User Tools

Site Tools


cdc:nos2.source:opl871:cmrinst

CMRINST

Table Of Contents

Source Code

CMRINST.txt
*NOSEQ 
CMRINST
INSTRUCTIONS FOR INITIAL SETUP OF THE OPERATING SYSTEM.
USE + KEY TO SEE NEXT PAGE.

NEXT. WILL CAUSE THE LOAD TO CONTINUE.
IPR. WILL CONTINUE THE LOAD TO THE *IPRDECK* DISPLAY.
GO. WILL CONTINUE THE LOAD WITHOUT FURTHER DISPLAYS.
THE RIGHT BLANK KEY ADVANCES THE DISPLAY.

BSP=X.    BUILD *SCI* PARAMETER TABLE IF X=Y, OR DO NOT
            BUILD IF X=N.  IT IS BUILT BY DEFAULT.
CLT=N.    SET CLT LENGTH = N OCTAL ENTRIES.
            N=0-7777B.  DEFAULT IS 0.
DFT=X.    SET *DFT* TO DEDICATED MODE, IF X=D, OR TO
            NON-DEDICATED MODE, IF X=N.
          (THE *VE* ENTRY WILL ALSO FORCE DEDICATED MODE).
DUALCPU=X. SET THE DUAL CPU MODE FOR DUAL STATE (960 ONLY).
            X = N, TO DEDICATE SECOND CPU TO NOS.
            X = V, TO DEDICATE SECOND CPU TO NOS/VE.
            DEFAULT IS DUALCPU=V.
EJT=N.    SET EJT LENGTH = N OCTAL ENTRIES.
            N=3-7777B.  DEFAULT IS 620B.
EMB=N.    SET ERROR MESSAGE BUFFER LENGTH = N OCTAL WORDS.
            N=200B-7777B.  DEFAULT IS 200B.
EQP=NN.   ASSEMBLE EQUIPMENT PARAMETER DECK EQPDNN.
            NN=00-77B.  DEFAULT IS SAME NUMBER AS CMRDECK.
FNT=N.    SET FNT LENGTH = N OCTAL ENTRIES.
            N=3-7777B.  DEFAULT IS 23B.
FOT=N.    SET FOT LENGTH = N OCTAL ENTRIES.
            N=3-100B.  DEFAULT IS 10B.
INB=N.    SET INSTALLATION BLOCK LENGTH = N OCTAL WORDS.
            N=0-7777B.  DEFAULT IS 0.
IPD=NN.   ASSEMBLE INSTALLATION PARAMETER DECK IPRDNN.
            NN=00-77B.  DEFAULT IS FIRST IPRDECK FOUND.
LIB=NN.   BUILD SYSTEM USING LIBDECK LIBDNN.
            NN=00-77B.  DEFAULT IS LIBD00.
LDT=N.    SET NUMBER OF WORDS TO BE RESERVED FOR THE
          LID TABLE.  N=0-1100B.  DEFAULT IS 1.
MID=MM.   SET MACHINE IDENTIFIER = MM.
            MM=TWO ALPHANUMERIC CHARACTERS.  DEFAULT IS AA.
MINCM=N.  SET THE MINIMUM AMOUNT OF NOS CENTRAL MEMORY = N
          HUNDRED OCTAL WORDS.  THE ACTUAL AMOUNT OF
          MEMORY USED AS NOS CENTRAL MEMORY WILL BE
          (PHYSICAL SIZE) - (UEM SIZE) - (NOS/VE SIZE).
            N=ONE TO FOUR DIGIT OCTAL VALUE.
            N=ONE TO FIVE DIGIT OCTAL VALUE FOR 865, 875
            AND 180 CLASS MODELS.
            DEFAULT AND MINIMUM IS 1400B (49K).
MLST=NN.  SET THE SIZE OF THE MESSAGE LINK STATUS TABLE.
            NN=0-77B WORDS.  DEFAULT=17B.  DUAL STATE ONLY.
NAME=CC-CC.  SET THE SYSTEM NAME = CC-CC.
            CC-CC IS .LE. 38 ALPHANUMERIC CHARACTERS.
NCP=N.    SET THE NUMBER OF CONTROL POINTS = N.
            N=2-34B.  DEFAULT IS 12B.
OPSECM=N. SET THE SECURITY MODE OF THE SYSTEM.
            N =0-3 (SECURITY MODE).
            DEFAULT IS 0 (UNSECURED MODE).
ORT=N.    SET ORT LENGTH = N OCTAL ENTRIES.
            N=0-7777B. DEFAULT IS 100B.
PCP=N.    SET THE NUMBER OF PSEUDO-CONTROL POINTS = N.
            N=0-34B.  DEFAULT IS 0.
QFT=N.    SET QFT LENGTH = N OCTAL ENTRIES.
            N=3-7777B.  DEFAULT IS 620B.
VE=N.     SET SIZE OF RESERVED NOS/VE MEMORY TO N THOUSAND
          OCTAL WORDS.  REQUIRED TO RUN DUAL STATE.
            N=0 WILL CAUSE DYNAMIC MEMORY ALLOCATION.
            N=* WILL CLEAR ENTRY (NO DUAL STATE POSSIBLE).
            DEFAULT = *.
VERSION=CC-CC.  SET VERSION NAME = CC-CC.
            CC-CC IS .LE. 18 ALPHANUMERIC CHARACTERS.
*WEOR
*WEOR
cdc/nos2.source/opl871/cmrinst.txt ยท Last modified: 2023/08/05 17:24 by Site Administrator