- [00006] CLD–PLATO IV COMMUNICATION LINK DRIVER
- [00033] DIRECT CELL ASSIGNMENTS
- [00149] MAIN PROCESSING LOOP
- [00191] PROCESS REQUEST
- [00241] RESERVE LINK
- [00283] RESERVE LOCAL EQUIPMENT AND CHANNEL
- [00335] RELEASE LOCAL EQUIPMENT AND CHANNEL
- [00374] REMOTE STARTUP
- [00426] SEND AND RECEIVE A MESSAGE
- [00452] DE-ESTABLISH LINK
- [00542] SPECIAL ROUTINES
- [00554] LOOPBACK TEST
- [00619] LOCAL TERMINAL MODE DRIVER
- [00662] TERMINAL MODE IO
- [00720] GET KEY FROM ECS KEY BUFFER
- [00793] SEND FRAME TO PLATO
- [00869] MOVE FRAME
- [00913] REMOTE TERMINAL MODE DRIVER
- [00972] TERMINAL MODE IO
- [01013] SEND KEY TO PLATO
- [01153] GET FRAMES FROM ECS
- [01239] MOVE KEY
- [01360] TERMINAL MODE INPUT-OUTPUT
- [01478] READ ECS
- [01568] WRITE ECS
- [01664] CLOCK
- [01715] READ AND CLEAR PPU COMMUNICATIONS SWITCH
- [01757] WRITE TO CM BUFFER.
- [01798] CHARACTER I/O
- [01930] WAIT CHARACTER READY OR REQUEST
- [01986] ODD CHANNEL STATUS/PUT CHARACTER
- [02039] GETCHR
- [02100] PACK DATA
- [02155] UNPACK
- [02207] DATAIN
- [02311] DATAOUT
- [02366] SEND MESSAGE
- [02419] RECEIVE A MESSAGE
- [02475] SELECT 6681 DATA CONVERTER
- [02566] SYNCHRONIZATION ESTABLISH
- [02621] DIVIDE BY 5
- [02648] INCREMENT 5 BYTE COUNTER
- [02684] PARITY GENERATION
- [02738] PAUSE–CHECK FOR STORAGE MOVE OR ERROR CONDITIONS
- [02829] SOFTWARE AND HARDWARE ERROR ROUTINES
- [02876] EXIT ROUTINES
- [02899] SEND END LINK
- [02946] TERMINAL MODE TERMINATION
- [02991] SEND PLATO REQUEST
- [03035] PROCESS 3266 INPUT
- [03064] WAIT ON LINKCTL
- [03088] EQUATES
- [03131] STORAGE DEFINITIONS
- [03208] COMMUNICATION BUFFERS
- [03306] COMMUNICATION BUFFERS
- [03343] ERROR CODES
- [03372] COMMAND CODES AND CONTROL CHARACTERS
- [03419] 6681 AND 311-B CODES
- [03459] INITIALIZATIONS
Source Code
- CLD.txt
- CLD
- * /--- FILE TYPE = E
- * /--- BLOCK CLD 00 000 78/02/06 11.43
- IDENT CLD,CLD
- * CZZ
- TITLE CLD--PLATO IV COMMUNICATION LINK DRIVER
- PERIPH
- SST FNTL
- COMMENT LINK DRIVER
- *
- *CALL COMPMAC
- *CALL PTEXT
- *CALL PLAP501
- *
- *CALL AIDTEXT
- QUAL CPS
- *CALL COMSCPS
- QUAL *
- PORT MACRO P1
- LOCAL N,N1
- N VFD 12/7700B+C=CH
- IFEO IFC EQ,*P1*EVEN*
- N1 VFD 12/5100B+E=CH
- CHAN E=CH,N1
- IFEO ELSE
- N1 VFD 12/5101B+O=CH
- CHAN O=CH,N1
- IFEO ENDIF
- CHAN C=CH,N
- ENDM
- * /--- BLOCK DIRECT 00 000 76/05/13 14.53
- TITLE DIRECT CELL ASSIGNMENTS
- ************************************************************************
- T0 EQU 0 *
- *
- T1 EQU 1 *
- *
- T2 EQU 2 *
- *
- T3 EQU 3 * TEMPORARY STORAGE
- *
- T4 EQU 4 *
- *
- T5 EQU 5 *
- *
- T6 EQU 6 *
- *
- T7 EQU 7 *
- *
- CM EQU 10B CM WORD BUFFER(5 WORDS)
- *
- LA EQU 15B PP PACKAGE LOAD ADDRESS
- *
- T8 EQU 16B TEMPORARY STORAGE
- *
- T9 EQU 17B TEMPORARY STORAGE
- *
- FUNC EQU 20B CURRENT REQUEST FUNCTION.
- *
- CHAR EQU 21B LAST CHARACTER INPUT
- *
- NC EQU 22B NUMBER OF TIMES TO CHECK FOR
- * CHARACTER READY.
- TI EQU 23B COUNTER SET IN PAUSE SO THAT
- * WE DO NOT LOOP TO LONG IN
- * CHARARCTER STATUS ROUTINES
- * WITHOUT CHECKING FOR STORAGE
- * RELOCATION.
- NAKFLAG EQU 24B 0=LAST BLOCK RECEIVED OKAY
- * 1=ERROR IN LAST BLOCK
- LT EQU 25B NUMBER CM WORDS IN LAST
- * LINKCTL COMMAND.
- DL EQU 26B NUMBER OF CM DATA WORDS IN
- * COMMUNICATION BUFFER.
- D0 EQU 27B TEMPORARY STORAGE
- *
- KEY EQU 30B POINTER TO NEXT KEY TO SEND
- * WHEN IN TERMINAL MODE.
- FRAME EQU 31B POINTER TO NEXT FRAME TO SEND
- * WHEN IN TERMINAL MODE
- MODE EQU 32B =0 FOR FILE TRANSFER MODE
- * =1 FOR TERMINAL MODE
- RESEND EQU 33B NUMBER OF TIMES A MESSAGE HAS
- * BEEN RESENT.
- TT EQU 34B TEMPORARY STORAGE
- *
- SC EQU 35B SYNC CODE COUNTER
- *
- OC EQU 36B OUTPUT CHARACTER
- *
- * /--- BLOCK DIRECT 00 000 78/01/05 09.02
- ULP EQU 37B UPPER-LOWER POINTER FOR PACKING
- *
- ULU EQU 40B UPPER-LOWER POINTER FOR
- * UNPACKING.
- WP EQU 41B PPU WORD CURRENTLY BEING PACKED
- *
- WU EQU 42B PPU WORD CURRENTLY BEING
- * UNPACKED.
- NW EQU 43B NUMBER OF PPU WORDS IN THIS
- * MESSAGE.
- CKO EQU 44B LONGITUDINAL PARITY WORD FOR
- * OUTPUT DATA.
- CKI EQU 45B LONGITUDINAL PARITY WORD FOR
- * INPUT DATA.
- FRCHK EQU 46B TIME OUT COUNTER FOR READING
- * FRAMAT STATUS WORD
- SENDI EQU 47B SEND KEY INDEX
- * EOD,EOB, OR EOF.
- IR EQU 50B INPUT REGISTER(5 WORDS)
- *
- RA EQU 55B REFERENCE ADDRESS/100
- *
- FL EQU 56B FIELD LENGTH/100
- *
- ECS EQU 60B POINTER TO ECS ADDRESS FOR
- * READ AND WRITE ECS ROUTINES
- STATION EQU 61B STATION NUMBER OF LINKCTL
- *
- BADC EQU 62B CONSECUTIVE BAD CHAR. COUNT.
- *
- ECSOFF EQU 63B OFFSET TO BE ADDED TO BASE
- * ECS ADDRESS
- TIME EQU 64B TIME-OUT COUNTER FOR TERMINAL
- * MODE, NO CHAR. READY STATUS.
- PS EQU 65B HARDWARE STATUS
- *
- TMSTAT EQU 66B TERMINAL MODE STATION
- *
- CLK EQU 67B LAST CLOCK TIME
- *
- ON EQU 70B CONSTANT 1
- *
- HN EQU 71B CONSTANT 100
- *
- TH EQU 72B CONSTANT 1000
- *
- TR EQU 73B CONSTANT 3
- *
- CP EQU 74B CONTROL POINT ADDRESS
- *
- IA EQU 75B INPUT REGISTER ADDRESS
- *
- OA EQU 76B OUTPUT REGISTER ADDRESS
- *
- MA EQU 77B MESSAGE BUFFER ADDRESS
- * /--- BLOCK MAIN LOOP 00 000 78/05/11 21.44
- TITLE MAIN PROCESSING LOOP
- ORG PPFW
- *
- CLD BSS 0 CZZ
- *
- * * * PERFORM INITIALIZATIONS
- *
- RJM INITIAL
- CALL PARGEN GENERATE PARITY TABLE
- *
- * * * CHECK TO SEE IF IT IS NECESSARY TO PAUSE
- * FOR STORAGE RELOCATION.
- *
- MAIN BSS 0
- RJM PAUSE CHECK FOR PAUSE CONDITIONS
- *
- * * * PROCESS ANY 3266 INPUT
- CALL LOOPCHK
- *
- * * * CHECK FOR DROP SIGNAL FROM PLATO LESSON
- *
- CALL DROPCHK
- *
- * * * CHECK FOR REQUEST PENDING
- * ON RETURN IF -A- IS ZERO NO NEW REQUEST
- *
- RJM READSW
- ZJN MAIN NO NEW REQUEST
- STD LT SAVE LENGTH OF NEW REQUEST
- *
- * * * READ REQUEST FROM CM TO -IBF-
- *
- RJM READ
- *
- * * * PROCESS NEW REQUEST
- *
- RJM PROC
- *
- * * * WAIT FOR NEW REQUEST
- *
- UJN MAIN
- *
- TITLE PROCESS REQUEST
- *
- * * PROC
- *
- * THIS ROUTINE DETERMINES WHAT FUNCTION IS BEING
- * REQUESTED AND JUMPS TO THE CORRECT ROUTINE TO
- * PROCESS IT. IF AN ILLEGAL FUNCTION CODE IS
- * RECEIVED AN ERROR CODE IS PLACED INTO THE
- * RESPONSE AND THE REQUEST IS MARKED DONE.
- *
- PROC SUBR
- *
- * * * ISOLATE FUNCTION CODE
- *
- LDM IBF+RFUNC
- STD FUNC
- *
- * * * CHECK FOR LEGAL FUNCTION
- *
- SBN FLST SUBTRACT HIGHEST LEGAL CODE+1
- PJN PRERR JUMP IF OUT OF RANGE
- *
- * * * JUMP TO PROCESS
- *
- PROCE BSS 0
- LDM PTABLE,FUNC
- STD D0
- LJM 0,D0
- *
- * * * JUMP TABLE FOR FUNCTION CODE PROCESSING
- *
- PTABLE BSS 0
- VFD 12/STUP 00 CHECK FOR STARTUP
- VFD 12/PRES 01 RESERVE LINK
- VFD 12/MESSIO 02 SEND AND RECEIVE MESSAGE
- VFD 12/PREL 03 RELEASE LINK
- VFD 12/STCOMD 04 RETURN 311 STATUS
- VFD 12/STATS 05 RETURN DRIVER STATISTICS
- VFD 12/TEST 06 RUN SPECIAL ROUTINE
- VFD 12/LTLINK 07 LOCAL TERMINAL MODE DRIVER
- VFD 12/RTLINK 10 REMOTE TERMINAL MODE DRIVER
- VFD 12/PRERR
- VFD 12/TLOP 12 LOOP BACK TEST
- FLST EQU *-PTABLE
- *
- * * * ERROR--ILLEGAL FUNCTION CODE
- *
- PRERR BSS 0
- CALL SERROR,SIFC
- * /--- BLOCK PRES 00 000 77/10/01 00.02
- TITLE RESERVE LINK
- *
- * *PRES
- *
- * THIS ROUTINE ATTEMPTS TO RESERVE THE LOCAL
- * AND REMOTE COMMUNICATION EQUIPMENT.
- *
- PRES BSS 0
- *
- * * * GET AND SAVE LINKCTL STATION NUMBER
- *
- LDM IHDR+STNO
- STD STATION
- *
- * * * SAVE PLATO*S ECS RA
- LDM XECU
- STM ECU
- LDM XECL
- STM ECL
- *
- * * * IS LINK ALREADY IN SYNC
- *
- LDM SFLAG
- NJP MESSIO JUMP IF YES
- *
- * * * RESERVE LOCAL EQUIPMENT FIRST.
- *
- RJM LRES
- *
- * * * SETUP 6681
- *
- PRES0 BSS 0
- RJM SELDC
- *
- * * * WAIT FOR SYNCHRONIZATION TO BE ESTABLISHED
- *
- CALL SEST,2400
- *
- * * * SEND START-UP MESSAGE
- *
- LJM MESSIO
- * /--- BLOCK LRES 00 000 77/08/29 15.39
- TITLE RESERVE LOCAL EQUIPMENT AND CHANNEL
- *
- * *LRES
- *
- * THIS ROUTINE ATTEMPTS TO RESERVE THE COMMUNICATION
- * LINK BY RESERVING EQUIPMENT -CL- AND CHANNEL
- * -CH-.
- *
- LRES SUBR
- *
- * * * DO NOT RESERVE EQUIPMENT IF ALREADY RESERVED
- LDC ALSEVEN
- SBM CLEQ
- NJN LRESX IF EQUIPMENT ALREADY RESERVED
- *
- * * * FIND EQUIPMENT ORDINAL AND CHANNEL NUMBER.
- LDC 2RCL
- CALL EQN
- MJP LRES1 JUMP IF EQUIP NOT AVAILABLE
- STD CM+1 SAVE EQUIPMENT ORDINAL
- LDD CM GET CHANNEL NUMBER
- STD TT SAVE IT.
- *
- * * * RESERVE CHANNEL AND EQUIPMENT
- MONITOR REQM RESERVE EQUIPMENT
- LDD CM+1 READ REPLY
- ZJP LRES1 JUMP IF EQUIP ALREADY RESERVED
- STM CLEQ SAVE ORDINAL
- *
- LDD TT GET CHANNEL NO.
- RCHAN
- LDD CM+1 CHECK MONITOR REPLY
- ZJP LRES2 JUMP CHANNEL NOT AVAILABLE
- STM CLCH SAVE CHANNEL NUMBER
- *
- * * * PLUG CHANNEL AND PORT NUMBERS
- PLANT CHANNEL,C=CH PLUG CHANNEL NUMBER.
- LDM XPORTCH GET 311 CHANNEL NUMBER
- PLANT CHANNEL,E=CH PLUG CHANNEL NUMBER.
- LDM XPORTCH
- ADN 1 MAKE ODD CHANNEL NUMBER
- PLANT CHANNEL,O=CH PLUG ODD CHANNEL.
- LJM LRESX
- *
- * * * ERROR--EQUIPMENT ALREADY RESERVED
- LRES1 BSS 0
- CALL SERROR,SENA
- *
- * * * ERROR--CHANNEL ALREADY RESERVED
- LRES2 BSS 0
- CALL SERROR,SCNA
- * /--- BLOCK LREL 00 000 77/08/29 15.40
- TITLE RELEASE LOCAL EQUIPMENT AND CHANNEL
- *
- * *LREL
- *
- * THIS ROUTINE RELEASES THE RESERVE ON THE LOCAL
- * COMMUNICATION LINK EQUIPMENT -CL- AND THE
- * ASSOCIATED CHANNEL(C=CH) IF IN FACT THEY HAVE
- * BEEN RESERVED.
- *
- LREL SUBR
- *
- * * * HAS -CL- BEEN RESERVED
- LDC ALSEVEN
- SBM CLEQ
- ZJN LREL1 JUMP IF NOT
- *
- * * * RELEASE EQUIPMENT
- LDM CLEQ GET EST ORDINAL OF -CL-
- STD CM+1
- MONITOR DEQM RELEASE THE EQUIPMENT
- *
- * * * CHECK IF CHANNEL HAS BEEN RESERVED
- LREL1 BSS 0
- LDC ALSEVEN
- SBM CLCH CHECK CHANNEL FLAG
- ZJN LREL2 IF ALL SEVENS CHANNEL HAS NOT
- * YET BEEN RESERVED
- *
- * * * RELEASE CHANNEL
- LDM CLCH
- DCHAN
- *
- * * * SET INDICATORS SHOW NO EQUIPMENT RESERVED
- LREL2 BSS 0
- LDC ALSEVEN
- STM CLEQ
- STM CLCH
- UJN LRELX
- * /--- BLOCK STARTUP 00 000 78/03/30 10.23
- TITLE REMOTE STARTUP
- *
- * * STUP
- *
- * CHECK TO SEE IF REMOTE SITE IS REQUESTING
- * USE OF LINK. IF SO SEND ACKNOWLEDGE AND
- * INFORM LINKCTL.
- *
- STUP BSS 0
- *
- * * * GET AND SAVE LINKCTL STATION NUMBER
- *
- LDM IHDR+STNO
- STD STATION
- *
- * * * SAVE PLATO*S ECS RA
- LDM XECU
- STM ECU
- LDM XECL
- STM ECL
- *
- * * * IS LINK ALREADY IN SYNC
- *
- LDM SFLAG
- NJP STUP1 JUMP IF YES
- *
- * * * RESERVE LOCAL EQUIPMENT
- *
- RJM LRES
- *
- * * * SET UP 6681
- *
- RJM SELDC
- *
- * * * ESTABLISH SYNCHRONIZATION
- *
- CALL SEST,750
- *
- * * * SET SYNC CODE COUNTER TO ZERO
- *
- STUP1 BSS 0
- LDN 0
- STD SC
- *
- * * * CHECK FOR MESSAGE.
- *
- CALL MESSIN
- *
- * * * RECEIVED STARTUP MESSAGE INFORM LINKCTL.
- *
- CALL WRITE
- LJM PROCX
- TITLE SEND AND RECEIVE A MESSAGE
- *
- * * MESSIO
- *
- * SEND MESSAGE TO REMOTE SITE AND WAIT FOR
- * A RETURNING MESSAGE.
- *
- MESSIO BSS 0
- *
- * * * MAKE SURE REMOTE STILL IN TOUCH
- *
- CALL SEST,2
- *
- * * * OUTPUT MESSAGE
- *
- CALL MESSOUT
- *
- * * * WAIT FOR RESPONSE
- *
- CALL MESSIN
- *
- * * * SEND MESSAGE TO LINKCTL
- *
- CALL WRITE
- LJM PROCX
- * /--- BLOCK REL/STATUS 00 000 77/10/02 22.39
- TITLE DE-ESTABLISH LINK
- *
- * *PREL
- *
- * RELEASE REMOTE AND LOCAL COMMUNICATION EQUIPMENT.
- *
- PREL BSS 0
- *
- * * * MAKE SURE REMOTE IS STILL IN TOUCH
- *
- CALL SEST,2
- *
- * * * SEND EOT MESSAGE TO REMOTE SITE
- *
- CALL MESSOUT
- *
- * * * INFORM -LINKCTL- THAT THE REQUEST IS COMPLETE
- *
- RJM WRITE
- LJM PROCX WAIT FOR NEXT COMMAND
- SPACE 2
- *
- * * STCOMD
- *
- * THIS ROUTINE INPUTS THE STATUS FROM BOTH THE ODD
- * AND EVEN CHANNELS AND RETURNS IT TO -LINKCTL-.
- *
- STCOMD BSS 0
- LDM IHDR+STNO
- STD STATION
- *
- * * * RESERVE EQUIPMENT AND CHANNEL
- *
- RJM LRES
- RJM SELDC
- *
- * * * GET ODD CHANNEL STATUS
- *
- CALL ICHR2
- STM OBF+RSTA SAVE FOR THE RESPNSE
- *
- * * * GET EVEN CHANNEL STATUS
- *
- RJM ICHR
- STM OBF+RSTA1 PUT INTO RESPONSE
- *
- * * * SEND RESPONSE TO LINKCTL
- *
- RJM WRITE
- LJM PROCX WAIT FOR NEXT COMMAND
- EJECT
- *
- *
- * * STATS
- *
- * THIS ROUTINE PASSES ALL STATISTICS CELLS
- * TO -LINKCTL-.
- *
- STATS SUBR
- *
- * * * MOVE STATISTICS CELLS TO COMMUNICATION BUFFER
- *
- LDM PECNT
- STM DSTATS
- LDM BDCNT
- STM DSTATS+4
- LDM LPCNT
- STM DSTATS+9
- LDM SCCNT
- STM DSTATS+14
- LDM BCCNT
- STM DSTATS+19
- LDN 0
- STM PECNT
- STM BDCNT
- STM LPCNT
- STM SCCNT
- STM BCCNT
- *
- * * * SET NUMBER OF WORDS USED IN DATA SECTION
- * OF COMMUNICATION BUFFER
- *
- LDN 6
- STD DL
- *
- * * * SEND RESPONSE
- *
- RJM WRITE
- LJM PROCX WAIT FOR NEXT COMMAND
- *
- TITLE SPECIAL ROUTINES
- *
- * * SPEC
- *
- * FUNCTION CODE RESERVED FOR SPECIAL FUNCTIONS
- *
- SPEC BSS 0
- *
- * * * SEND RESPONSE
- RJM WRITE
- LJM PROCX WAIT FOR NEXT COMMAND
- * /--- BLOCK TLOP 00 000 77/09/22 00.37
- TITLE LOOPBACK TEST
- *
- * * TLOP
- *
- * TEST LOOP BACK TO MAKE SURE DATA IS BEING SENT
- * AND RECEIVE AT THIS SITE PROPERLY, ALSO CHECKS
- * TELEPHONE EQUIPMENT.
- *
- TLOP BSS 0
- LDM IHDR+STNO
- STD STATION
- *
- * * * RESERVE LOCAL EQUIPMENT
- RJM LRES
- *
- * * * SETUP 6681
- RJM SELDC
- *
- * * * ESTABLISH SYNCHRONIZATION
- CALL SEST,100
- *
- * * * SET TO OUTPUT 100 CHARACTERS OF DATA
- LDC 99
- STD SC
- *
- * * * WAIT FOR CHARACTER READY OR CHARACTER REQUEST
- NTL1 BSS 0
- CALL WCR,MCRQ+MCRD
- SHN 6
- MJN NTL2 JUMP IF CHARACTER READY
- *
- * * * OUTPUT A CHARACTER
- LDM XPATTRN
- CALL PUTCHR
- UJN NTL1
- *
- * * * SAVE INPUT CHARACTER IN DATA BUFFER FOR LINKCTL
- NTL2 BSS 0
- LDD CHAR
- STM DBUFF,SC
- *
- * * * INFINITE LOOP OR ONLY A HUNDRED
- LDM XLOOPS
- NJP NTL1 JUMP IF INFINITE LOOP
- *
- * * * HAVE 100 CHARACTERS BEEN OUTPUT
- SOD SC
- PJN NTL1 JUMP IF NOT
- *
- * * * SET TO PASS ALL INPUT TO LINKCTL
- LDN 21
- STD DL
- *
- * * * SEND RESPONSE
- RJM WRITE
- LJM PROCX WAIT FOR NEXT COMMAND
- * /--- BLOCK TEST 00 000 78/01/04 10.52
- *
- * * SPECIAL TEST ROUTINES
- *
- EJECT
- TEST BSS 0
- LJM PROCX WAIT FOR NEXT COMMAND
- * /--- BLOCK LTLINK 00 000 78/01/05 09.03
- TITLE LOCAL TERMINAL MODE DRIVER
- *
- * * LTLINK
- *
- * THIS ROUTINE COMMUNICATES WITH PLATO AT THE SYSTEM
- * LOCAL TO THE TERMINAL. ITS JOB IS TO GET
- * KEYS FROM PLATO AND SEND THEM OVER THE LINK TO THE
- * REMOTE SYSTEM, WHILE AT THE SAME TIME ACCEPTING
- * FRAMES FROM THE LINK AND PUTTING THEM INTO
- * FRAMERS LINK BUFFER.
- *
- LTLINK BSS 0
- *
- * * * SET MASKS IN -TMIN- AND -TMOUT-
- LDN 1
- STM TOMK SET TO 1, FOR KEY OUTPUT
- LDN 3
- STM TIMK SET TO 3, FOR FRAME INPUT
- *
- * * * DO INITIALIZATIONS
- CALL TMSTART
- *
- * * * CHECK IF TIME TO SEND KEY OR GET FRAME
- LT0 BSS 0
- CALL CLOCK,7
- NJN LT1
- *
- * * * TALK TO PLATO THROUGH ECS
- CALL SENDFRM SEND FRAME TO PLATO
- CALL LCHK SERVICE COMMUNICATION EQUIP.
- CALL GETKEY CHECK FOR KEY INPUT
- CALL FRMOVE READY ANOTHER FRAME IF ONE.
- LT1 BSS 0
- CALL LCHK SERVICE COMMUNICATION EQUIP.
- *
- * * * IS IT TIME TO CHECK FRAMAT STATUS
- SOD FRCHK
- NJP LT0
- *
- * * * CHECK FOR FRAMAT RE-INITIALIZING
- CALL FRMCHK
- UJP LT0
- * /--- BLOCK LCHK 00 000 84/11/15 11.33
- TITLE TERMINAL MODE IO
- *
- * * LCHK
- *
- * 'CHECK COMMUNICATION EQUIPMENT TO SEE IF INPUT
- * WAITING OR READY TO SEND OUTPUT.
- *
- LCHK SUBR
- *
- * * * CHECK FOR CHARACTER READY OR CHARACTER REQUEST
- CALL WCR,MCRD+MCRQ
- ZJN LCHKX IF NEITHER STATUS APPEARED
- SHN 6
- PJN LCHK1 JUMP IF CHARACTER REQUEST
- *
- * * * CHECK FOR BUFFER OVERFLOW
- LDD ULP NEXT *IN* POINTER
- ADN CHPF CHARACTERS PER FRAME
- SBD FRAME NEXT *OUT* POINTER
- LPC TMASK KEEP IN RANGE
- ZJP OVERFLOW
- *
- * * * CHARACTER READY STATUS - PROCESS INPUT
- CALL TMIN
- MJN LCHKX IF ONLY SYNC CHARACTER
- *
- * * * MOVE FRAME TO -FRBUFF- IF NECESSARY OR POSSIBLE
- LDM FRBUFF
- NJN LCHKX IF ALREADY FILLED
- CALL FRMOVE READY NEXT FRAME
- LCHK2 UJN LCHKX
- *
- * * * CHECK CHARACTER IN TIME OUT
- LCHK1 BSS 0
- AOD TIME BUMP TIME OUT COUNTER
- ADC -ALSEVEN CHECK VALUE OF COUNTER
- ZJP LOSTC JUMP IF TIMED OUT
- *
- * * * DO WE HAVE OUTPUT TO SEND
- LDD KEY
- SBD ULU
- ZJN LCHK2 IF NO OUTPUT
- *
- * * * SEND KEY TO REMOTE SYSTEM
- CALL TMOUT
- UJN LCHK2
- *
- * * * INCREMENT OVERFLOW COUNTER
- OVERFLOW BSS 0
- AOM OVER
- LOADCM COMBF
- ADN 3
- CWM OVER,ON
- UJN LCHK2
- * *
- OVER BSSZ 1
- DIS ,*OVERFLOW*
- * /--- BLOCK GETKEY 00 000 77/10/02 23.04
- TITLE GET KEY FROM ECS KEY BUFFER
- *
- * * GETKEY
- *
- * THE KEY BUFFER CORRESPONDING TO THE TERMINAL
- * MODE STATION (TMSTAT) IS CHECK. 'IF A NEW
- * KEY IS PRESENT IT IS MOVED TO THE LINK OUTPUT
- * BUFFER AND THE CPU INDEX IS INCREMENTED BY
- * ONE. THE SECOND WORD OF THE KEY BUFFER IS THEN
- * WRITTEN BACK TO ECS TO UPDATE THE CPU INDEX.
- *
- * FORMAT OF KEY BUFFER';
- * / KEY / KEY / KEY / KEY / PPU INDEX /
- * / PRESS AND TIMING KEYS / CPU INDEX /
- *
- GETKEY SUBR
- *
- * * * CALCULATE OFFSET TO LINK STATIONS KEY BUFFER
- LDD TMSTAT
- SHN 1 TWO WORDS PER STATION
- STD ECSOFF
- *
- * * * READ THE KEY BUFFER FROM ECS
- LDN 2
- STD ECS NUMBER OF CM WORDS TO READ
- CALL READECS,PKEYECS
- *
- * * * ARE THERE ANY NEW KEYS
- LDM LKBUF+4 PPU INDEX (INPUT PTR)
- SBM LKBUF+9 CPU INDEX (OUTPUT PTR)
- ZJN GETKEYX IF NO NEW KEYS
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL LCHK
- *
- * * * INCREMENT CPU INDEX AND LOCATE NEXT KEY
- AOM LKBUF+9
- LPN 3 MASK INDEX FOR MOD 4
- STD D0
- LDM LKBUF,D0 GET KEY
- STM KYBUFF SAVE KEY
- *
- * * * MOVE SECOND WORD OF KEY BUFFER TO FIRST
- * WORD OF PPU BUFFER SO IT CAN BE WRITTEN BACK.
- *
- LDN 4
- STD D0
- GK1 BSS 0
- LDM LKBUF+5,D0
- STM LKBUF,D0
- SOD D0
- PJP GK1 JUMP IF NOT ALL MOVED
- *
- * * * WRITE BACK TO ECS
- AOD ECSOFF POINT TO CPU WORD
- LDN 1
- STD ECS WRITE ONE WORD
- CALL WRITECS,PKEYECS
- *
- * * * MOVE NEW KEY TO OUTPUT BUFFER
- LDD KEY LOAD CHARACTER POSITION
- SHN -1 DIVIDE BY TWO, WORD POSITION
- STD TT SAVE
- LDM KYBUFF GET NEW KEY
- STM ISTART,TT MOVE TO OUTPUT BUFFER.
- *
- * * * MOVE POINTER TO NEXT AVAILABLE SPOT.
- LDD KEY GET POINTER
- ADN CHPK TWO CHARACTERS/KEY
- LPC TMASK KEEP MOD 128
- STD KEY
- LJM GETKEYX
- * /--- BLOCK SENDFRM 00 000 77/10/03 14.24
- TITLE SEND FRAME TO PLATO
- *
- * * SENDFRM
- *
- * IF A FRAME HAS BEEN RECEIVED FROM THE REMOTE
- * SYSTEM THIS ROUTINE WILL APPEND THE TERMINAL
- * MODE STATION NUMBER (TMSTAT) AND GIVE IT
- * TO THE FRAMER FOR OUTPUT TO THE APPROPRIATE
- * STATION. THE BUFFER (LINKIO) IS A CIRCULAR
- * BUFFER INTO WHICH THE PPU WRITES THE FRAMES
- * AND FROM WHICH THE FRAMER REMOVES THEM. LKIN
- * CONTROLS INPUT TO THE BUFFER WHILE LKOUT
- * CONTROLS REMOVAL OF INFORMATION FROM THE BUFFER.
- *
- * INPUT PARAMETERS';
- * (FRBUFF) = FRAME OR 0 IF NONE READY
- *
- SENDFRM SUBR
- *
- * * * IS THERE A FRAME READY TO GIVE TO FRAMER
- LDM FRBUFF
- ZJN SENDFRMX
- *
- * * * READ IN/OUT POINTERS FROM ECS
- LDN 0
- STD ECSOFF
- LDN 2
- STD ECS
- CALL READECS,LKIN
- *
- * * * CHECK FOR BUFFER FULL
- LDM LKBUF+4 IN POINTER
- ADN 1 BUMP TO NEXT WORD
- SBM LKBUF+9 OUT POINTER
- LPC LKMASK BUFFER LENGTH MASK
- ZJN SENDFRMX IF BUFFER FULL
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL LCHK
- *
- * * * MOVE FRAME TO LKBUF FOR TRANSFER TO ECS
- LDM FRBUFF
- STM LKBUF
- LDM FRBUFF+1
- STM LKBUF+1
- *
- * * * ADD STATION NUMBER
- LDD TMSTAT
- STM LKBUF+2
- *
- * * * DETERMINE OFFSET IN LINKIO BUFFER
- LDM PFRAME+4
- LPC LKMASK BUFFER LENGTH MASK
- STD ECSOFF
- *
- * * * WRITE NEW FRAME TO ECS
- LDN 1
- STD ECS NUMBER OF WORDS TO WRITE
- CALL WRITECS,LINKIO
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL LCHK
- *
- * * * INCREMENT LINKIO PPU POINTER
- CALL AFIVE,PFRAME
- *
- * * * UPDATE ECS COPY OF POINTER
- LDN 0
- STD ECSOFF
- CALL WRITECS,LKIN
- *
- * * * SET NO FRAME INDICATOR IN FRBUFF
- LDN 0
- STM FRBUFF
- LJM SENDFRMX
- * /--- BLOCK FRMOVE 00 000 77/10/03 14.22
- TITLE MOVE FRAME
- *
- * * FRMOVE
- *
- * THIS ROUTINE IS CALLED IF -FRBUFF- IS EMPTY
- * (FRBUFF=0). ITS FUNCTION IS TO MOVE THE
- * NEXT FRAME FROM THE INPUT BUFFER TO -FRBUFF-.
- * THIS CAN ONLY BE DONE WHEN THERE IS IN FACT
- * A COMPLETE FRAME ASSEMBLED IN THE INPUT
- * BUFFER.
- *
- FRMOVE SUBR
- *
- * * * IS THERE A COMPLETE FRAME IN THE -DBUFF-.
- LDD FRAME OUTPUT POINTER
- SHN -2 DIVIDE BY FOUR CHARS/FRAME
- STD TT
- LDD ULP NUMBER OF CHARACTERS INPUT
- SHN -2 DIVIDE BY FOUR
- SBD TT SUBTRACT OUTPUT POINTER
- ZJN FRMOVEX IF NO FRAME
- *
- * * * MOVE NEXT FRAME TO -FRBUFF-
- LDD TT CALCULATE WORD POSITION
- SHN 1
- STD TT
- *
- * * * CHECK FIRST WORD FOR NEGATIVE VALUE(START BIT)
- LDM OSTART,TT 1ST WORD OF FRAME
- ADC 4000B ADD IN START BIT
- STM FRBUFF
- *
- * * * GET AND CHECK SECOND WORD OF FRAME, IS IT POSITIVE
- LDM OSTART+1,TT SECOND WORD OF FRAME
- STM FRBUFF+1
- *
- * * * ADJUST OUTPUT POINTER TO NEXT FRAME POSITION
- XFR1 BSS 0
- LDD FRAME GET CURRENT VALUE
- ADN CHPF FOUR CHARACTERS/FRAME
- LPC TMASK MODULO 512
- STD FRAME SAVE NEW VALUE
- UJN FRMOVEX
- * /--- BLOCK RTLINK 00 000 78/01/05 09.04
- TITLE REMOTE TERMINAL MODE DRIVER
- *
- * * RTLINK
- *
- * THIS ROUTINE COMMUNICATES WITH PLATO AT THE SYSTEM
- * REMOTE TO THE TERMINAL. ITS JOB IS TO GET
- * FRAMES FROM PLATO AND SEND THEM OVER THE LINK TO
- * THE SYSTEM LOCAL TO THE TERMINAL, WHILE AT THE
- * SAME TIME ACCEPTING KEYS FROM THE LINK AND
- * PUTTING THEM INTO PLATOS KEY BUFFER.
- *
- RTLINK BSS 0
- *
- * * * MAKE SURE REMOTE IS STILL IN TOUCH
- CALL SEST,2
- *
- * * * SEND REQUEST REPLY
- CALL MESSOUT
- *
- * * * SET MASK FOR IN -TMIN- AND -TMOUT-
- LDN 1
- STM TIMK SET TO 1, KEY INPUT
- LDN 3
- STM TOMK SET TO 3, FRAME OUTPUT
- *
- * * * DO INITIALIZATIONS
- CALL TMSTART
- *
- * * * WRITE NONZERO TO FRAMER STATUS WORD
- LDN 77B
- STM LKBUF+4
- LDN 1
- STD ECS NUMBER OF WORDS
- LDM FRAMID OFFSET TO CORRECT WORD
- STD ECSOFF
- CALL WRITECS,PIOSTS
- *
- * * * CHECK IF TIME TO SEND KEY OR GET FRAME
- * WILL BE DONE APPROXIMATELY EVERY 16 MS.
- RT0 BSS 0
- CALL CLOCK,15
- NJN RT1
- *
- * * * TALK TO PLATO THROUGH ECS
- CALL SENDKEY SEND KEY TO PLATO
- CALL RCHK SERVICE COMMUNICATION EQUIP
- CALL GETFRAM GET FRAME FROM PLATO
- CALL KYMOVE CHECK FOR ANOTHER KEY READY
- RT1 BSS 0
- CALL RCHK SERVICE COMMUNITION EQUIP
- *
- * * * IS IT TIME TO CHECK FRAMAT STATUS
- SOD FRCHK
- NJP RT0
- *
- * * * CHECK FOR FRAMAT RE-INITIALIZING.
- CALL FRMCHK
- UJP RT0
- * /--- BLOCK RCHK 00 000 84/11/15 11.33
- TITLE TERMINAL MODE IO
- *
- * * RCHK
- *
- * 'CHECK COMMUNICATION EQUIPMENT TO SEE IF INPUT
- * WAITING OR READY TO SEND OUTPUT.
- *
- RCHK SUBR
- *
- * * * CHECK FOR CHARACTER READY AND CHARACTER REQUEST
- CALL WCR,MCRD+MCRQ
- ZJN RCHKX IF NEITHER STATUS APPEARED
- SHN 6
- PJP RCHK1 JUMP IF CHARACTER NOT READY
- *
- * * * CHARACTER READY STATUS - PROCESS INPUT
- CALL TMIN
- MJN RCHKX IF ONLY SYNC CHARACTER
- *
- * * * MOVE KEY TO -KEYBUFF- IF NECESSARY OR POSSIBLE
- LDM KYBUFF
- SHN 6
- PJN RCHKX IF KEY ALREADY THERE
- CALL KYMOVE
- UJN RCHKX
- *
- * * * CHECK CHARACTER READY TIME OUT
- RCHK1 BSS 0
- AOD TIME BUMP TIME OUT COUNTER
- ADC -ALSEVEN CHECK VALUE OF COUNTER
- ZJP LOSTC JUMP IF TIMED OUT
- *
- * * * DO WE HAVE OUTPUT TO SEND
- LDD FRAME
- SBD ULU
- ZJN RCHKX IF NOTHING TO OUTPUT
- *
- * * * SEND FRAME TO REMOTE SYSTEM
- CALL TMOUT
- LJM RCHKX
- * /--- BLOCK SENDKEY 00 000 77/10/03 15.43
- TITLE SEND KEY TO PLATO
- *
- * * SENDKEY
- *
- * WHEN A KEY HAS BEEN RECEIVED FROM THE REMOTE
- * SYSTEM THIS ROUTINE READS THE KEY BUFFER
- * CORRESPONDING TO THE TERMINAL MODE STATION
- * (TMSTAT) AND MOVES THE KEY INTO THE CORRECT
- * BYTE. THE PPU INDEX IS THEN INCREMENTED AND
- * THE FIRST WORD OF THE KEY BUFFER IS WRITTEN
- * BACK TO ECS. THE KEYS-IN BIT CORRESPONDING
- * TO THIS STATION IS THEN SET IN THE ECS
- * KEYS-IN BUFFER (PECSIN).
- *
- * FORMAT OF KEY BUFFER';
- * / KEY / KEY / KEY / KEY / PPU INDEX /
- * / PRESS AND TIMING KEYS / CPU INDEX /
- *
- * INPUT PARAMETERS';
- * (KYBUFF) = KEY TO SEND OR 7777B IF NO KEY READY
- *
- SENDKEY SUBR
- *
- * * * CHECK FOR KEY TO SEND
- LDM KYBUFF
- SHN 6
- MJN SENDKEYX IF NO KEY READY TO SEND
- *
- * * * CALCULATE OFFSET TO KEY BUFFER
- LDD TMSTAT TERMINALS STATION NUMBER
- SHN 1 2 WORDS PER BUFFER
- STD ECSOFF OFFSET TO KEY BUFFER
- *
- * * * READ THE KEY BUFFER
- LDN 2 NUMBER OF CM WORDS
- STD ECS
- CALL READECS,PKEYECS
- *
- * * * IS THERE ROOM FOR THIS KEY
- LDM LKBUF+4 PPU INDEX IN KEY BUFFER
- SBM LKBUF+9 CPU INDEX IN KEY BUFFER
- ZJP SK1 JUMP IF NO KEYS IN BUFFER
- LPN 3 MASK INDEX FOR MOD 4
- ZJP SK5 IGNORE KEYS NO ROOM
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL RCHK
- *
- * * * BUMP PPU INDEX TO DETERMINE WHERE NEXT KEY GOES
- SK1 BSS 0
- AOM LKBUF+4 INCREMENT PPU INDEX
- LPN 3 MASK TO FIND BYTE INDEX
- STD D0 SAVE INDEX
- LDM KYBUFF GET NEW KEY
- STM LKBUF,D0 PLUG IN NEW KEY
- *
- * * * WRITE KEY BUFFER BACK TO ECS
- LDN 1 NUMBER OF CM WORDS
- STD ECS
- CALL WRITECS,PKEYECS
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL RCHK
- * /--- BLOCK SENDKEY 00 000 77/10/03 15.44
- *
- * * * COMPUTE INDEX FOR THIS STATION IN KEYS-IN BIT TAB.
- LDD TMSTAT
- SHN 18-5 DIVIDE BY 32
- STD ECSOFF SAVE WORD OFFSET
- SHN 5
- LPN 37B MASK FOR STATION NUMBER
- ADN 4 ADD BIAS TO STARTING BIT
- STD T1
- *
- * * * COMPUTE BYTE AND BIT POSITION IN THAT BYTE
- LDN 3
- STD SENDI BYTES 1-3 HAVE KEYS-IN BITS
- SK2 BSS 0
- LDD T1
- SBN 12
- MJP SK3 JUMP IF IN THIS BYTE
- STD T1
- SOD SENDI DECREMENT BYTE POINTER
- UJP SK2
- *
- * * * SET UP SHIFT INSTRUCTION TO POSITION BIT
- SK3 BSS 0
- LDM SKSHF
- LPC -77B MASK OFF OLD SHIFT COUNT
- ADD T1 ADD IN NEW SHIFT COUNT
- STM SKSHF
- *
- * * * POSITION BIT MASK AND SET UP MASKING INSTRUCTIONS
- LDN 1
- SKSHF BSS 0
- SHN 0 POSITION BIT WITHIN BYTE
- STM SKAND LOGICAL PRODUCT INSTRUCTION
- STM SKXOR LOGICAL DIFFERENCE INSTRUCTION
- *
- * * * READ KEYS-IN WORD ( 1 WORD)
- CALL READECS,PECSIN
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL RCHK
- *
- * * * CHECK FOR BIT ALREADY SET
- SK4 BSS 0
- LDM LKBUF,SENDI
- LPC 0 MASK BIT
- SKAND EQU *-1
- NJP SK5 EXIT IF ALREADY SET
- *
- * * * SET BIT
- LDM LKBUF,SENDI
- LMC 0
- SKXOR EQU *-1
- STM LKBUF,SENDI
- *
- * * * MARK LOWEST BYTE FOR REREAD
- LDM FRAMID
- STM LKBUF+4
- *
- * * * WRITE BACK TO ECS
- CALL WRITECS,PECSIN
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL RCHK
- *
- * * * READ BACK AND CHECK FOR CPU CONFLICT
- CALL READECS,PECSIN
- LDM LKBUF+4
- SBM FRAMID
- NJP SK4 JUMP IF CONFLICT OCCURRED
- *
- * * * INITIALIZE KYBUFF
- SK5 BSS 0
- LDC 7777B
- STM KYBUFF
- LJM SENDKEYX
- * /--- BLOCK GETFRAM 00 000 77/10/03 15.45
- TITLE GET FRAMES FROM ECS
- *
- * * GETFRAM
- *
- * WHEN A STATION IS USING TERMINAL MODE THE
- * FRAMER DIRECTS ALL OF ITS OUTPUT TO A SPECIAL
- * SET OF FRAMES. EACH FRAME IN THIS BUFFER (LFRBUF)
- * IS 4 WORDS LONG AND HAS A CORRESPONDING
- * ENTRY IN ASSOCIATED TABLE (LFRLTHS) WHICH GIVES
- * THE NUMBER OF TERMINAL FRAMES IN THE FRAME
- * WAITING TO BE OUTPUT. THE LINK DRIVER MARKS
- * THE FRAME THAT IT WILL LOOK AT NEXT BY
- * INCREMENTING LFRPNT. THE BOTTOM SEVEN BITS
- * OF THIS POINTER ARE THE FRAME INDEX. THIS
- * ROUTINE MOVES THE TERMINAL FRAMES FROM
- * THE FRAME BUFFER INTO THE LINK DRIVER OUTPUT
- * BUFFER FOR LATER TRANSMISSION.
- *
- *
- GETFRAM SUBR
- *
- * * * SAVE CURRENT FRAME POINTER
- LDM IFRAME+4
- STM IFRAMEX
- *
- * * * BUMP PPU FRAME POINTER, ALSO MOVES TO LKBUF
- CALL AFIVE,IFRAME
- *
- * * * WRITE IT TO ECS
- LDN 0
- STD ECSOFF
- LDN 1
- STD ECS NUMBER OF WORDS TO WRITE
- CALL WRITECS,LFRPNT
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL RCHK
- * /--- BLOCK GETFRAM 00 000 77/10/03 15.45
- *
- * * * ISOLATE FRAME INDEX
- LDM IFRAMEX
- LPC 177B 128 FRAMES
- STD ECSOFF
- *
- * * * READ FRAME LENGTH
- CALL READECS,LFRLTHS
- LDM LKBUF+4
- ZJN GETFRAMX IF FRAME IS EMPTY
- STD ECS SAVE FRAME COUNT
- *
- * * * SERVICE COMMUNICATION EQUIPMENT
- CALL RCHK
- *
- * * * CALCULATE OFFSET OF FRAME IN FRAME BUFFER
- LDD ECSOFF FRAME NUMBER
- SHN 2 4 WORDS PER FRAME
- STD ECSOFF
- *
- * * * READ FRAME FROM ECS
- CALL READECS,LFRBUF
- *
- * * * CALCULATE POSITION OF LAST FRAME IN LKBUF
- * (NEW ECS) = ((OLD ECS)-1)*5
- LDD ECS NUMBER OF FRAMES
- SBN 1 ADJUST SO 1 EQUALS ZERO OFFSET
- STD ECS SAVE NO. OF FRAMES - 1
- SHN 2 MULTIPLE BY 4
- RAD ECS
- *
- * * * MOVE NEW FRAME TO OUTPUT BUFFER
- LDD FRAME LOAD CHARACTER POSITION
- SHN -1 DIVIDE BY TWO, WORD POSITION
- STD TT SAVE
- LDM LKBUF,ECS GET 1ST BYTE OF FRAME
- STM ISTART,TT MOVE TO OUTPUT BUFFER.
- LDM LKBUF+1,ECS GET 2ND BYTE OF FRAME
- STM ISTART+1,TT MOVE IT TO THE OUTPUT BUFFER
- *
- * * * MOVE POINTER TO NEXT AVAILABLE SPOT.
- LDD FRAME GET POINTER
- ADN CHPF FOUR CHARACTERS/FRAME
- LPC TMASK KEEP MOD 128
- STD FRAME
- LJM GETFRAMX
- *
- * /--- BLOCK KYMOVE 00 000 77/10/03 14.22
- TITLE MOVE KEY
- *
- * * KYMOVE
- *
- * THIS ROUTINE IS CALLED IF -KYBUFF- IS EMPTY
- * (KYBUFF=4XXX). ITS FUNCTION IS TO MOVE THE
- * NEXT KEY FROM THE INPUT BUFFER TO -KYBUFF-.
- * THIS CAN ONLY BE DONE WHEN THERE IS IN FACT
- * A COMPLETE KEY ASSEMBLED IN THE INPUT
- * BUFFER.
- *
- KYMOVE SUBR
- *
- * * * IS THERE A COMPLETE KEY IN THE -DBUFF-.
- LDD KEY OUTPUT POINTER
- SHN -1 DIVIDE BY TWO CHARS/FRAME
- STD TT
- LDD ULP NUMBER OF CHARACTERS INPUT
- SHN -1 DIVIDE BY TWO
- SBD TT SUBTRACT OUTPUT POINTER
- ZJN KYMOVEX IF NO KEY
- *
- * * * MOVE NEXT KEY TO -KYBUFF-
- LDM OSTART,TT GET NEW KEY
- STM KYBUFF
- *
- * * * ADJUST OUTPUT POINTER TO NEXT FRAME POSITION
- LDD KEY GET CURRENT VALUE
- ADN CHPK TWO CHARACTERS/FRAME
- LPC TMASK MOD 512
- STD KEY SAVE NEW VALUE
- UJN KYMOVEX
- * /--- BLOCK TMSTART 00 000 78/01/04 21.48
- EJECT
- *
- * * TMSTART
- *
- TMSTART SUBR
- *
- * * * SET MODE TO TERMINAL MODE AND STATUS COUNT
- LDN 1
- STD MODE
- STD NC
- *
- * * * INITIALIZE PACKING AND UNPACKING VARIABLES
- LDN 0
- STD WP
- STD WU
- STD ULU
- STD ULP
- STD KEY
- STD FRAME
- STD TIME
- STD CLK
- STM CLKU
- STM CLKL
- LDC ALSEVEN
- STD NW
- *
- * * * SET TERMINAL MODE STATION.
- LDM XTMSTAT
- STD TMSTAT
- *
- * * * SET FRAM ID NUMBER
- LDM XFRAMID
- STM FRAMID
- *
- * * * SAVE NO. OF TERMINAL WORDS IN FRAME
- LDM XLFRLTH
- STM LFRLTH
- *
- * * * SET -FORINIP- ECS ADDRESS
- LDM ECL LOWER ECS RA
- ADC XFORINIP ADD RELATIVE ADDRESS
- STM FORINIP+1
- SHN -12
- ADM ECU ADD IN UPPER ECS RA
- STM FORINIP
- *
- * * * SET UP ECS ADDRESS TABLE
- LDN 0
- STD T1 POINTER TO ADDRESS TABLE
- STD T2 POINTER TO INPUT BUFFER
- TMS1 BSS 0
- LDM XPKEYEC+1,T2 LOWER 12 BITS OF ECS ADDRESS
- ADM ECL LOWER 12 BITS OF ECS RA
- STM ECSAD+1,T1
- SHN -12
- ADM ECU UPPER 9 BITS OF ECS RA
- ADM XPKEYEC,T2 UPPER 9 BITS OF ECS ADDRESS
- STM ECSAD,T1
- LDN 5
- RAD T2 BUMP POINTER TO INPUT BUFFER
- LDN 2
- RAD T1 BUMP POINTER TO ADDRESS TABLE
- SBN ECSLTH SUBTRACT LENGTH OF TABLE
- MJN TMS1 JUMP IF MORE TO DO
- *
- * * * CLEAR IN/OUT POINTERS FOR LINK TO FRAMER BUFFER
- CALL LCLEAR,10 CLEAR FIRST 10 BYTES OF LKBUF
- LDN 2
- STD ECS WRITE 2 CM WORDS
- LDN 0
- STD ECSOFF NO OFFSET
- CALL WRITECS,LKIN CLEAR POINTERS
- *
- * * * INITIALIZE LOCAL FRAME POINTER
- LDN 1
- STD ECS TRANSFER 1 WORD
- CALL READECS,LFRPNT
- *
- * * * MOVE FRAME POINTER TO LOCAL BUFFER
- LDN 4
- STD T1
- TMS3 BSS 0
- LDM LKBUF,T1
- STM IFRAME,T1
- SOD T1
- PJN TMS3 JUMP IF MORE TO MOVE
- LJM TMSTARTX
- * /--- BLOCK TMIN 00 000 77/08/17 14.05
- TITLE TERMINAL MODE INPUT-OUTPUT
- *
- * * TMIN
- *
- * THIS ROUTINE PROCESSES INPUT FROM THE 311 AND
- * PACKS IT INTO -XBUFF-. IF THIS SYSTEM IS
- * THE REMOTE SYSTEM INPUT WILL BE KEYS, WHILE
- * A LOCAL SYSTEM WILL INPUT OUTPUT FRAMES.
- * EXIT PARAMETERS
- * (A) WITH BE NEGATIVE IF CHARACTER WAS SYNC CODE.
- * (A) WITH BE POSITIVE IF ANY OTHER CHARACTER.
- *
- TMIN SUBR
- LDN 0
- STD TIME CLEAR TIMEOUT COUNTER
- *
- * * * PROCESS INPUT
- CALL GETCHR
- MJN TMINX IF SYNC CODE
- *
- * * * CHECK OUT OF SEQUENCE
- LDD ULP
- LPC 1 THIS MASK IS SET TO 1 OR 3 BY
- TIMK EQU *-1 -TLSET- OR -RTLSET-.
- ADN 3 SET BIT 2 IF 1, 2 OR 3
- SHN 3 POSITION START BIT MASK
- LMD CHAR MASK CHARACTER
- SHN 12 WAS BIT CORRECT
- PJN TMINX
- *
- * * * CHECK WHERE IN BYTE THIS CHARACTER SHOULD GO
- TM1 BSS 0
- AOD ULP
- LPN 1
- ZJN TM2 JUMP IF LOWER CHARACTER
- AOD WP ADVANCE WORD POINTER.
- *
- * * * PUT NEW CHAR. INTO UPPER CHAR. POSITION
- LDD CHAR
- LPN 37B
- SHN 5
- STM OSTART-1,WP STORE IN BUFFER
- UJN TM3
- *
- * * * STORE NEW CHAR. IN LOWER CHAR. POSITION
- TM2 BSS 0
- LDD CHAR
- LPN 37B
- RAM OSTART-1,WP STORE INTO BUFFER
- *
- * * * HAVE WE REACHED THE END OF THE BUFFER
- TM3 BSS 0
- LDD ULP
- LPC TMASK
- NJN TM4 IF STILL ROOM
- STD WP OTHERWISE START AT BEGINNING
- STD ULP
- TM4 LJM TMINX
- * /--- BLOCK TMOUT 00 000 76/06/11 15.52
- EJECT
- *
- * * TMOUT
- *
- * THIS ROUTINE HANDLES 311 OUTPUT DURING TERMINAL
- * MODE OPERATION. THE OUTPUT WILL BE KEYS IF AT
- * THE LOCAL SYSTEM, WHILE FRAMES WILL BE OUTPUT
- * IF AT THE REMOTE SYSTEM. THE DATA IS UNPACKED
- * FROM -DBUFF- AND SENT 6 BITS AT A TIME.
- *
- TMOUT SUBR
- *
- * * * IS NEXT CHAR. TO BE TAKEN FROM UPPER OR LOWER
- AOD ULU
- LPN 1
- ZJN TO1 JUMP IF LOWER
- *
- * * * BUMP TO NEXT WORD IN BUFFER.
- AOD WU
- *
- * * * ISOLATE UPPER 5 BITS.
- LDM ISTART-1,WU
- SHN 13
- UJN TO2
- *
- * * * GET LOWER FIVE BITS IN WORD
- TO1 BSS 0
- LDM ISTART-1,WU
- *
- * * * ISOLATE FIVE BIT PACKAGE
- TO2 BSS 0
- LPN 37B
- ADC DCON
- STD OC
- *
- * * * ADD START BIT IF STARTING CHAR. OF FRAME OR KEY
- LDD ULU
- SBN 1
- LPC 1 'THIS MASK SET TO 1 OR 3 BY
- TOMK EQU *-1 -TLSET- OR -RTLSET-.
- NJN TO3
- *
- * * * ADD START BIT
- LDN 40B
- RAD OC
- *
- * * * SEND THIS CHARACTER
- TO3 BSS 0
- LDM PARTBLE,OC GET PARITY BIT
- CALL OCHR
- *
- * * * IF AT END OF BUFFER SET POINTER TO BEGINNING
- LDD ULU
- LPC TMASK MODULO 1024
- NJN TO4 IF NOT AT END
- STD WU RESET POINTER TO FIRST WORD.
- STD ULU
- TO4 LJM TMOUTX
- * /--- BLOCK READECS 00 000 77/08/29 15.26
- TITLE READ ECS
- *
- * * READECS
- *
- * READ ECS USING CPU MONITOR CALL, WHICH TRANSFERS
- * DATA TO CM (TRNBF) WHERE THE PPU CAN THEN READ IT.
- *
- * INPUT PARAMETERS';
- * (A) - POINTER TO ECS ADDRESS
- * (ECS) - NUMBER OF CM WORDS (1-60D)
- * (ECSOFF) - OFFSET TO ADD TO BASE ECS ADDRESS
- *
- * OUTPUT PARAMETERS';
- * (LKBUF) - DATA READ FROM ECS
- * (A) = ZERO - TRANSFER OKAY
- * = NONZERO - ECS ERROR
- *
- *
- READECS SUBR
- *
- * * * SAVE ADDRESS OF ECS ADDRESS
- STD TT
- *
- LDK ZERL (A) = CM ADDR OF ZERO WORD
- CRD CM CLEAR LIST ENTRY
- LDM 1,TT LOWER 12 BITS OF ADDRESS
- ADD ECSOFF ADD OFFSET
- STD CM+4
- SHN -12 SAVE ADD OVERFLOW
- ADM 0,TT UPPER 9 BITS OF ADDRESS
- STD CM+3
- .NOSV2 IFLT OSLEV,562D IF NOS V1
- LDD MA
- CWD CM (MB) = 36/TRASH,24/EM ADDRESS
- *
- * * * PUT SUBFUNCTION AND R/W CODES INTO REQUEST
- LDN 0
- STD CM+4 (CM+4) = R/W CODE (READ)
- LDC /CPS/RWEM*1000B
- STD CM+3 (CM+3) = SUBFUNCTION = *RWEM*
- *
- * * * PUT CM ADDRESS AND NO. OF WORDS INTO REQUEST
- LOADCM TRNBF GET CM ADDRESS
- STD CM+2 STORE LOWER 12 BITS
- SHN -12 POSITION TOP 6 BITS
- STD CM+1
- LDD ECS NO. OF WORDS MINUS ONE
- SBN 1 ADJUST COUNT FOR THIS REQUEST
- SHN 6
- RAD CM+1 ADD TO REQUEST
- .NOSV2 ELSE IF NOS V2
- LDD ECS (A) = NUM OF CPU WORDS TO READ
- SHN 6
- STD CM+1 (CM+1) = CPU WORDS TO READ
- LOADCM TRNBF (A) = CM ADDRESS OF LIST
- CWD CM UPDATE LIST (1 ENTRY)
- LDK ZERL (A) = CM ADDR OF ZERO WORD
- CRD CM CLEAR REQUEST WORD
- LDN 1 (A) = ONE LIST ENTRY TO PROCESS
- SHN 6
- STD CM+1 (CM+1) = NUMBER OF LIST ENTRIES
- LOADCM TRNBF (A) = CM ADDRESS OF LIST
- STD CM+2 (CM+2) = LOWER PART OF LIST ADR
- SHN -12D POSITION UPPER PART OF LIST ADR
- LPN 77B (A) = UPPER PART W/OUT SIGN EXT
- RAD CM+1 (CM+1) NOW INCLUDES UPPER PART
- * SET THE SUBFUNCTION (*PELS*), READ EM, AND
- * ABSOLUTE SYSTEM EM ADDRESS.
- LDK /CPS/PELS*1000B (A) = SUBFUNCTION = *PELS*
- STD CM+3
- .NOSV2 ENDIF
- *
- * * * READ ECS TO CM
- MONITOR ECSM READ ECS TO CM
- LDD CM+1
- * /--- BLOCK READECS 00 000 84/11/15 11.34
- NJP READECSX IF EM ERROR
- *
- * * * READ CM TO PPU
- LOADCM TRNBF CM LOCATION OF DATA
- .NOSV2 IFGE OSLEV,562D IF NOS V2
- ADN 1 SKIP THE LIST
- .NOSV2 ENDIF
- CRM LKBUF,ECS
- LDN 0
- LJM READECSX
- * /--- BLOCK WRITECS 00 000 77/08/29 15.27
- TITLE WRITE ECS
- *
- * * WRITECS
- *
- * WRITE ECS USING CPU MONITOR CALL. THE DATA
- * IS TRANSFERRED TO A CM BUFFER (TRNBF) BY THE
- * PPU, THEN TO ECS USING THE MONITOR CALL.
- *
- * INPUT PARAMETERS';
- * (A) - POINTER TO ECS ADDRESS
- * (ECS) - NUMBER OF CM WORDS (1-64)
- * (ECSOFF) - OFFSET TO ADD TO BASE ECS ADDRESS
- * (LKBUF) - DATA TO BE WRITTEN
- *
- * OUTPUT PARAMETERS';
- * (A) = ZERO - TRANSFER OKAY
- * = NONZERO - ECS ERROR
- *
- * MONITOR REQUEST FORMAT
- * / REQUEST CODE / NNCC / CCCC / REEE / EEEE/
- * N - NUMBER OF CM WORDS MINUS ONE.
- * C - CM BUFFER ADDRESS
- * R - READ/WRITE CODE (READ = 2, WRITE = 3)
- * E - ECS ADDRESS
- *
- *
- WRITECS SUBR
- *
- * * * SAVE ADDRESS OF ECS ADDRESS
- STD TT
- * * * PUT ECS ADDRESS INTO REQUEST
- LDK ZERL (A) = CM ADDR OF ZERO WORD
- CRD CM CLEAR LIST ENTRY
- LDM 1,TT LOWER 12 BITS OF ADDRESS
- ADD ECSOFF ADD OFFSET
- STD CM+4
- SHN -12 SAVE ADD OVERFLOW
- ADM 0,TT UPPER 9 BITS OF ADDRESS
- STD CM+3
- .NOSV2 IFLT OSLEV,562D IF NOS V1
- LDD MA
- CWD CM (MB) = 36/TRASH,24/EM ADDRESS
- *
- * * * PUT SUBFUNCTION AND R/W CODES INTO REQUEST
- LDN 1
- STD CM+4 (CM+4) = R/W CODE (WRITE)
- LDC /CPS/RWEM*1000B
- STD CM+3 (CM+3) = SUBFUNCTION = *RWEM*
- *
- * * * PUT CM ADDRESS AND NO. OF WORDS INTO REQUEST
- LOADCM TRNBF GET CM ADDRESS
- STD CM+2 STORE LOWER 12 BITS
- SHN -12 POSITION TOP 6 BITS
- STD CM+1
- LDD ECS NO. OF WORDS
- SBN 1 ADJUST COUNT FOR THIS REQUEST
- SHN 6
- RAD CM+1 ADD TO REQUEST
- .NOSV2 ELSE IF NOS V2
- LDD ECS (A) = NUM OF CPU WORDS TO READ
- SHN 6
- STD CM+1 (CM+1) = CPU WORDS TO READ
- LOADCM TRNBF (A) = CM ADDRESS OF LIST
- CWD CM UPDATE LIST (1 ENTRY)
- LDK ZERL (A) = CM ADDR OF ZERO WORD
- CRD CM CLEAR REQUEST WORD
- LDN 1 (A) = ONE LIST ENTRY TO PROCESS
- SHN 6
- STD CM+1 (CM+1) = NUMBER OF LIST ENTRIES
- LOADCM TRNBF (A) = CM ADDRESS OF LIST
- STD CM+2 (CM+2) = LOWER PART OF LIST ADR
- SHN -12D POSITION UPPER PART OF LIST ADR
- LPN 77B (A) = UPPER PART W/OUT SIGN EXT
- RAD CM+1 (CM+1) NOW INCLUDES UPPER PART
- * /--- BLOCK WRITECS 00 000 77/08/29 15.27
- * SET THE SUBFUNCTION (*PELS*), WRITE EM, AND
- * ABSOLUTE SYSTEM EM ADDRESS.
- LDK /CPS/PELS*1000B+1S8 (A) = *PELS* + WRITE EM
- STD CM+3 (CM+3) = SUBFUNCTION
- .NOSV2 ENDIF
- *
- * * * WRITE PPU TO CM BUFFER
- LOADCM TRNBF CM LOCATION OF DATA
- .NOSV2 IFGE OSLEV,562D IF NOS V2
- ADN 1 SKIP THE LIST
- .NOSV2 ENDIF
- CWM LKBUF,ECS
- *
- * * * WRITE FROM CM TO ECS
- MONITOR ECSM READ ECS TO CM
- LDD CM+1
- LJM WRITECSX
- * /--- BLOCK CLOCK 00 000 77/08/26 16.41
- TITLE CLOCK
- *
- * * CLOCK
- *
- * UPDATES RUNNING CLOCK IN CLKU AND CLKL
- * THIS ROUTINE MUST BE DONE AT LEAST ONCE EVERY
- * 4 MILLISECONDS.
- *
- * INPUT PARAMETERS';
- * (A) = NUMBER OF MILLISECONDS AT WHICH TO TIME OUT
- *
- * OUTPUT PARAMETERS';
- * (A) - NONZERO HAVE NOT REACH TIME OUT TIME
- * ZERO TIME OUT TIME HAS BEEN REACHED
- *
- CLOCK SUBR
- STD TT SAVE INPUT PARAMETE
- *
- * * * READ MICROSECOND CLOCK
- IAN 14B
- *
- * * * SAVE NEW INFO AND COMPARE TO LAST READING
- STD D0
- SBD CLK LAST READING
- PJN CLOCK1 JUMP IF NO WRAP AROUND
- *
- * * * CLOCK HAS WRAPPED AROUND RECALCULATE DIFFERENCE
- ADC 10000B
- *
- * * * UPDATE RUNNING TIME
- CLOCK1 BSS 0
- SHN 2 ADJUST TO GET MS IN UPPER CELL
- RAM CLKL LOWER 12 BITS OF CLOCK
- SHN -12
- RAM CLKU UPPER 12 BITS
- *
- * * * REPLACE OLD CLOCK READING WITH NEW ONE
- LDD D0
- STD CLK
- *
- * * * IS IT TIME TO TIME OUT
- LDM CLKU
- SBD TT
- MJN CLOCKX
- *
- * * * TIME OUT -- CLEAR THE CLOCK
- LDN 0
- STM CLKU
- STM CLKL
- UJN CLOCKX
- * /--- BLOCK READCM 00 000 77/08/17 09.26
- TITLE READ AND CLEAR PPU COMMUNICATIONS SWITCH
- * READSW
- *
- * THIS ROUTINE READS THE SWITCH FROM THE
- * CM COMUNICATIONS BUFFER AND SAVES THE LAST BYTE
- * IN -A-.
- *
- READSW1 LDD CM+4
- READSW SUBR
- LOADCM COMBF PRESET TO 1ST WORD OF CM
- * COMMUNICATION BUFFER.
- CRD CM READ OUTPUT DATA REQUEST SWITCH
- LDD CM+4
- ADC -MAXCM IS READ TOO LARGE
- MJN READSW1 IF READ LENGTH OK
- CALL SERROR,SCML
- SPACE 4
- * READ
- *
- * THIS ROUTINE READS THE REQUEST PARAMETERS
- * FROM THE PARAMETER SECTION OF THE CM
- * COMMUNICATION BUFFER TO -IBF- AND THE DATA
- * PORTION TO -IHDR-.
- *
- READ SUBR
- READ1 LOADCM COMBF PRESET TO 1ST WORD OF CM
- * COMMUNICATION BUFFER.
- ADN PPOS ADJUST TO PARAMETER SECTION.
- CRM IBF,LT READ INTO PPU
- *
- * * * MOVE NEW PARAMETER SECTION TO OUTPUT BUFFER.
- *
- LDN IHDR-IBF-1 BYTES TO MOVE.
- STD D0
- READ2 BSS 0
- LDM IBF,D0
- STM OBF,D0
- SOD D0
- PJP READ2 JUMP IF NOT FINISHED.
- UJN READX
- * /--- BLOCK WRITE 00 000 77/08/17 15.04
- TITLE WRITE TO CM BUFFER.
- * WRITE
- *
- * THIS ROUTINE WRITES DATA RECEIVED OVER
- * LINK, PLUS ANY ERROR CODES OR STATUS TO A
- * CM BUFFER.
- * THE TOP BIT OF THE SWITCH IS SET TO 1 AND THE
- * NEXT-TO-LAST BYTE IS SET TO THE NUMBER OF CM
- * WORDS IN THIS RESPONSE.
- *
- * INPUT PARAMETER
- * (DL) = NUMBER OF CM WORDS OF DATA
- *
- *
- WRITE SUBR
- WTE1 BSS 0
- LDN PLTH LENGTH OF PARAMETER SECTION.
- ADD DL PLUS NUMBER OF DATA WORDS.
- STD D0
- WRITE1 LOADCM COMBF PRESET TO 1ST WORD OF CM
- * COMMUNICATION BUFFER.
- ADN PPOS ADJUST TO PARAMETER SECTION.
- CWM OBF,D0 WRITE TO CM.
- LDN ZERL CLEAR BUFFER
- CRD CM
- LDC 4000B SIGN BIT SET
- STD CM
- LDD D0
- STD CM+3 SET NO. OF RESPONSE WORDS.
- WRITE2 LOADCM COMBF PRESET TO 1ST WORD ADDRESS OF
- * PARAMETER BUFFER IN CM.
- CWD CM WRITE SWITCH
- LDN 0
- STD DL CLEAR DATA WORD COUNT
- *
- * * * PRESS KEY ON LESSON TO INDICATE REQUEST IS DONE.
- LDC LAB1K LAB1 TO BE PRESSED
- STM RQKEY
- CALL PREQ,PKEY
- UJN WRITEX
- * /--- BLOCK I/O CHAR 00 000 78/01/22 17.15
- TITLE CHARACTER I/O
- *
- * * ICHR
- *
- * THIS ROUTINE INPUTS ONE BYTE OF INFORMATION
- * FROM THE EVEN CHANNEL OF THE 311.
- *
- ICHR SUBR
- RJM CCR
- NJN ICHR1 IF EQUIP/CHANNEL RESERVED
- CALL SERROR,SENA
- ICHR1 BSS 0
- PORT EVEN
- FNC DCIC,C=CH SELECT 6681 INPUT
- ACN C=CH,40B ACTIVATE THE CHANNEL
- WAIT FULL,C=CH,ICHR10
- IAN C=CH,40B INPUT BYTE OF DATA
- DCN C=CH,40B DE-ACTIVATE THE CHANNEL
- UJN ICHRX
- *
- ICHR10 CALL CTIMEO PROCESS CHANNEL TIME-OUT
- UJN ICHRX
- SPACE 4
- *
- * * OCHR
- *
- * THIS ROUTINE OUTPUTS ONE BYTE OF INFORMATION
- * TO THE EVEN CHANNEL OF THE 311.
- *
- OCHR SUBR
- STD T1 SAVE (A)
- RJM CCR
- NJN OCHR1 IF EQUIP/CHANNEL RESERVED
- CALL SERROR,SENA
- OCHR1 LDD T1 RESTORE (A)
- PORT EVEN
- FNC DCOC,C=CH SELECT 6681 OUTPUT
- ACN C=CH,40B ACTIVATE THE CHANNEL
- OAN C=CH,40B OUTPUT DATA
- WAIT EMPTY,C=CH,OCHR10
- DCN C=CH,40B DE-ACTIVATE THE CHANNEL
- UJN OCHRX
- *
- OCHR10 CALL CTIMEO PROCESS CHANNEL TIME-OUT
- UJN OCHRX
- * /--- BLOCK I/O CHAR 00 000 78/01/22 18.41
- EJECT
- *
- * * ICHR2
- *
- * THIS ROUTINE INPUTS ONE BYTE OF INFORMATION
- * FROM THE ODD CHANNEL OF THE 311.
- *
- ICHR2 SUBR
- RJM CCR
- NJN ICHR3 IF EQUIP/CHANNEL RESERVED
- CALL SERROR,SENA
- ICHR3 BSS 0
- PORT ODD
- FNC DCIC,C=CH SELECT 6681 INPUT
- ACN C=CH,40B ACTIVATE THE CHANNEL
- WAIT FULL,C=CH,ICHR20
- IAN C=CH,40B INPUT BYTE OF DATA
- DCN C=CH,40B DE-ACTIVATE THE CHANNEL
- STD PS SAVE STATUS
- UJN ICHR21
- *
- ICHR20 CALL CTIMEO PROCESS CHANNEL TIME-OUT
- ICHR21 UJN ICHR2X
- SPACE 4
- *
- * * OCHR2
- *
- * THIS ROUTINE OUTPUTS ONE BYTE OF INFORMATION
- * TO THE ODD CHANNEL OF THE 311.
- *
- OCHR2 SUBR
- STD T1 SAVE (A)
- RJM CCR
- NJN OCHR3 IF EQUIP/CHANNEL RESERVED
- CALL SERROR,SENA
- OCHR3 LDD T1 RESTORE (A)
- PORT ODD
- FNC DCOC,C=CH SELECT 6681 OUTPUT
- ACN C=CH,40B ACTIVATE THE CHANNEL
- OAN C=CH,40B OUTPUT DATA
- WAIT EMPTY,C=CH,OCHR20
- DCN C=CH,40B DE-ACTIVATE THE CHANNEL
- UJN OCHR21
- *
- OCHR20 CALL CTIMEO PROCESS CHANNEL TIME-OUT
- OCHR21 UJN OCHR2X
- SPACE 4
- *
- * * CTIMEO
- *
- * THIS ROUTINE ISSUES A DAYFILE MESSAGE FOR A
- * CHANNEL TIME-OUT AND DROPS THE PPU IF THE PPU IS
- * NOT ALREADY IN THE PROCESS OF DROPPING.
- *
- CTIMEO SUBR
- CALL DFM,CTOMSG OUTPUT TIME-OUT MESSAGE
- LDM DPPF CHECK IF ALREADY DROPPING PPU
- NJN CTIMEOX
- UJP DPP
- *
- CTOMSG DIS ,*(CLD) CHANNEL TIME-OUT*
- *
- SPACE 3
- *
- * * CCR
- *
- * THIS ROUTINE CHECKS IF THE 3266 EQUIPMENT AND
- * CHANNEL HAVE BEEN RESERVED BEFORE ATTEMPTING TO
- * DO ANYTHING WITH IT. ON EXIT, (A) = 0 IF EITHER
- * THE EQUIPMENT OR CHANNEL IS NOT RESERVED, NON-
- * ZERO OTHERWISE.
- *
- CCR SUBR
- LDC ALSEVEN
- LMM CLEQ
- ZJN CCRX IF EQUIPMENT NOT RESERVED
- LDC ALSEVEN
- LMM CLCH
- ZJN CCRX IF CHANNEL NOT RESERVED
- LDN 1
- UJN CCRX
- * /--- BLOCK WCR 00 000 76/05/13 14.23
- TITLE WAIT CHARACTER READY OR REQUEST
- *
- * * WCR
- *
- * THIS ROUTINE WAITS FOR THE SPECIFIED STATUS
- * TO APPEAR OR UNTIL IT HAS CHECK THE STATUS
- * THE SPECIFIED NUMBER OF TIMES.
- *
- * INPUT PARAMETERS
- * (A) = MASK FOR REQUIRED STATUS
- * (NC) = NUMBER OF STATUS CHECKS TO BE PERFORMED.
- *
- * OUTPUT PARAMETERS
- * (A) = 0 STATUS DID NOT APPEAR.
- * 1 INDICATED STATUS APPEARED
- * (CHAR) = INPUT BYTE
- *
- WCR SUBR
- *
- * * * SAVE SPECIFIED MASK
- STM WRM
- *
- * * * GET NUMBER OF TIMES TO CHECK
- LDD NC
- STD D0
- *
- * * * CHECK IF TIME TO CHECK FOR STORAGE RELOCATION
- WR1 BSS 0
- SOD TI
- NJN WR2 JUMP IF NOT TIME TO CHECK
- RJM PAUSE CHECK FOR STORAGE RELOCATION
- RJM DROPCHK CHECK FOR DROP SIGNAL
- *
- * * * INPUT STATUS
- WR2 BSS 0
- RJM ICHR
- STD CHAR SAVE INPUT
- *
- * * * CHECK FOR SPECIFIED STATUS
- LPC *
- WRM EQU *-1
- NJN WCRX IF STATUS APPEARED
- *
- * * * STATUS CHECK DONE, IF SO CHECK ODD CHANNEL STATUS
- SOD D0
- NJN WR1 JUMP IF NOT
- *
- * * * IF TERMINAL MODE, DO TIME OUT CHECK
- LDD MODE
- ZJN WCRX IF DATA MODE
- AOD TIME NUMBER OF CHECKS MADE FOR INPUT
- ADC -ALSEVEN MAXIMUM CHECKS TO MAKE
- ZJP LOSTC JUMP IF CONTACT LOST
- LDN 0
- UJN WCRX
- * /--- BLOCK WCPE-PUTCH 00 000 76/05/17 11.08
- TITLE ODD CHANNEL STATUS/PUT CHARACTER
- *
- * * WCPE
- *
- * THIS ROUTINE INPUTS THE ODD CHANNEL STATUS
- * AND CHECKS FOR CHARACTER PHASE ESTABLISHED.
- *
- * OUTPUT PARAMETERS
- * IF (A) = ZERO CHARACTER PHASE NOT ESTABLISHED
- * = POSITIVE - ESTABLISHED SYNCHRONIZATION
- *
- WCPE SUBR
- *
- * * * INPUT STATUS
- CALL ICHR2
- *
- * * * CHECK CARRIER BIT
- LPC MCST
- NJN WP1 JUMP IF CARRIER NOT ON
- *
- * * * CHECK FOR STATUS BIT
- LDD PS
- LPC MCPH
- LMC MCPH
- UJN WCPEX
- *
- * * * ERROR--CARRIER NOT ON.
- WP1 BSS 0
- CALL HERROR,HCNO
- SPACE 1
- *
- * * PUTCHR
- *
- * WAIT FOR CHARACTER REQUEST STATUS TO APPEAR THEN
- * OUTPUT THE INDICATED CHARATER.
- *
- * INPUT PARAMETER
- * (A) = CHARACTER TO BE OUTPUT.
- *
- PUTCHR SUBR
- *
- * * * SAVE CHARACTER TO BE OUTPUT
- STD OC
- *
- * * * WAIT FOR CHARACTER REQUEST STATUS
- LDC MCRQ
- RJM WCR
- *
- * * * OUTPUT CHARACTER
- LDM PARTBLE,OC
- RJM OCHR
- UJN PUTCHRX
- * /--- BLOCK GETCHR 00 000 78/05/11 22.15
- TITLE GETCHR
- *
- * * GETCHR
- *
- * THIS ROUTINE IS CALLED AFTER INPUT HAS
- * BEEN RECEIVED TO CHECK AND CLASSIFY IT.
- *
- * INPUT PARAMETERS
- * (CHAR) = INPUT BYTE.
- * OUTPUT PARAMETERS
- * (A) = -1 SYNC CODE
- * 0 DATA CHARATER RETURNED
- * 1 CONTROL CODE RETURNED
- *
- GETCHR SUBR
- *
- * * * SAVE ONLY CHARACTER INFO IN BYTE.
- LDD CHAR
- LPC MCHR8 MASK OFF STATUS BITS
- STD TT SAVE CHAR. PLUS PARITY BIT
- LPC MCHR7 MASK OFF PARITY BIT
- STD CHAR SAVE CHAR. MINUS PARITY BIT
- *
- * * * CHECK CHARACTER PARITY
- LDM PARTBLE,CHAR CHAR. PLUS CORRECT PARITY
- SBD TT WAS INPUT THE SAME
- NJP GC2 JUMP IF NOT
- *
- * * * FOUND GOOD CHAR. - CLEAR BAD CHARACTER COUNT
- LDN 0
- STD BADC
- *
- * * * CHECK FOR SYNC CHARACTER
- LDD CHAR
- SBN CSYN
- NJN GC1 JUMP IF NOT SYNC CODE.
- LCN 1
- UJN GETCHRX
- *
- * * * SET RETURN TO INDICATE DATA OR CONTROL CHAR.
- GC1 BSS 0
- LDD CHAR
- SHN -6 ONLY INDICATOR BIT REMAINS
- LMN 1 COMPLEMENT IT.
- UJN GETCHRX
- *
- * * * CHARACTER PARITY ERROR
- GC2 BSS 0
- AOM PECNT COUNT OF TOTAL BAD CHAR.
- STD NAKFLAG INDICATE MESSAGE HAS AN ERROR
- AOD BADC CONSECUTIVE BAD CHAR. COUNT
- SBN PEND CHECK FOR TOO MANY BAD CHAR.
- MJP GETCHRX IF NOT TOO MANY
- *
- * * * IF WAITING FOR LINKCTL COMMAND, SEND ERROR LATER
- LDM WAITF
- NJP WAITL JUMP IF WAITING ON COMMAND
- *
- * * * ERROR--TOO MANY BAD CHARACTERS
- CALL HERROR,HBCH
- * /--- BLOCK PACK 00 000 76/05/17 11.08
- TITLE PACK DATA
- *
- * * PACK
- *
- * THIS ROUTINE TAKES LAST CHARACTER INPUT AND
- * PACKS IT INTO THE NEXT PPU WORD IN THE INPUT
- * BUFFER. TWO CHARACTERS ARE PUT INTO EACH WORD
- * THUS IT HAS TO BE DETEMINED WHETHER THIS
- * CHARACTER IS TO BE PUT IN THE UPPER(BITS 6-11)
- * LOWER(BITS 0-5) POSITION IN THE CURRENT WORD.
- *
- PACK SUBR
- *
- * * * UPDATE MESSAGE PARITY CHECK
- *
- LDD CHAR INPUT CHARACTER
- LMD CKI MESSAGE PARITY
- STD CKI
- *
- * * * CHECK WHERE IN BYTE THIS CHARACTER SHOULD GO
- *
- AOD ULP
- LPN 1
- ZJN PK1 JUMP IF LOWER CHARACTER
- *
- * * * ADVANCE PPU WORD POINTER TO NEXT WORD
- *
- AOD WP
- *
- * * * CHECK FOR BUFFER OVERFLOW
- *
- ADC -MAXIN MAX. NO. OF BYTES TO ASSEMBLE
- MJN PK0 JUMP IF NO OVERFLOW
- *
- * * * ERROR--MESSAGE TOO LONG
- CALL HERROR,HMLT
- *
- * * * PUT NEW CHARACTER INTO UPPER CHARACTER POSITION
- * IN THIS PPU WORD.
- *
- PK0 BSS 0
- LDD CHAR INPUT CHARACTER
- SHN 6 POSITION CHARACTER
- STM OSTART-1,WP STORE IN BUFFER
- UJN PACKX GET NEXT WORD
- *
- * * * STORE NEW CHARACTER IN LOWER CHARACTER POSITION
- * OF PPU WORD.
- *
- PK1 BSS 0
- LDD CHAR INPUT CHARACTER
- LPN 77B GET RID OF DATA BIT
- RAM OSTART-1,WP STORE INTO DATA BUFFER
- UJN PACKX GET NEXT CHARACTER
- * /--- BLOCK UNPACK 00 000 77/08/17 14.01
- TITLE UNPACK
- *
- * * UNPACK
- *
- * THIS ROUTINE EXTRACTS ONE CHARACTER AT A TIME
- * FROM THE OUTPUT BUFFER(XBUFF) AND SAVES IT
- * IN -OC-. 'THE CHARACTERS ARE STORED TWO TO A
- * PPU WORD SO IT MUST DETERMINE WHETHER THE NEXT
- * CHARACTER IS IN THE UPPER(BITS 6-11) OR LOWER
- * (BITS 0-5) POSITION OF THE WORD.
- *
- * OUTPUT PARAMETER
- * (A) = NONZERO IF CHARACTER IN -OC-
- * = ZERO IF NO MORE CHARACTERS IN BUFFER.
- *
- UNPACK SUBR
- *
- * * * IS NEXT CHARACTER TO BE TAKEN FROM UPPER OR
- * LOWER PORTION OF PPU WORD.
- *
- AOD ULU
- LPN 1
- ZJN UPK1 JUMP IF LOWER
- *
- * * * CHECK TO SEE IF ALL DATA HAS BEEN OUTPUT
- *
- LDD WU CURRENT POSITION IN BUFFER
- SBD NW SUBTRACT LAST DATA POSITION
- ZJN UNPACKX IF ALL DONE
- AOD WU BUMP TO NEXT WORD
- *
- * * * ISOLATED NEXT CHARACTER FROM UPPER CHARACTER
- * POSITION OF PPU WORD.
- *
- LDM ISTART-1,WU
- SHN 12 POSITION CHARACTER IN LOWER
- * 6 BITS OF -A-
- UJN UPK2 GO MASK CHARACTER
- *
- * * * NEXT CHARACTER IN LOWER 6 BITS OF PPU WORD
- *
- UPK1 BSS 0
- LDM ISTART-1,WU
- *
- * * * ISOLATE CHARACTER, ADD DATA BIT, AND SAVE
- *
- UPK2 BSS 0
- LPN 77B
- ADC DCON ADD DATA BIT
- STD OC SAVE OUTPUT CHARACTER
- UJN UNPACKX
- * /--- BLOCK DATAIN 00 000 76/06/16 15.24
- TITLE DATAIN
- *
- *
- * * DATAIN
- *
- * THIS ROUTINE INPUTS DATA CHARACTERS SENT BY
- * THE REMOTE SITE AND PACKS THEM TWO CHARACTERS
- * PER BYTE INTO THE DATA BUFFER. THE DATA INPUT
- * IS TERMINATED BY AN -EOD-(END OF DATA), -EOB-
- * (END OF BLOCK), OR -EOF-(END OF FILE) CONTROL
- * CHARACTER, WHICH IS INTURN FOLLOWED BY THE
- * MESSAGE PARITY CODE.
- *
- DATAIN SUBR
- *
- * * * INITIALIZE POINTERS
- LDN 0
- STD ULP
- STD WP
- STD CKI
- STD NAKFLAG
- *
- * * * CLEAR SYNC CODE COUNTER
- DI1 BSS 0
- LDN 0
- STD SC
- *
- * * * WAIT FOR FIRST CHARATER
- DI2 BSS 0
- CALL WCR,MCRD
- ZJP LOSTC PROBABLY LOST CONTACT
- *
- * * * PROCESS INPUT CHARACTER
- RJM GETCHR
- MJN DI3 JUMP IF SYNC CODE
- NJN DI4 JUMP IF CONTROL CODE
- *
- * * * PUT DATA AWAY
- CALL PACK
- UJN DI1
- *
- * * * SYNC CODE INPUT, BUMP COUNTER, IF TOO MANY ARE
- * RECEIVED BEFOR NEXT DATA CHARACTER HAVE MESSAGE
- * RESENT.
- DI3 BSS 0
- AOD SC BUMP SYNC CODE COUNTER
- ADC -SYEND1 CHECK FOR TOO MANY SYNC CHAR.
- MJN DI2 GET NEXT CHAR. IF NOT
- UJP DI6 SET NAKFLAG AND EXIT
- * /--- BLOCK DATAIN 00 000 84/11/15 11.34
- *
- * * * CONTROL CODE RECEIVED, CHECK FOR -EOD-, -EOB-,
- * OR -EOF-.
- DI4 BSS 0
- LDN CEOD
- SBD CHAR
- ZJN DI5 JUMP IF -EOD-
- *
- LDN CEOB
- SBD CHAR
- ZJN DI5 JUMP IF -EOB-
- *
- LDN CEOF
- SBD CHAR
- ZJN DI5 JUMP IF -EOF-
- *
- * * * BAD CHARACTER SET NAKFLAG AND GET NEXT CHARACTER
- LDN 1
- STD NAKFLAG
- AOM BDCNT BUMP ERROR COUNT
- UJP DI2
- *
- * * * PUT CONTROL CODE IN -LINKCTL- RESPONSE.
- DI5 BSS 0
- LDD CHAR
- STM OHDR+REOM
- *
- * * * GET NUMBER OF PPU WORDS INPUT
- LDD WP
- STM RWDS+OHDR
- *
- * * * CALCULATE NUMBER OF CM WORDS IN MESSAGE
- ADN 4 EXTRA WORDS IN HEADER.
- CALL CMCAL
- *
- * * * INPUT MESSAGE PARITY CODE
- CALL WCR,MCRD WAIT FOR INPUT
- ZJP LOSTC JUMP IF LOST CONTACT
- *
- * * * PROCESS INPUT
- CALL GETCHR
- LDD CHAR
- *
- * * * COMPARE GENERATED PARITY TO ONE RECEIVED
- SBD CKI
- ZJN DI7
- *
- * * * SET NAKFLAG AND EXIT
- DI6 BSS 0
- LDN 1
- STD NAKFLAG
- AOM LPCNT BUMP ERROR COUNT
- DI7 LJM DATAINX
- * /--- BLOCK DATAOUT 00 000 76/06/16 14.54
- TITLE DATAOUT
- *
- * * DATAOUT
- *
- * THIS ROUTINE TRANSMITS DATA TO THE REMOTE
- * SITE. THE DATA IS GIVEN TO THE DRIVER BY
- * -LINKCTL-. THE DATA IS THEN UNPACKED A
- * CHARACTER AT A TIME AND TRANSMITTED. -LINKCTL-
- * ALSO SUPPLIES THE CONTROL CODE WHICH WILL
- * FOLLOW THIS MESSAGE(EOD, EOB, OR EOF). THIS
- * ROUTINE ALSO GENERATES A MESSAGE PARITY WHICH
- * IS TRANSMITTED FOLLOWING THE END OF MESSAGE
- * CONTROL CHARACTER.
- *
- DATAOUT SUBR
- *
- * * * OUTPUT START OF MESSAGE CHARACTER
- LDM IHDR+RSOM
- CALL PUTCHR
- *
- * * * INITIALIZE POINTERS
- LDN 0
- STD ULU
- STD WU
- STD CKO
- *
- * * * GET NUMBER OF PPU WORDS IN DATA FIELD
- LDM RWDS+IHDR
- ADN 1 INCLUDE MESSAGE NUMBER
- STD NW
- *
- * * * GET NEXT CHARACTER
- DO1 BSS 0
- RJM UNPACK
- ZJN DO6 JUMP IF ALL DONE
- *
- * * * OUTPUT NEXT CHARACTER
- CALL PUTCHR
- *
- * * * UPDATE MESSAGE PARITY
- LDD OC
- LMD CKO
- STD CKO
- UJN DO1 GET NEXT CHARACTER
- *
- * * * ALL DATA OUTPUT, OUTPUT END OF MESSAGE CHARACTER
- DO6 BSS 0
- LDM IHDR+REOM GET CHARACTER FROM -LINKCTL-
- RJM PUTCHR SEND IT.
- *
- * * * OUTPUT MESSAGE PARITY CODE.
- LDD CKO
- RJM PUTCHR
- UJN DATAOUTX
- * /--- BLOCK MESSOUT 00 000 78/05/11 22.13
- TITLE SEND MESSAGE
- *
- * * MESSOUT
- *
- * SEND MESSAGE TO REMOTE SITE AND WAIT FOR
- * ACKNOWLEDGE(ACK OR NAK). IF A -NAK- IS
- * RECEIVED OR AN ERROR RESEND THE MESSAGE.
- *
- MESSOUT SUBR
- LDN 0
- STD RESEND CLEAR RESEND COUNT
- *
- * * * SEND MESSAGE
- MO1 BSS 0
- CALL DATAOUT
- *
- * * * SET SYNC CODE COUNTER TO ZERO
- LDN 0
- STD SC
- *
- * * * WAIT FOR ACK OR NAK.
- MO2 BSS 0
- CALL WCR,MCRD
- ZJP LOSTC JUMP IF CONTACT LOST
- *
- * * * PROCESS INPUT
- CALL GETCHR
- ZJN MO5 RESEND MESSAGE BAD CHR.
- PJN MO4 JUMP IF CONTROL CHAR.
- *
- * * * INCREMENT SYNC CODE COUNTER
- AOD SC
- ADC -SYEND2
- MJP MO2 WAIT FOR NEXT CHAR.
- *
- * * * TOO MANY SYNC CODES
- AOM SCCNT BUMP ERROR COUNTS
- UJP MO5
- *
- * * * CONTROL CHARACTER FOUND IS IT A ACK.
- MO4 BSS 0
- LDD CHAR
- SBN CACK
- ZJN MESSOUTX
- AOM BCCNT BUMP ERROR COUNT
- *
- * * * ALLOW 5 RESENDS, THEN GIVE UP
- MO5 BSS 0
- AOD RESEND BUMP COUNTER
- SBN RSCNT TOO MANY RESENDS ALREADY
- MJP MO1 NO, RESEND THE MESSAGE
- CALL HERROR,HRSD ISSUE ERROR
- * /--- BLOCK MESSIN 00 000 84/11/15 11.35
- TITLE RECEIVE A MESSAGE
- *
- * * MESSIN
- *
- * INPUT MESSAGE FROM REMOTE SITE, THEN SEND
- * AN ACK OR NAK DEPENDING ON CONDITION OF MESSAGE
- * RECEIVED.
- *
- * OUTPUT PARAMETERS
- * (A) = ZERO IF MESSAGE NUMBER OKAY
- * NONZERO OTHERWISE.
- *
- MESSIN SUBR
- *
- * * * WAIT FOR FIRST INPUT CHARACTER.
- MI1 BSS 0
- CALL WCR,MCRD
- ZJP LOSTC JUMP IF CONTACT LOST
- CALL GETCHR
- MJN MI3 JUMP IF SYNC CHARACTER
- ZJN MI3 JUMP IF NOT CONTROL CHAR.
- *
- * * * SAVE START OF MESSAGE CHARACTER.
- LDD CHAR GET CHARACTER
- STM OHDR+RSOM
- *
- * * * INPUT REST OF MESSAGE
- CALL DATAIN
- *
- * * * WAS MESSAGE IN GOOD SHAPE
- LDD NAKFLAG
- ZJN MI2 JUMP IF YES
- *
- * * * OTHERWISE HAVE MESSAGE RESENT.
- CALL PUTCHR,CNAK
- UJP MI1
- *
- * * * INDICATE TO REMOTE SITE THAT MESSAGE IS OKAY
- MI2 BSS 0
- CALL PUTCHR,CACK SEND POSITIVE ACKNOWLEDGE
- UJN MESSINX
- *
- * * * JUST RECEIVED SYNC CHAR.-ARE WE IN STARTUP
- MI3 BSS 0
- LDD FUNC
- SBN FASU
- NJP MI1 JUMP IF NOT
- *
- * * * IF STARTUP ONLY WAIT CERTAIN NUMBER OF CHAR. TIMES
- AOD SC INCREMENT COUNTER
- ADC -SYEND MAX. NUMBER ALLOWED.
- MJP MI1 JUMP IF TIME NOT UP
- *
- * * * OTHERWISE SEND MESSAGE BACK TO LINKCTL
- CALL SERROR,SRDR
- * /--- BLOCK SELDC 00 000 78/01/22 20.30
- TITLE SELECT 6681 DATA CONVERTER
- *
- * * SELDC
- *
- * THIS ROUTINE TAKES THE FOLLOWING STEPS IN SETTING
- * UP THE 6681 AND 3266 FOR USE.
- * 1.DEACTIVATE THE CHANNEL
- * 2.SELECT CONVERTER
- * 3.CHECK 3266 PORTS
- * 4.SELECT RESYNC AND SEND FUNCTION TO 311.
- *
- * OUTPUT PARAMETERS
- * IF (A) IS NEGATIVE, ERROR OCCURED.
- * POSITVE, EVERYTHING IS OKAY.
- *
- SELDC SUBR
- RJM CCR
- NJN SELDC1 IF EQUIP/CHANNEL RESERVED
- CALL SERROR,SENA
- SELDC1 BSS 0
- *
- * * * DEACTIVATE THE CHANNEL IF NECESSARY
- IJM SELDC2,C=CH JUMP IF CHANNEL INACTIVE
- DCN C=CH,40B DE-ACTIVATE THE CHANNEL
- RJM TIMOUT
- NJN SELDC2 JUMP IF CHANNEL DEACTIVATED.
- *
- * * * ERROR--CHANNEL DID NOT DROP
- CALL LREL RELEASE EQUIPMENT RESERVATIONS
- CALL HERROR,HDCN
- *
- * * * SELECT CONVERTER
- SELDC2 BSS 0
- FNC DCSC,C=CH FUNCTION SELECT CONVERTER
- RJM TIMOUT WAIT FOR CHANNEL TO DEACTIVATE.
- NJN SELDC4 JUMP IF CHANNEL DEACTIVATED
- *
- * * * ERROR--SELECT CONVERTER FUNCTION NOT ACCEPTED
- CALL LREL RELEASE EQUIPMENT RESERVATIONS
- CALL HERROR,HFSC
- *
- * * * SET UP 311 SO IT IS READY TO SEND AND RECEIVE.
- SELDC4 BSS 0
- PORT ODD CONNECT TO ODD CHANNEL
- RJM ST6681 CHECK FOR FUNCTION REJECT
- MJN SELDC5 IF ERROR
- *
- * * * CONNECT TO EVEN CHANNEL
- PORT EVEN CONNECT OT EVEN CHANNEL.
- RJM ST6681 CHECK FOR 6681 REJECT
- SELDC5 LJM SELDCX IGNORE ERRORS
- EJECT
- *
- * * TIMOUT
- *
- * ROUTINE TO MAKE SURE CHANNEL DEACTIVATES
- * WITHIN PROPER TIME LIMIT.
- *
- TIMOUT SUBR
- LDC TOUT TIME OUT COUNTER
- TMO1 BSS 0
- IJM TIMOUTX,C=CH IF ALL QUIET
- SBN 1
- NJN TMO1 JUMP IF COUNTER NOT EXPIRED
- UJN TIMOUTX
- * /--- BLOCK 6681 00 000 78/01/22 20.30
- SPACE 6
- *
- * * ST6681
- *
- * CHECK 6681 STATUS FOR FUNCTION REJECT.
- *
- * OUTPUT PARAMETERS
- * IF (A) IS NEGATIVE FUNCTION WAS REJECTED.
- * POSITIVE EVERTHING IS OKAY.
- *
- ST6681 SUBR
- FNC DCCS,C=CH STATUS FUNCTION
- ACN C=CH,40B ACTIVATE THE CHANNEL
- IAN C=CH,40B INPUT STATUS
- DCN C=CH,40B
- STD PS SAVE STATUS
- LPN 7 MASK REJECT BITS
- ZJN ST6681X
- *
- * * * ERROR--6681 REJECT CONNECT FUNCTION
- *
- CALL LREL RELEASE EQUIPMENT RESERVATIONS
- CALL HERROR,HREJ
- * /--- BLOCK SEST 00 000 77/08/17 15.01
- TITLE SYNCHRONIZATION ESTABLISH
- *
- * * * SEST
- *
- * ESTABLISH SYNCHRONIZATION WITH REMOTE SITE.
- * ON ENTRY (A) = NUMBER OF TIMES TO TRY
- *
- SEST SUBR
- *
- * * * SET LOOP COUNTER
- STD TT
- *
- * * * CLEAR SYNC CODE INDICATOR
- LDN 0
- STM SFLAG
- *
- * * * SELECT RESYNCH. FUNCTION
- SE0 BSS 0
- CALL OCHR2,BRSY+BSND
- *
- * * * SET NUMBER SYNCH CODES TO SEND
- LDN 4
- STD SC
- *
- * * * WAIT FOR CHARACTER REQUEST STATUS
- SE1 BSS 0
- RJM PAUSE
- CALL WCR,MCRQ WAIT FOR CHAR. REQUEST
- ZJN SE3 JUMP IF NEVER FOUND CHAR. REQ.
- *
- * * * OUTPUT SYNC CODE
- CALL OCHR,CSYN OUTPUT SYNC CODE.
- *
- * * * CHECK FOR SYNCHRONIZATION ESTABLISHED
- CALL WCPE
- STM SFLAG SET SYNC. ACHIEVED FLAG
- NJN SESTX IF ESTABLISHED
- *
- * * * HAVE ALL SYNCH CODES BEEN OUTPUT
- SOD SC
- NJP SE1 JUMP IF NOT
- *
- * * * DECREMENT COUNTER AND QUIT IF ZERO
- SOD TT
- NJN SE0
- *
- * * * ERROR - SYNCHRONIZATION NEVER ESTABLISHED
- CALL HERROR,HECP
- *
- * * * ERROR--INITIAL CHARACTER REQUEST DID NOT APPEAR
- SE3 BSS 0
- LDD CHAR SAVE STATUS FOR RESPONSE
- STD PS
- CALL HERROR,HCRQ
- * /--- BLOCK CMCAL 00 000 77/08/29 15.27
- TITLE DIVIDE BY 5
- *
- * * CMCAL
- *
- * DIVIDE NUMBER IN -A- BY FIVE AND PUT RESULT IN
- * -DL-. THE METHOD USED IS TO MULTIPLY THE
- * NUMBER BY 205, THEN DIVIDE BY 1024. THIS WORKS
- * FOR NUMBERS UPTO 1200.
- *
- CMCAL SUBR
- *
- * * * MULTIPLY BY 205. (N=NUMBER, *=MULTIPLY)
- *
- STD T1 SAVE N
- SHN 1 N*2
- ADD T1 (N*2)+N = (N*3)
- STD T2 SAVE (N*3)
- SHN 4 (N*3)*16
- ADD T2 (N*3)*16 + (N*3) = (N*51)
- SHN 2 (N*51)*4 = (N*204)
- ADD T1 (N*204)+N = (N*205)
- *
- * * * DIVIDE BY 1024
- *
- SHN -10 (N*205)/1024
- STD DL THE RESULT
- UJN CMCALX
- TITLE INCREMENT 5 BYTE COUNTER
- *
- * * AFIVE
- *
- * INCREMENT BY ONE A 5 BYTE COUNTER DESIGNATED
- * BY THE ADDRESS IN A. ALSO MOVE THE COUNTER
- * TO LKBUF SO THAT IT CAN BE WRITTEN TO ECS.
- *
- * INPUT PARAMETERS';
- * (A) = ADDRESS OF BYTE ZERO OF COUNTER
- *
- *
- AFIVE SUBR
- STD TT SAVE ADDRESS
- LDN 4
- STD T1 INITIALIZE THE LOOP COUNTER
- *
- * * * INCREMENT COUNTER STARTING WITH BYTE 4
- AF1 BSS 0
- AOM 4,TT INCREMENT THIS BYTE BY ONE
- STM LKBUF,T1 SAVE NEW VALUE FOR ECS TRANSFER
- SHN -12 CHECK FOR OVERFLOW
- ZJP AF2 JUMP IF NO OVERFLOW
- SOD TT SET TO NEXT BYTE
- SOD T1 DECREMENT BYTE COUNTER
- UJN AF1
- *
- * * * MOVE REST OF COUNTER TO LKBUF
- AF2 BSS 0
- SOD TT
- SOD T1
- MJN AFIVEX IF ALL DONE
- LDM 4,TT
- STM LKBUF,T1
- UJN AF2
- * /--- BLOCK PARGEN 00 000 77/02/15 14.05
- TITLE PARITY GENERATION
- *
- * * PARGEN
- *
- * 'THIS ROUTINE GENERATES A TABLE CONTAINING
- * ALL POSSIBLE 7 BIT COMBINATIONS THAT CAN
- * BE SENT AS DATA OR CONTROL CHARACTERS OVER
- * THE LINK PLUS THE APPROPRIATE PARITY BIT(ODD).
- * 'THUS WHEN SENDING A CHARACTER, THE CHARACTER
- * CAN BE USED AS AN INDEX INTO THIS TABLE TO GET
- * THE CHARACTER PLUS PARITY TO TRANSMIT.
- *
- PARGEN SUBR
- LDC 127 128 POSSIBLE 7 BIT CHARATERS.
- STD T1
- *
- * * * MAIN LOOP DONE ONCE FOR EACH 7 BIT CHARATER.
- *
- PG1 BSS 0
- LDN 0 INITIALIZE BIT COUNTER
- STD T2
- LDD T1 SAVE WORKING COPY OF CURRENT
- STD T3 CHARACTER.
- LDN 6 SEVEN BITS/CHARACTER
- STD T4
- *
- * * * INTER LOOP - COUNTS NUMBER OF BITS IN CHARACTER
- *
- PG2 BSS 0
- LDD T3 GET SHIFTED 7 BIT CHARACTER
- SHN 1 POSITION NEXT BIT
- STD T3 SAVE FOR NEXT LOOP
- SHN 10 MOVE BIT TO TOP
- PJN PG3 JUMP IF BIT NOT SET
- AOD T2 BIT SET INCREMENT BIT COUNTER
- PG3 BSS 0
- SOD T4 DECREMENT NUMBER OF BITS TESTED
- PJN PG2 JUMP IF MORE BITS
- *
- * * * GENERATE CHARACTER WITH PARITY BIT
- *
- LDD T2 LOAD BIT COUNT
- LPN 1 ISOLATE PARITY BIT
- LMN 1 TOGGLE BIT
- SHN 7 POSITION PARITY BIT
- ADD T1 ADD IN 7 BIT CHARACTER
- STM PARTBLE,T1 STORE IN TABLE
- *
- * * * END OF MAIN LOOP - JUMP IF MORE TO DO.
- *
- SOD T1 DECREMENT CHARACTER COUNTER.
- PJP PG1 JUMP IF NOT DONE
- UJN PARGENX
- * /--- BLOCK PAUSE 00 000 84/11/15 11.35
- TITLE PAUSE--CHECK FOR STORAGE MOVE OR ERROR CONDITIONS
- * PAUSE
- *
- * THIS ROUTINE CHECKS TO SEE IF THE STORAGE
- * MOVE OR ERROR FLAGS AT THE CONTROL POINT ARE
- * SET. IF NECESSARY, IT PAUSES AND THEN RESETS
- * THE REFERENCE ADDRESSES. IF THE CONTROL POINT
- * ERROR FLAG IS SET OR THERE IS NO CPU ACTIVITY
- * AT THE CONTROL POINT, THE PPU IS DROPPED.
- *
- PAUSE SUBR
- *
- * * * RESET PAUSE COUNTER
- LDC TOUT2
- STD TI
- *
- * * * READ CONTROL POINT STATUS
- LDD CP
- ADN STSW
- CRD CM
- LDD CM+C.CPEF ERROR FLAG
- NJP DPP2 EXIT IF CONTROL POINT ERROR.
- LDD CM+C.CPSTAT
- SHN -11B
- ZJP DPP2 IF NO CPU ACTIVITY
- *
- * * * CHECK FOR PAUSE CONDITION
- LDN CMCL
- CRD CM
- LDD CM
- SBD CP
- NJN PAUSEX IF NO PAUSE REQUIRED
- PAUSE ST
- *
- * * * READ CONTROL POINT STATUS WORD
- LDD CP
- ADN STSW
- CRD CM
- LDD CM+C.CPEF
- NJP DPP2 EXIT IF CONTROL POINT ERROR
- *
- * * * NEW PPU STATUS WORD ADDRESS
- LDM PU
- SHN 6
- ADD RA
- SHN 6
- ADM PL
- PLANT CM,PPST
- *
- * * * NEW COMMUNICATION BUFFER ADDRESS.
- LOADCM PPST
- ADN 2
- PLANT CM,COMBF
- *
- * * * ECS TRANSFER BUFFER ADDRESS
- LOADCM PPST
- ADN 22
- PLANT CM,TRNBF
- LJM PAUSEX
- SPACE 2
- *
- * * FRMCHK
- *
- * CHECK FOR FRAMAT RE-INITIALIZING. 'THIS HAPPENS
- * WHEN FRAMAT IS DROPPED AND RELOADED FOLLOWING
- * AN ECS ERROR.
- *
- FRMCHK SUBR
- *
- * * * RESET TIME OUT COUNTER
- LDN 50
- STD FRCHK
- *
- * * * READ FRAMAT STATUS WORD
- FRMCHK1 BSS 0
- LDN 0
- STD ECSOFF
- LDN 1
- STD ECS
- CALL READECS,FORINIP
- *
- * * * CHECK TO SEE IF FRAMAT RE-INITIALIZING
- LDM LKBUF
- SHN 6
- PJN FRMCHKX
- *
- * * * WAIT UNTIL FRAMAT DONE INITIALIZING
- CALL PAUSE
- DELAY 5000
- UJP FRMCHK1
- * /--- BLOCK ERROR 00 000 84/11/15 11.35
- TITLE SOFTWARE AND HARDWARE ERROR ROUTINES
- *
- * * SERROR
- *
- * THIS ROUTINE PROCESSES SOFTWARE ERRORS AS FOLLOWS';
- * 1. PUT ERROR CODE INTO RESPONSE BUFFER.
- * 2. WRITE RESPONSE TO CM
- *
- * * INPUT PARAMETERS
- * -A- MUST CONTAIN THE APPROPRIATE ERROR CODE.
- *
- SERROR SUBR
- STM OBF+RERR
- RJM WRITE
- UJP MAIN GO BACK TO MAIN LOOP
- SPACE 4
- *
- * * HERROR
- *
- * THIS ROUTINE PROCESSES HARDWARE ERRORS AS FOLLOWS';
- * 1.PUT ERROR CODE INTO RESPONSE BUFFER.
- * 2.PUT HARDWARE STATUS INTO RESPONSE BUFFER.
- * 3.WRITE RESPONSE BACK TO CM.
- *
- * *INPUT PARAMETERS
- * -A- MUST CONTAIN ERROR CODE.
- * -PS- MUST CONTAIN APPROPRIATE STATUS
- *
- HERROR SUBR
- STM OBF+RERR PUT ERROR CODE IN RESPONSE
- LDD PS GET HARDWARE STATUS
- STM OBF+RSTA PUT STATUS INTO RESPONSE
- RJM WRITE WRITE RESPONSE TO CM.
- LDD MODE CHECK FOR TERMINAL MODE
- ZJP MAIN JUMP IF DATA MODE
- LDC LABK KEY TO BE PRESSED
- STM RQKEY
- CALL PREQ,PKEY SEND A KEY TO WAKE UP LINKCTL
- LJM MAIN
- SPACE 2
- *
- * *LOSTC
- * LOST CONTACT WITH REMOTE SITE EXIT
- *
- LOSTC BSS 0
- CALL HERROR,HLCR
- * /--- BLOCK DPP 00 000 78/05/11 22.05
- TITLE EXIT ROUTINES
- DPP BSS 0
- CALL TMEND
- CALL PREQ,PKILL SEND KILL REQUEST TO PLATO.
- DPP2 BSS 0
- LDN 1 MARK DROPPING PPU
- STM DPPF
- CALL STDPP IF EQUIPMENT UP SEND STOP CODE.
- CALL LREL RELEASE COMMUNICATION LINK
- MONITOR DPPM
- LJM PPR EXIT TO IDLE LOOP.
- SPACE 2
- *
- * *DROPCHK
- *
- * CHECK FOR PLATO LESSON DROP SIGNAL
- *
- DROPCHK SUBR
- LOADCM PPST PPU STATUS WORD.
- CRD CM
- LDD CM+4
- ZJP DPP JUMP IF BIT CLEARED
- UJN DROPCHKX
- TITLE SEND END LINK
- *
- * * STDPP
- *
- * 'THIS ROUTINE SELECTS -STOP SEND- ON 3266.
- *
- STDPP SUBR
- *
- * * * EXIT IF EQUIPMENT OR CHANNEL IS NOT RESERVED.
- *
- RJM CCR
- ZJN STDPPX
- *
- * * * SEND 100 BAD CHARACTERS TO OTHER SYSTEM
- LDC 100
- STD RESEND SET CHARACTER COUNT
- *
- * * * WAIT FOR CHARACTER REQUEST
- STD1 BSS 0
- LDC 7777B
- STD D0 NO. OF TIMES TO LOOK FOR STATUS
- *
- * * * CHECK FOR CHARACTER REQUEST STATUS
- STD2 BSS 0
- CALL ICHR INPUT STATUS
- LPC MCRQ CHAR. REQUEST MASK
- NJP STD3 JUMP IF STATUS APPEARED
- *
- * * * DECREMENT STATUS CHECK COUNTER
- SOD D0
- ZJP STD4 JUMP IF NO CHAR. REQUEST
- UJP STD2 LOOP AND CHECK AGAIN
- *
- * * * SEND CHARACTER
- STD3 BSS 0
- LDN 3
- CALL OCHR OUTPUT CHAR.
- *
- * * * HAVE 100 CHAR. BEEN OUTPUT
- SOD RESEND DECREMENT COUNTER
- PJP STD1 LOOP IF NOT
- *
- * * * SET UP CONTROLLER FOR NEXT TRY
- STD4 BSS 0
- CALL OCHR2,BSTP+BRSY
- LJM STDPPX
- * /--- BLOCK T DPP 00 000 77/09/06 00.40
- TITLE TERMINAL MODE TERMINATION
- *
- * * TMEND
- *
- * THIS ROUTINE DOES THE EXTRA PROCESSING NEEDED
- * WHEN LEAVING TERMINAL MODE PROCESSING ROUTINES.
- *
- TMEND SUBR
- LDD MODE
- ZJN TMENDX IF NOT IN TERMINAL MODE
- *
- * * * PRESS KEY ON CALLING STATION
- *
- LDC LABK PRESS A LAB KEY
- STM RQKEY
- CALL PREQ,PKEY
- *
- * * * CLEAR FRAMER STATUS WORD
- CALL LCLEAR,5 CLEAR 5 BYTES OF LKBUF
- LDN 1
- STD ECS WRITE ONE WORD OF ECS
- LDM FRAMID OFFSET TO CORRECT WORD
- STD ECSOFF
- CALL WRITECS,PIOSTS
- UJN TMENDX
- *
- * * LCLEAR
- *
- * CLEAR INDICATED NUMBER OF BYTS IN -LKBUF-
- *
- * INPUT PARAMETER
- * (A) = NUMBER OF BYTES TO CLEAR
- *
- LCLEAR SUBR
- SBN 1
- STD T1
- LCL BSS 0
- LDN 0
- STM LKBUF,T1
- SOD T1
- PJN LCL JUMP IF MORE TO CLEAR
- UJN LCLEARX
- * /--- BLOCK PREQ 00 000 78/05/11 21.52
- TITLE SEND PLATO REQUEST
- *
- * * PREQ
- *
- * SEND REQUEST TO PLATO
- * (A) CONTAINS REQUEST CODE ON ENTRY.
- * (RQKEY) CONTAINS KEY VALUE FOR REQUEST.
- *
- PREQ SUBR
- STD TT SAVE REQUEST CODE
- *
- * * * CHECK FOR PENDING REQUEST
- PREQ1 BSS 0
- LOADCM PPST ADDRESS OF CM BUFFER
- ADN 1 BUMP TO REQUEST SLOT
- CRD T1 MAKE SURE NO REQUEST PENDING
- LDD T1
- NJN PREQ2 JUMP IF PENDING REQUEST
- *
- * * * SET UP NEW REQUEST
- LDD TT GET REQUEST CODE
- STD CM+4 PUT REQUEST CODE INTO BUFFER
- LDM RQKEY GET KEY TO PUT INTO REQUEST
- STD CM+3
- LDD STATION PUT STATION NUMBER IN REQUEST
- STD CM+2
- LDN 0
- STD CM+1
- LDC 4000B SET REQUEST BIT
- STD CM
- *
- * * * GIVE NEW REQUEST TO PLATO
- LOADCM PPST NOTHING PENDING WRITE NEW REQ.
- ADN 1
- CWD CM
- UJN PREQX
- *
- * * * WAIT FOR PENDING REQUEST TO BE PROCESSED
- PREQ2 BSS 0
- DELAY 4000
- CALL PAUSE
- UJP PREQ1
- *
- * /--- BLOCK LOOPCHK 00 000 84/11/15 11.35
- TITLE PROCESS 3266 INPUT
- *
- * * LOOPCHK
- *
- * PROCESS 3266 INPUT WHILE WAITING ON LINKCTL
- * TO SEND NEXT COMMAND.
- *
- LOOPCHK SUBR
- *
- * * * EXIT IF EQUIPMENT/CHANNEL NOT RESERVED
- RJM CCR
- ZJN LOOPCHKX
- *
- * * * SET SPECIAL WAIT-ON-LINKCTL FLAG
- LDN 1
- STM WAITF
- *
- * * * WAIT FOR INPUT CHARACTER
- CALL WCR,MCRD
- ZJP WAITL JUMP IF NO CHARACTER APPEARED
- *
- * * * PROCESS NEW CHARACTER
- CALL GETCHR
- *
- * * * CLEAR SPECIAL FLAG
- LDN 0
- STM WAITF
- UJN LOOPCHKX
- TITLE WAIT ON LINKCTL
- *
- * * WAITL
- *
- * THIS ROUTINE IS CALLED IF THE LINK IS DROPPED
- * WHILE CLD IS WAITING FOR A LINKCTL COMMAND.
- * WHEN THE NEXT COMMAND ARRIVES LINKCTL IS
- * INFORMED OF THE ERROR.
- *
- WAITL BSS 0
- *
- * * * CHECK FOR PAUSE CONDITION
- CALL PAUSE
- *
- * * * CHECK FOR DROP SIGNAL FROM LINKCTL
- CALL DROPCHK
- *
- * * * CHECK FOR LINKCTL COMMAND
- CALL READSW
- ZJN WAITL NO NEW COMMAND, LOOP
- *
- * * * NEW COMMAND ARRIVED, SEND ERROR TO LINKCTL
- CALL HERROR,HBCH
- * /--- BLOCK EQUATES 00 000 78/05/11 22.16
- TITLE EQUATES
- ************************************************************************
- *
- LAB1K EQU 213B LAB1 KEY CODE
- *
- LABK EQU 212B LAB KEY CODE
- *
- LKMASK EQU 177B LINKIO BUFFER LENGHT MASK
- *
- TMASK EQU 777B TERMINAL MODE MODULO MASK
- *
- CHPK EQU 2 CHARACTERS PER KEY
- *
- CHPF EQU 4 CHARACTERS PER FRAME
- *
- ALSEVEN EQU 7777B CONSTANT
- *
- TOUT EQU 777B TIME OUT LOOP COUNTER
- *
- TOUT2 EQU 100B
- *
- MCHR8 EQU 377B 8 BIT CHARACTER MASK
- *
- MCHR7 EQU 177B CHARACTER MASK FOR DATA INPUT
- *
- DCON EQU 100B BIT ADD TO INDICATE DATA
- * CHARACTER.
- RSCNT EQU 30 NUMBER OF TIMES TO RESEND
- * A MESSAGE BEFORE GIVING UP.
- PEND EQU 30 NUMBER OF CONSECUTIVE BAD
- * CHAR. BEFORE GIVING UP.
- SYEND EQU 2000 NUMBER OF SYNC. CHAR TO WAIT
- * WHEN CHECKING FOR REMOTE REQ.
- SYEND1 EQU 10 NUMBER CONSECUTIVE SYNC CHAR
- * ALLOWED DURING A MESSAGE.
- SYEND2 EQU 500 NUMBER OF SYNC. CHAR. TO WAIT
- * WHEN LOOKING FOR ACK/NAK.
- MAXCM EQU 60 MAXIMUM SIZE OF LINKCTL REQUEST
- *
- XFORINIP EQU 2 ECS ADDRESS OF FORMATTER-
- * FRAMER STATUS WORD
- ************************************************************************
- * /--- BLOCK DEFINES 00 000 78/05/11 21.58
- TITLE STORAGE DEFINITIONS
- ************************************************************************
- *
- *
- CLEQ DATA 7777B EST ORDINAL OF -CL- AFTER
- * EQUIPMENT RESERVED OTHERWISE
- * SET TO ALL SEVENS.
- CLCH DATA 7777B SET TO ALL SEVENS UNTIL
- * COMMUNICATION CHANNEL IS
- * RESERVED, THEN SET TO CHANNEL.
- SFLAG BSSZ 1 0 IF SYNC. NOT ACHIEVED,
- * NONZERO OTHERWISE
- WAITF BSSZ 1 1 = PROCESSING INPUT WHILE
- * WAITING FOR LINKCTL COMMAND.
- * 0 ALL OTHER TIMES.
- RQKEY BSSZ 1 KEY IN PRESS REQUEST TO PLATO
- *
- PECNT BSSZ 1 NUMBER OF CHARACTER PARITY
- * ERRORS.
- BDCNT BSSZ 1 NUMBER OF BAD CHARACTERS.
- *
- LPCNT BSSZ 1 NUMBER OF BAD LONGITUDINAL
- * PARITY CHARACTERS.
- SCCNT BSSZ 1 NO. OF MESSAGES RESENT BECAUSE
- * NO RESPONSE WAS RECEIVED.
- BCCNT BSSZ 1 NO. OF MESSAGES RESENT BECAUSE
- * RESPONSE WAS NOT AN -ACK-.
- LKBUF BSSZ 40 ECS READ/WRITE BUFFER
- *
- IFRAMEX BSSZ 1 TEMPORARY SAVE AREA FOR FRAME
- * INDEX.
- IFRAME BSSZ 5 CLD FRAME POINTER MATCHES
- * ECS RESIDENT LFRPNT.
- PFRAME BSSZ 5 CLD LINKIO POINTER MATCHES
- * ECS RESIDENT LKIN
- FRBUFF BSSZ 2 TERMINAL MODE FRAME BUFFER.
- *
- KYBUFF DATA 7777B TERMINAL MODE KEY BUFFER.
- *
- LFRLTH BSSZ 1 NO. OF TERMINAL WORDS IN
- * EACH FRAME.
- FRAMID BSSZ 1 LINK FRAME ID
- *
- DPPF BSSZ 1 NON-ZERO IF DROP PPU IN PROCESS
- *
- CLKU BSSZ 2 RUNNING CLOCK
- CLKL EQU CLKU+1
- *
- PU BSSZ 2 CM ADDRESS OF PARAMETER AREA
- PL EQU PU+1
- *
- * /--- BLOCK DEFINES 00 000 78/01/04 21.30
- ECU BSSZ 2 ECS RA
- ECL EQU ECU+1
- *
- ECSAD BSS 0 ECS ADDRESS TABLE
- PKEYECS BSSZ 2 KEY BUFFER
- *
- PECSIN BSSZ 2 KEYS-IN BIT TABLE
- *
- LINKIO BSSZ 2 TERMINAL WORD BUFFER FOR
- * PASSING INFO TO THE FRAMER.
- LKIN BSSZ 2 POINTER TO NEXT LOCATION IN
- * TERMINAL WORD BUFFER.
- LFRBUF BSSZ 2 FRAME BUFFERS
- *
- LFRPNT BSSZ 2 POINTER TO NEXT LOCATION IN
- * FRAME BUFFERS.
- LFRLTHS BSSZ 2 NO. OF TERMINAL WORDS IN EACH
- * FRAME.
- PIOSTS BSSZ 2 FRAMER STATUS WORD - INDICATES
- * CLD IS READING FRAMES
- ECSLTH EQU *-ECSAD LENGTH OF ECS ADDRESS TABLE
- *
- FORINIP BSSZ 2 FORMATTER-FRAMER STATUS WORD
- * ECS ADDRESS
- * /--- BLOCK IBF 00 000 77/10/03 14.21
- TITLE COMMUNICATION BUFFERS
- ************************************************************************
- *
- * THIS BUFFER IS USED TO HOLD REQUESTS AND DATA
- * FROM LINKCTL. 'THE SWITCH WORD IS CONTIGUOUS
- * WITH THE REST OF THE BUFFER IN THE CM BUFFER
- * BUT IS READ SEPARATLY BY THE LINK DRIVER.
- *
- * BYTE DESCRIPTIONS';
- * SWITCH WORD
- * / 0 / 0 / 0 / 0 / NUMBER OF WORDS IN REQUEST(CM) /
- * PARAMETER SECTION (IBF)
- * / 0 / 0 / 0 / 0 / LINK FUNCTION CODE (RFUNC) /
- * / RSTA1 / RSTA / UNUSED / UNUSED / RERR /
- * MESSAGE INFO (IHDR)
- * / REOM / RWDS / STNO / RSOM / RMNO (ISTART) /
- * START OF ACTUAL DATA (XBUFF)
- * / 200 BYTES OF DATA /
- *
- PLTH EQU 2 CM WORDS IN PARAMETER SECTION
- *
- DLTH EQU 300 PPU WORDS IN DATA BUFFERS
- *
- PPOS EQU 1 OFFSET TO PARAMETER SECTION
- * (CM WORDS)
- DPOS EQU 3 OFFSET TO MESSAGE INFO SECTION
- * (CM WORDS)
- IBF BSS PLTH*5 PARAMETER SECTION
- *
- IHDR BSS 5 MESSAGE INFO
- *
- ISTART EQU IHDR+4 FIRST BYTE TRANSMITTED
- * (MESSAGE NUMBER)
- XBUFF BSS DLTH START OF ACTUAL DATA
- *
- * /--- BLOCK IBF 00 000 77/09/07 23.18
- *
- * * * FOLLOWING ARE LOCATIONS OF VARIOUS PARAMETERS
- * SUPPLIED FOR CERTIAN LINK DRIVER FUNCTIONS.
- *
- XPORTCH EQU XBUFF+4 WORD WHERE 311 CHANNEL IS
- * RECEIVED FROM LINKCTL.
- XECU EQU XBUFF+8 PLATO*S ECS RA UPPER 9 BITS
- *
- XECL EQU XBUFF+9 PLATO*S ECS RA LOWER 12 BITS
- *
- XTMSTAT EQU XBUFF+9 TERMINAL MODE STATION NO.
- *
- XPKEYEC EQU XBUFF+13 ECS ADDRESS OF KEY BUFFER
- *
- XPECSIN EQU XBUFF+18 ECS ADDR. OF KEYS-IN BIT TABLE
- *
- XLINKIO EQU XBUFF+23 ECS ADDR. OF TERMINAL WORD BUF.
- *
- XLKIN EQU XBUFF+28 ECS ADDRESS OF POINTER TO NEXT
- * POSITION IN TERMINAL WORD BUF.
- XLFRBUF EQU XBUFF+33 ECS ADDRESS OF FRAME BUFFERS
- *
- XLFRPNT EQU XBUFF+38 ECS ADDRESS OF FRAME BUFFER
- * POINTER.
- XFRLTHS EQU XBUFF+43 ECS ADDRESS OF FRAME LENGTH
- * TABLE
- XPIOSTS EQU XBUFF+48 FRAMER STATUS WORD
- *
- XLFRLTH EQU XBUFF+54 NO. OF TERMINAL WORDS PER
- * FRAME.
- XFRAMID EQU XBUFF+59 LINK FRAME ID
- *
- XPATTRN EQU XBUFF+9 TEST PATTERN FOR LOOP BACK
- *
- XLOOPS EQU XBUFF+14 0=RECEIVE 100 LOOPBACK CHARS
- * 1=RECEIVE INFINITE NO. OF CHARS
- *
- * * * BYTE POSITIONS OF FIELDS IN PARAMETER SECTION
- *
- RFUNC EQU 4 FUNCTION CODE
- *
- RERR EQU 9 ERROR CODE
- *
- RSTA1 EQU 5 SECONDARY STATUS
- *
- RSTA EQU 6 EQUIPMENT STATUS
- *
- *
- * * * BYTE POSITION OF FIELDS IN MESSAGE INFO SECTION
- *
- RSOM EQU 3 START OF MESSAGE CHARACTER
- *
- REOM EQU 0 END OF MESSAGE CHAR.
- *
- STNO EQU 2 LINKCTL STATION NO.
- *
- RMNO EQU 4 MESSAGE NUMBER
- *
- RWDS EQU 1 PPU WORD COUNT
- *
- ************************************************************************
- * /--- BLOCK OBF 00 000 77/09/07 01.20
- TITLE COMMUNICATION BUFFERS
- ************************************************************************
- *
- * THIS BUFFER IS USED FOR SENDING DATA AND
- * RESPONSE PARAMETERS TO LINKCTL. 'THE SWITCH
- * WORD IS APPENDED TO THE FOLLOWING BUFFER AFTER
- * IT IS WRITTEN TO CENTRAL MEMORY.
- *
- * BYTE DESCRIPTIONS';
- * SWITCH WORD (BUILT AT A SEPARATE LOCATION)
- * / 4000B / 0 / 0 / NO. OF WORDS RETURNED(CM) / 0 /
- * PARAMETER SECTION (OBF)
- * / 0 / 0 / 0 / 0 / UNUSED /
- * / RSTA1 / RSTA / UNUSED / UNUSED / RERR /
- * MESSAGE INFO SECTION (IHDR)
- * / REOM / RWDS / STNO / RSOM / RMNO (OSTART) /
- * START OF ACTUAL DATA (DBUFF)
- * / 200 BYTES OF DATA /
- *
- MAXIN EQU DLTH+4 MAXIMUM NUMBER OF BYTES+2 IN
- * A MESSAGE FROM REMOTE SITE.
- OBF BSSZ PLTH*5 OUTPUT BUFFER FOR PARAMETER
- *
- OHDR BSS 5 MESSAGE INFO
- *
- OSTART EQU OHDR+4 LOCATION TO STORE 1ST BYTE OF
- * MESSAGE (MESSAGE NUMBER).
- DBUFF BSS DLTH LOCATION OF FIRST BYTE OF DATA.
- *
- *
- * * * LOCATIONS OF VARIOUS PARAMETERS RETURNED TO
- * LINKCTL.
- *
- DSTATS EQU DBUFF+4 LINK DRIVER STATISTICS
- *
- ************************************************************************
- * /--- BLOCK ERROR CODE 00 000 78/01/05 09.04
- TITLE ERROR CODES
- ************************************************************************
- *
- * * ERROR CODES
- * CODES 0,1, AND 2 SAVE FOR PPU CALL ERRORS WHICH
- * ARE GENERATED BY TUTOR COMMAND LOADPPU.
- *
- SIFC EQU 3 ILLEGAL FUNCTION CODE
- SENA EQU 4 EQUIPMENT NOT AVAILABLE
- SCNA EQU 5 CHANNEL NOT AVAILABLE
- SRDR EQU 6 REMOTE DID NOT RESPOND AFTER
- * SENDING DURING STARTUP.
- HDCN EQU 7 CHANNEL WOULD NOT DEACTIVATE.
- HFSC EQU 8 COULD NOT SELECT 6681.
- HECP EQU 9 COULD NOT ESTABLISH CHARACTER
- * PHASE IN 311.
- HCNO EQU 10 CARRIER NOT ON IN 311.
- HDSF EQU 11 DATA SET FAILURE.
- HCRQ EQU 12 INITIAL CHARACTER REQUEST
- * NEVER APPEARED.
- HREJ EQU 13 6681 REJECTED CONNECT FUNCTION
- HSYN EQU 14 SYNCHRONIZATION LOST.
- HLCR EQU 15 LOST CONTACT WITH REMOTE SITE
- SCML EQU 16 LINKCTL REQUEST TOO LONG
- HRSD EQU 17 MESS. CANNOT BE SENT CORRECTLY
- HMLT EQU 18 MESSAGE TOO LONG.
- HBCH EQU 19 TOO MANY CONSECUTIVE BAD CHAR.
- ************************************************************************
- * /--- BLOCK FUNC SOFT 00 000 76/10/14 13.31
- TITLE COMMAND CODES AND CONTROL CHARACTERS
- ************************************************************************
- *
- * COMMAND CODES FROM -LINKCTL-.
- *
- ************************************************************************
- *
- FASU EQU 0 CHECK FOR STARTUP
- FRES EQU 1 RESERVE DRIVER.
- FMES EQU 2 SEND AND RECEIVE A MESSAGE
- FREL EQU 3
- FSTA EQU 4 RETURN 311 STATUS
- FSTI EQU 5 RETURN STATISTICS COUNTERS
- FTST EQU 6 RUN LOOP BACK TEST
- FLTL EQU 7 LOCAL TERMINAL MODE
- FRTL EQU 10B REMOTE TERMINAL MODE
- FSIL EQU 11B UNUSED
- FNTL EQU 12B NEW LOOPBACK TEST.
- *
- ************************************************************************
- SPACE 4
- ************************************************************************
- *
- * CONTROL CHARACTERS
- *
- ************************************************************************
- *
- CEOD EQU 30B END OF DATA
- CEOB EQU 31B END OF BLOCK
- CEOF EQU 32B END OF FILE
- CNAK EQU 33B NEGATIVE ACKNOWLEDGE
- CACK EQU 34B POSITIVE ACKNOWLEDGE
- CETM EQU 35B END OF TERMINAL MODE
- CSYN EQU 62B SYNCH CODE
- CMAX EQU 77B MAXIMUM CONTROL CHARACTER
- *
- ************************************************************************
- SPACE 2
- ************************************************************************
- *
- * PLATO REQUEST CODES
- *
- ************************************************************************
- PKILL EQU 1 KILL THIS PPU ROUTINE
- PKEY EQU 2 PRESS A KEY ON LINKCTL
- ************************************************************************
- * /--- BLOCK FUNC HARD 00 000 76/04/07 23.34
- TITLE 6681 AND 311-B CODES
- ************************************************************************
- *
- * 6681 DATA CHANNEL CONVERTER CODES
- *
- ************************************************************************
- DCSC EQU 2000B SELECT CONVERTER
- DCDC EQU 2100B DESELECT CONVERTER
- DCIC EQU 1500B INPUT CODE
- DCOC EQU 1600B OUTPUT CODE
- DCMC EQU 1700B MASTER CLEAR
- DCCS EQU 1200B CONVERTER STATUS
- DCES EQU 1300B EQUIPMENT STATUS
- ************************************************************************
- SPACE 4
- ************************************************************************
- *
- * 311-B FUNCTION CODES.
- *
- ************************************************************************
- BSTP EQU 1 SELECT STOP
- BSND EQU 2 SELECT SEND
- BRSY EQU 4 RESYNC CODE.
- BSAR EQU 6 COMBINED SEND AND RESYNC CODE.
- ************************************************************************
- SPACE 4
- ************************************************************************
- *
- * 311 STATUS MASKS
- *
- ************************************************************************
- *
- MCPE EQU 1000B CHARACTER PARITY ERROR.
- MCRQ EQU 2000B CHARACTER REQUEST
- MCRD EQU 4000B CHARACTER READY
- MCST EQU 2 CARRIER ON
- MCPH EQU 1 CHARACTER PHASE
- MCSR EQU 4000B ODD CHANNEL STATUS READY
- *
- * /--- BLOCK INITIAL 00 000 78/02/06 10.58
- TITLE INITIALIZATIONS
- *
- INITIAL SUBR
- *
- * * * READ CONTROL POINT STATUS
- LDD CP
- ADN STSW READ CONTROL POINT STATUS
- CRD CM
- LDD CM+C.CPEF
- NJP DPP2 DROP PPU IF ERROR
- *
- * * * GET CALL STATUS WORD
- LDD IR+3 READ STATUS WORD
- LPN 37B
- STM PU SAVE RELATIVE ADDRESS
- SHN 12
- ADD IR+4
- STM PL SAVE BOTTOM OF RELATIVE ADDR.
- CALL ABS CONVERT TO ABSOLUTE
- ZJP INITE JUMP IF OUT OF RANGE
- *
- * * * PLANT ABSOLUTE ADDRESS OF CALL STATUS WORD
- PLANT CM,PPST
- *
- * * * READ PPU CALL STATUS WORD
- LOADCM PPST
- CRD CM
- LDN 1 INDICATE PPU UP AND RUNNING
- STD CM+4
- LOADCM PPST
- CWD CM REWRITE STATUS WORD.
- *
- * * * FORM ABSOLUTE ADDRESS OF COMMUNICATION BUFFER
- LOADCM PPST
- ADN 2
- PLANT CM,COMBF
- *
- * * * PLANT ADDRESS USED FOR ECS TRANSFERS
- LOADCM PPST
- ADN 22
- PLANT CM,TRNBF
- *
- * * * INITIALIZE WAIT FOR CHARACTER READY STATUS COUNTER
- LDC ALSEVEN
- STD NC
- *
- * * * INITIALIZE I/O CHARACTER COUNTS.
- LDN 0
- STD DL
- STM SFLAG
- STD ECSOFF
- STD BADC
- STD MODE
- LDN 50
- STD FRCHK TIME-OUT COUNTER FOR READING
- * FRAMAT STATUS
- LJM INITIALX
- *
- * * * ADDRESS OUT OF RANGE SENT AN ERROR CODE.
- INITE BSS 0
- CALL DFM,CMSG
- LJM DPP DROP PPU.
- *
- CMSG DIS ,*(CLD)CM ADDRESS OUT OF RANGE*
- *
- PARTBLE BSS 128 START OF PARITY TABLE
- *
- *CALL PLAPABS
- *CALL PLAPDNM
- *CALL PLAPEQN
- *CALL PLAPPLN
- *
- C=CH TABLE CHANNEL 3266 CHANNEL TABLE
- *
- E=CH TABLE CHANNEL 311 EVEN CHANNEL
- *
- O=CH TABLE CHANNEL 311 ODD CHANNEL
- *
- PPST TABLE CM PPU CALL STATUS TABLE
- *
- COMBF TABLE CM COMMUNICATION BUFFER TABLE
- *
- TRNBF TABLE CM ADDRESS USED FOR ECS TRANSFERS
- *
- ERRNG 7777B-* PP OVERFLOW
- END