V2D3931 00449000
- BAL R5,ENQSUB SET UP CCWS FOR ENQ RESPONSE @V2D3931 00450000
- LA R1,ERPCCW2 GET START OF CCW STRING @V2D3931 00451000
- ST R1,IOBRCAW SET UP RESTART CAW FIELD @V2D3931 00452000
- SETFLAG EQU * SET UP TO DO A RESTART OPERATION @V2D3931 00453000
- OI IOBFLAG,IOBRSTRT SET THE RESTART FLAG @V2D3931 00454000
- BAL R5,FRETIOER RELEASE THE SECOND IOERBLOK @V2D3931 00455000
- EXIT RETURN TO IOS FOR RESTART @V2D3931 00456000
- ************************************************************* 00457000
- EJECT 00458000
- * SENSE STATUS FOR THE TRANSMISSION CONTROL UNIT 00459000
- EQUI1 EQU X'10' EQUIPMENT CHECK @V2D3931 00460000
- BUSCE EQU X'20' BUS OUT CHECK @V2D3931 00461000
- INTRV EQU X'40' INTERVENTION CONDITION @V2D3931 00462000
- COMRJ EQU X'80' COMMAND REJECT @V2D3931 00463000
- OVERN EQU X'04' OVERRUN CONDITION @V2D3931 00464000
- DATACK EQU X'08' DATA CHECK ERROR @V2D3931 00465000
- TIMEOT EQU X'01' TIMEOUT CONDITION @V2D3931 00466000
- LDATA EQU X'02' LOST DATA CHECK @V2D3931 00467000
- SPACE 2 @VA13797 00467100
- * READ/WRITE OPERATION TYPES 00467200
- IBBSELA EQU X'80' ADDRESSING/SELECTING A STATION @VA13797 00467300
- IBBWRITE EQU X'40' WRITE DATA TO A REMOTE STATION @VA13797 00467400
- IBBREAD EQU X'20' GENERAL POLLING OF STATIONS @VA13797 00467500
- IBBSPOLL EQU X'10' SPECIFIC POLLING TO A STATION @VA13797 00467600
- SPACE 2 00468000
- * CODES USED FOR ERROR MESSAGE 00469000
- REJ EQU 0 COMMAND REJECT @V2D3931 00470000
- INTREQU EQU 1 INTERVENTION REQUEST @V2D3931 00471000
- BUSOUTCK EQU 2 BUSOUT CHECK @V2D3931 00472000
- EQUIP EQU 3 EQUIPMENT CHECK @V2D3931 00473000
- DATAER EQU 4 DATA CHECK @V2D3931 00474000
- OVERERR EQU 5 OVERRUN CHECK @V2D3931 00475000
- BDSNS EQU 16 BAD SENSE INFORMATION @V2D3931 00476000
- FALSE EQU 17 NOT/KNOWN @V2D3931 00477000
- TIMOUT EQU 28 TIMEOUT CONDITION @V2D3931 00478000
- LOST EQU 27 LOST DATA CHECK @V2D3931 00479000
- CHANERR EQU 20 CHANNEL ERROR @V2D3931 00480000
- ******* THE ABOVE CODES MUST BE IDENTICAL TO THE **************** 00481000
- ******* CODES IN THE MESSAGE WRITER (DMKMSW) **************** 00482000
- SPACE 2 00483000
- * DATA-LINK CONTROL CHARACTERS FOR 3270 REMOTE SYSTEM 00484000
- NAK EQU X'3D' NEGATIVE ACKNOWLEDGMENT @V2D3931 00485000
- ENQ EQU X'2D' ENQUIRY @V2D3931 00486000
- EOT EQU X'37' END OF TRANSMISSION @V346931 00486100
- SPACE 2 00487000
- * CCWS FOR BISYNC ERROR PROCEDURES 00488000
- DS 0D @V2D3931 00489000
- TICCCW DC X'08',AL3(0),AL1(SILI,X'00'),AL2(1) @V2D3931 00490000
- WRITNAK DC X'01',AL3(RGANAK),AL1(SILI+CC,X'06'),AL2(1) @VA13944 00491100
- WRITENQ DC X'01',AL3(RGAENQ),AL1(SILI+CC,X'00'),AL2(1) @V2D3931 00492000
- SPACE 2 00492100
- * 3275 DIAL SELECTION CCWS (PSUEDO POLLING OPERATION) @V346931 00492200
- WRITEOT DC X'01',AL3(RGAEOT),AL1(SILI+CC,X'02'),AL2(1) @V346931 00492300
- DC X'02',AL3(0),AL1(SILI,X'0D'),AL2(2) @V346931 00492400
- TWOCCW EQU (8*2) LENGTH OF TWO CCWS @V346931 00492500
- SPACE 2 00493000
- * STORAGE FOR DATA LINK CONTROL CHARACTERS 00494000
- RGANAK DC AL1(NAK) NEGATIVE RESPONSE CHARACTER @V2D3931 00495000
- RGAENQ DC AL1(ENQ) INQUIRY CHARACTER @V2D3931 00496000
- RGAEOT DC AL1(EOT) END OF TRANSMISSION @V346931 00496100
- ******************************************************************** 00497000
- EJECT 00498000
- LTORG @V2D3931 00499000
- EJECT 00500000
- ERPBSC DSECT @V2D3931 00501000
- ERPCCW1 DS D CCW FOR READ SLIP @V2D3931 00502000
- ERPCCW2 DS D CCW FOR WRITE RESPONSE TO STATION@V2D3931 00503000
- ERPCCW3 DS D CCW TRANSFER CONTROL TO FAIL. CCW@V2D3931 00504000
- ERPSIZE EQU (*-ERPBSC)/8 ERPBSC SIZE IN DOUBLE WORDS @V2D3931 00505000
- EJECT 00506000
- COPY BSCBLOKS @V2D3931 00507000
- COPY NETWORK 00507500
- EJECT 00508000
- COPY IOER @V2D3931 00509000
- EJECT 00510000
- COPY RBLOKS @V2D3931 00511000
- EJECT 00512000
- COPY IOBLOKS @V2D3931 00513000
- EJECT 00514000
- COPY CONBUF @V2D3931 00515000
- EJECT 00516000
- COPY DEVTYPES @V2D3931 00517000
- EJECT 00518000
- COPY EQU @V2D3931 00519000
- EJECT 00520000
- COPY SAVE @V2D3931 00521000
- EJECT 00522000
- PSA @V2D3931 00523000
- END 00524000
ibm/vm370-lib/cp/dmkbsc.assemble_src.txt ยท Last modified: 2023/08/06 13:36 by Site Administrator